uv vis absorption  (Thermo Fisher)


Bioz Verified Symbol Thermo Fisher is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 91

    Structured Review

    Thermo Fisher uv vis absorption
    Uv Vis Absorption, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 91/100, based on 2 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/uv vis absorption/product/Thermo Fisher
    Average 91 stars, based on 2 article reviews
    Price from $9.99 to $1999.99
    uv vis absorption - by Bioz Stars, 2020-08
    91/100 stars

    Images

    Related Articles

    Concentration Assay:

    Article Title: Magnetic Virus-like Nanoparticles in N. benthamiana Plants: a New Paradigm for Environmental and Agronomic Biotechnological Research
    Article Snippet: .. To find the concentration of BMV proteins, UV-VIS absorption was performed on the protein solution using a NanoDrop® ND-1000 UV-Vis spectrophotometer. .. Absorbance at 280 nm was used to find the concentration of proteins using Lambert-Beer’s law.

    Article Title: Forces during cellular uptake of viruses and nanoparticles at the ventral side
    Article Snippet: .. After the third washing step the pellet was resuspended in 50 μl MilliQ water and the concentration was determined by UV–Vis absorption (NanoDrop ND-1000, Peqlab, Germany) and adjusted to 1 × 1011 particles per ml. .. For non-covalent immobilization via biotin-neutavidin AuNPs were further functionalized with azide-EG3 -biotin (Jena Bioscience, Germany).

    Article Title: Forces during cellular uptake of viruses and nanoparticles at the ventral side
    Article Snippet: .. Protein and dye concentration were quantified by UV–Vis absorption (NanoDrop ND-1000, Peqlab, Germany). .. Degree of labeling was determined to be 1.2, hence the majority of titin-based tension probes bears 1 fluorophore.

    Spectrophotometry:

    Article Title: Cancer Theranostic Nanoparticles Self-Assembled from Amphiphilic Small Molecules with Equilibrium Shift-Induced Renal Clearance
    Article Snippet: .. UV-vis absorption of the sample solutions was measured by using a Thermo Electron-EV300 UV-vis spectrophotometer at room temperature. ..

    Article Title: Enhanced Removal of Antibiotic in Wastewater Using Liquid Nitrogen-Treated Carbon Material: Material Properties and Removal Mechanisms
    Article Snippet: .. Ampicillin solution was mixed with imidazole solution [ ] for 25 min at 60 °C, and then the UV-Vis absorption at 342 nm was recorded by a Nanodrop 2000 UV-Vis spectrophotometer (Nanodrop 2000/2000c, Thermo, Hong Kong, China). .. The absorption value corresponds to the concentration of ampicillin.

    Article Title: Magnetic Virus-like Nanoparticles in N. benthamiana Plants: a New Paradigm for Environmental and Agronomic Biotechnological Research
    Article Snippet: .. To find the concentration of BMV proteins, UV-VIS absorption was performed on the protein solution using a NanoDrop® ND-1000 UV-Vis spectrophotometer. .. Absorbance at 280 nm was used to find the concentration of proteins using Lambert-Beer’s law.

    Article Title: Coping with strong translational noncrystallographic symmetry and extreme anisotropy in molecular replacement with Phaser: human Rab27a
    Article Snippet: .. The protein concentration was determined by UV–Vis absorption at 280 nm using a Nanodrop spectrophotometer (ThermoFisher). .. The locked-active (GTP-bound) form of hRab27aMut was obtained by loading the protein with the nonhydrolysable GTP analogue GppNHp (Jena Bioscience).

    Article Title: Preparation of a mesoporous silica-based nano-vehicle for dual DOX/CPT pH-triggered delivery
    Article Snippet: .. UV–vis absorption and fluorescence spectra were recorded using a Thermo Scientific 300 UV–vis spectrophotometer. .. Fluorescence excitation spectra were recorded on a Hitachi F2500 fluorescence spectrophotometer.

    Fluorescence:

    Article Title: Preparation of a mesoporous silica-based nano-vehicle for dual DOX/CPT pH-triggered delivery
    Article Snippet: .. UV–vis absorption and fluorescence spectra were recorded using a Thermo Scientific 300 UV–vis spectrophotometer. .. Fluorescence excitation spectra were recorded on a Hitachi F2500 fluorescence spectrophotometer.

    Protein Concentration:

    Article Title: Coping with strong translational noncrystallographic symmetry and extreme anisotropy in molecular replacement with Phaser: human Rab27a
    Article Snippet: .. The protein concentration was determined by UV–Vis absorption at 280 nm using a Nanodrop spectrophotometer (ThermoFisher). .. The locked-active (GTP-bound) form of hRab27aMut was obtained by loading the protein with the nonhydrolysable GTP analogue GppNHp (Jena Bioscience).

    Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 93
    Thermo Fisher uv vis spectrophotometry uv vis uv vis absorption spectra
    <t>UV-vis</t> <t>spectra</t> of PEI-Fe 3 O 4 NPs (blue line) and Au@PEI-Fe 3 O 4 NPs (red line). The inset shows the difference between the two curves and the peak at λ = 559 nm from the Au NPs.
    Uv Vis Spectrophotometry Uv Vis Uv Vis Absorption Spectra, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/uv vis spectrophotometry uv vis uv vis absorption spectra/product/Thermo Fisher
    Average 93 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    uv vis spectrophotometry uv vis uv vis absorption spectra - by Bioz Stars, 2020-08
    93/100 stars
      Buy from Supplier

    85
    Thermo Fisher ultraviolet uv vis absorption spectra
    <t>UV-Vis</t> <t>absorption</t> <t>spectra</t> of DNA-AuNP cluster conjugates with different colors. ( A ) UV-Vis absorption spectra of DNA-AuNP cluster conjugates. The concentration of DTT is 800 μM and the concentration of DNA (from a to e) are as follows: 2 nM, 10 nM, 100 nM, 1 μM, and 5 μM. Inset: FESEM image of DNA-AuNP clusters formed by the addition of 5 μM of DNA. ( B ) DNA-AuNP cluster conjugates with different colors. The concentration of DTT is 800 μM, the concentration of DNA from left to right is 10 μM, 5μM, 1μM, 100 nM, 10 nM, and 2 nM.
    Ultraviolet Uv Vis Absorption Spectra, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 85/100, based on 12 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/ultraviolet uv vis absorption spectra/product/Thermo Fisher
    Average 85 stars, based on 12 article reviews
    Price from $9.99 to $1999.99
    ultraviolet uv vis absorption spectra - by Bioz Stars, 2020-08
    85/100 stars
      Buy from Supplier

    91
    Thermo Fisher uv vis absorption spectroscopy spectra
    (a) <t>UV-vis</t> <t>absorption</t> and (b) corresponding derivative <t>spectra</t> for the relevant species before, during, and after MPC modification (CHCl 3 ).
    Uv Vis Absorption Spectroscopy Spectra, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/uv vis absorption spectroscopy spectra/product/Thermo Fisher
    Average 91 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    uv vis absorption spectroscopy spectra - by Bioz Stars, 2020-08
    91/100 stars
      Buy from Supplier

    Image Search Results


    UV-vis spectra of PEI-Fe 3 O 4 NPs (blue line) and Au@PEI-Fe 3 O 4 NPs (red line). The inset shows the difference between the two curves and the peak at λ = 559 nm from the Au NPs.

    Journal: Scientific Reports

    Article Title: Gold-decorated magnetic nanoparticles design for hyperthermia applications and as a potential platform for their surface-functionalization

    doi: 10.1038/s41598-019-40769-2

    Figure Lengend Snippet: UV-vis spectra of PEI-Fe 3 O 4 NPs (blue line) and Au@PEI-Fe 3 O 4 NPs (red line). The inset shows the difference between the two curves and the peak at λ = 559 nm from the Au NPs.

    Article Snippet: UV-vis spectrophotometry (UV-vis) UV-vis absorption spectra of the produced nanoparticles were recorded by two spectrophotometers: 1) Thermo Scientific Evolution 220 Diode Array and 2) Jasco (V670).

    Techniques:

    UV-Vis absorption spectra of DNA-AuNP cluster conjugates with different colors. ( A ) UV-Vis absorption spectra of DNA-AuNP cluster conjugates. The concentration of DTT is 800 μM and the concentration of DNA (from a to e) are as follows: 2 nM, 10 nM, 100 nM, 1 μM, and 5 μM. Inset: FESEM image of DNA-AuNP clusters formed by the addition of 5 μM of DNA. ( B ) DNA-AuNP cluster conjugates with different colors. The concentration of DTT is 800 μM, the concentration of DNA from left to right is 10 μM, 5μM, 1μM, 100 nM, 10 nM, and 2 nM.

    Journal: Nanoscale Research Letters

    Article Title: A facile method for the detection of DNA by using gold nanoparticle probes coupled with dynamic light scattering

    doi: 10.1186/1556-276X-7-564

    Figure Lengend Snippet: UV-Vis absorption spectra of DNA-AuNP cluster conjugates with different colors. ( A ) UV-Vis absorption spectra of DNA-AuNP cluster conjugates. The concentration of DTT is 800 μM and the concentration of DNA (from a to e) are as follows: 2 nM, 10 nM, 100 nM, 1 μM, and 5 μM. Inset: FESEM image of DNA-AuNP clusters formed by the addition of 5 μM of DNA. ( B ) DNA-AuNP cluster conjugates with different colors. The concentration of DTT is 800 μM, the concentration of DNA from left to right is 10 μM, 5μM, 1μM, 100 nM, 10 nM, and 2 nM.

    Article Snippet: Ultraviolet (UV)-Vis absorption spectra were recorded by Thermo Multiskan spectrum (Thermo Fisher Scientific, Tai To-ku, Tokyo, Japan).

    Techniques: Concentration Assay

    Characterization of AuNPs with different sizes. Notes: ( A ) Typical TEM micrograph of AuNPs (15, 50, and 80 nm; scale bars, 100 nm). ( B ) UV/vis absorbance spectra of AuNPs suspension. Abbreviations: AuNPs, gold nanoparticles; TEM, transmission electron microscope; UV/vis, ultraviolet/visible.

    Journal: International Journal of Nanomedicine

    Article Title: Gold nanoparticles enhance TRAIL sensitivity through Drp1-mediated apoptotic and autophagic mitochondrial fission in NSCLC cells

    doi: 10.2147/IJN.S129274

    Figure Lengend Snippet: Characterization of AuNPs with different sizes. Notes: ( A ) Typical TEM micrograph of AuNPs (15, 50, and 80 nm; scale bars, 100 nm). ( B ) UV/vis absorbance spectra of AuNPs suspension. Abbreviations: AuNPs, gold nanoparticles; TEM, transmission electron microscope; UV/vis, ultraviolet/visible.

    Article Snippet: The ultraviolet/visible (UV/vis) absorption spectra of AuNPs were recorded with a Genesys 10s UV/vis spectrophotometer (Thermo Scientific).

    Techniques: Transmission Electron Microscopy, Transmission Assay, Microscopy

    (a) UV-vis absorption and (b) corresponding derivative spectra for the relevant species before, during, and after MPC modification (CHCl 3 ).

    Journal: Chemical Science

    Article Title: Polylysine-grafted Au144 nanoclusters: birth and growth of a healthy surface-plasmon-resonance-like band nanoclusters: birth and growth of a healthy surface-plasmon-resonance-like band †Electronic supplementary information (ESI) available: Full experimental details on methods and syntheses, and further characterization results. See DOI: 10.1039/c6sc05187aClick here for additional data file.

    doi: 10.1039/c6sc05187a

    Figure Lengend Snippet: (a) UV-vis absorption and (b) corresponding derivative spectra for the relevant species before, during, and after MPC modification (CHCl 3 ).

    Article Snippet: UV-vis absorption spectroscopy Spectra were taken with an Evolution 60S UV-Vis spectrophotometer (Thermo Scientific), using standard cuvettes with a path length of 1 or 0.2 cm.

    Techniques: Modification