Review



gc801 proteogreen gglu  (GORYO Chemical)


Bioz Verified Symbol GORYO Chemical is a verified supplier
Bioz Manufacturer Symbol GORYO Chemical manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 92

    Structured Review

    GORYO Chemical gc801 proteogreen gglu
    Gc801 Proteogreen Gglu, supplied by GORYO Chemical, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/gc801 proteogreen gglu/product/GORYO Chemical
    Average 92 stars, based on 1 article reviews
    gc801 proteogreen gglu - by Bioz Stars, 2025-05
    92/100 stars

    Images



    Similar Products

    92
    GORYO Chemical gc801 proteogreen gglu
    Gc801 Proteogreen Gglu, supplied by GORYO Chemical, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/gc801 proteogreen gglu/product/GORYO Chemical
    Average 92 stars, based on 1 article reviews
    gc801 proteogreen gglu - by Bioz Stars, 2025-05
    92/100 stars
      Buy from Supplier

    92
    GORYO Chemical gglu hmrg
    Vital imaging of nasal mucosa after application of <t>gGlu-HMRG</t> demonstrates labeling of OE (A) gGlu-HMRG is hydrolyzed to HMRG by the catalytic activity of GGTs. (B) Fluorescent imaging of nasal whole mounts loaded with 10 μM Glu-HMRG captured before and 5, 15, and 30 min after probe application reveal signal in areas comparable to OE. (C) Relative fluorescence intensity of nasal mucosa of OE vs. RE measured every 5 min after application of gGlu-HMRG. The data are shown as the mean ± SEM (n = 5). Statistical differences were calculated in initial time vs 30 min and initial time vs 60 min ∗p < 0.05. D = dorsal, V = ventral, A = anterior, p = posterior, OB = olfactory bulb, scale bars = 2 mm.
    Gglu Hmrg, supplied by GORYO Chemical, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/gglu hmrg/product/GORYO Chemical
    Average 92 stars, based on 1 article reviews
    gglu hmrg - by Bioz Stars, 2025-05
    92/100 stars
      Buy from Supplier

    92
    goryo chemical gc801

    Gc801, supplied by goryo chemical, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/gc801/product/goryo chemical
    Average 92 stars, based on 1 article reviews
    gc801 - by Bioz Stars, 2025-05
    92/100 stars
      Buy from Supplier

    92
    GORYO Chemical gc801

    Gc801, supplied by GORYO Chemical, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/gc801/product/GORYO Chemical
    Average 92 stars, based on 1 article reviews
    gc801 - by Bioz Stars, 2025-05
    92/100 stars
      Buy from Supplier

    92
    GORYO Chemical γ glutamyl hydroxymethyl rhodamine green ggluhmrg

    γ Glutamyl Hydroxymethyl Rhodamine Green Ggluhmrg, supplied by GORYO Chemical, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/γ glutamyl hydroxymethyl rhodamine green ggluhmrg/product/GORYO Chemical
    Average 92 stars, based on 1 article reviews
    γ glutamyl hydroxymethyl rhodamine green ggluhmrg - by Bioz Stars, 2025-05
    92/100 stars
      Buy from Supplier

    92
    GORYO Chemical proteogreen gglu

    Proteogreen Gglu, supplied by GORYO Chemical, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/proteogreen gglu/product/GORYO Chemical
    Average 92 stars, based on 1 article reviews
    proteogreen gglu - by Bioz Stars, 2025-05
    92/100 stars
      Buy from Supplier

    92
    GORYO Chemical proteogreengglu

    Proteogreengglu, supplied by GORYO Chemical, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/proteogreengglu/product/GORYO Chemical
    Average 92 stars, based on 1 article reviews
    proteogreengglu - by Bioz Stars, 2025-05
    92/100 stars
      Buy from Supplier

    Image Search Results


    Vital imaging of nasal mucosa after application of gGlu-HMRG demonstrates labeling of OE (A) gGlu-HMRG is hydrolyzed to HMRG by the catalytic activity of GGTs. (B) Fluorescent imaging of nasal whole mounts loaded with 10 μM Glu-HMRG captured before and 5, 15, and 30 min after probe application reveal signal in areas comparable to OE. (C) Relative fluorescence intensity of nasal mucosa of OE vs. RE measured every 5 min after application of gGlu-HMRG. The data are shown as the mean ± SEM (n = 5). Statistical differences were calculated in initial time vs 30 min and initial time vs 60 min ∗p < 0.05. D = dorsal, V = ventral, A = anterior, p = posterior, OB = olfactory bulb, scale bars = 2 mm.

    Journal: iScience

    Article Title: Rapid fluorescent vital imaging of olfactory epithelium

    doi: 10.1016/j.isci.2022.104222

    Figure Lengend Snippet: Vital imaging of nasal mucosa after application of gGlu-HMRG demonstrates labeling of OE (A) gGlu-HMRG is hydrolyzed to HMRG by the catalytic activity of GGTs. (B) Fluorescent imaging of nasal whole mounts loaded with 10 μM Glu-HMRG captured before and 5, 15, and 30 min after probe application reveal signal in areas comparable to OE. (C) Relative fluorescence intensity of nasal mucosa of OE vs. RE measured every 5 min after application of gGlu-HMRG. The data are shown as the mean ± SEM (n = 5). Statistical differences were calculated in initial time vs 30 min and initial time vs 60 min ∗p < 0.05. D = dorsal, V = ventral, A = anterior, p = posterior, OB = olfactory bulb, scale bars = 2 mm.

    Article Snippet: gGlu-HMRG (ProteoGREEN-gGlu, Gc801, GORYO CHEMICAL, Sapporo, Japan) was used to detect GGT catalysis via the generation of a fluorescenct product ( ).

    Techniques: Imaging, Labeling, Activity Assay, Fluorescence

    Vital imaging can define areas of neuronal OE regeneration after lesioning (A) Whole mount staining of the nasal cavity from a methimazole/dichlobenil lesioned mouse using PGP 9.5/TUBB4 identifies areas on both the lateral wall and septum where respiratory metaplasia (arrowheads) in previous neuronal OE. D = dorsal, V = ventral, A = anterior, p = posterior, OB = olfactory bulb. Scale bars = 2 mm. (B) A coronal section of the nasal cavity from a methimazole/dichlobenil lesioned mouse demonstrates respiratory metaplasia in the dorsal area of OE (arrows). The arrowhead indicates intracavitary excrescences from the injured OE. Scale bar = 1 mm. (C) Regenerated ventral OE from the boxed area labeled “C” in <xref ref-type=Figure 5 B contains a thick layer of TUJ1 labeled OSNs without TUBB4+ cells. Scale bar = 25 μm. (D) A dorsal region of OE from the boxed area labeled “D” in Figure 5 B is without neurons and is labeled for respiratory cells with TUBB4 antibodies. Scale bar = 25 μm. (E) A cartoon illustrates wholemount staining in a methimazole/dichlobenil-injected mouse with respiratory metaplasia in the dorsal recess of the nasal cavity. (F) Fluorescent imaging of whole mounts incubated with 10 mM coumarin captured before and 30 min after probe application reveals signal in the ventral area of OE but not in dorsal areas of what was formerly OE (arrowheads). (G) Relative fluorescence intensity of dorsal vs. ventral mucosa measured every 5 min after application of coumarin. The data are shown as the mean ± SEM (n = 5). (H) Fluorescent imaging of whole mounts incubated with 10 μM Glu-HMRG captured before and 30 min after probe application again reveals signal in the ventral area of OE but not the dorsal area (arrowheads). (I) Relative fluorescence intensity of dorsal vs. ventral mucosa measured every 5 min after application of gGlu-HMRG. The data are shown as the mean ± SEM (n = 5). D = dorsal, V = ventral, A = anterior, p = posterior, OB = olfactory bulb, scale bars = 2 mm. " width="100%" height="100%">

    Journal: iScience

    Article Title: Rapid fluorescent vital imaging of olfactory epithelium

    doi: 10.1016/j.isci.2022.104222

    Figure Lengend Snippet: Vital imaging can define areas of neuronal OE regeneration after lesioning (A) Whole mount staining of the nasal cavity from a methimazole/dichlobenil lesioned mouse using PGP 9.5/TUBB4 identifies areas on both the lateral wall and septum where respiratory metaplasia (arrowheads) in previous neuronal OE. D = dorsal, V = ventral, A = anterior, p = posterior, OB = olfactory bulb. Scale bars = 2 mm. (B) A coronal section of the nasal cavity from a methimazole/dichlobenil lesioned mouse demonstrates respiratory metaplasia in the dorsal area of OE (arrows). The arrowhead indicates intracavitary excrescences from the injured OE. Scale bar = 1 mm. (C) Regenerated ventral OE from the boxed area labeled “C” in Figure 5 B contains a thick layer of TUJ1 labeled OSNs without TUBB4+ cells. Scale bar = 25 μm. (D) A dorsal region of OE from the boxed area labeled “D” in Figure 5 B is without neurons and is labeled for respiratory cells with TUBB4 antibodies. Scale bar = 25 μm. (E) A cartoon illustrates wholemount staining in a methimazole/dichlobenil-injected mouse with respiratory metaplasia in the dorsal recess of the nasal cavity. (F) Fluorescent imaging of whole mounts incubated with 10 mM coumarin captured before and 30 min after probe application reveals signal in the ventral area of OE but not in dorsal areas of what was formerly OE (arrowheads). (G) Relative fluorescence intensity of dorsal vs. ventral mucosa measured every 5 min after application of coumarin. The data are shown as the mean ± SEM (n = 5). (H) Fluorescent imaging of whole mounts incubated with 10 μM Glu-HMRG captured before and 30 min after probe application again reveals signal in the ventral area of OE but not the dorsal area (arrowheads). (I) Relative fluorescence intensity of dorsal vs. ventral mucosa measured every 5 min after application of gGlu-HMRG. The data are shown as the mean ± SEM (n = 5). D = dorsal, V = ventral, A = anterior, p = posterior, OB = olfactory bulb, scale bars = 2 mm.

    Article Snippet: gGlu-HMRG (ProteoGREEN-gGlu, Gc801, GORYO CHEMICAL, Sapporo, Japan) was used to detect GGT catalysis via the generation of a fluorescenct product ( ).

    Techniques: Imaging, Staining, Labeling, Injection, Incubation, Fluorescence

    Journal: iScience

    Article Title: Rapid fluorescent vital imaging of olfactory epithelium

    doi: 10.1016/j.isci.2022.104222

    Figure Lengend Snippet:

    Article Snippet: gGlu-HMRG (ProteoGREEN-gGlu, Gc801, GORYO CHEMICAL, Sapporo, Japan) was used to detect GGT catalysis via the generation of a fluorescenct product ( ).

    Techniques: Recombinant, Reverse Transcription, SYBR Green Assay, RNA Sequencing Assay, Transgenic Assay, Software, Imaging, Microscopy

    Journal: iScience

    Article Title: Rapid fluorescent vital imaging of olfactory epithelium

    doi: 10.1016/j.isci.2022.104222

    Figure Lengend Snippet:

    Article Snippet: ProteoGREEN™-gGlu , GORYO Chemical, Inc , Cat# GC801.

    Techniques: Recombinant, Reverse Transcription, SYBR Green Assay, RNA Sequencing, Transgenic Assay, Software, Imaging, Microscopy

    Journal: iScience

    Article Title: Rapid fluorescent vital imaging of olfactory epithelium

    doi: 10.1016/j.isci.2022.104222

    Figure Lengend Snippet:

    Article Snippet: ProteoGREEN™-gGlu , GORYO Chemical, Inc , Cat# GC801.

    Techniques: Recombinant, Reverse Transcription, SYBR Green Assay, RNA Sequencing Assay, Transgenic Assay, Software, Imaging, Microscopy