Review




Structured Review

Boston Scientific Corporation electrogram fragmentation
Electrogram Fragmentation, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrogram/electrogram+fragmentation/pmc12657636-90-17-3
Average 86 stars, based on 1 article reviews
electrogram fragmentation - by Bioz Stars, 2026-11
86/100 stars

Images

Related Articles

other:

Article Title: Longevity of Cardiovascular Implantable Electronic Devices.
Article Snippet: Cardiac implantable electronic device generator changes caused by battery depletion are a major source of morbidity and mortality.. Modern pacemakers and defibrillators last much longer than their predecessors because of improvements in microcircuitry, capacitors, and battery chemistry and architecture.. Device longevity is maximized through device selection; minimization of high-voltage shocks; avoiding prolonged radiofrequency telemetry; and avoiding unnecessary, energy-intensive features, such as continuous unfiltered electrogram storage.

Article Title: Association between frequent cardiac resynchronization therapy optimization and long-term clinical response: a post hoc analysis of the Clinical Evaluation on Advanced Resynchronization (CLEAR) pilot study
Article Snippet: The SmartDelayTM (Boston Scientific Corporation, and QuickOptTM) uses the timing of intracardiac electrograms (IEGM) intervals to calculate the optimal AVD, while SonRTM (Sorin Group, Saluggia, Italy) uses a hemodynamic sensor selecting the VVD that yields maximal contractility to determine the optimal AVD., To calculate the optimal AVD, the algorithms developed to date either use the timing of intracardiac electrograms (IEGM) intervals (SmartDelayTM, Boston Scientific Corporation, and QuickOptTM), or a hemodynamic sensor (SonRTM, Sorin Group, Saluggia, Italy)., However, to date, the benefit and clinical value of the optimization of CRT programming remains unclear.

Article Title: A case of inappropriate pacing due to intermittent His bundle capture and the post–atrial pacing ventricular blanking period of managed ventricular pacing
Article Snippet: A unipolar electrogram (EGM) was recorded from the lead tip and displayed on an electrophysiology recording system (Bard; Boston Scientific, Lowell, MA) and a Medtronic pacing system analyzer (model 2290).

Article Title: Fusion Pacing with Biventricular, Left Ventricular-only and Multipoint Pacing in Cardiac Resynchronisation Therapy: Latest Evidence and Strategies for Use
Article Snippet: The SMART-AV trial randomised 980 patients 1:1:1 to the SmartDelay electrogram AV optimisation algorithm (Boston Scientific) versus echocardiographic AV optimisation versus nominal AV interval programming (120 ms).

Article Title: The impact of previous VT substrate radiofrequency catheter ablation procedures for patients presenting with electrical storm.
Article Snippet: Electrogram recording and analysis was performed using the Boston Scientific Labsystem PRO EP Recording System v.2.7.0.16.

Activity Assay:

Article Title: Relationship Between Complex Signal Identification and Non‐Pulmonary Vein Foci
Article Snippet: .. The Rhythmia platform (Boston Scientific, Marlborough, MA) incorporates a dedicated algorithm—fractionated atrial activity mapping (FAAM)—that automatically detects electrogram fragmentation (Lumipoint module) [ ]. ..

Comparison:

Article Title: An Overview of Current Cardiac Resynchronization Therapy
Article Snippet: .. 46 The SmartDelay determined AV optimization: a comparison to other AV delay methods used in cardiac resynchronization therapy (SMART-AV) trial showed electrogram optimization algorithm (Boston Scientific). ..

Activation Assay:

Article Title: Left Atrial Roof-Dependent Atrial Tachycardia Mimicking a Posterior Focal Atrial Tachycardia.
Article Snippet: .. Activation mapping based on an automated electrogram annotation using Rhythmia (Boston Scientific, Marlborough, Massachusetts) revealed a centrifugal pattern with the earliest activation in the posterior LA and conduction block along the roof (Figures 1A and 1B, Online Video 1). ..

Blocking Assay:

Article Title: Left Atrial Roof-Dependent Atrial Tachycardia Mimicking a Posterior Focal Atrial Tachycardia.
Article Snippet: .. Activation mapping based on an automated electrogram annotation using Rhythmia (Boston Scientific, Marlborough, Massachusetts) revealed a centrifugal pattern with the earliest activation in the posterior LA and conduction block along the roof (Figures 1A and 1B, Online Video 1). ..



Similar Products

86
Biosense Webster complex fractionated atrial electrograms cfae module
Complex Fractionated Atrial Electrograms Cfae Module, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrogram/3d+mapping+system/us12543994-250-9-24
Average 86 stars, based on 1 article reviews
complex fractionated atrial electrograms cfae module - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Abbott Laboratories requirements catheter system catheters electrogram hd 56
Requirements Catheter System Catheters Electrogram Hd 56, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrogram/advisor+catheter+grid+hd+mapping/us12502134-374-2-9
Average 86 stars, based on 1 article reviews
requirements catheter system catheters electrogram hd 56 - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Boston Scientific Corporation electrogram fragmentation
Electrogram Fragmentation, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrogram/electrogram+fragmentation/pmc12657636-90-17-3
Average 86 stars, based on 1 article reviews
electrogram fragmentation - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Abbott Laboratories intracardiac electrograms
Representative example of an induced ExPVT from the LA septum during isoproterenol provocation test. ( A ) <t>Intracardiac</t> electrograms showing AF initiation by an ExPVT induced during provocation. The earliest activation (circle marked by a pointed arrow) is recorded by the circular mapping catheter positioned at the LA septum, consistent with panels D and E . ( B ) Fluoroscopic image (AP view) showing a left atriogram with pulmonary venogram and initial positioning of multielectrode diagnostic catheters. ( C ) Standardized catheter configuration (AP view) during provocation testing, including a quadripolar catheter in the SVC, a decapolar across the high RA and septum, and a duodecapolar along the CS and low RA. A PV mapping catheter, typically positioned at the LA posterior wall, varied in type depending on availability, operator preference, and patient characteristics. ( D ) Electroanatomical activation map identifying the earliest trigger point (white arrow) of the ExPVT from the LA septum. ( E ) Electroanatomical voltage map showing a low-voltage area at the LA septum compatible with the AF trigger site. Abbreviations: AF, atrial fibrillation; AP, anterior posterior; CS, coronary sinus; ExPVT, extra-pulmonary vein trigger; HRA, high right atrium; LA, left atrium; LRA, low right atrium; PV, pulmonary vein; RA, right atrium; SR, sinus rhythm; SVC, superior vena cava.
Intracardiac Electrograms, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrogram/electrograms+intracardiac/pmc12510313-92-0-27
Average 86 stars, based on 1 article reviews
intracardiac electrograms - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Siemens AG electrograms
Representative example of an induced ExPVT from the LA septum during isoproterenol provocation test. ( A ) <t>Intracardiac</t> electrograms showing AF initiation by an ExPVT induced during provocation. The earliest activation (circle marked by a pointed arrow) is recorded by the circular mapping catheter positioned at the LA septum, consistent with panels D and E . ( B ) Fluoroscopic image (AP view) showing a left atriogram with pulmonary venogram and initial positioning of multielectrode diagnostic catheters. ( C ) Standardized catheter configuration (AP view) during provocation testing, including a quadripolar catheter in the SVC, a decapolar across the high RA and septum, and a duodecapolar along the CS and low RA. A PV mapping catheter, typically positioned at the LA posterior wall, varied in type depending on availability, operator preference, and patient characteristics. ( D ) Electroanatomical activation map identifying the earliest trigger point (white arrow) of the ExPVT from the LA septum. ( E ) Electroanatomical voltage map showing a low-voltage area at the LA septum compatible with the AF trigger site. Abbreviations: AF, atrial fibrillation; AP, anterior posterior; CS, coronary sinus; ExPVT, extra-pulmonary vein trigger; HRA, high right atrium; LA, left atrium; LRA, low right atrium; PV, pulmonary vein; RA, right atrium; SR, sinus rhythm; SVC, superior vena cava.
Electrograms, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrogram/electrograms/pmc12076779-86-16-27
Average 90 stars, based on 1 article reviews
electrograms - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

86
Galectin Therapeutics atrial electrogram ckd chronic kidney disease cpap continuous positive airway pressure cvd cardiovascular disease erat early recurrence
Representative example of an induced ExPVT from the LA septum during isoproterenol provocation test. ( A ) <t>Intracardiac</t> electrograms showing AF initiation by an ExPVT induced during provocation. The earliest activation (circle marked by a pointed arrow) is recorded by the circular mapping catheter positioned at the LA septum, consistent with panels D and E . ( B ) Fluoroscopic image (AP view) showing a left atriogram with pulmonary venogram and initial positioning of multielectrode diagnostic catheters. ( C ) Standardized catheter configuration (AP view) during provocation testing, including a quadripolar catheter in the SVC, a decapolar across the high RA and septum, and a duodecapolar along the CS and low RA. A PV mapping catheter, typically positioned at the LA posterior wall, varied in type depending on availability, operator preference, and patient characteristics. ( D ) Electroanatomical activation map identifying the earliest trigger point (white arrow) of the ExPVT from the LA septum. ( E ) Electroanatomical voltage map showing a low-voltage area at the LA septum compatible with the AF trigger site. Abbreviations: AF, atrial fibrillation; AP, anterior posterior; CS, coronary sinus; ExPVT, extra-pulmonary vein trigger; HRA, high right atrium; LA, left atrium; LRA, low right atrium; PV, pulmonary vein; RA, right atrium; SR, sinus rhythm; SVC, superior vena cava.
Atrial Electrogram Ckd Chronic Kidney Disease Cpap Continuous Positive Airway Pressure Cvd Cardiovascular Disease Erat Early Recurrence, supplied by Galectin Therapeutics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrogram/10__3390_slash_hearts6020012-461-28-52
Average 86 stars, based on 1 article reviews
atrial electrogram ckd chronic kidney disease cpap continuous positive airway pressure cvd cardiovascular disease erat early recurrence - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Anter Corporation multipolar electrogram configuration
Representative example of an induced ExPVT from the LA septum during isoproterenol provocation test. ( A ) <t>Intracardiac</t> electrograms showing AF initiation by an ExPVT induced during provocation. The earliest activation (circle marked by a pointed arrow) is recorded by the circular mapping catheter positioned at the LA septum, consistent with panels D and E . ( B ) Fluoroscopic image (AP view) showing a left atriogram with pulmonary venogram and initial positioning of multielectrode diagnostic catheters. ( C ) Standardized catheter configuration (AP view) during provocation testing, including a quadripolar catheter in the SVC, a decapolar across the high RA and septum, and a duodecapolar along the CS and low RA. A PV mapping catheter, typically positioned at the LA posterior wall, varied in type depending on availability, operator preference, and patient characteristics. ( D ) Electroanatomical activation map identifying the earliest trigger point (white arrow) of the ExPVT from the LA septum. ( E ) Electroanatomical voltage map showing a low-voltage area at the LA septum compatible with the AF trigger site. Abbreviations: AF, atrial fibrillation; AP, anterior posterior; CS, coronary sinus; ExPVT, extra-pulmonary vein trigger; HRA, high right atrium; LA, left atrium; LRA, low right atrium; PV, pulmonary vein; RA, right atrium; SR, sinus rhythm; SVC, superior vena cava.
Multipolar Electrogram Configuration, supplied by Anter Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrogram/multipolar+electrogram+configuration/pmc11956854-343-7-0
Average 90 stars, based on 1 article reviews
multipolar electrogram configuration - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Anter Corporation bipolar and unipolar electrograms
Representative example of an induced ExPVT from the LA septum during isoproterenol provocation test. ( A ) <t>Intracardiac</t> electrograms showing AF initiation by an ExPVT induced during provocation. The earliest activation (circle marked by a pointed arrow) is recorded by the circular mapping catheter positioned at the LA septum, consistent with panels D and E . ( B ) Fluoroscopic image (AP view) showing a left atriogram with pulmonary venogram and initial positioning of multielectrode diagnostic catheters. ( C ) Standardized catheter configuration (AP view) during provocation testing, including a quadripolar catheter in the SVC, a decapolar across the high RA and septum, and a duodecapolar along the CS and low RA. A PV mapping catheter, typically positioned at the LA posterior wall, varied in type depending on availability, operator preference, and patient characteristics. ( D ) Electroanatomical activation map identifying the earliest trigger point (white arrow) of the ExPVT from the LA septum. ( E ) Electroanatomical voltage map showing a low-voltage area at the LA septum compatible with the AF trigger site. Abbreviations: AF, atrial fibrillation; AP, anterior posterior; CS, coronary sinus; ExPVT, extra-pulmonary vein trigger; HRA, high right atrium; LA, left atrium; LRA, low right atrium; PV, pulmonary vein; RA, right atrium; SR, sinus rhythm; SVC, superior vena cava.
Bipolar And Unipolar Electrograms, supplied by Anter Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrogram/bipolar+and+unipolar+electrograms/pm40065579-241-19-13
Average 90 stars, based on 1 article reviews
bipolar and unipolar electrograms - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Biosense Webster complex fractionated atrial electrograms (cfae) module of the carto® 3 3d mapping system
Representative example of an induced ExPVT from the LA septum during isoproterenol provocation test. ( A ) <t>Intracardiac</t> electrograms showing AF initiation by an ExPVT induced during provocation. The earliest activation (circle marked by a pointed arrow) is recorded by the circular mapping catheter positioned at the LA septum, consistent with panels D and E . ( B ) Fluoroscopic image (AP view) showing a left atriogram with pulmonary venogram and initial positioning of multielectrode diagnostic catheters. ( C ) Standardized catheter configuration (AP view) during provocation testing, including a quadripolar catheter in the SVC, a decapolar across the high RA and septum, and a duodecapolar along the CS and low RA. A PV mapping catheter, typically positioned at the LA posterior wall, varied in type depending on availability, operator preference, and patient characteristics. ( D ) Electroanatomical activation map identifying the earliest trigger point (white arrow) of the ExPVT from the LA septum. ( E ) Electroanatomical voltage map showing a low-voltage area at the LA septum compatible with the AF trigger site. Abbreviations: AF, atrial fibrillation; AP, anterior posterior; CS, coronary sinus; ExPVT, extra-pulmonary vein trigger; HRA, high right atrium; LA, left atrium; LRA, low right atrium; PV, pulmonary vein; RA, right atrium; SR, sinus rhythm; SVC, superior vena cava.
Complex Fractionated Atrial Electrograms (Cfae) Module Of The Carto® 3 3d Mapping System, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrogram/complex+fractionated+atrial+electrograms/us12165324-70-17-24
Average 90 stars, based on 1 article reviews
complex fractionated atrial electrograms (cfae) module of the carto® 3 3d mapping system - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

96
ADInstruments epicardial electrogram recordings
Representative example of an induced ExPVT from the LA septum during isoproterenol provocation test. ( A ) <t>Intracardiac</t> electrograms showing AF initiation by an ExPVT induced during provocation. The earliest activation (circle marked by a pointed arrow) is recorded by the circular mapping catheter positioned at the LA septum, consistent with panels D and E . ( B ) Fluoroscopic image (AP view) showing a left atriogram with pulmonary venogram and initial positioning of multielectrode diagnostic catheters. ( C ) Standardized catheter configuration (AP view) during provocation testing, including a quadripolar catheter in the SVC, a decapolar across the high RA and septum, and a duodecapolar along the CS and low RA. A PV mapping catheter, typically positioned at the LA posterior wall, varied in type depending on availability, operator preference, and patient characteristics. ( D ) Electroanatomical activation map identifying the earliest trigger point (white arrow) of the ExPVT from the LA septum. ( E ) Electroanatomical voltage map showing a low-voltage area at the LA septum compatible with the AF trigger site. Abbreviations: AF, atrial fibrillation; AP, anterior posterior; CS, coronary sinus; ExPVT, extra-pulmonary vein trigger; HRA, high right atrium; LA, left atrium; LRA, low right atrium; PV, pulmonary vein; RA, right atrium; SR, sinus rhythm; SVC, superior vena cava.
Epicardial Electrogram Recordings, supplied by ADInstruments, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/electrogram/ECG+Analysis/pm39129342-231-3-21
Average 96 stars, based on 1 article reviews
epicardial electrogram recordings - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

Image Search Results


Representative example of an induced ExPVT from the LA septum during isoproterenol provocation test. ( A ) Intracardiac electrograms showing AF initiation by an ExPVT induced during provocation. The earliest activation (circle marked by a pointed arrow) is recorded by the circular mapping catheter positioned at the LA septum, consistent with panels D and E . ( B ) Fluoroscopic image (AP view) showing a left atriogram with pulmonary venogram and initial positioning of multielectrode diagnostic catheters. ( C ) Standardized catheter configuration (AP view) during provocation testing, including a quadripolar catheter in the SVC, a decapolar across the high RA and septum, and a duodecapolar along the CS and low RA. A PV mapping catheter, typically positioned at the LA posterior wall, varied in type depending on availability, operator preference, and patient characteristics. ( D ) Electroanatomical activation map identifying the earliest trigger point (white arrow) of the ExPVT from the LA septum. ( E ) Electroanatomical voltage map showing a low-voltage area at the LA septum compatible with the AF trigger site. Abbreviations: AF, atrial fibrillation; AP, anterior posterior; CS, coronary sinus; ExPVT, extra-pulmonary vein trigger; HRA, high right atrium; LA, left atrium; LRA, low right atrium; PV, pulmonary vein; RA, right atrium; SR, sinus rhythm; SVC, superior vena cava.

Journal: Europace

Article Title: Mapping and ablation outcomes of extra-pulmonary vein triggers in atrial fibrillation: single-centre retrospective study with consistent provocation protocol

doi: 10.1093/europace/euaf225

Figure Lengend Snippet: Representative example of an induced ExPVT from the LA septum during isoproterenol provocation test. ( A ) Intracardiac electrograms showing AF initiation by an ExPVT induced during provocation. The earliest activation (circle marked by a pointed arrow) is recorded by the circular mapping catheter positioned at the LA septum, consistent with panels D and E . ( B ) Fluoroscopic image (AP view) showing a left atriogram with pulmonary venogram and initial positioning of multielectrode diagnostic catheters. ( C ) Standardized catheter configuration (AP view) during provocation testing, including a quadripolar catheter in the SVC, a decapolar across the high RA and septum, and a duodecapolar along the CS and low RA. A PV mapping catheter, typically positioned at the LA posterior wall, varied in type depending on availability, operator preference, and patient characteristics. ( D ) Electroanatomical activation map identifying the earliest trigger point (white arrow) of the ExPVT from the LA septum. ( E ) Electroanatomical voltage map showing a low-voltage area at the LA septum compatible with the AF trigger site. Abbreviations: AF, atrial fibrillation; AP, anterior posterior; CS, coronary sinus; ExPVT, extra-pulmonary vein trigger; HRA, high right atrium; LA, left atrium; LRA, low right atrium; PV, pulmonary vein; RA, right atrium; SR, sinus rhythm; SVC, superior vena cava.

Article Snippet: Intracardiac electrograms were recorded using the Prucka CardioLabTM Electrophysiology system (General Electric Medical Systems, Inc., Milwaukee, WI, USA), and 3D electro-anatomical maps were created with the NavX (Abbott, Inc., Chicago, IL, USA) or CARTO (Biosense Webster, Diamond Bar, CA, USA) systems, using a PV-mapping catheter (Reflexion Spiral, AdvisorTM FL Circular, or HD Grid from Abbott, Inc.; AFocus, Lasso, PentaRay, or OctaRay from Biosense Webster, Inc.) through a long sheath.

Techniques: Activation Assay, Diagnostic Assay