immunocap singleplex system  (Thermo Fisher)


Bioz Verified Symbol Thermo Fisher is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 89

    Structured Review

    Thermo Fisher immunocap singleplex system
    Immunocap Singleplex System, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 89/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/immunocap singleplex system/product/Thermo Fisher
    Average 89 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    immunocap singleplex system - by Bioz Stars, 2020-04
    89/100 stars

    Related Products / Commonly Used Together

    isu-e
    total-ige standard curve

    Images

    Related Articles

    Fluorescence:

    Article Title: Molecular allergy diagnostics using multiplex assays: methodological and practical considerations for use in research and clinical routine
    Article Snippet: Finally, fluorescence is measured using a microarray scanner. .. The latter are derived heterologously from a total-IgE standard curve, whereas ISU-E are based on calibration using the ImmunoCAP singleplex system (Phadia 250).

    Concentration Assay:

    Article Title: Molecular allergy diagnostics using multiplex assays: methodological and practical considerations for use in research and clinical routine
    Article Snippet: The test results are analyzed with PC-based software and the concentration of sIgE in the sample is calculated providing ISAC standard units (ISU-E). .. The latter are derived heterologously from a total-IgE standard curve, whereas ISU-E are based on calibration using the ImmunoCAP singleplex system (Phadia 250).

    Labeling:

    Article Title: Molecular allergy diagnostics using multiplex assays: methodological and practical considerations for use in research and clinical routine
    Article Snippet: Following incubation, unbound antibodies of other isotypes (IgG, IgA, etc.) and excess unbound fluorescently labeled anti-human IgE antibodies are removed by washing. .. The latter are derived heterologously from a total-IgE standard curve, whereas ISU-E are based on calibration using the ImmunoCAP singleplex system (Phadia 250).

    Microarray:

    Article Title: Molecular allergy diagnostics using multiplex assays: methodological and practical considerations for use in research and clinical routine
    Article Snippet: Finally, fluorescence is measured using a microarray scanner. .. The latter are derived heterologously from a total-IgE standard curve, whereas ISU-E are based on calibration using the ImmunoCAP singleplex system (Phadia 250).

    Incubation:

    Article Title: Molecular allergy diagnostics using multiplex assays: methodological and practical considerations for use in research and clinical routine
    Article Snippet: Following incubation, unbound antibodies of other isotypes (IgG, IgA, etc.) and excess unbound fluorescently labeled anti-human IgE antibodies are removed by washing. .. The latter are derived heterologously from a total-IgE standard curve, whereas ISU-E are based on calibration using the ImmunoCAP singleplex system (Phadia 250).

    Inhibition:

    Article Title: Molecular allergy diagnostics using multiplex assays: methodological and practical considerations for use in research and clinical routine
    Article Snippet: The latter are derived heterologously from a total-IgE standard curve, whereas ISU-E are based on calibration using the ImmunoCAP singleplex system (Phadia 250). .. The ISAC 112 is primarily defined as a semiquantitative method, since, in the manufacturer’s opinion the miniaturization of the assay design the shape of the calibration curve the degree of scattering potential divergent values due to competitive inhibition by competing allergen-specific antibodies of other classes (see below) preclude reliable measurement of the „true“ quantitative concentrations of allergen-specific IgE antibodies.

    Derivative Assay:

    Article Title: Molecular allergy diagnostics using multiplex assays: methodological and practical considerations for use in research and clinical routine
    Article Snippet: .. The latter are derived heterologously from a total-IgE standard curve, whereas ISU-E are based on calibration using the ImmunoCAP singleplex system (Phadia 250). ..

    Software:

    Article Title: Molecular allergy diagnostics using multiplex assays: methodological and practical considerations for use in research and clinical routine
    Article Snippet: The test results are analyzed with PC-based software and the concentration of sIgE in the sample is calculated providing ISAC standard units (ISU-E). .. The latter are derived heterologously from a total-IgE standard curve, whereas ISU-E are based on calibration using the ImmunoCAP singleplex system (Phadia 250).

    Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 92
    Thermo Fisher singleplex
    The shift from extract-based to molecule-based allergy diagnosis. For molecule-based <t>singleplex</t> approaches, the number of tests to be performed can be very high. Allergen microarrays offer the advantage of testing a large panel of molecules in one single test.
    Singleplex, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 92/100, based on 18 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/singleplex/product/Thermo Fisher
    Average 92 stars, based on 18 article reviews
    Price from $9.99 to $1999.99
    singleplex - by Bioz Stars, 2020-04
    92/100 stars
      Buy from Supplier

    96
    Thermo Fisher immunocap system
    Comparison of sIgE results obtained with the <t>ImmunoCAP</t> ISAC test with 8 extract-based ImmunoCAP singelplex tests (n = 101).
    Immunocap System, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 96/100, based on 54 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/immunocap system/product/Thermo Fisher
    Average 96 stars, based on 54 article reviews
    Price from $9.99 to $1999.99
    immunocap system - by Bioz Stars, 2020-04
    96/100 stars
      Buy from Supplier

    88
    Thermo Fisher immunocap singleplex tests
    Comparison of sIgE results obtained with the <t>ImmunoCAP</t> ISAC test with 8 extract-based ImmunoCAP singelplex tests (n = 101).
    Immunocap Singleplex Tests, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 88/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/immunocap singleplex tests/product/Thermo Fisher
    Average 88 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    immunocap singleplex tests - by Bioz Stars, 2020-04
    88/100 stars
      Buy from Supplier

    Image Search Results


    The shift from extract-based to molecule-based allergy diagnosis. For molecule-based singleplex approaches, the number of tests to be performed can be very high. Allergen microarrays offer the advantage of testing a large panel of molecules in one single test.

    Journal: Yonsei Medical Journal

    Article Title: Molecular Approach to Allergy Diagnosis and Therapy

    doi: 10.3349/ymj.2014.55.4.839

    Figure Lengend Snippet: The shift from extract-based to molecule-based allergy diagnosis. For molecule-based singleplex approaches, the number of tests to be performed can be very high. Allergen microarrays offer the advantage of testing a large panel of molecules in one single test.

    Article Snippet: Presently, manufacturers offer molecular allergy diagnosis in singleplex (i.e., Thermo Fisher ImmunoCAP, Siemens ImmuLite, and HyCor HyTec) or multiplex [Thermo Fisher Immuno-Solid phase Allergen Chip (ISAC)] formats; both systems have their advantages and limitations.

    Techniques:

    Comparison of sIgE results obtained with the ImmunoCAP ISAC test with 8 extract-based ImmunoCAP singelplex tests (n = 101).

    Journal: Allergo Journal International

    Article Title: Comparison of molecular and extract-based allergy diagnostics with multiplex and singleplex analysis

    doi: 10.1007/s40629-015-0046-4

    Figure Lengend Snippet: Comparison of sIgE results obtained with the ImmunoCAP ISAC test with 8 extract-based ImmunoCAP singelplex tests (n = 101).

    Article Snippet: IgE Analysis IgE analysis of serum samples was performed (A) traditional extract-based singleplex-testing with the ImmunoCAP system and (B) with the molecular multiplex test ImmunoCAP® ISAC 112 (both Thermo Fisher Scientific, Uppsala, Sweden).

    Techniques: