Structured Review

Agilent technologies gas chromatograph 7890a
Gas Chromatograph 7890a, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 89/100, based on 8 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/gas chromatograph 7890a/product/Agilent technologies
Average 89 stars, based on 8 article reviews
Price from $9.99 to $1999.99
gas chromatograph 7890a - by Bioz Stars, 2020-09
89/100 stars

Images

Related Articles

Gas Chromatography:

Article Title: Exacerbation of substrate toxicity by IPTG in Escherichia coli BL21(DE3) carrying a synthetic metabolic pathway
Article Snippet: .. Gas chromatography and mass spectrometry measurements A Gas Chromatograph 6890 N with a flame ionisation detector (GC-FID) and Gas Chromatograph 7890A and Mass Spectrometer (GC–MS) 5975C MSD (Agilent Technologies Inc., USA), both with the capillary column ZB-FFAP 30 m × 0.25 mm × 0.25 µm (Phenomenex Inc., USA) were used for routine analysis and quantification of TCP and its metabolites or for verification of the presence of individual metabolites from the TCP pathway in selected samples, respectively. .. Samples (2 μl) were injected into the GC with an inlet temperature of 250 °C and split ratio 20:1.

Spectrophotometry:

Article Title: Feijoa Fruit Peel: Micro-morphological Features, Evaluation of Phytochemical Profile, and Biological Properties of Its Essential Oil
Article Snippet: .. GC-FID and GC-MS Analysis Gas chromatographic (GC) analysis was performed on an Agilent gas chromatograph 7890A, equipped with a flame ionization detector (FID) and a mass spectrophotometer (MS) 5975C (Agilent Technologies Santa Clara, CA, USA). ..

Gas Chromatography-Mass Spectrometry:

Article Title: Feijoa Fruit Peel: Micro-morphological Features, Evaluation of Phytochemical Profile, and Biological Properties of Its Essential Oil
Article Snippet: .. GC-FID and GC-MS Analysis Gas chromatographic (GC) analysis was performed on an Agilent gas chromatograph 7890A, equipped with a flame ionization detector (FID) and a mass spectrophotometer (MS) 5975C (Agilent Technologies Santa Clara, CA, USA). ..

Article Title: Novel fast analytical method for indirect determination of MCPD fatty acid esters in edible oils and fats based on simultaneous extraction and derivatization
Article Snippet: .. GC-MS analysis was carried out by Agilent Technologies Gas Chromatograph 7890A coupled with Agilent Technologies Mass Spectrometer 5977C with the separation of analytes on Agilent Technologies chromatographic column DB5-MS (30 m; id: 0.25 mm; film thickness: 0.25 μm, stationary phase: 95% PDMS, 5% phenyl groups) (Agilent Technologies, Santa Clara, CA, USA). ..

Article Title: Evaluation of the Impact of Storage Conditions on the Biogenic Amines Profile in Opened Wine Bottles
Article Snippet: .. GC-MS Analysis A gas chromatograph 7890A (Agilent Technologies, Santa Clara, CA, USA) equipped with an electronically controlled split/splitless injection port was interfaced to an inert mass selective detector (5975C, Agilent Technologies) with electron impact ionization chamber. .. GC separation was performed on ZB-5MS capillary column (30 m × 0.25 mm I.D., 0.25 µm film thickness) (Zebron Phenomenex, Shim-Pol, Warsaw, Poland).

Article Title: Exacerbation of substrate toxicity by IPTG in Escherichia coli BL21(DE3) carrying a synthetic metabolic pathway
Article Snippet: .. Gas chromatography and mass spectrometry measurements A Gas Chromatograph 6890 N with a flame ionisation detector (GC-FID) and Gas Chromatograph 7890A and Mass Spectrometer (GC–MS) 5975C MSD (Agilent Technologies Inc., USA), both with the capillary column ZB-FFAP 30 m × 0.25 mm × 0.25 µm (Phenomenex Inc., USA) were used for routine analysis and quantification of TCP and its metabolites or for verification of the presence of individual metabolites from the TCP pathway in selected samples, respectively. .. Samples (2 μl) were injected into the GC with an inlet temperature of 250 °C and split ratio 20:1.

Article Title: Characterization and genomic analysis of a diesel-degrading bacterium, Acinetobacter calcoaceticus CA16, isolated from Canadian soil
Article Snippet: .. Gas chromatography/mass spectrometry (GC/MS) analysisSamples were run on a gas chromatograph 7890A coupled to a 5975C mass spectrometer (Agilent Technologies Inc. , Santa Clara, CA, USA) that is equipped with a 5% phenyl methyl siloxane column (10 m duraguard + 30 m × 250 μm i.d. ..

other:

Article Title: In Vitro Study and Comparison of Caecal Methanogenesis and Fermentation Pattern in the Brown Hare (Lepus europaeus) and Domestic Rabbit (Oryctolagus cuniculus)
Article Snippet: SCFA Liquid samples were centrifuged at 2,800×g for 20 min and analysed using a gas chromatograph 7890A (Agilent Technologies, Santa Clara, California, USA) equipped with a flame ionisation detector (FID) and an Agilent J & W DB-23 column, with helium as a carrier gas.

Mass Spectrometry:

Article Title: Feijoa Fruit Peel: Micro-morphological Features, Evaluation of Phytochemical Profile, and Biological Properties of Its Essential Oil
Article Snippet: .. GC-FID and GC-MS Analysis Gas chromatographic (GC) analysis was performed on an Agilent gas chromatograph 7890A, equipped with a flame ionization detector (FID) and a mass spectrophotometer (MS) 5975C (Agilent Technologies Santa Clara, CA, USA). ..

Article Title: Novel fast analytical method for indirect determination of MCPD fatty acid esters in edible oils and fats based on simultaneous extraction and derivatization
Article Snippet: .. GC-MS analysis was carried out by Agilent Technologies Gas Chromatograph 7890A coupled with Agilent Technologies Mass Spectrometer 5977C with the separation of analytes on Agilent Technologies chromatographic column DB5-MS (30 m; id: 0.25 mm; film thickness: 0.25 μm, stationary phase: 95% PDMS, 5% phenyl groups) (Agilent Technologies, Santa Clara, CA, USA). ..

Article Title: Exacerbation of substrate toxicity by IPTG in Escherichia coli BL21(DE3) carrying a synthetic metabolic pathway
Article Snippet: .. Gas chromatography and mass spectrometry measurements A Gas Chromatograph 6890 N with a flame ionisation detector (GC-FID) and Gas Chromatograph 7890A and Mass Spectrometer (GC–MS) 5975C MSD (Agilent Technologies Inc., USA), both with the capillary column ZB-FFAP 30 m × 0.25 mm × 0.25 µm (Phenomenex Inc., USA) were used for routine analysis and quantification of TCP and its metabolites or for verification of the presence of individual metabolites from the TCP pathway in selected samples, respectively. .. Samples (2 μl) were injected into the GC with an inlet temperature of 250 °C and split ratio 20:1.

Article Title: Characterization and genomic analysis of a diesel-degrading bacterium, Acinetobacter calcoaceticus CA16, isolated from Canadian soil
Article Snippet: .. Gas chromatography/mass spectrometry (GC/MS) analysisSamples were run on a gas chromatograph 7890A coupled to a 5975C mass spectrometer (Agilent Technologies Inc. , Santa Clara, CA, USA) that is equipped with a 5% phenyl methyl siloxane column (10 m duraguard + 30 m × 250 μm i.d. ..

Injection:

Article Title: Evaluation of the Impact of Storage Conditions on the Biogenic Amines Profile in Opened Wine Bottles
Article Snippet: .. GC-MS Analysis A gas chromatograph 7890A (Agilent Technologies, Santa Clara, CA, USA) equipped with an electronically controlled split/splitless injection port was interfaced to an inert mass selective detector (5975C, Agilent Technologies) with electron impact ionization chamber. .. GC separation was performed on ZB-5MS capillary column (30 m × 0.25 mm I.D., 0.25 µm film thickness) (Zebron Phenomenex, Shim-Pol, Warsaw, Poland).

Article Title: Differentiation potential of fish fins –Effective utilization of the fins as food wastes–
Article Snippet: .. The extract sample (1 μl) was injected into a gas chromatograph 7890A (Agilent Technologies Inc., Santa Clara, CA) equipped with an Omega wax 320 30 m ×0.32 mm. .. Does the regeneration of fish fin tissue occur?

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 84
    Agilent technologies system a gc ms 7890a 5975c
    TIC chromatographic peak area of cyclosarin as a function of its concentration in the solution, measured at the following GC/MS systems: <t>7890A/5975C</t> (A), intuvo 9000/5977B (B), and EM 640 (C).
    System A Gc Ms 7890a 5975c, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 84/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/system a gc ms 7890a 5975c/product/Agilent technologies
    Average 84 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    system a gc ms 7890a 5975c - by Bioz Stars, 2020-09
    84/100 stars
      Buy from Supplier

    89
    Agilent technologies gas chromatography mass spectroscopy gc ms
    <t>Gas</t> <t>chromatography-mass</t> <t>spectroscopy</t> chromatogram of volatile oil of Coleus forskohlii
    Gas Chromatography Mass Spectroscopy Gc Ms, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 89/100, based on 3 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/gas chromatography mass spectroscopy gc ms/product/Agilent technologies
    Average 89 stars, based on 3 article reviews
    Price from $9.99 to $1999.99
    gas chromatography mass spectroscopy gc ms - by Bioz Stars, 2020-09
    89/100 stars
      Buy from Supplier

    91
    Agilent technologies gcms
    a. <t>GCMS</t> spectra of the 10 <t>Ittar</t> samples; b. Cluster hierarchical analysis of the Ittar samples based on their molecule composition; c. Venn diagram analysis of Hexane soluble Ittar molecules for their molecular content; d. Venn diagram analysis of methanol soluble Ittar molecules for their molecular content.
    Gcms, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 91/100, based on 9 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/gcms/product/Agilent technologies
    Average 91 stars, based on 9 article reviews
    Price from $9.99 to $1999.99
    gcms - by Bioz Stars, 2020-09
    91/100 stars
      Buy from Supplier

    90
    Agilent technologies agilent 7890b 5977a gc ms
    The TCA cycle intermediates, pyruvic acid, and lactic acid of IPEC-J2 cells measured by an <t>Agilent</t> <t>7890B-5977A</t> GC-MS equipped with HP-5ms (30 m × 250 μ m × 0.25 μ m) capillary column (Agilent J W, Santa Clara, CA, USA). Cells were treated with 0 (NC) or 800 μ M NAC and 0 or 100 μ M H 2 O 2 , respectively. Data were expressed as means ± SEM of at least three independent experiments. a–c Values with different letters are significantly different ( P
    Agilent 7890b 5977a Gc Ms, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 7 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/agilent 7890b 5977a gc ms/product/Agilent technologies
    Average 90 stars, based on 7 article reviews
    Price from $9.99 to $1999.99
    agilent 7890b 5977a gc ms - by Bioz Stars, 2020-09
    90/100 stars
      Buy from Supplier

    Image Search Results


    TIC chromatographic peak area of cyclosarin as a function of its concentration in the solution, measured at the following GC/MS systems: 7890A/5975C (A), intuvo 9000/5977B (B), and EM 640 (C).

    Journal: Journal of Analytical Methods in Chemistry

    Article Title: Internal Standards for Quantitative Analysis of Chemical Warfare Agents by the GC/MS Method: Nerve Agents

    doi: 10.1155/2020/8857210

    Figure Lengend Snippet: TIC chromatographic peak area of cyclosarin as a function of its concentration in the solution, measured at the following GC/MS systems: 7890A/5975C (A), intuvo 9000/5977B (B), and EM 640 (C).

    Article Snippet: System A—GC/MS 7890A/5975C (Agilent Technologies, Inc., Wilmington, USA); system B—GC/MS Intuvo 9000/5977B same manufacturer; and system C—mobile GC/MS EM 640 (Bruker Daltonik GmbH, Bremen, Germany).

    Techniques: Concentration Assay, Gas Chromatography-Mass Spectrometry

    Examples of soman and triethylphosphate chromatograms extracted at m / z 99 measured on the following GC/MS systems: (a) 7890A/5975C, c CWA = 10.7 mg/L, c ISTD = 15.3 mg/L, (b) intuvo 9000/5977B, c CWA = 7.3 mg/L, c ISTD = 4.3 mg/L, and (c) EM 640, c CWA = 39.0 mg/L, c ISTD = 31.9 mg/L.

    Journal: Journal of Analytical Methods in Chemistry

    Article Title: Internal Standards for Quantitative Analysis of Chemical Warfare Agents by the GC/MS Method: Nerve Agents

    doi: 10.1155/2020/8857210

    Figure Lengend Snippet: Examples of soman and triethylphosphate chromatograms extracted at m / z 99 measured on the following GC/MS systems: (a) 7890A/5975C, c CWA = 10.7 mg/L, c ISTD = 15.3 mg/L, (b) intuvo 9000/5977B, c CWA = 7.3 mg/L, c ISTD = 4.3 mg/L, and (c) EM 640, c CWA = 39.0 mg/L, c ISTD = 31.9 mg/L.

    Article Snippet: System A—GC/MS 7890A/5975C (Agilent Technologies, Inc., Wilmington, USA); system B—GC/MS Intuvo 9000/5977B same manufacturer; and system C—mobile GC/MS EM 640 (Bruker Daltonik GmbH, Bremen, Germany).

    Techniques: Gas Chromatography-Mass Spectrometry

    Gas chromatography-mass spectroscopy chromatogram of volatile oil of Coleus forskohlii

    Journal: Journal of Pharmacy & Bioallied Sciences

    Article Title: Quality control aspects of herbs and botanicals in developing countries: Coleus forskohlii Briq a case study

    doi: 10.4103/0975-7406.168020

    Figure Lengend Snippet: Gas chromatography-mass spectroscopy chromatogram of volatile oil of Coleus forskohlii

    Article Snippet: Pesticide determination Pesticides were analysed in gas chromatography-mass spectroscopy (GC-MS) (Agilent 7890A GC system, USA) by established AOAC official method.

    Techniques: Gas Chromatography, Mass Spectrometry

    a. GCMS spectra of the 10 Ittar samples; b. Cluster hierarchical analysis of the Ittar samples based on their molecule composition; c. Venn diagram analysis of Hexane soluble Ittar molecules for their molecular content; d. Venn diagram analysis of methanol soluble Ittar molecules for their molecular content.

    Journal: bioRxiv

    Article Title: Properties and effect of Ittar in mice behavior and neurological functions

    doi: 10.1101/2019.12.15.876581

    Figure Lengend Snippet: a. GCMS spectra of the 10 Ittar samples; b. Cluster hierarchical analysis of the Ittar samples based on their molecule composition; c. Venn diagram analysis of Hexane soluble Ittar molecules for their molecular content; d. Venn diagram analysis of methanol soluble Ittar molecules for their molecular content.

    Article Snippet: Diluted Ittar samples were injected and analyzed for its various constituents using the GCMS (Agilent 7890, USA) equipped with split injector and auto-sampler attached to capillary column (Agilent 19091S-43; 30m × 0.25 mm) and mass detector (Agilent 5975C series, USA).

    Techniques:

    The TCA cycle intermediates, pyruvic acid, and lactic acid of IPEC-J2 cells measured by an Agilent 7890B-5977A GC-MS equipped with HP-5ms (30 m × 250 μ m × 0.25 μ m) capillary column (Agilent J W, Santa Clara, CA, USA). Cells were treated with 0 (NC) or 800 μ M NAC and 0 or 100 μ M H 2 O 2 , respectively. Data were expressed as means ± SEM of at least three independent experiments. a–c Values with different letters are significantly different ( P

    Journal: Mediators of Inflammation

    Article Title: N-Acetyl-L-cysteine Protects the Enterocyte against Oxidative Damage by Modulation of Mitochondrial Function

    doi: 10.1155/2016/8364279

    Figure Lengend Snippet: The TCA cycle intermediates, pyruvic acid, and lactic acid of IPEC-J2 cells measured by an Agilent 7890B-5977A GC-MS equipped with HP-5ms (30 m × 250 μ m × 0.25 μ m) capillary column (Agilent J W, Santa Clara, CA, USA). Cells were treated with 0 (NC) or 800 μ M NAC and 0 or 100 μ M H 2 O 2 , respectively. Data were expressed as means ± SEM of at least three independent experiments. a–c Values with different letters are significantly different ( P

    Article Snippet: Cells were measured by an Agilent 7890B-5977A GC-MS equipped with HP-5ms (30 m × 250 μ m × 0.25 μ m) capillary column (Agilent J & W, Santa Clara, CA, USA).

    Techniques: Gas Chromatography-Mass Spectrometry