jasco hplc system  (JASCO Inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99
    Name:
    Preparative HPLC Systems
    Description:
    Large column oven for multiple preparative columns and optional automatic column switching
    Catalog Number:
    preparative-hplc-systems
    Price:
    None
    Category:
    Chromatography HPLC Overview System Configurations Preparative HPLC Systems
    Buy from Supplier


    Structured Review

    JASCO Inc jasco hplc system
    <t>HPLC</t> analysis of acetone-extracted pigments from coupled activity assays. Acetone-extracted samples from the pathway reconstitution experiments shown in A were analyzed on a <t>Jasco</t> HPLC system equipped with an FP-1520 multiwavelength fluorescence
    Large column oven for multiple preparative columns and optional automatic column switching
    https://www.bioz.com/result/jasco hplc system/product/JASCO Inc
    Average 99 stars, based on 292 article reviews
    Price from $9.99 to $1999.99
    jasco hplc system - by Bioz Stars, 2020-11
    99/100 stars

    Images

    1) Product Images from "Broadened Substrate Specificity of 3-Hydroxyethyl Bacteriochlorophyllide a Dehydrogenase (BchC) Indicates a New Route for the Biosynthesis of Bacteriochlorophyll a *"

    Article Title: Broadened Substrate Specificity of 3-Hydroxyethyl Bacteriochlorophyllide a Dehydrogenase (BchC) Indicates a New Route for the Biosynthesis of Bacteriochlorophyll a *

    Journal: The Journal of Biological Chemistry

    doi: 10.1074/jbc.M115.660555

    HPLC analysis of acetone-extracted pigments from coupled activity assays. Acetone-extracted samples from the pathway reconstitution experiments shown in A were analyzed on a Jasco HPLC system equipped with an FP-1520 multiwavelength fluorescence
    Figure Legend Snippet: HPLC analysis of acetone-extracted pigments from coupled activity assays. Acetone-extracted samples from the pathway reconstitution experiments shown in A were analyzed on a Jasco HPLC system equipped with an FP-1520 multiwavelength fluorescence

    Techniques Used: High Performance Liquid Chromatography, Activity Assay, Fluorescence

    Related Articles

    High Performance Liquid Chromatography:

    Article Title: Characterization of Flavonoids and Phenolic Acids in Myrcia bella Cambess. Using FIA-ESI-IT-MSn and HPLC-PAD-ESI-IT-MS Combined with NMR
    Article Snippet: .. HPLC-PAD Analysis Instrumentation The HPLC system consisted of a PU-2089S Plus (Jasco® ) pump equipped with a MD-2015 Plus Photodiode Array Detector (PAD, Jasco® ) and AS-2055 automatic injector (Jasco® ). .. The column was a Luna C18 column (250 × 4.6 mm, i.d.) with a particle size of 5 mm (Phenomenex® ) maintained at 35 °C, and managed by the Jasco ChromPass software.

    Article Title: Hunting modulators of plant defence: the grapevine trunk disease fungus Eutypa lata secretes an amplifier for plant basal immunity
    Article Snippet: .. We therefore fractionated the two filtrates IBWF E16012 (BAF) and IBWF E16012 (PDA) by preparative HPLC, and collected the fractions in 96-well plates. .. The bioactivity of these fractions was then assessed by measuring steady-state transcript levels of genes involved in phytoalexin synthesis (PAL , RS , StSy ) along with JAZ1 as a readout for the activity of basal immunity ( ) in V. rupestris cells as a reporter.

    Article Title: Potential role of cartilage oligomeric matrix protein in the modulation of pulmonary arterial smooth muscle superoxide by hypoxia
    Article Snippet: .. These samples were incubated at −20°C for 1 h. After 1 h samples were centrifuged, and the supernatant was used for HPLC analysis of the superoxide-specific hydroxylated product of MitoSOX (mito-2-hydroxyethidium) or of DHE (2-hydroxyethidium) ( ) using an HPLC system with a Jasco FP-1520 fluorescence detector and a Beckman ultrasphere reverse-phase column (C18, 5 μm, 250 × 4.6 mm; see Ref. ). .. Western blot analysis.

    Article Title: Candida albicans Utilizes a Modified β-Oxidation Pathway for the Degradation of Toxic Propionyl-CoA *
    Article Snippet: .. Quantification of 3-hydroxypropionate was performed using an HPLC system (Jasco, Japan) equipped with a diode array detector and a refractive index detector). .. Samples were chromatographed over an Aminex HPX-87H column (9 μm, 300 × 7.8 mm, Bio-Rad) with 0.005 m H2 SO4 as mobile phase.

    Article Title: Momilactones A, B, and Tricin in Rice Grain and By-Products are Potential Skin Aging Inhibitors
    Article Snippet: .. The amount of tricin in rice grain samples was quantified by the HPLC system which included PU-4180 RHPLC pump, LC-Net II/ADC controller, and UV-4075 UV/Vis detector (Jasco, Tokyo, Japan). .. The stationary phase was XBridge BEH Shield RP18 (130Å, 5 µm, 2.1 × 100 mm) column (Waters Cooperation, Milford, MA, USA).

    Article Title: Degradation of Triphenyltin by a Fluorescent Pseudomonad
    Article Snippet: .. Simultaneous analyses of TPT, DPT, and benzene were done with the same HPLC system and column and were detected using an MD-1510 photodiode array UV-visible light detector (215 to 650 nm) (JASCO). .. The mobile phase used was a 3:5:1:2 (vol/vol/vol/vol) mixture of tetrahydrofuran, doubly-deionized water, methanol, and glacial acetate, and the flow rate was 0.6 ml/min with a 40°C column temperature.

    Article Title: Potential role of mitochondrial superoxide decreasing ferrochelatase and heme in coronary artery soluble guanylate cyclase depletion by angiotensin II
    Article Snippet: .. These samples were incubated at −20°C for 1 h. After 1 h samples were centrifuged, and the supernatant was used for HPLC analysis of the superoxide-specific hydroxylated product of MitoSox (Mito-2-hydroxyethidium) or of dihydroethidine (2-hydroxyethidium) using an HPLC system with a Jasco FP-1520 fluorescence detector and a Beckman ultrasphere reverse column (C18 ) (5μ, 250 × 4.6 mm). .. PpIX fluorescence from BCA rings was measured by a method described previously by our laboratory ( ).

    Article Title: Broadened Substrate Specificity of 3-Hydroxyethyl Bacteriochlorophyllide a Dehydrogenase (BchC) Indicates a New Route for the Biosynthesis of Bacteriochlorophyll a *
    Article Snippet: .. Samples from all pathway reconstitution experiments were analyzed on a Jasco HPLC system equipped with an FP-1520 multiwavelength fluorescence detector using an UltraSep ES RP18 column (SEPSERV) according to a modified method described before ( ). .. Samples of 20 μl were separated at a flow rate of 0.5 ml/min at 30 °C using a linear gradient of 25–100% (v/v) acetonitrile in H2 O containing 0.005% (v/v) triethylamine over 54 min.

    Modification:

    Article Title: Broadened Substrate Specificity of 3-Hydroxyethyl Bacteriochlorophyllide a Dehydrogenase (BchC) Indicates a New Route for the Biosynthesis of Bacteriochlorophyll a *
    Article Snippet: .. Samples from all pathway reconstitution experiments were analyzed on a Jasco HPLC system equipped with an FP-1520 multiwavelength fluorescence detector using an UltraSep ES RP18 column (SEPSERV) according to a modified method described before ( ). .. Samples of 20 μl were separated at a flow rate of 0.5 ml/min at 30 °C using a linear gradient of 25–100% (v/v) acetonitrile in H2 O containing 0.005% (v/v) triethylamine over 54 min.

    Incubation:

    Article Title: Potential role of cartilage oligomeric matrix protein in the modulation of pulmonary arterial smooth muscle superoxide by hypoxia
    Article Snippet: .. These samples were incubated at −20°C for 1 h. After 1 h samples were centrifuged, and the supernatant was used for HPLC analysis of the superoxide-specific hydroxylated product of MitoSOX (mito-2-hydroxyethidium) or of DHE (2-hydroxyethidium) ( ) using an HPLC system with a Jasco FP-1520 fluorescence detector and a Beckman ultrasphere reverse-phase column (C18, 5 μm, 250 × 4.6 mm; see Ref. ). .. Western blot analysis.

    Article Title: Potential role of mitochondrial superoxide decreasing ferrochelatase and heme in coronary artery soluble guanylate cyclase depletion by angiotensin II
    Article Snippet: .. These samples were incubated at −20°C for 1 h. After 1 h samples were centrifuged, and the supernatant was used for HPLC analysis of the superoxide-specific hydroxylated product of MitoSox (Mito-2-hydroxyethidium) or of dihydroethidine (2-hydroxyethidium) using an HPLC system with a Jasco FP-1520 fluorescence detector and a Beckman ultrasphere reverse column (C18 ) (5μ, 250 × 4.6 mm). .. PpIX fluorescence from BCA rings was measured by a method described previously by our laboratory ( ).

    Fluorescence:

    Article Title: Potential role of cartilage oligomeric matrix protein in the modulation of pulmonary arterial smooth muscle superoxide by hypoxia
    Article Snippet: .. These samples were incubated at −20°C for 1 h. After 1 h samples were centrifuged, and the supernatant was used for HPLC analysis of the superoxide-specific hydroxylated product of MitoSOX (mito-2-hydroxyethidium) or of DHE (2-hydroxyethidium) ( ) using an HPLC system with a Jasco FP-1520 fluorescence detector and a Beckman ultrasphere reverse-phase column (C18, 5 μm, 250 × 4.6 mm; see Ref. ). .. Western blot analysis.

    Article Title: Potential role of mitochondrial superoxide decreasing ferrochelatase and heme in coronary artery soluble guanylate cyclase depletion by angiotensin II
    Article Snippet: .. These samples were incubated at −20°C for 1 h. After 1 h samples were centrifuged, and the supernatant was used for HPLC analysis of the superoxide-specific hydroxylated product of MitoSox (Mito-2-hydroxyethidium) or of dihydroethidine (2-hydroxyethidium) using an HPLC system with a Jasco FP-1520 fluorescence detector and a Beckman ultrasphere reverse column (C18 ) (5μ, 250 × 4.6 mm). .. PpIX fluorescence from BCA rings was measured by a method described previously by our laboratory ( ).

    Article Title: Broadened Substrate Specificity of 3-Hydroxyethyl Bacteriochlorophyllide a Dehydrogenase (BchC) Indicates a New Route for the Biosynthesis of Bacteriochlorophyll a *
    Article Snippet: .. Samples from all pathway reconstitution experiments were analyzed on a Jasco HPLC system equipped with an FP-1520 multiwavelength fluorescence detector using an UltraSep ES RP18 column (SEPSERV) according to a modified method described before ( ). .. Samples of 20 μl were separated at a flow rate of 0.5 ml/min at 30 °C using a linear gradient of 25–100% (v/v) acetonitrile in H2 O containing 0.005% (v/v) triethylamine over 54 min.

    Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99
    JASCO Inc jasco hplc system
    <t>HPLC</t> analysis of acetone-extracted pigments from coupled activity assays. Acetone-extracted samples from the pathway reconstitution experiments shown in A were analyzed on a <t>Jasco</t> HPLC system equipped with an FP-1520 multiwavelength fluorescence
    Jasco Hplc System, supplied by JASCO Inc, used in various techniques. Bioz Stars score: 99/100, based on 292 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/jasco hplc system/product/JASCO Inc
    Average 99 stars, based on 292 article reviews
    Price from $9.99 to $1999.99
    jasco hplc system - by Bioz Stars, 2020-11
    99/100 stars
      Buy from Supplier

    88
    JASCO Inc jasco hplc sfc instrument
    Elution profiles for myoglobin fragment peptides through an <t>SFC</t> Waters HILIC column (top), <t>HPLC</t> ProZap™ C 18 column (middle) and HPLC Jupiter™ C 5 column (bottom), with respective retention times of ∼0.5-1.2 min, ∼0.7-1.5
    Jasco Hplc Sfc Instrument, supplied by JASCO Inc, used in various techniques. Bioz Stars score: 88/100, based on 6 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/jasco hplc sfc instrument/product/JASCO Inc
    Average 88 stars, based on 6 article reviews
    Price from $9.99 to $1999.99
    jasco hplc sfc instrument - by Bioz Stars, 2020-11
    88/100 stars
      Buy from Supplier

    93
    JASCO Inc high performance liquid chromatography hplc system jasco extrema lc 4000 system
    Elution profiles for myoglobin fragment peptides through an <t>SFC</t> Waters HILIC column (top), <t>HPLC</t> ProZap™ C 18 column (middle) and HPLC Jupiter™ C 5 column (bottom), with respective retention times of ∼0.5-1.2 min, ∼0.7-1.5
    High Performance Liquid Chromatography Hplc System Jasco Extrema Lc 4000 System, supplied by JASCO Inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/high performance liquid chromatography hplc system jasco extrema lc 4000 system/product/JASCO Inc
    Average 93 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    high performance liquid chromatography hplc system jasco extrema lc 4000 system - by Bioz Stars, 2020-11
    93/100 stars
      Buy from Supplier

    90
    JASCO Inc jasco hplc lc 2000 plus
    Elution profiles for myoglobin fragment peptides through an <t>SFC</t> Waters HILIC column (top), <t>HPLC</t> ProZap™ C 18 column (middle) and HPLC Jupiter™ C 5 column (bottom), with respective retention times of ∼0.5-1.2 min, ∼0.7-1.5
    Jasco Hplc Lc 2000 Plus, supplied by JASCO Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/jasco hplc lc 2000 plus/product/JASCO Inc
    Average 90 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    jasco hplc lc 2000 plus - by Bioz Stars, 2020-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    HPLC analysis of acetone-extracted pigments from coupled activity assays. Acetone-extracted samples from the pathway reconstitution experiments shown in A were analyzed on a Jasco HPLC system equipped with an FP-1520 multiwavelength fluorescence

    Journal: The Journal of Biological Chemistry

    Article Title: Broadened Substrate Specificity of 3-Hydroxyethyl Bacteriochlorophyllide a Dehydrogenase (BchC) Indicates a New Route for the Biosynthesis of Bacteriochlorophyll a *

    doi: 10.1074/jbc.M115.660555

    Figure Lengend Snippet: HPLC analysis of acetone-extracted pigments from coupled activity assays. Acetone-extracted samples from the pathway reconstitution experiments shown in A were analyzed on a Jasco HPLC system equipped with an FP-1520 multiwavelength fluorescence

    Article Snippet: Samples from all pathway reconstitution experiments were analyzed on a Jasco HPLC system equipped with an FP-1520 multiwavelength fluorescence detector using an UltraSep ES RP18 column (SEPSERV) according to a modified method described before ( ).

    Techniques: High Performance Liquid Chromatography, Activity Assay, Fluorescence

    Elution profiles for myoglobin fragment peptides through an SFC Waters HILIC column (top), HPLC ProZap™ C 18 column (middle) and HPLC Jupiter™ C 5 column (bottom), with respective retention times of ∼0.5-1.2 min, ∼0.7-1.5

    Journal: Journal of the American Society for Mass Spectrometry

    Article Title: Fast Reversed-Phase Liquid Chromatography to Reduce Back Exchange and Increase Throughput in H/D Exchange Monitored by FT-ICR Mass Spectrometry

    doi: 10.1016/j.jasms.2008.11.010

    Figure Lengend Snippet: Elution profiles for myoglobin fragment peptides through an SFC Waters HILIC column (top), HPLC ProZap™ C 18 column (middle) and HPLC Jupiter™ C 5 column (bottom), with respective retention times of ∼0.5-1.2 min, ∼0.7-1.5

    Article Snippet: A Jasco HPLC/SFC instrument (Jasco, Easton, MD) was interfaced to the LEAP robot.

    Techniques: Hydrophilic Interaction Liquid Chromatography, High Performance Liquid Chromatography