Structured Review

Shimadzu Corporation uplc pad analysis hplc pad analysis
The <t>UPLC-PAD</t> chromatograms of the Yejuhua capsule and its three ingredients by UPLC-PAD analysis. The UPLC-PAD chromatograms of the Yejuhua capsule and its three ingredients. SFEC: supercritical-carbon dioxide fluid extraction of Chrysanthemi Indici Flos (a), PO: Patchouli Oil (b), ZTO: Zedoary Turmeric Oil (c), and YJH: Yejuhua capsule (d). The structures of authentic standard compounds used in the UPLC-PAD analysis (e).
Uplc Pad Analysis Hplc Pad Analysis, supplied by Shimadzu Corporation, used in various techniques. Bioz Stars score: 88/100, based on 2337 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/uplc pad analysis hplc pad analysis/product/Shimadzu Corporation
Average 88 stars, based on 2337 article reviews
Price from $9.99 to $1999.99
uplc pad analysis hplc pad analysis - by Bioz Stars, 2020-09
88/100 stars

Images

1) Product Images from "A Standardized Traditional Chinese Medicine Preparation Named Yejuhua Capsule Ameliorates Lipopolysaccharide-Induced Acute Lung Injury in Mice via Downregulating Toll-Like Receptor 4/Nuclear Factor-κB"

Article Title: A Standardized Traditional Chinese Medicine Preparation Named Yejuhua Capsule Ameliorates Lipopolysaccharide-Induced Acute Lung Injury in Mice via Downregulating Toll-Like Receptor 4/Nuclear Factor-κB

Journal: Evidence-based Complementary and Alternative Medicine : eCAM

doi: 10.1155/2015/264612

The UPLC-PAD chromatograms of the Yejuhua capsule and its three ingredients by UPLC-PAD analysis. The UPLC-PAD chromatograms of the Yejuhua capsule and its three ingredients. SFEC: supercritical-carbon dioxide fluid extraction of Chrysanthemi Indici Flos (a), PO: Patchouli Oil (b), ZTO: Zedoary Turmeric Oil (c), and YJH: Yejuhua capsule (d). The structures of authentic standard compounds used in the UPLC-PAD analysis (e).
Figure Legend Snippet: The UPLC-PAD chromatograms of the Yejuhua capsule and its three ingredients by UPLC-PAD analysis. The UPLC-PAD chromatograms of the Yejuhua capsule and its three ingredients. SFEC: supercritical-carbon dioxide fluid extraction of Chrysanthemi Indici Flos (a), PO: Patchouli Oil (b), ZTO: Zedoary Turmeric Oil (c), and YJH: Yejuhua capsule (d). The structures of authentic standard compounds used in the UPLC-PAD analysis (e).

Techniques Used:

The GC-MS and UPLC-PAD fingerprinting chromatograms of 10 batches of Yejuhua capsule. The GC-MS fingerprinting chromatograms of 10 batches of Yejuhua capsule (a) and the UPLC-PAD fingerprinting chromatograms of 10 batches of Yejuhua capsule (b). YJH131-YJH1310: batch of Yejuhua capsule sample from number 1 to number 10.
Figure Legend Snippet: The GC-MS and UPLC-PAD fingerprinting chromatograms of 10 batches of Yejuhua capsule. The GC-MS fingerprinting chromatograms of 10 batches of Yejuhua capsule (a) and the UPLC-PAD fingerprinting chromatograms of 10 batches of Yejuhua capsule (b). YJH131-YJH1310: batch of Yejuhua capsule sample from number 1 to number 10.

Techniques Used: Gas Chromatography-Mass Spectrometry

2) Product Images from "Regulatory effect of paraprobiotic Lactobacillus gasseri CP2305 on gut environment and function"

Article Title: Regulatory effect of paraprobiotic Lactobacillus gasseri CP2305 on gut environment and function

Journal: Microbial Ecology in Health and Disease

doi: 10.3402/mehd.v27.30259

Changes in the concentrations of fecal p-cresol and tyrosine metabolites throughout the trial. (a) Changes in the concentrations of p-cresol in the stool samples. (b) Changes in the concentrations of fecal tyrosine metabolites, which reflect the sum of the concentrations of phenol, 4-ethylphenol and p-cresol.
Figure Legend Snippet: Changes in the concentrations of fecal p-cresol and tyrosine metabolites throughout the trial. (a) Changes in the concentrations of p-cresol in the stool samples. (b) Changes in the concentrations of fecal tyrosine metabolites, which reflect the sum of the concentrations of phenol, 4-ethylphenol and p-cresol.

Techniques Used:

3) Product Images from "Microbial Populations Associated with Treatment of an Industrial Dye Effluent in an Anaerobic Baffled Reactor"

Article Title: Microbial Populations Associated with Treatment of an Industrial Dye Effluent in an Anaerobic Baffled Reactor

Journal: Applied and Environmental Microbiology

doi: 10.1128/AEM.67.7.3226-3235.2001

ABR performance. (A) Compartment COD levels before addition of the dye waste (days 40 and 55) and just after addition (day 70). (B) TOC levels in compartments 1, 4, and 8 after addition of the dye waste. (C) Profile of color removal in the ABR compartments measured by using absorbance at 500 nm for samples taken on day 100.
Figure Legend Snippet: ABR performance. (A) Compartment COD levels before addition of the dye waste (days 40 and 55) and just after addition (day 70). (B) TOC levels in compartments 1, 4, and 8 after addition of the dye waste. (C) Profile of color removal in the ABR compartments measured by using absorbance at 500 nm for samples taken on day 100.

Techniques Used:

4) Product Images from "Microbial Populations Associated with Treatment of an Industrial Dye Effluent in an Anaerobic Baffled Reactor"

Article Title: Microbial Populations Associated with Treatment of an Industrial Dye Effluent in an Anaerobic Baffled Reactor

Journal: Applied and Environmental Microbiology

doi: 10.1128/AEM.67.7.3226-3235.2001

ABR performance. (A) Compartment COD levels before addition of the dye waste (days 40 and 55) and just after addition (day 70). (B) TOC levels in compartments 1, 4, and 8 after addition of the dye waste. (C) Profile of color removal in the ABR compartments measured by using absorbance at 500 nm for samples taken on day 100.
Figure Legend Snippet: ABR performance. (A) Compartment COD levels before addition of the dye waste (days 40 and 55) and just after addition (day 70). (B) TOC levels in compartments 1, 4, and 8 after addition of the dye waste. (C) Profile of color removal in the ABR compartments measured by using absorbance at 500 nm for samples taken on day 100.

Techniques Used:

5) Product Images from "VITAMIN E IN HUMAN MILK AND ITS RELATION TO THE NUTRITIONAL REQUIREMENT OF THE TERM NEWBORN"

Article Title: VITAMIN E IN HUMAN MILK AND ITS RELATION TO THE NUTRITIONAL REQUIREMENT OF THE TERM NEWBORN

Journal: Revista Paulista de Pediatria

doi: 10.1590/1984-0462/;2017;35;2;00015

Average concentration of alpha-tocopherol in breast milk in different periods of lactation.
Figure Legend Snippet: Average concentration of alpha-tocopherol in breast milk in different periods of lactation.

Techniques Used: Concentration Assay

Related Articles

High Performance Liquid Chromatography:

Article Title: Punica granatum L. Leaf Extract Attenuates Lung Inflammation in Mice with Acute Lung Injury
Article Snippet: .. HPLC-DAD-ESI-IT/MS Analysis The chemical constituents of EAFPg were analyzed in a high-performance liquid chromatography (HPLC) system (LC-10AD, Shimadzu) equipped with a photodiode array detector coupled to an Esquire 3000 Plus ion trap mass spectrometer (Bruker Daltonics, Bremen, Germany), using electrospray ionization (ESI) as previously described [ ]. .. Separation was performed using a Phenomenex Kinetex C-18 column (250 × 4.6 mm, 5 μ m; Torrance, CA, USA).

Article Title: A Standardized Traditional Chinese Medicine Preparation Named Yejuhua Capsule Ameliorates Lipopolysaccharide-Induced Acute Lung Injury in Mice via Downregulating Toll-Like Receptor 4/Nuclear Factor-κB
Article Snippet: .. Apparatus and UPLC-PAD Analysis HPLC-PAD analysis was carried out on a Shimadzu LC-20A HPLC system consisting of a SPD-M20A PDA detector, a LC-20AT pump, a SIL-20AC automatic sampler, a CTO-20A thermostatic column compartment, and a Shimadzu LC-20A software (Shimadzu, Kyoto, Japan). .. The separation was performed on a Phenomenex Synergi Hydro-RP 80A C18 column (2.0 × 150 mm, 4 μ m, Phenomenex Inc., CA, USA) with a flow rate of 0.3 mL/min, temperature at 30°C, and injection volume of 5 μ L. The mobile phase consisted of acetonitrile (A) and 0.05% aqueous phosphoric acid (B) was used with the gradient mode (0–3 min: 15% A→18% A; 3–20 min: 18% A→24% A; 20–30 min: 24% A→28% A; 30–40 min: 28% A→30% A; 40–65 min: 30% A→38% A; 65–70 min: 38% A→46% A; 70–80 min: 46% A→48% A; 80–100 min: 48% A→52% A; 100–103 min: 52% A→62% A; 103–120 min: 62% A→95% A; 120–130 min: 95% A→15% A).

Article Title: Hydroalcoholic extract from Origanum vulgare induces a combined anti-mycobacterial and anti-inflammatory response in innate immune cells
Article Snippet: .. Chromatographic analysis and fractionation of HyE-Ov HyE-Ov was subjected to a qualitative chromatographic analysis by High Performance Liquid Chromatography (HPLC) system, equipped with SPD-M20A Diode Array Detector (DAD) (Shimadzu, Japan). .. The investigations were carried out using a Phenomenex Luna C18(2) column (3 μm x 4.6 mm x 150 mm; 3μm), formic acid 1% (phase A) and methanol (phase B) as solvents and an elution gradient, at flow rate of 0.95 mL/min, set as follows: t0 min (A 85%, B 15%); t20 min (A 65%, B 35%); t55 min (A 10%, B 90%); t68 min (A 85%, B 15%); t70 min (A 85%, B 15%).

Article Title: Association between maternal vitamin E status and alpha‐tocopherol levels in the newborn and colostrum) Association between maternal vitamin E status and alpha‐tocopherol levels in the newborn and colostrum
Article Snippet: .. Alpha‐tocopherol was measured by high‐performance liquid chromatography (HPLC) using a Shimadzu device (Shimadzu, Kyoto, Japan) and a reverse phase C18 column (LiChroCART 250–4, Merck, Darmstadt, Germany). ..

Flow Cytometry:

Article Title: Microbial Populations Associated with Treatment of an Industrial Dye Effluent in an Anaerobic Baffled Reactor
Article Snippet: .. The following parameters were measured in each ABR compartment: pH, COD (determined by the closed reflux colorimetric method [American Public Health Association, 1989]), total organic carbon (TOC) (used instead of COD due to interference from the dye waste; determined with a Shimadzu TOC-5050 apparatus), volatile fatty acids (VFAs; determined with a Shimadzu SCL-10A high-performance liquid chromatograph by using an Aminex column, 0.01 M H2 SO4 carrier at a flow rate of 0.5 ml/min, and an oven temperature of 35°C), compartment headspace gas composition (determined by gas chromatography with a Shimadzu GC-TCD gas chromatograph and a Poropak N column), and color at the maximum absorbance of 500 nm (Shimadzu 1201 spectrophotometer). .. On days 60, 80, and 100 samples of sludge from each compartment of the ABR were collected through a sampling port at the top of each compartment by using a needle and a syringe.

Gas Chromatography:

Article Title: Microbial Populations Associated with Treatment of an Industrial Dye Effluent in an Anaerobic Baffled Reactor
Article Snippet: .. The following parameters were measured in each ABR compartment: pH, COD (determined by the closed reflux colorimetric method [American Public Health Association, 1989]), total organic carbon (TOC) (used instead of COD due to interference from the dye waste; determined with a Shimadzu TOC-5050 apparatus), volatile fatty acids (VFAs; determined with a Shimadzu SCL-10A high-performance liquid chromatograph by using an Aminex column, 0.01 M H2 SO4 carrier at a flow rate of 0.5 ml/min, and an oven temperature of 35°C), compartment headspace gas composition (determined by gas chromatography with a Shimadzu GC-TCD gas chromatograph and a Poropak N column), and color at the maximum absorbance of 500 nm (Shimadzu 1201 spectrophotometer). .. On days 60, 80, and 100 samples of sludge from each compartment of the ABR were collected through a sampling port at the top of each compartment by using a needle and a syringe.

Article Title: Regulatory effect of paraprobiotic Lactobacillus gasseri CP2305 on gut environment and function
Article Snippet: .. Briefly, putrefactive products in the fecal samples, including phenol, 4-ethylphenol, p-cresol, indole, and skatole, were determined through the gas–liquid chromatography apparatus GC-2014 fitted with a flame ionization detector (Shimadzu Corporation, Kyoto, Japan). .. The fecal microbial metabolites were analyzed using an HPLC with a pH indicator (LaChrom Elite; Hitachi High-Technologies Corporation, Tokyo, Japan).

Reflux:

Article Title: Microbial Populations Associated with Treatment of an Industrial Dye Effluent in an Anaerobic Baffled Reactor
Article Snippet: .. The following parameters were measured in each ABR compartment: pH, COD (determined by the closed reflux colorimetric method [American Public Health Association, 1989]), total organic carbon (TOC) (used instead of COD due to interference from the dye waste; determined with a Shimadzu TOC-5050 apparatus), volatile fatty acids (VFAs; determined with a Shimadzu SCL-10A high-performance liquid chromatograph by using an Aminex column, 0.01 M H2 SO4 carrier at a flow rate of 0.5 ml/min, and an oven temperature of 35°C), compartment headspace gas composition (determined by gas chromatography with a Shimadzu GC-TCD gas chromatograph and a Poropak N column), and color at the maximum absorbance of 500 nm (Shimadzu 1201 spectrophotometer). .. On days 60, 80, and 100 samples of sludge from each compartment of the ABR were collected through a sampling port at the top of each compartment by using a needle and a syringe.

Spectrophotometry:

Article Title: Microbial Populations Associated with Treatment of an Industrial Dye Effluent in an Anaerobic Baffled Reactor
Article Snippet: .. The following parameters were measured in each ABR compartment: pH, COD (determined by the closed reflux colorimetric method [American Public Health Association, 1989]), total organic carbon (TOC) (used instead of COD due to interference from the dye waste; determined with a Shimadzu TOC-5050 apparatus), volatile fatty acids (VFAs; determined with a Shimadzu SCL-10A high-performance liquid chromatograph by using an Aminex column, 0.01 M H2 SO4 carrier at a flow rate of 0.5 ml/min, and an oven temperature of 35°C), compartment headspace gas composition (determined by gas chromatography with a Shimadzu GC-TCD gas chromatograph and a Poropak N column), and color at the maximum absorbance of 500 nm (Shimadzu 1201 spectrophotometer). .. On days 60, 80, and 100 samples of sludge from each compartment of the ABR were collected through a sampling port at the top of each compartment by using a needle and a syringe.

other:

Article Title: Advanced redox flow fuel cell using ferric chloride as main catalyst for complete conversion from carbohydrates to electricity
Article Snippet: Measurement of biomass degradation and products During continuous operation of the LCFC, total organic carbon (TOC) of anolyte was analyzed at intervals using a TOC analyzer (TOC-L, Shimadzu, Japan).

Fractionation:

Article Title: Hydroalcoholic extract from Origanum vulgare induces a combined anti-mycobacterial and anti-inflammatory response in innate immune cells
Article Snippet: .. Chromatographic analysis and fractionation of HyE-Ov HyE-Ov was subjected to a qualitative chromatographic analysis by High Performance Liquid Chromatography (HPLC) system, equipped with SPD-M20A Diode Array Detector (DAD) (Shimadzu, Japan). .. The investigations were carried out using a Phenomenex Luna C18(2) column (3 μm x 4.6 mm x 150 mm; 3μm), formic acid 1% (phase A) and methanol (phase B) as solvents and an elution gradient, at flow rate of 0.95 mL/min, set as follows: t0 min (A 85%, B 15%); t20 min (A 65%, B 35%); t55 min (A 10%, B 90%); t68 min (A 85%, B 15%); t70 min (A 85%, B 15%).

Mass Spectrometry:

Article Title: Punica granatum L. Leaf Extract Attenuates Lung Inflammation in Mice with Acute Lung Injury
Article Snippet: .. HPLC-DAD-ESI-IT/MS Analysis The chemical constituents of EAFPg were analyzed in a high-performance liquid chromatography (HPLC) system (LC-10AD, Shimadzu) equipped with a photodiode array detector coupled to an Esquire 3000 Plus ion trap mass spectrometer (Bruker Daltonics, Bremen, Germany), using electrospray ionization (ESI) as previously described [ ]. .. Separation was performed using a Phenomenex Kinetex C-18 column (250 × 4.6 mm, 5 μ m; Torrance, CA, USA).

Software:

Article Title: A Standardized Traditional Chinese Medicine Preparation Named Yejuhua Capsule Ameliorates Lipopolysaccharide-Induced Acute Lung Injury in Mice via Downregulating Toll-Like Receptor 4/Nuclear Factor-κB
Article Snippet: .. Apparatus and UPLC-PAD Analysis HPLC-PAD analysis was carried out on a Shimadzu LC-20A HPLC system consisting of a SPD-M20A PDA detector, a LC-20AT pump, a SIL-20AC automatic sampler, a CTO-20A thermostatic column compartment, and a Shimadzu LC-20A software (Shimadzu, Kyoto, Japan). .. The separation was performed on a Phenomenex Synergi Hydro-RP 80A C18 column (2.0 × 150 mm, 4 μ m, Phenomenex Inc., CA, USA) with a flow rate of 0.3 mL/min, temperature at 30°C, and injection volume of 5 μ L. The mobile phase consisted of acetonitrile (A) and 0.05% aqueous phosphoric acid (B) was used with the gradient mode (0–3 min: 15% A→18% A; 3–20 min: 18% A→24% A; 20–30 min: 24% A→28% A; 30–40 min: 28% A→30% A; 40–65 min: 30% A→38% A; 65–70 min: 38% A→46% A; 70–80 min: 46% A→48% A; 80–100 min: 48% A→52% A; 100–103 min: 52% A→62% A; 103–120 min: 62% A→95% A; 120–130 min: 95% A→15% A).

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 88
    Shimadzu Corporation uplc pad analysis hplc pad analysis
    The <t>UPLC-PAD</t> chromatograms of the Yejuhua capsule and its three ingredients by UPLC-PAD analysis. The UPLC-PAD chromatograms of the Yejuhua capsule and its three ingredients. SFEC: supercritical-carbon dioxide fluid extraction of Chrysanthemi Indici Flos (a), PO: Patchouli Oil (b), ZTO: Zedoary Turmeric Oil (c), and YJH: Yejuhua capsule (d). The structures of authentic standard compounds used in the UPLC-PAD analysis (e).
    Uplc Pad Analysis Hplc Pad Analysis, supplied by Shimadzu Corporation, used in various techniques. Bioz Stars score: 88/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/uplc pad analysis hplc pad analysis/product/Shimadzu Corporation
    Average 88 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    uplc pad analysis hplc pad analysis - by Bioz Stars, 2020-09
    88/100 stars
      Buy from Supplier

    92
    Shimadzu Corporation total organic carbon toc
    ABR performance. (A) Compartment <t>COD</t> levels before addition of the dye waste (days 40 and 55) and just after addition (day 70). (B) <t>TOC</t> levels in compartments 1, 4, and 8 after addition of the dye waste. (C) Profile of color removal in the ABR compartments measured by using absorbance at 500 nm for samples taken on day 100.
    Total Organic Carbon Toc, supplied by Shimadzu Corporation, used in various techniques. Bioz Stars score: 92/100, based on 61 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/total organic carbon toc/product/Shimadzu Corporation
    Average 92 stars, based on 61 article reviews
    Price from $9.99 to $1999.99
    total organic carbon toc - by Bioz Stars, 2020-09
    92/100 stars
      Buy from Supplier

    90
    Shimadzu Corporation gc ms device
    ABR performance. (A) Compartment <t>COD</t> levels before addition of the dye waste (days 40 and 55) and just after addition (day 70). (B) <t>TOC</t> levels in compartments 1, 4, and 8 after addition of the dye waste. (C) Profile of color removal in the ABR compartments measured by using absorbance at 500 nm for samples taken on day 100.
    Gc Ms Device, supplied by Shimadzu Corporation, used in various techniques. Bioz Stars score: 90/100, based on 6 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/gc ms device/product/Shimadzu Corporation
    Average 90 stars, based on 6 article reviews
    Price from $9.99 to $1999.99
    gc ms device - by Bioz Stars, 2020-09
    90/100 stars
      Buy from Supplier

    Image Search Results


    The UPLC-PAD chromatograms of the Yejuhua capsule and its three ingredients by UPLC-PAD analysis. The UPLC-PAD chromatograms of the Yejuhua capsule and its three ingredients. SFEC: supercritical-carbon dioxide fluid extraction of Chrysanthemi Indici Flos (a), PO: Patchouli Oil (b), ZTO: Zedoary Turmeric Oil (c), and YJH: Yejuhua capsule (d). The structures of authentic standard compounds used in the UPLC-PAD analysis (e).

    Journal: Evidence-based Complementary and Alternative Medicine : eCAM

    Article Title: A Standardized Traditional Chinese Medicine Preparation Named Yejuhua Capsule Ameliorates Lipopolysaccharide-Induced Acute Lung Injury in Mice via Downregulating Toll-Like Receptor 4/Nuclear Factor-κB

    doi: 10.1155/2015/264612

    Figure Lengend Snippet: The UPLC-PAD chromatograms of the Yejuhua capsule and its three ingredients by UPLC-PAD analysis. The UPLC-PAD chromatograms of the Yejuhua capsule and its three ingredients. SFEC: supercritical-carbon dioxide fluid extraction of Chrysanthemi Indici Flos (a), PO: Patchouli Oil (b), ZTO: Zedoary Turmeric Oil (c), and YJH: Yejuhua capsule (d). The structures of authentic standard compounds used in the UPLC-PAD analysis (e).

    Article Snippet: Apparatus and UPLC-PAD Analysis HPLC-PAD analysis was carried out on a Shimadzu LC-20A HPLC system consisting of a SPD-M20A PDA detector, a LC-20AT pump, a SIL-20AC automatic sampler, a CTO-20A thermostatic column compartment, and a Shimadzu LC-20A software (Shimadzu, Kyoto, Japan).

    Techniques:

    The GC-MS and UPLC-PAD fingerprinting chromatograms of 10 batches of Yejuhua capsule. The GC-MS fingerprinting chromatograms of 10 batches of Yejuhua capsule (a) and the UPLC-PAD fingerprinting chromatograms of 10 batches of Yejuhua capsule (b). YJH131-YJH1310: batch of Yejuhua capsule sample from number 1 to number 10.

    Journal: Evidence-based Complementary and Alternative Medicine : eCAM

    Article Title: A Standardized Traditional Chinese Medicine Preparation Named Yejuhua Capsule Ameliorates Lipopolysaccharide-Induced Acute Lung Injury in Mice via Downregulating Toll-Like Receptor 4/Nuclear Factor-κB

    doi: 10.1155/2015/264612

    Figure Lengend Snippet: The GC-MS and UPLC-PAD fingerprinting chromatograms of 10 batches of Yejuhua capsule. The GC-MS fingerprinting chromatograms of 10 batches of Yejuhua capsule (a) and the UPLC-PAD fingerprinting chromatograms of 10 batches of Yejuhua capsule (b). YJH131-YJH1310: batch of Yejuhua capsule sample from number 1 to number 10.

    Article Snippet: Apparatus and UPLC-PAD Analysis HPLC-PAD analysis was carried out on a Shimadzu LC-20A HPLC system consisting of a SPD-M20A PDA detector, a LC-20AT pump, a SIL-20AC automatic sampler, a CTO-20A thermostatic column compartment, and a Shimadzu LC-20A software (Shimadzu, Kyoto, Japan).

    Techniques: Gas Chromatography-Mass Spectrometry

    ABR performance. (A) Compartment COD levels before addition of the dye waste (days 40 and 55) and just after addition (day 70). (B) TOC levels in compartments 1, 4, and 8 after addition of the dye waste. (C) Profile of color removal in the ABR compartments measured by using absorbance at 500 nm for samples taken on day 100.

    Journal: Applied and Environmental Microbiology

    Article Title: Microbial Populations Associated with Treatment of an Industrial Dye Effluent in an Anaerobic Baffled Reactor

    doi: 10.1128/AEM.67.7.3226-3235.2001

    Figure Lengend Snippet: ABR performance. (A) Compartment COD levels before addition of the dye waste (days 40 and 55) and just after addition (day 70). (B) TOC levels in compartments 1, 4, and 8 after addition of the dye waste. (C) Profile of color removal in the ABR compartments measured by using absorbance at 500 nm for samples taken on day 100.

    Article Snippet: The following parameters were measured in each ABR compartment: pH, COD (determined by the closed reflux colorimetric method [American Public Health Association, 1989]), total organic carbon (TOC) (used instead of COD due to interference from the dye waste; determined with a Shimadzu TOC-5050 apparatus), volatile fatty acids (VFAs; determined with a Shimadzu SCL-10A high-performance liquid chromatograph by using an Aminex column, 0.01 M H2 SO4 carrier at a flow rate of 0.5 ml/min, and an oven temperature of 35°C), compartment headspace gas composition (determined by gas chromatography with a Shimadzu GC-TCD gas chromatograph and a Poropak N column), and color at the maximum absorbance of 500 nm (Shimadzu 1201 spectrophotometer).

    Techniques: