diode detector-based 2d diode array dosimeter mapcheck2 (Sun Nuclear Corporation)
Structured Review

Diode Detector Based 2d Diode Array Dosimeter Mapcheck2, supplied by Sun Nuclear Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+diode+detector+array+mapcheck2/mapcheck/pmc04577229-46-7-12
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy"
Article Title: A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy
Journal: Radiology and Oncology
doi: 10.1515/raon-2015-0021
Figure Legend Snippet: 2D images of the passing rate based on gamma evaluation for various dosimetric tools. (A) Film, (B) diode array (Mapcheck), (C) ion chamber array (MatriXX), (D) Portal dosimetry.
Techniques Used:
Related Articles
other:Article Title: Development of a quasi-3D dosimeter using radiochromic plastic for patient-specific quality assurance. Article Snippet: Funding information National Research Foundation of Korea (NRF) funded by the Ministry of Education, Grant/Award Number, Grant/Award Number: 2019K1A3A1A80113183; National Research Foundation of Korea (NRF) funded by the Ministry of Science and ICT, Grant/Award Number, Grant/Award Number: 2021R1I1A1A01059845 Abstract Background: Patient-specific QA verification ensures patient safety and treatment by verifying radiation delivery and dose calculations in treatment plans for errors.. However, a two-dimensional (2D) dose distribution is insufficient for detecting information on the three-dimensional (3D) dose delivered to the patient.. In addition, 3D radiochromic plastic dosimeters (RPDs) such as PRESAGE® represent the volume effect in which the dosimeters have different sensitivities according to the size of the dosimeters. Article Title: Outcomes of Stereotactic Radiation Therapy Versus Fractionated Radiation Therapy in 44 Dogs With Pituitary Masses: A Multi-Institutional Retrospective Study (2016-2022). Article Snippet: Although canine pituitary masses (PM) are increasingly treated with stereotactic radiotherapy (SRT), historical literature supports superior outcomes with conventional fullcourse fractionated radiation therapy (FRT).. A multiinstitutional retrospective study was performed, including dogs with PM treated from 2016 to 2022 with SRT (total dose 30 or 35 Gy in 5 daily fractions) or FRT (total dose 50– 54 Gy in 19– 20 daily fractions).. The influence of potential prognostic/predictive factors was assessed, including pituitary: brain height, pituitary: brain volume, sex, age and endocrine status (functional [F] vs. nonfunctional [NF] PM). Article Title: Detecting outliers beyond tolerance limits derived from statistical process control in patient‐specific quality assurance Article Snippet: Although TG218 recommended a true composite measurement for PSQA, PD has been reported to have a better detection of MLC shift errors compared to ArcCheck, , Article Title: Dose delivery uncertainties assessment in the field junction region of craniospinal irradiation with Volumetric Modulated Arc Therapy using a robustness index and experimental dose verification Article Snippet: These outcomes differ from findings of Lee et al. [ ], who showed that MapCHECK and Article Title: Correction Method for Depth and Field Size dependence in Octavius 1000 SRS patient-specific QA Article Snippet: In this context, two-dimensional (2D) array detectors have become fundamental, with systems such as Article Title: Detecting outliers beyond tolerance limits derived from statistical process control in patient-specific quality assurance. Article Snippet: Although TG218 recommended a true composite measurement for PSQA, PD has been reported to have a better detection of MLC shift errors compared to Article Title: Quality assurance for mixed electron-photon beam radiation therapy using treatment log files and MapCHECK. Article Snippet: We thank Mr Bill Simon of Software:Article Title: Quality assurance for mixed electron-photon beam radiation therapy using treatment log files and MapCHECK. Article Snippet: .. Above the detector array, there is a 1.2-cm thick buildup layer made of polycarbonate, which is equivalent to 2 cm of |
