plasma optical emission spectrometer icp oes  (Thermo Fisher)


Bioz Verified Symbol Thermo Fisher is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 97

    Structured Review

    Thermo Fisher plasma optical emission spectrometer icp oes
    RPCA loadings plot of 111 metabolite signals analyzed by HS-GC/MS, HPLC-MS/MS, and <t>ICP-OES:</t> Amino acids (AA, *), minerals (+), and volatile organic compounds (VOC, ×).
    Plasma Optical Emission Spectrometer Icp Oes, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 97/100, based on 5 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/plasma optical emission spectrometer icp oes/product/Thermo Fisher
    Average 97 stars, based on 5 article reviews
    Price from $9.99 to $1999.99
    plasma optical emission spectrometer icp oes - by Bioz Stars, 2020-03
    97/100 stars

    Images

    1) Product Images from "Earwax metabolomics: An innovative pilot metabolic profiling study for assessing metabolic changes in ewes during periparturition period"

    Article Title: Earwax metabolomics: An innovative pilot metabolic profiling study for assessing metabolic changes in ewes during periparturition period

    Journal: PLoS ONE

    doi: 10.1371/journal.pone.0183538

    RPCA loadings plot of 111 metabolite signals analyzed by HS-GC/MS, HPLC-MS/MS, and ICP-OES: Amino acids (AA, *), minerals (+), and volatile organic compounds (VOC, ×).
    Figure Legend Snippet: RPCA loadings plot of 111 metabolite signals analyzed by HS-GC/MS, HPLC-MS/MS, and ICP-OES: Amino acids (AA, *), minerals (+), and volatile organic compounds (VOC, ×).

    Techniques Used: Gas Chromatography-Mass Spectrometry, High Performance Liquid Chromatography, Mass Spectrometry

    RPCA score plot of 28 earwax samples from Santa Inês sheep using 111 metabolite signals analyzed by HS-GC/MS, HPLC-MS/MS, and ICP-OES: a) Healthy non-pregnant ewes (HNP) (♦), b) Healthy pregnant ewes (HP) (■), and c) Healthy lactating ewes (HL) (▲).
    Figure Legend Snippet: RPCA score plot of 28 earwax samples from Santa Inês sheep using 111 metabolite signals analyzed by HS-GC/MS, HPLC-MS/MS, and ICP-OES: a) Healthy non-pregnant ewes (HNP) (♦), b) Healthy pregnant ewes (HP) (■), and c) Healthy lactating ewes (HL) (▲).

    Techniques Used: Gas Chromatography-Mass Spectrometry, High Performance Liquid Chromatography, Mass Spectrometry

    Dendrogram of hierarchial cluster analysis (HCA) of 28 earwax samples from Santa Inês sheep using 111 metabolite signals analyzed by HS-GC/MS, HPLC-MS/MS, and ICP-OES: a) Healthy non-pregnant ewes (HNP) (red), b) Healthy pregnant ewes (HP) (green), and c) Healthy lactating ewes (HL) (blue).
    Figure Legend Snippet: Dendrogram of hierarchial cluster analysis (HCA) of 28 earwax samples from Santa Inês sheep using 111 metabolite signals analyzed by HS-GC/MS, HPLC-MS/MS, and ICP-OES: a) Healthy non-pregnant ewes (HNP) (red), b) Healthy pregnant ewes (HP) (green), and c) Healthy lactating ewes (HL) (blue).

    Techniques Used: High Content Screening, Gas Chromatography-Mass Spectrometry, High Performance Liquid Chromatography, Mass Spectrometry

    Related Articles

    High Performance Liquid Chromatography:

    Article Title: Earwax metabolomics: An innovative pilot metabolic profiling study for assessing metabolic changes in ewes during periparturition period
    Article Snippet: Analysis of minerals A total of 28 minerals and elements were tested including (Ag, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, P, Pb, S. Sn, Sr, Ti, U, V, Zn, Se, and I) using an inductively coupled plasma optical emission spectrometer (ICP-OES), model 6300 ICAP Duo (Thermo Fisher Scientific, Massachusetts, USA) with the following accessories: tygon tubes, concentric nebulizer, and cyclonic spray chamber core tube 2 mm. .. Samples were used from subjects with the amount of earwax remaining after analysis by HS/GC–MS and high performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS).

    Flow Cytometry:

    Article Title: Efficacy of engineered GO Amberlite XAD-16 picolylamine sorbent for the trace determination of Pb (II) and Cu (II) in fishes by solid phase extraction column coupled with inductively coupled plasma optical emission spectrometry
    Article Snippet: Sample solution containing 5 µg Pb (II) and Cu (II) having pH 5.6 was allowed to pass through the column at a flow rate of 5 mL min−1 . .. For the determination of Pb (II) and Cu (II) an inductively coupled plasma optical emission spectrometer (ICP–OES), Thermo Scientific (iCAP 7000 series, Waltham, USA) was used at the wavelengths 220, 353 and 324.754 nm respectively.

    Article Title: A High-Efficiency CuO/CeO2 Catalyst for Diclofenac Degradation in Fenton-Like System
    Article Snippet: The operation parameters were as follows: the flowing phases were 70% acetonitrile and 30% acetic acid solution (volume fraction was 0.2%), the flow rate was 1 mL/min, the injection volume was 10 μL, and the detection wavelength was 275 nm. .. The leached metal ions were detected by inductively coupled plasma optical emission spectrometer (ICP-OES) (IRIS Intrepid II XSP, ThermoFisher).

    Article Title: The role of macrocyclic compounds in the extraction and possible separation of platinum and rhodium from chloride solutions
    Article Snippet: Apparatus and reagents Aqueous solutions (feed and raffinate solutions) of metal ion concentrations were analyzed using an inductively coupled plasma optical emission spectrometer (ICP-OES) (manufactured by Thermo Scientific, USA, model iCAP 6000 Series). .. The ICP conditions are an Ar gas pressure of 80 psi, RF power of 1350 w, a pump rate of 40 rpm, an auxiliary gas flow rate of 0.5 L/min, a Neb. gas flow rate of 0.5 L/min, a chiller temperature of 24.1 °C, a camera temperature of −46.55 °C, a generator temperature of 31 °C, and an optics temperature of 38.1 °C.

    Filtration:

    Article Title: Recovery of Li(Ni0.33Mn0.33Co0.33)O2 from Lithium-Ion Battery Cathodes: Aspects of Degradation
    Article Snippet: During leaching, suspension samples were collected, and after filtration, the metal concentrations were analyzed by ICP-OES. .. Chemical analysis: An inductively coupled plasma-optical emission spectrometer (ICP-OES) with a dual-view option (iCap 6500 DUO, Thermo Scientific, Dreieich, Germany) was used to determine the elemental composition of the NMC and the concentrations of the dissolved elements.

    Chromatography:

    Article Title: Earwax metabolomics: An innovative pilot metabolic profiling study for assessing metabolic changes in ewes during periparturition period
    Article Snippet: Analysis of minerals A total of 28 minerals and elements were tested including (Ag, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, P, Pb, S. Sn, Sr, Ti, U, V, Zn, Se, and I) using an inductively coupled plasma optical emission spectrometer (ICP-OES), model 6300 ICAP Duo (Thermo Fisher Scientific, Massachusetts, USA) with the following accessories: tygon tubes, concentric nebulizer, and cyclonic spray chamber core tube 2 mm. .. Samples were used from subjects with the amount of earwax remaining after analysis by HS/GC–MS and high performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS).

    Labeling:

    Article Title: Synthesis and Detection of Oxygen-18 Labeled Phosphate
    Article Snippet: Labeled water was added in 10% excess to ensure that the POCl3 reacted completely with water containing 18 O. .. The KH2 PO4 product was diluted with ultrapure water, and the P concentration of this solution was determined using an IRIS Advantage inductively coupled plasma optical emission spectrometer (ICP-OES) (Thermo Jarrell Ash, Franklin, Massachusetts).

    Concentration Assay:

    Article Title: Transcriptome profiling of Puccinellia tenuiflora during seed germination under a long-term saline-alkali stress
    Article Snippet: Moreover, the saline-alkali soil extracts were subjected to overall ion measurements by an inductively coupled plasma-optical emission spectrometer (ICP-OES) and a ThermoFisher ICS-2100 instrument; the contents of 20 major elements are shown in Table . .. Collectively, the physicochemical property analysis of the saline-alkali soil revealed that the high ion concentration and high pH caused by the presence of NaHCO3 salt limited the growth of plants and that the effects of the presence of NaHCO3 salt on the soil environment, such as the nutrient elements necessary for plants growth becoming insoluble and changes in the physicochemical properties and structure of the soil, are also important for the inhibition of plant growth in saline-alkali soils.

    Article Title: Identification of microRNAs in response to aluminum stress in the roots of Tibetan wild barley and cultivated barley
    Article Snippet: .. The concentration of Al in the digested solution was determined by inductively coupled plasma optical emission spectrometer (ICP-OES) (iCAP 6000 series, Thermo Fisher scientific, USA). .. DNA was extracted from shoots according to the instructions of MiniBEST Universal Genomic DNA Extraction Kit Ver.5.0 (TaKaRa, Japan).

    Article Title: A High-Efficiency CuO/CeO2 Catalyst for Diclofenac Degradation in Fenton-Like System
    Article Snippet: The diclofenac concentration in the experiment was analyzed by Thermo Scientific Dionex UltiMate 3000 liquid chromatographt with a C18 column. .. The leached metal ions were detected by inductively coupled plasma optical emission spectrometer (ICP-OES) (IRIS Intrepid II XSP, ThermoFisher).

    Article Title: Synthesis and Detection of Oxygen-18 Labeled Phosphate
    Article Snippet: .. The KH2 PO4 product was diluted with ultrapure water, and the P concentration of this solution was determined using an IRIS Advantage inductively coupled plasma optical emission spectrometer (ICP-OES) (Thermo Jarrell Ash, Franklin, Massachusetts). ..

    Article Title: Surface Properties and Ion Release from Fluoride-Containing Bioactive Glasses Promote Osteoblast Differentiation and Mineralisation in vitro
    Article Snippet: Culture medium samples were diluted by a factor of 10 in dH2 O, and concentrations of calcium and silicon were measured on an inductively coupled plasma – optical emission spectrometer (ICP-OES) (iCAP 6000, Thermo Scientific, Waltham, MA, USA). .. Fluoride concentration was measured using a fluoride-selective electrode (Orion 9609BNWP with Orion pH/ISE meter 710; Thermo Scientific).

    Inhibition:

    Article Title: Transcriptome profiling of Puccinellia tenuiflora during seed germination under a long-term saline-alkali stress
    Article Snippet: Moreover, the saline-alkali soil extracts were subjected to overall ion measurements by an inductively coupled plasma-optical emission spectrometer (ICP-OES) and a ThermoFisher ICS-2100 instrument; the contents of 20 major elements are shown in Table . .. Collectively, the physicochemical property analysis of the saline-alkali soil revealed that the high ion concentration and high pH caused by the presence of NaHCO3 salt limited the growth of plants and that the effects of the presence of NaHCO3 salt on the soil environment, such as the nutrient elements necessary for plants growth becoming insoluble and changes in the physicochemical properties and structure of the soil, are also important for the inhibition of plant growth in saline-alkali soils.

    Mass Spectrometry:

    Article Title: Earwax metabolomics: An innovative pilot metabolic profiling study for assessing metabolic changes in ewes during periparturition period
    Article Snippet: Analysis of minerals A total of 28 minerals and elements were tested including (Ag, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, P, Pb, S. Sn, Sr, Ti, U, V, Zn, Se, and I) using an inductively coupled plasma optical emission spectrometer (ICP-OES), model 6300 ICAP Duo (Thermo Fisher Scientific, Massachusetts, USA) with the following accessories: tygon tubes, concentric nebulizer, and cyclonic spray chamber core tube 2 mm. .. Samples were used from subjects with the amount of earwax remaining after analysis by HS/GC–MS and high performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS).

    Article Title: Elemental stoichiometry and compositions of weevil larvae and two acorn hosts under natural phosphorus variation
    Article Snippet: .. Total C and N concentrations were analyzed with an elemental analysis-stable isotope ratio mass spectrometer (EAI) (Vario ELIII; Elementar, Germany), while total P, S, K, Ca, Mg, Fe, Mn, Zn, Cu, Al and Na were determined with a plasma optical emission spectrometer (ICP-OES) (Iris Advantage 1000; Thermo Jarrell Ash, Franklin, MA) at the Instrumental Analysis Centre of Shanghai Jiao Tong University. ..

    Article Title: Multielement stoichiometry in Quercus variabilis under natural phosphorus variation in subtropical China
    Article Snippet: .. Total C and N (mg g−1 ) were determined with elemental analysis-stable isotope ratio mass spectrometer (Vario ELIII, Elementar, Germany) and total P, S, K, Ca, Mg, Al, Fe, Mn, and Zn with plasma optical emission spectrometer (ICP-OES) (Iris Advantage 1000, Thermo Jarrell Ash, Franklin, MA) at the Analytical and Testing Centre, Shanghai Jiao Tong University. ..

    Ion Chromatography:

    Article Title: Recovery of Li(Ni0.33Mn0.33Co0.33)O2 from Lithium-Ion Battery Cathodes: Aspects of Degradation
    Article Snippet: Chemical analysis: An inductively coupled plasma-optical emission spectrometer (ICP-OES) with a dual-view option (iCap 6500 DUO, Thermo Scientific, Dreieich, Germany) was used to determine the elemental composition of the NMC and the concentrations of the dissolved elements. .. Ion analysis: Concentrations of sulfate ions were determined using ion chromatography (881 compact IC pro, Deutsche METROHM GmbH & Co. KG, Filderstadt, Germany).

    Injection:

    Article Title: Recovery of Li(Ni0.33Mn0.33Co0.33)O2 from Lithium-Ion Battery Cathodes: Aspects of Degradation
    Article Snippet: Chemical analysis: An inductively coupled plasma-optical emission spectrometer (ICP-OES) with a dual-view option (iCap 6500 DUO, Thermo Scientific, Dreieich, Germany) was used to determine the elemental composition of the NMC and the concentrations of the dissolved elements. .. The sample introduction system was equipped with a parallel path nebulizer made of polyether ether ketone (PEEK) (MiraMist, Burgener Inc., Mississauga, ON, Canada), a cyclonic spray chamber (Glass Expansion, Port Melbourne, Victoria, Australia), and a ceramic injection tube (Glass Expansion, Port Melbourne, Victoria, Australia).

    Article Title: A High-Efficiency CuO/CeO2 Catalyst for Diclofenac Degradation in Fenton-Like System
    Article Snippet: The operation parameters were as follows: the flowing phases were 70% acetonitrile and 30% acetic acid solution (volume fraction was 0.2%), the flow rate was 1 mL/min, the injection volume was 10 μL, and the detection wavelength was 275 nm. .. The leached metal ions were detected by inductively coupled plasma optical emission spectrometer (ICP-OES) (IRIS Intrepid II XSP, ThermoFisher).

    other:

    Article Title: Bacillus pumilus increases boron uptake and inhibits rapeseed growth under boron supply irrespective of phosphorus fertilization
    Article Snippet: The shoot digests were then diluted with 20 mL of Millipore water and used for determination of B and P on an inductively coupled plasma–optical emission spectrometer (ICP-OES) (iCAP 7000 Series, Thermo Fischer Scientific, Bremen, Germany) coupled to an ASX-520 autosampler.

    Article Title: Impact of MSWI Bottom Ash Codisposed with MSW on Landfill Stabilization with Different Operational Modes
    Article Snippet: The element concentrations in the solution were determined by Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) (Thermo Electron Corporation IRIS/AP, USA).

    Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99
    Thermo Fisher plasma optical emission spectrometry icp oes
    Elemental sulfur . The elemental sulfur was measured in dried plant material by <t>ICP-OES.</t> Seven-day-old seedlings of the cultivars were mock-inoculated or infected with V. longisporum spores. Plants were grown under full sulfur supply (1 mM MgSO 4 ) and under sulfur limitation (0.025 mM and 0.010 mM MgSO 4 ) in a climate chamber for 14 dpi. Three plants with five leaves fully expanded per treatment were harvested in a diurnal rhythm every 4 h starting 1 h before light was switched on (0–16 h). For measuring the material was dried. Data calculated as mg g −1 DM represent the mean of three dependent technical replicates ± SD. Filled bars represent the mock-inoculated plants (C) grown with 1 mM; 0.025 or 0.01 mM MgSO 4 and the striped bars show the corresponding results of infected plants (INF).
    Plasma Optical Emission Spectrometry Icp Oes, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 2 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/plasma optical emission spectrometry icp oes/product/Thermo Fisher
    Average 99 stars, based on 2 article reviews
    Price from $9.99 to $1999.99
    plasma optical emission spectrometry icp oes - by Bioz Stars, 2020-03
    99/100 stars
      Buy from Supplier

    Image Search Results


    Elemental sulfur . The elemental sulfur was measured in dried plant material by ICP-OES. Seven-day-old seedlings of the cultivars were mock-inoculated or infected with V. longisporum spores. Plants were grown under full sulfur supply (1 mM MgSO 4 ) and under sulfur limitation (0.025 mM and 0.010 mM MgSO 4 ) in a climate chamber for 14 dpi. Three plants with five leaves fully expanded per treatment were harvested in a diurnal rhythm every 4 h starting 1 h before light was switched on (0–16 h). For measuring the material was dried. Data calculated as mg g −1 DM represent the mean of three dependent technical replicates ± SD. Filled bars represent the mock-inoculated plants (C) grown with 1 mM; 0.025 or 0.01 mM MgSO 4 and the striped bars show the corresponding results of infected plants (INF).

    Journal: Frontiers in Plant Science

    Article Title: Brassica napus L. cultivars show a broad variability in their morphology, physiology and metabolite levels in response to sulfur limitations and to pathogen attack

    doi: 10.3389/fpls.2015.00009

    Figure Lengend Snippet: Elemental sulfur . The elemental sulfur was measured in dried plant material by ICP-OES. Seven-day-old seedlings of the cultivars were mock-inoculated or infected with V. longisporum spores. Plants were grown under full sulfur supply (1 mM MgSO 4 ) and under sulfur limitation (0.025 mM and 0.010 mM MgSO 4 ) in a climate chamber for 14 dpi. Three plants with five leaves fully expanded per treatment were harvested in a diurnal rhythm every 4 h starting 1 h before light was switched on (0–16 h). For measuring the material was dried. Data calculated as mg g −1 DM represent the mean of three dependent technical replicates ± SD. Filled bars represent the mock-inoculated plants (C) grown with 1 mM; 0.025 or 0.01 mM MgSO 4 and the striped bars show the corresponding results of infected plants (INF).

    Article Snippet: The samples were analyzed by inductively coupled plasma optical emission spectrometry (ICP-OES) (iCAP 6000 ICP Spectrometer, Thermo Fisher Scientific Corporation).

    Techniques: Infection

    Comparison of different methods to determine the CDX–SPIO20 blood half-life. ( A ) T 2 *-weighted transversal MR images were acquired pre and post injection of CDX–SPIO20 application iv in rats and are shown here at representative time points. ( B ) Signal intensities pre (SI 0 ) and post injection (SI) of the aorta (white circles in A) were analyzed to obtain blood clearance. The first values (white spheres) with constant low signal intensities were not used for the fit. ( C ) R 2 relaxation rates of plasma samples taken from 3 minutes to 360 minutes were determined at 40°C and 1.41 T in a time-domain NMR. ( D ) The iron concentrations in the same plasma samples were measured by ICP–OES. Note: The values were plotted versus time and fitted by single-order kinetics. Abbreviations: CDX, carboxydextran; ICP-OES, inductively coupled plasma optical emission spectroscopy; iv, intravenous; MR, magnetic resonance; R, relaxation rate; SI, signal intensity; SPIO, superparamagnetic iron oxide nanoparticle.

    Journal: International Journal of Nanomedicine

    Article Title: Studying the effect of particle size and coating type on the blood kinetics of superparamagnetic iron oxide nanoparticles

    doi: 10.2147/IJN.S33120

    Figure Lengend Snippet: Comparison of different methods to determine the CDX–SPIO20 blood half-life. ( A ) T 2 *-weighted transversal MR images were acquired pre and post injection of CDX–SPIO20 application iv in rats and are shown here at representative time points. ( B ) Signal intensities pre (SI 0 ) and post injection (SI) of the aorta (white circles in A) were analyzed to obtain blood clearance. The first values (white spheres) with constant low signal intensities were not used for the fit. ( C ) R 2 relaxation rates of plasma samples taken from 3 minutes to 360 minutes were determined at 40°C and 1.41 T in a time-domain NMR. ( D ) The iron concentrations in the same plasma samples were measured by ICP–OES. Note: The values were plotted versus time and fitted by single-order kinetics. Abbreviations: CDX, carboxydextran; ICP-OES, inductively coupled plasma optical emission spectroscopy; iv, intravenous; MR, magnetic resonance; R, relaxation rate; SI, signal intensity; SPIO, superparamagnetic iron oxide nanoparticle.

    Article Snippet: Inductively coupled plasma optical emission spectrometry The iron concentration was determined using an Inductively coupled plasma optical emission spectrometry (ICP–OES) IRIS Advantage ICP (Thermo Fisher Scientific Inc, Waltham, MA).

    Techniques: Injection, Nuclear Magnetic Resonance, Spectroscopy

    The blood half-life is dependent on the particle size and coating material. Notes: SPIOs were injected at a dose of 100 μmol kg −1 , and blood samples were taken pre and post injection up to 360 minutes. The iron concentration was determined in plasma by ICP–OES and used to calculate the half-life. Values represent mean of n ≥ 3 rats. Abbreviations: CDX, carboxydextran; ICP-OES, inductively coupled plasma optical emission spectroscopy; PAA, polyacrylic acid; PEG, polyethylene glycol; SPIO, superparamagnetic iron oxide nanoparticle.

    Journal: International Journal of Nanomedicine

    Article Title: Studying the effect of particle size and coating type on the blood kinetics of superparamagnetic iron oxide nanoparticles

    doi: 10.2147/IJN.S33120

    Figure Lengend Snippet: The blood half-life is dependent on the particle size and coating material. Notes: SPIOs were injected at a dose of 100 μmol kg −1 , and blood samples were taken pre and post injection up to 360 minutes. The iron concentration was determined in plasma by ICP–OES and used to calculate the half-life. Values represent mean of n ≥ 3 rats. Abbreviations: CDX, carboxydextran; ICP-OES, inductively coupled plasma optical emission spectroscopy; PAA, polyacrylic acid; PEG, polyethylene glycol; SPIO, superparamagnetic iron oxide nanoparticle.

    Article Snippet: Inductively coupled plasma optical emission spectrometry The iron concentration was determined using an Inductively coupled plasma optical emission spectrometry (ICP–OES) IRIS Advantage ICP (Thermo Fisher Scientific Inc, Waltham, MA).

    Techniques: Injection, Concentration Assay, Spectroscopy