Review





Similar Products

93
MedChemExpress monobromobimane mbb
Monobromobimane Mbb, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/monobromobimane mbb/product/MedChemExpress
Average 93 stars, based on 1 article reviews
monobromobimane mbb - by Bioz Stars, 2026-03
93/100 stars
  Buy from Supplier

90
BioAqua Pro Ltd polyethylene biocarriers bioaqua mbbr
Polyethylene Biocarriers Bioaqua Mbbr, supplied by BioAqua Pro Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/polyethylene biocarriers bioaqua mbbr/product/BioAqua Pro Ltd
Average 90 stars, based on 1 article reviews
polyethylene biocarriers bioaqua mbbr - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

93
MedChemExpress bromobimane
Bromobimane, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/bromobimane/product/MedChemExpress
Average 93 stars, based on 1 article reviews
bromobimane - by Bioz Stars, 2026-03
93/100 stars
  Buy from Supplier

93
MedChemExpress monobromobimane staining
Monobromobimane Staining, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/monobromobimane staining/product/MedChemExpress
Average 93 stars, based on 1 article reviews
monobromobimane staining - by Bioz Stars, 2026-03
93/100 stars
  Buy from Supplier

90
Tokyo Chemical Industry mbbr
Mbbr, supplied by Tokyo Chemical Industry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/mbbr/product/Tokyo Chemical Industry
Average 90 stars, based on 1 article reviews
mbbr - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

94
MedChemExpress monochlorobimane mbbr
Monochlorobimane Mbbr, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/monochlorobimane mbbr/product/MedChemExpress
Average 94 stars, based on 1 article reviews
monochlorobimane mbbr - by Bioz Stars, 2026-03
94/100 stars
  Buy from Supplier

90
Thermo Fisher monobromobimane (mbbr)
Monobromobimane (Mbbr), supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/monobromobimane (mbbr)/product/Thermo Fisher
Average 90 stars, based on 1 article reviews
monobromobimane (mbbr) - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

93
MedChemExpress monobromodimane mbbr
The concentration of each substance in radish seeds hydrolytic process. ( A – C ) the concentrations of SFE, HS − -SFE product, and Cys-SFE product 2 detected by HPLC analysis with PDA detector; ( D – F ) HS − , Cys, and GSH assayed by HPLC after <t>mBBr</t> derivatization with fluorescence detector. The radish seeds’ powders and PBS buffer were added to a screw-plugged tube at a ratio of 1:10, and the mixture was reacted at 25 °C. At different time intervals, 1 mL of the mixture were taken, centrifuged, and filtered with 0.22 μm filter. Part of the filtrate was used to detect HS − , Cys, and GSH after mBBr derivatization, and others was injected to HPLC to analyze the contents of SFE and its partial degradation products.
Monobromodimane Mbbr, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/monobromodimane mbbr/product/MedChemExpress
Average 93 stars, based on 1 article reviews
monobromodimane mbbr - by Bioz Stars, 2026-03
93/100 stars
  Buy from Supplier

93
MedChemExpress bromobimane medchemexpress
The concentration of each substance in radish seeds hydrolytic process. ( A – C ) the concentrations of SFE, HS − -SFE product, and Cys-SFE product 2 detected by HPLC analysis with PDA detector; ( D – F ) HS − , Cys, and GSH assayed by HPLC after <t>mBBr</t> derivatization with fluorescence detector. The radish seeds’ powders and PBS buffer were added to a screw-plugged tube at a ratio of 1:10, and the mixture was reacted at 25 °C. At different time intervals, 1 mL of the mixture were taken, centrifuged, and filtered with 0.22 μm filter. Part of the filtrate was used to detect HS − , Cys, and GSH after mBBr derivatization, and others was injected to HPLC to analyze the contents of SFE and its partial degradation products.
Bromobimane Medchemexpress, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/bromobimane medchemexpress/product/MedChemExpress
Average 93 stars, based on 1 article reviews
bromobimane medchemexpress - by Bioz Stars, 2026-03
93/100 stars
  Buy from Supplier

Image Search Results


The concentration of each substance in radish seeds hydrolytic process. ( A – C ) the concentrations of SFE, HS − -SFE product, and Cys-SFE product 2 detected by HPLC analysis with PDA detector; ( D – F ) HS − , Cys, and GSH assayed by HPLC after mBBr derivatization with fluorescence detector. The radish seeds’ powders and PBS buffer were added to a screw-plugged tube at a ratio of 1:10, and the mixture was reacted at 25 °C. At different time intervals, 1 mL of the mixture were taken, centrifuged, and filtered with 0.22 μm filter. Part of the filtrate was used to detect HS − , Cys, and GSH after mBBr derivatization, and others was injected to HPLC to analyze the contents of SFE and its partial degradation products.

Journal: Molecules

Article Title: The Effects of Different Thiol-Containing Compounds on the Degradation of Sulforaphene

doi: 10.3390/molecules29184328

Figure Lengend Snippet: The concentration of each substance in radish seeds hydrolytic process. ( A – C ) the concentrations of SFE, HS − -SFE product, and Cys-SFE product 2 detected by HPLC analysis with PDA detector; ( D – F ) HS − , Cys, and GSH assayed by HPLC after mBBr derivatization with fluorescence detector. The radish seeds’ powders and PBS buffer were added to a screw-plugged tube at a ratio of 1:10, and the mixture was reacted at 25 °C. At different time intervals, 1 mL of the mixture were taken, centrifuged, and filtered with 0.22 μm filter. Part of the filtrate was used to detect HS − , Cys, and GSH after mBBr derivatization, and others was injected to HPLC to analyze the contents of SFE and its partial degradation products.

Article Snippet: Monobromodimane (mBBr) was purchased from MedChemExpress LLC (Shanghai, China).

Techniques: Concentration Assay, Fluorescence, Injection

The concentration of each substance in radish seed hydrolytic process with or without sulfide-oxidizing bacteria. ( A – C ) the concentrations of SFE, HS − -SFE product, and Cys-SFE product 2 detected by HPLC analysis with PDA detector; ( D – F ) HS − , Cys, and GSH assayed by HPLC after mBBr derivatization with fluorescence detector. Ten mL OD 600 = 5 Cp wt or Cp ko resuspension was added into 1 g seed powders, respectively. The reaction was carried out at 25 °C for 6 h. At different time intervals, 1 mL mixture were taken, centrifuged, and filtered with 0.22 μm filter. Part of the filtrate was used to detect HS − , Cys, and GSH after mBBr derivatization, and others were injected to HPLC to analyze the contents of SFE and its partial gradation products.

Journal: Molecules

Article Title: The Effects of Different Thiol-Containing Compounds on the Degradation of Sulforaphene

doi: 10.3390/molecules29184328

Figure Lengend Snippet: The concentration of each substance in radish seed hydrolytic process with or without sulfide-oxidizing bacteria. ( A – C ) the concentrations of SFE, HS − -SFE product, and Cys-SFE product 2 detected by HPLC analysis with PDA detector; ( D – F ) HS − , Cys, and GSH assayed by HPLC after mBBr derivatization with fluorescence detector. Ten mL OD 600 = 5 Cp wt or Cp ko resuspension was added into 1 g seed powders, respectively. The reaction was carried out at 25 °C for 6 h. At different time intervals, 1 mL mixture were taken, centrifuged, and filtered with 0.22 μm filter. Part of the filtrate was used to detect HS − , Cys, and GSH after mBBr derivatization, and others were injected to HPLC to analyze the contents of SFE and its partial gradation products.

Article Snippet: Monobromodimane (mBBr) was purchased from MedChemExpress LLC (Shanghai, China).

Techniques: Concentration Assay, Bacteria, Fluorescence, Injection

The concentration of each substance in the hydrolytic process of heat-treatment seeds. ( A – C ) the concentrations of SFE, HS − -SFE product, and Cys-SFE product 2 detected by HPLC analysis with PDA detector; ( D – F ) HS − , Cys, and GSH assayed by HPLC after mBBr derivatization with fluorescence detector. The seed powders and PBS buffer were added to a screw-plugged tube at a ratio of 1:10, and the mixture reacted at 25 °C. At different time intervals, 1 mL of the mixture was taken, centrifuged, and filtered with 0.22 μm filter. Part of the filtrate was used to detect HS − , Cys, and GSH after mBBr derivatization, and others were injected to HPLC to analyze the contents of SFE and its partial degradation products.

Journal: Molecules

Article Title: The Effects of Different Thiol-Containing Compounds on the Degradation of Sulforaphene

doi: 10.3390/molecules29184328

Figure Lengend Snippet: The concentration of each substance in the hydrolytic process of heat-treatment seeds. ( A – C ) the concentrations of SFE, HS − -SFE product, and Cys-SFE product 2 detected by HPLC analysis with PDA detector; ( D – F ) HS − , Cys, and GSH assayed by HPLC after mBBr derivatization with fluorescence detector. The seed powders and PBS buffer were added to a screw-plugged tube at a ratio of 1:10, and the mixture reacted at 25 °C. At different time intervals, 1 mL of the mixture was taken, centrifuged, and filtered with 0.22 μm filter. Part of the filtrate was used to detect HS − , Cys, and GSH after mBBr derivatization, and others were injected to HPLC to analyze the contents of SFE and its partial degradation products.

Article Snippet: Monobromodimane (mBBr) was purchased from MedChemExpress LLC (Shanghai, China).

Techniques: Concentration Assay, Fluorescence, Injection