elisa  (Immundiagnostik AG)


Bioz Verified Symbol Immundiagnostik AG is a verified supplier
Bioz Manufacturer Symbol Immundiagnostik AG manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 86

    Structured Review

    Immundiagnostik AG elisa
    Elisa, supplied by Immundiagnostik AG, used in various techniques. Bioz Stars score: 86/100, based on 40 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/elisa/product/Immundiagnostik AG
    Average 86 stars, based on 40 article reviews
    Price from $9.99 to $1999.99
    elisa - by Bioz Stars, 2022-08
    86/100 stars

    Images

    Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 92
    Immundiagnostik AG α1 antitrypsin
    Effects of probiotics are not long-lasting. Graphs show ( A ) fecal concentrations of zonulin (left) and <t>α1-antitrypsin</t> (right); ( B ) fecal concentrations of calprotectin; ( C ) mPASDAS score at baseline, week 12 and 24 following the termination of probiotics treatment; ( D ) Correlations of the change of PASDAS from week 12 to 24 with the frequency of Tregs.
    α1 Antitrypsin, supplied by Immundiagnostik AG, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/α1 antitrypsin/product/Immundiagnostik AG
    Average 92 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    α1 antitrypsin - by Bioz Stars, 2022-08
    92/100 stars
      Buy from Supplier

    80
    Immundiagnostik AG anti sars cov 2 igg elisa
    A systematic analysis of vaccine- and infection-induced humoral <t>SARS-CoV-2</t> immune responses in dialysis patients and kidney transplant recipients. ( A ) SARS-CoV-2 surveillance in SARS-CoV-2-naïve dialysis patients. ( B ) Vaccine-induced humoral response in SARS-CoV-2-naïve dialysis patients. ( C ) Booster shot-induced humoral response in SARS-CoV-2 convalescent dialysis patients. ( D ) Vaccine-induced humoral response in SARS-CoV-2-naïve kidney transplant recipients. Vaccines used: BNT162b2 (BioNTech/Pfizer, Mainz, Germany/New York, NY, USA), mRNA-1273 (Moderna, CA, USA), AZD1222 (AstraZeneca/University of Oxford, Cambridge/Oxford, UK). SARS-CoV-2: severe acute respiratory syndrome coronavirus type 2.
    Anti Sars Cov 2 Igg Elisa, supplied by Immundiagnostik AG, used in various techniques. Bioz Stars score: 80/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/anti sars cov 2 igg elisa/product/Immundiagnostik AG
    Average 80 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    anti sars cov 2 igg elisa - by Bioz Stars, 2022-08
    80/100 stars
      Buy from Supplier

    94
    Immundiagnostik AG idk zonulin elisa kit
    Linear regression and correlation analysis carried out between blood bacterial load and serum <t>zonulin</t> levels. Correlation has been assessed through Pearson’s ( r coefficient), Spearman’s (ρ), and Kendall’s (τ) analyses. Analyses were performed on the first (n = 43, panels A , B,C ) and the second (n = 42, panel D , E,F ) set of blood samples collected from older people. The second set of blood samples was collected approximately four months after the first draw from the same older volunteers. Panels A and D, tables showing correlation and regression indexes and p values. Panels B and E, linear regression plot; vertical dotted lines indicate the quartiles. Panels C and F, Tukey box plots showing levels of bacterial DNAema in blood samples grouped in quartiles based on zonulin level.
    Idk Zonulin Elisa Kit, supplied by Immundiagnostik AG, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/idk zonulin elisa kit/product/Immundiagnostik AG
    Average 94 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    idk zonulin elisa kit - by Bioz Stars, 2022-08
    94/100 stars
      Buy from Supplier

    95
    Immundiagnostik AG elisa kit
    Mean <t>zonulin</t> <t>ELISA</t> values obtained by testing specific candidate target proteins and patients’ serum samples. This ELISA kit did not detect increasing concentrations (range 1-50 μg/ml) of complement, recombinant zonulin (pre-HP2), mature HP1 or mature HP2. Conversely, a strong signal was detected in sera of both celiac disease patients (CD) and healthy controls (non-CD, internal control AF with HP2-2), irrespective of their HP genotype. All samples are technical triplicates, kit controls are shown for comparison.
    Elisa Kit, supplied by Immundiagnostik AG, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/elisa kit/product/Immundiagnostik AG
    Average 95 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    elisa kit - by Bioz Stars, 2022-08
    95/100 stars
      Buy from Supplier

    Image Search Results


    Effects of probiotics are not long-lasting. Graphs show ( A ) fecal concentrations of zonulin (left) and α1-antitrypsin (right); ( B ) fecal concentrations of calprotectin; ( C ) mPASDAS score at baseline, week 12 and 24 following the termination of probiotics treatment; ( D ) Correlations of the change of PASDAS from week 12 to 24 with the frequency of Tregs.

    Journal: Nutrients

    Article Title: Effects of Probiotic Strains on Disease Activity and Enteric Permeability in Psoriatic Arthritis–A Pilot Open-Label Study

    doi: 10.3390/nu12082337

    Figure Lengend Snippet: Effects of probiotics are not long-lasting. Graphs show ( A ) fecal concentrations of zonulin (left) and α1-antitrypsin (right); ( B ) fecal concentrations of calprotectin; ( C ) mPASDAS score at baseline, week 12 and 24 following the termination of probiotics treatment; ( D ) Correlations of the change of PASDAS from week 12 to 24 with the frequency of Tregs.

    Article Snippet: Calprotectin, α1-antitrypsin and zonulin concentrations were determined by using enzyme-linked immunosorbent assay (ELISA) kits (Immundiagnostik AG, Bensheim, Germany, K 6927 (calprotectin); K 6750 (α1-antitrypsin); K 5600 (zonulin)).

    Techniques:

    Intestinal permeability is increased in PsA patients and ameliorates with probiotics intake. ( A ) Heatmap showing too low (dark blue), normal (light blue) and too high (pink) levels of markers of gut permeability (zonulin and α1-antitrypsin) and intestinal inflammation (calprotectin) in PsA patients; Graphs show ( B ) fecal concentrations of zonulin (left) and α1-antitrypsin (right); ( C ) fecal concentrations of calprotectin at baseline (0) and week 12 of treatment with probiotics.

    Journal: Nutrients

    Article Title: Effects of Probiotic Strains on Disease Activity and Enteric Permeability in Psoriatic Arthritis–A Pilot Open-Label Study

    doi: 10.3390/nu12082337

    Figure Lengend Snippet: Intestinal permeability is increased in PsA patients and ameliorates with probiotics intake. ( A ) Heatmap showing too low (dark blue), normal (light blue) and too high (pink) levels of markers of gut permeability (zonulin and α1-antitrypsin) and intestinal inflammation (calprotectin) in PsA patients; Graphs show ( B ) fecal concentrations of zonulin (left) and α1-antitrypsin (right); ( C ) fecal concentrations of calprotectin at baseline (0) and week 12 of treatment with probiotics.

    Article Snippet: Calprotectin, α1-antitrypsin and zonulin concentrations were determined by using enzyme-linked immunosorbent assay (ELISA) kits (Immundiagnostik AG, Bensheim, Germany, K 6927 (calprotectin); K 6750 (α1-antitrypsin); K 5600 (zonulin)).

    Techniques: Permeability

    A systematic analysis of vaccine- and infection-induced humoral SARS-CoV-2 immune responses in dialysis patients and kidney transplant recipients. ( A ) SARS-CoV-2 surveillance in SARS-CoV-2-naïve dialysis patients. ( B ) Vaccine-induced humoral response in SARS-CoV-2-naïve dialysis patients. ( C ) Booster shot-induced humoral response in SARS-CoV-2 convalescent dialysis patients. ( D ) Vaccine-induced humoral response in SARS-CoV-2-naïve kidney transplant recipients. Vaccines used: BNT162b2 (BioNTech/Pfizer, Mainz, Germany/New York, NY, USA), mRNA-1273 (Moderna, CA, USA), AZD1222 (AstraZeneca/University of Oxford, Cambridge/Oxford, UK). SARS-CoV-2: severe acute respiratory syndrome coronavirus type 2.

    Journal: Microorganisms

    Article Title: Immune Responses to SARS-CoV-2 Infection and Vaccination in Dialysis Patients and Kidney Transplant Recipients

    doi: 10.3390/microorganisms10010004

    Figure Lengend Snippet: A systematic analysis of vaccine- and infection-induced humoral SARS-CoV-2 immune responses in dialysis patients and kidney transplant recipients. ( A ) SARS-CoV-2 surveillance in SARS-CoV-2-naïve dialysis patients. ( B ) Vaccine-induced humoral response in SARS-CoV-2-naïve dialysis patients. ( C ) Booster shot-induced humoral response in SARS-CoV-2 convalescent dialysis patients. ( D ) Vaccine-induced humoral response in SARS-CoV-2-naïve kidney transplant recipients. Vaccines used: BNT162b2 (BioNTech/Pfizer, Mainz, Germany/New York, NY, USA), mRNA-1273 (Moderna, CA, USA), AZD1222 (AstraZeneca/University of Oxford, Cambridge/Oxford, UK). SARS-CoV-2: severe acute respiratory syndrome coronavirus type 2.

    Article Snippet: Anti-SARS-CoV-2 IgG targeting the spike (S) protein was detected by the semiquantitative Euroimmun anti-SARS-CoV-2 IgG ELISA using the Euroimmun Analyzer I (Euroimmun Diagnostik, Lübeck, Germany), and by the quantitative IDK® anti-SARS-CoV-2 IgG ELISA (Immundiagnostik AG, Bensheim, Germany) using the DYNEX DSX® (Dynex Technologies, Chantilly, VA, USA), both using the recombinant S1 antigen of the spike protein, or the chemiluminescent microparticle immunoassay by Abbott for the quantitative detection of anti-spike RBD (receptor binding domain) IgG (SARS-CoV-2 IgG II Quant) using the automated system Alinity i (Abbott, Abbott Park, IL, USA).

    Techniques: Infection

    Vaccine- and infection-induced humoral response quantified by anti-SARS-CoV-2 IgG titers in dialysis patients compared to vaccinated healthy individuals. ( A ) Vaccine-induced anti-SARS-CoV-2 IgG titers in dialysis patients differ significantly between dialysis patients immunized by BNT162b2, mRNA-1273, and AZD1222 compared to the reference cohort of mRNA-1273 vaccinated healthy individuals. ( B ) Infection induced anti-SARS-CoV-2 IgG titers in convalescent dialysis patients with (w) and without (w/o) booster shot immunization using BNT162b2 mRNA are reduced compared to vaccine-induced titer in healthy individuals. ( C ) Booster shot-induced anti-SARS-CoV-2 IgG titers in SARS-CoV-2-recovered dialysis patients are elevated compared to mRNA vaccine-induced titers in SARS-CoV-2-naïve dialysis patients. Vaccines used: BNT162b2 (BioNTech/Pfizer, Mainz, Germany/New York, NY, USA), mRNA-1273 (Moderna, CA, Unites States), and AZD1222 (AstraZeneca/University of Oxford, Cambridge/Oxford, UK) in dialysis patients; mRNA-1273 (Moderna, CA, Unites States) in healthy individuals. A Kruskal-Wallis test across all groups was used to indicated differences to healthy individuals. Mann–Whitney U test was used to indicated differences between two groups (*** p

    Journal: Microorganisms

    Article Title: Immune Responses to SARS-CoV-2 Infection and Vaccination in Dialysis Patients and Kidney Transplant Recipients

    doi: 10.3390/microorganisms10010004

    Figure Lengend Snippet: Vaccine- and infection-induced humoral response quantified by anti-SARS-CoV-2 IgG titers in dialysis patients compared to vaccinated healthy individuals. ( A ) Vaccine-induced anti-SARS-CoV-2 IgG titers in dialysis patients differ significantly between dialysis patients immunized by BNT162b2, mRNA-1273, and AZD1222 compared to the reference cohort of mRNA-1273 vaccinated healthy individuals. ( B ) Infection induced anti-SARS-CoV-2 IgG titers in convalescent dialysis patients with (w) and without (w/o) booster shot immunization using BNT162b2 mRNA are reduced compared to vaccine-induced titer in healthy individuals. ( C ) Booster shot-induced anti-SARS-CoV-2 IgG titers in SARS-CoV-2-recovered dialysis patients are elevated compared to mRNA vaccine-induced titers in SARS-CoV-2-naïve dialysis patients. Vaccines used: BNT162b2 (BioNTech/Pfizer, Mainz, Germany/New York, NY, USA), mRNA-1273 (Moderna, CA, Unites States), and AZD1222 (AstraZeneca/University of Oxford, Cambridge/Oxford, UK) in dialysis patients; mRNA-1273 (Moderna, CA, Unites States) in healthy individuals. A Kruskal-Wallis test across all groups was used to indicated differences to healthy individuals. Mann–Whitney U test was used to indicated differences between two groups (*** p

    Article Snippet: Anti-SARS-CoV-2 IgG targeting the spike (S) protein was detected by the semiquantitative Euroimmun anti-SARS-CoV-2 IgG ELISA using the Euroimmun Analyzer I (Euroimmun Diagnostik, Lübeck, Germany), and by the quantitative IDK® anti-SARS-CoV-2 IgG ELISA (Immundiagnostik AG, Bensheim, Germany) using the DYNEX DSX® (Dynex Technologies, Chantilly, VA, USA), both using the recombinant S1 antigen of the spike protein, or the chemiluminescent microparticle immunoassay by Abbott for the quantitative detection of anti-spike RBD (receptor binding domain) IgG (SARS-CoV-2 IgG II Quant) using the automated system Alinity i (Abbott, Abbott Park, IL, USA).

    Techniques: Infection, MANN-WHITNEY

    Vaccine-induced humoral response quantified by anti-SARS-CoV-2 IgG titers in kidney transplant recipients and healthy individuals. ( A ) Vaccine-induced anti-SARS-CoV-2 IgG titers in kidney transplant recipients are impaired compared to healthy individuals. ( B ) Vaccine-induced anti-SARS-CoV-2 IgG titers are significantly elevated in kidney transplant recipients with immunosuppression lacking mycophenolate mofetil/mycophenolic acid. Vaccines used: BNT162b2 (BioNTech/Pfizer Mainz, Germany/New York, NY, USA) in kidney transplant recipients, and mRNA-1273 (Moderna, CA, United States) in healthy individuals. A Kruskal–Wallis test across all groups was used to indicate differences with respect to healthy individuals. A Mann–Whitney U test was used to indicate differences between two groups (**** p

    Journal: Microorganisms

    Article Title: Immune Responses to SARS-CoV-2 Infection and Vaccination in Dialysis Patients and Kidney Transplant Recipients

    doi: 10.3390/microorganisms10010004

    Figure Lengend Snippet: Vaccine-induced humoral response quantified by anti-SARS-CoV-2 IgG titers in kidney transplant recipients and healthy individuals. ( A ) Vaccine-induced anti-SARS-CoV-2 IgG titers in kidney transplant recipients are impaired compared to healthy individuals. ( B ) Vaccine-induced anti-SARS-CoV-2 IgG titers are significantly elevated in kidney transplant recipients with immunosuppression lacking mycophenolate mofetil/mycophenolic acid. Vaccines used: BNT162b2 (BioNTech/Pfizer Mainz, Germany/New York, NY, USA) in kidney transplant recipients, and mRNA-1273 (Moderna, CA, United States) in healthy individuals. A Kruskal–Wallis test across all groups was used to indicate differences with respect to healthy individuals. A Mann–Whitney U test was used to indicate differences between two groups (**** p

    Article Snippet: Anti-SARS-CoV-2 IgG targeting the spike (S) protein was detected by the semiquantitative Euroimmun anti-SARS-CoV-2 IgG ELISA using the Euroimmun Analyzer I (Euroimmun Diagnostik, Lübeck, Germany), and by the quantitative IDK® anti-SARS-CoV-2 IgG ELISA (Immundiagnostik AG, Bensheim, Germany) using the DYNEX DSX® (Dynex Technologies, Chantilly, VA, USA), both using the recombinant S1 antigen of the spike protein, or the chemiluminescent microparticle immunoassay by Abbott for the quantitative detection of anti-spike RBD (receptor binding domain) IgG (SARS-CoV-2 IgG II Quant) using the automated system Alinity i (Abbott, Abbott Park, IL, USA).

    Techniques: MANN-WHITNEY

    Linear regression and correlation analysis carried out between blood bacterial load and serum zonulin levels. Correlation has been assessed through Pearson’s ( r coefficient), Spearman’s (ρ), and Kendall’s (τ) analyses. Analyses were performed on the first (n = 43, panels A , B,C ) and the second (n = 42, panel D , E,F ) set of blood samples collected from older people. The second set of blood samples was collected approximately four months after the first draw from the same older volunteers. Panels A and D, tables showing correlation and regression indexes and p values. Panels B and E, linear regression plot; vertical dotted lines indicate the quartiles. Panels C and F, Tukey box plots showing levels of bacterial DNAema in blood samples grouped in quartiles based on zonulin level.

    Journal: Scientific Reports

    Article Title: Bacterial DNAemia is associated with serum zonulin levels in older subjects

    doi: 10.1038/s41598-021-90476-0

    Figure Lengend Snippet: Linear regression and correlation analysis carried out between blood bacterial load and serum zonulin levels. Correlation has been assessed through Pearson’s ( r coefficient), Spearman’s (ρ), and Kendall’s (τ) analyses. Analyses were performed on the first (n = 43, panels A , B,C ) and the second (n = 42, panel D , E,F ) set of blood samples collected from older people. The second set of blood samples was collected approximately four months after the first draw from the same older volunteers. Panels A and D, tables showing correlation and regression indexes and p values. Panels B and E, linear regression plot; vertical dotted lines indicate the quartiles. Panels C and F, Tukey box plots showing levels of bacterial DNAema in blood samples grouped in quartiles based on zonulin level.

    Article Snippet: Serum zonulin levels were quantified using IDK® Zonulin ELISA Kit (Immundiagnostik AG, Germany).

    Techniques:

    Mean zonulin ELISA values obtained by testing specific candidate target proteins and patients’ serum samples. This ELISA kit did not detect increasing concentrations (range 1-50 μg/ml) of complement, recombinant zonulin (pre-HP2), mature HP1 or mature HP2. Conversely, a strong signal was detected in sera of both celiac disease patients (CD) and healthy controls (non-CD, internal control AF with HP2-2), irrespective of their HP genotype. All samples are technical triplicates, kit controls are shown for comparison.

    Journal: bioRxiv

    Article Title: Widely used commercial ELISA does not detect preHP-2, but recognizes properdin as a potential second member of the zonulin family

    doi: 10.1101/157578

    Figure Lengend Snippet: Mean zonulin ELISA values obtained by testing specific candidate target proteins and patients’ serum samples. This ELISA kit did not detect increasing concentrations (range 1-50 μg/ml) of complement, recombinant zonulin (pre-HP2), mature HP1 or mature HP2. Conversely, a strong signal was detected in sera of both celiac disease patients (CD) and healthy controls (non-CD, internal control AF with HP2-2), irrespective of their HP genotype. All samples are technical triplicates, kit controls are shown for comparison.

    Article Snippet: To measure zonulin, we used the commercially available ELISA kit (Immundiagnostik, Bensheim, Germany).

    Techniques: Enzyme-linked Immunosorbent Assay, Recombinant

    A) Mean zonulin ELISA values according to glucose tolerance groups B) mean ELISA values according to BMI groups. **: p

    Journal: bioRxiv

    Article Title: Widely used commercial ELISA does not detect preHP-2, but recognizes properdin as a potential second member of the zonulin family

    doi: 10.1101/157578

    Figure Lengend Snippet: A) Mean zonulin ELISA values according to glucose tolerance groups B) mean ELISA values according to BMI groups. **: p

    Article Snippet: To measure zonulin, we used the commercially available ELISA kit (Immundiagnostik, Bensheim, Germany).

    Techniques: Enzyme-linked Immunosorbent Assay

    Distribution of zonulin ELISA values according to haptoglobin genotypes. Data is presented as boxplots with Turkey-Whiskers and outliers.

    Journal: bioRxiv

    Article Title: Widely used commercial ELISA does not detect preHP-2, but recognizes properdin as a potential second member of the zonulin family

    doi: 10.1101/157578

    Figure Lengend Snippet: Distribution of zonulin ELISA values according to haptoglobin genotypes. Data is presented as boxplots with Turkey-Whiskers and outliers.

    Article Snippet: To measure zonulin, we used the commercially available ELISA kit (Immundiagnostik, Bensheim, Germany).

    Techniques: Enzyme-linked Immunosorbent Assay