Review



laser confocal microscope raman spectrometer  (HORIBA Ltd)


Bioz Verified Symbol HORIBA Ltd is a verified supplier
Bioz Manufacturer Symbol HORIBA Ltd manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    HORIBA Ltd laser confocal microscope raman spectrometer
    Laser Confocal Microscope Raman Spectrometer, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 99/100, based on 8559 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/raman+microscope/LabRAM+HR+Evolution/pm42863147-117-10-18
    Average 99 stars, based on 8559 article reviews
    laser confocal microscope raman spectrometer - by Bioz Stars, 2026-11
    99/100 stars

    Images

    Related Articles

    other:

    Article Title: Thermal Transport in Atomic Layer Deposition-Grown Beryllium Oxide Thin Films and Implications on Device Cooling.
    Article Snippet: Measurements were performed using a Horiba LabRAM HR Evolution Raman spectrometer equipped with a 532 nm excitation laser in a 180° backscattering configuration.

    Article Title: High-temperature tribological behavior of a thin cold-sprayed Cr2AlC coating on H13 steel: Role of an oxidation-derived tribo-layer
    Article Snippet: Cold spraying provides an effective route for fabricating MAX phase coatings while minimizing phase decomposition, and oxidation associated with conventional thermal spraying.. In this study, a thin Cr2AlC coating with a thickness of 4.7 ± 0.6 μm was deposited on H13 steel via cold spraying using agglomerated spherical Cr2AlC feedstock, and its high-temperature tribological behavior was investigated under reciprocating sliding at 1000 C. Compared with uncoated H13 steel, the Cr2AlC-coated specimen exhibited a more uniform worn morphology and a lower wear loss, whereas the difference in friction coefficient was relatively limited.. Notably, the wear-track depth of the coated specimen exceeded the initial coating thickness, indicating that the Cr2AlC coating did not act solely as a thickness-dependent mechanical barrier.

    Photoluminescence:

    Article Title: Encoding Light in Electronic Noise.
    Article Snippet: Scanning electron microscopy (SEM) of the 2D MoS2 transistors used in this study was taken using a Zeiss Gemini 500 field-emission scanning electron microscopy (FESEM) system at an accelerating voltage of 5 kV. .. Raman and photoluminescence (PL) spectra measurement was acquired on a Horiba LabRAM HR Evolution confocal Raman microscope, using a 532 nm laser set to 34 mW, filtered at 1%. ..

    Confocal:

    Article Title: Encoding Light in Electronic Noise.
    Article Snippet: Scanning electron microscopy (SEM) of the 2D MoS2 transistors used in this study was taken using a Zeiss Gemini 500 field-emission scanning electron microscopy (FESEM) system at an accelerating voltage of 5 kV. .. Raman and photoluminescence (PL) spectra measurement was acquired on a Horiba LabRAM HR Evolution confocal Raman microscope, using a 532 nm laser set to 34 mW, filtered at 1%. ..

    Article Title: Thermally Tunable Fading Memory Enabled by Opto-Ionic-Electronic Coupling in AgInP2S6-Gated Two-Dimensional Field-Effect Transistors.
    Article Snippet: .. Raman spectroscopy of the AgInP2S6 crystals was performed using a Horiba LabRAM HR Evolution confocal Raman microscope with a 532 nm laser and a grating spacing of 1800 gr/mm for Raman spectroscopy and 300 gr/mm for PL spectroscopy. .. Powder X-ray diffraction patterns of synthesized crystals were obtained using a Rigaku MiniFlex 600 X-ray diffraction system equipped with a D/teX silicon 1D detector.

    Microscopy:

    Article Title: Encoding Light in Electronic Noise.
    Article Snippet: Scanning electron microscopy (SEM) of the 2D MoS2 transistors used in this study was taken using a Zeiss Gemini 500 field-emission scanning electron microscopy (FESEM) system at an accelerating voltage of 5 kV. .. Raman and photoluminescence (PL) spectra measurement was acquired on a Horiba LabRAM HR Evolution confocal Raman microscope, using a 532 nm laser set to 34 mW, filtered at 1%. ..

    Article Title: Thermally Tunable Fading Memory Enabled by Opto-Ionic-Electronic Coupling in AgInP2S6-Gated Two-Dimensional Field-Effect Transistors.
    Article Snippet: .. Raman spectroscopy of the AgInP2S6 crystals was performed using a Horiba LabRAM HR Evolution confocal Raman microscope with a 532 nm laser and a grating spacing of 1800 gr/mm for Raman spectroscopy and 300 gr/mm for PL spectroscopy. .. Powder X-ray diffraction patterns of synthesized crystals were obtained using a Rigaku MiniFlex 600 X-ray diffraction system equipped with a D/teX silicon 1D detector.

    Raman Spectroscopy:

    Article Title: Raman spectroscopy reveals a novel mechanism by which cyclin Y promotes breast cancer progression by regulating lipid metabolism.
    Article Snippet: .. Raman spectroscopy measurements were conducted by Shanghai D-band Co. (Shanghai, China) using a HORIBA HR Evolution 800 (HORIBA, Paris, France) microscopic Raman spectrometer. ..

    Article Title: Thermally Tunable Fading Memory Enabled by Opto-Ionic-Electronic Coupling in AgInP2S6-Gated Two-Dimensional Field-Effect Transistors.
    Article Snippet: .. Raman spectroscopy of the AgInP2S6 crystals was performed using a Horiba LabRAM HR Evolution confocal Raman microscope with a 532 nm laser and a grating spacing of 1800 gr/mm for Raman spectroscopy and 300 gr/mm for PL spectroscopy. .. Powder X-ray diffraction patterns of synthesized crystals were obtained using a Rigaku MiniFlex 600 X-ray diffraction system equipped with a D/teX silicon 1D detector.

    Article Title: Development of a multi-mineral martian regolith simulant benchmarked against NWA 10153
    Article Snippet: Martian regolith simulants are widely used as proxy materials in laboratory studies of martian surface materials and in situ resource utilization (ISRU).. Orbital and in situ observations provide important constraints on regolith mineralogy and chemistry, but preparing a simulant also requires selecting suitable terrestrial mineral feedstocks.. Because minerals within the same broad group can differ substantially in composition, feedstock selection can affect the mineralogical and chemical characteristics of the resulting simulant.

    Spectroscopy:

    Article Title: Thermally Tunable Fading Memory Enabled by Opto-Ionic-Electronic Coupling in AgInP2S6-Gated Two-Dimensional Field-Effect Transistors.
    Article Snippet: .. Raman spectroscopy of the AgInP2S6 crystals was performed using a Horiba LabRAM HR Evolution confocal Raman microscope with a 532 nm laser and a grating spacing of 1800 gr/mm for Raman spectroscopy and 300 gr/mm for PL spectroscopy. .. Powder X-ray diffraction patterns of synthesized crystals were obtained using a Rigaku MiniFlex 600 X-ray diffraction system equipped with a D/teX silicon 1D detector.



    Similar Products

    94
    Danaher Inc coherent raman microscope
    Coherent Raman Microscope, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/raman+microscope/STELLARIS+8+CRS+Coherent+Raman+Scattering+Microscope/pm42849108-82-6-10
    Average 94 stars, based on 1 article reviews
    coherent raman microscope - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    99
    HORIBA Ltd optical raman microscope
    Optical Raman Microscope, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/raman+microscope/XploRA+PLUS/pmc13684427-150-8-10
    Average 99 stars, based on 1 article reviews
    optical raman microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    HORIBA Ltd xplora plus raman microscope
    Xplora Plus Raman Microscope, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/raman+microscope/XploRA+PLUS/pm42882482-106-6-5
    Average 99 stars, based on 1 article reviews
    xplora plus raman microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Oxford Instruments alpha300r confocal raman microscope
    Alpha300r Confocal Raman Microscope, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/raman+microscope/alpha300/pmc13657018-152-7-6
    Average 99 stars, based on 1 article reviews
    alpha300r confocal raman microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    HORIBA Ltd confocal raman microscope
    Crystal structures from single-crystal X-ray diffraction showing the low- and high-temperature phases of (a) BA 2 SnI 4 at 125 K (structural data from ref ) and 296 K and of (b) DABSnI 4 at 100 and 296 K, determined in this work. Evolution of structural parameters determined from single-crystal XRD structures: (c) interplanar distances between inorganic layers (measured as the distance between iodides in the apical position), (d) in-plan tilt angle (D in ), the out-of-plane tilt angle (D out ), octahedral tilting (D tilt ), and (e) quadratic elongation. See Table S3 for additional details. The structural parameters for BA 2 SnI 4 at 125 K are calculated from the crystal structures reported in ref . Temperature-dependent low-energy <t>Raman</t> spectra of (f) BA 2 SnI 4 measured with a 785 nm laser, with a cutoff filter at 50 cm –1 (after 230 cm –1 , the wavenumbers are multiplied by a factor of 5 for clarity), and (g) DABSnI 4 , measured with 647.1 nm laser excitation. The main spectral changes occurring at the phase transitions are highlighted in the insets.
    Confocal Raman Microscope, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/raman+microscope/XploRA+PLUS/pmc13693382-172-12-15
    Average 99 stars, based on 1 article reviews
    confocal raman microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    HORIBA Ltd laser confocal microscope raman spectrometer
    Crystal structures from single-crystal X-ray diffraction showing the low- and high-temperature phases of (a) BA 2 SnI 4 at 125 K (structural data from ref ) and 296 K and of (b) DABSnI 4 at 100 and 296 K, determined in this work. Evolution of structural parameters determined from single-crystal XRD structures: (c) interplanar distances between inorganic layers (measured as the distance between iodides in the apical position), (d) in-plan tilt angle (D in ), the out-of-plane tilt angle (D out ), octahedral tilting (D tilt ), and (e) quadratic elongation. See Table S3 for additional details. The structural parameters for BA 2 SnI 4 at 125 K are calculated from the crystal structures reported in ref . Temperature-dependent low-energy <t>Raman</t> spectra of (f) BA 2 SnI 4 measured with a 785 nm laser, with a cutoff filter at 50 cm –1 (after 230 cm –1 , the wavenumbers are multiplied by a factor of 5 for clarity), and (g) DABSnI 4 , measured with 647.1 nm laser excitation. The main spectral changes occurring at the phase transitions are highlighted in the insets.
    Laser Confocal Microscope Raman Spectrometer, supplied by HORIBA Ltd, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/raman+microscope/LabRAM+HR+Evolution/pm42863147-117-10-18
    Average 99 stars, based on 1 article reviews
    laser confocal microscope raman spectrometer - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    Image Search Results


    Crystal structures from single-crystal X-ray diffraction showing the low- and high-temperature phases of (a) BA 2 SnI 4 at 125 K (structural data from ref ) and 296 K and of (b) DABSnI 4 at 100 and 296 K, determined in this work. Evolution of structural parameters determined from single-crystal XRD structures: (c) interplanar distances between inorganic layers (measured as the distance between iodides in the apical position), (d) in-plan tilt angle (D in ), the out-of-plane tilt angle (D out ), octahedral tilting (D tilt ), and (e) quadratic elongation. See Table S3 for additional details. The structural parameters for BA 2 SnI 4 at 125 K are calculated from the crystal structures reported in ref . Temperature-dependent low-energy Raman spectra of (f) BA 2 SnI 4 measured with a 785 nm laser, with a cutoff filter at 50 cm –1 (after 230 cm –1 , the wavenumbers are multiplied by a factor of 5 for clarity), and (g) DABSnI 4 , measured with 647.1 nm laser excitation. The main spectral changes occurring at the phase transitions are highlighted in the insets.

    Journal: Journal of the American Chemical Society

    Article Title: Structural Rigidity Enables Amplified Spontaneous Emission in 2D Alkylammonium Tin Perovskites

    doi: 10.1021/jacs.6c14883

    Figure Lengend Snippet: Crystal structures from single-crystal X-ray diffraction showing the low- and high-temperature phases of (a) BA 2 SnI 4 at 125 K (structural data from ref ) and 296 K and of (b) DABSnI 4 at 100 and 296 K, determined in this work. Evolution of structural parameters determined from single-crystal XRD structures: (c) interplanar distances between inorganic layers (measured as the distance between iodides in the apical position), (d) in-plan tilt angle (D in ), the out-of-plane tilt angle (D out ), octahedral tilting (D tilt ), and (e) quadratic elongation. See Table S3 for additional details. The structural parameters for BA 2 SnI 4 at 125 K are calculated from the crystal structures reported in ref . Temperature-dependent low-energy Raman spectra of (f) BA 2 SnI 4 measured with a 785 nm laser, with a cutoff filter at 50 cm –1 (after 230 cm –1 , the wavenumbers are multiplied by a factor of 5 for clarity), and (g) DABSnI 4 , measured with 647.1 nm laser excitation. The main spectral changes occurring at the phase transitions are highlighted in the insets.

    Article Snippet: The Raman spectra of BA 2 SnI 4 were acquired with a confocal Raman microscope (Horiba Xplora Plus, Horiba) equipped with edge filters enabling measurements as close as 50 cm –1 to the Rayleigh line.

    Techniques: Phase Transitions