Structured Review

Becton Dickinson edta vacutainer tubes
Kinetic analysis of circulating lymphocytes following influenza virus infection. Three ferrets each were inoculated i.n. with 10 6 PFU of virus. Blood was collected on days 3 (A), 7 (B), and 14 to 16 (C) p.i. in <t>EDTA</t> <t>Vacutainer</t> tubes and analyzed with
Edta Vacutainer Tubes, supplied by Becton Dickinson, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/edta vacutainer tubes/product/Becton Dickinson
Average 86 stars, based on 1 article reviews
Price from $9.99 to $1999.99
edta vacutainer tubes - by Bioz Stars, 2021-05
86/100 stars

Images

1) Product Images from "Pathogenesis and Transmission of Triple-Reassortant Swine H1N1 Influenza Viruses Isolated before the 2009 H1N1 Pandemic ▿"

Article Title: Pathogenesis and Transmission of Triple-Reassortant Swine H1N1 Influenza Viruses Isolated before the 2009 H1N1 Pandemic ▿

Journal: Journal of Virology

doi: 10.1128/JVI.02231-10

Kinetic analysis of circulating lymphocytes following influenza virus infection. Three ferrets each were inoculated i.n. with 10 6 PFU of virus. Blood was collected on days 3 (A), 7 (B), and 14 to 16 (C) p.i. in EDTA Vacutainer tubes and analyzed with
Figure Legend Snippet: Kinetic analysis of circulating lymphocytes following influenza virus infection. Three ferrets each were inoculated i.n. with 10 6 PFU of virus. Blood was collected on days 3 (A), 7 (B), and 14 to 16 (C) p.i. in EDTA Vacutainer tubes and analyzed with

Techniques Used: Infection

2) Product Images from "PB1-F2 Expression by the 2009 Pandemic H1N1 Influenza Virus Has Minimal Impact on Virulence in Animal Models ▿"

Article Title: PB1-F2 Expression by the 2009 Pandemic H1N1 Influenza Virus Has Minimal Impact on Virulence in Animal Models ▿

Journal: Journal of Virology

doi: 10.1128/JVI.02717-09

Analysis of circulating lymphocytes following influenza virus infection. For each virus, three to five ferrets were inoculated i.n. with 1 × 10 6 PFU. Blood was collected on days 3 (A), 7 (B), and 19 (C) p.i. into EDTA Vacutainer tubes and was
Figure Legend Snippet: Analysis of circulating lymphocytes following influenza virus infection. For each virus, three to five ferrets were inoculated i.n. with 1 × 10 6 PFU. Blood was collected on days 3 (A), 7 (B), and 19 (C) p.i. into EDTA Vacutainer tubes and was

Techniques Used: Infection

Related Articles

other:

Article Title: Maternal immunity enhances Mycoplasma hyopneumoniae vaccination induced cell-mediated immune responses in piglets
Article Snippet: Blood was collected via jugular venipuncture into sterile EDTA Vacutainer® tubes.

Article Title: DRD4 and DAT1 VNTR Genotyping in Children with Attention Deficit Hyperactivity Disorder
Article Snippet: Venous blood samples were collected in BD Vacutainer® EDTA tubes.

Article Title: Immunometabolic Responses after Short and Moderate Rest Intervals to Strength Exercise with and without Similar Total Volume
Article Snippet: BD Vacutainer® Fluoreto/EDTA tubes were used to measure glucose and lactate; Gel BD SST® II Advance® tubes were used for serum separation; and BD Vacutainer® EDTA K2 (Becton Dickinson, BD, Juiz de Fora, MG, Brazil) tubes were used for plasma separation.

Article Title: New insights into the effects of onion consumption on lipid mediators using a diet-induced model of hypercholesterolemia
Article Snippet: Blood collection was carried out in BD Vacutainer® tubes containing EDTA as anticoagulant.

Centrifugation:

Article Title: Association between increased levels of amyloid-β oligomers in plasma and episodic memory loss in Alzheimer’s disease
Article Snippet: .. Venous blood was collected in 6-ml BD Vacutainer® EDTA tubes and 10-ml BD Vacutainer® heparin tubes, followed by centrifugation at 850×g for 30 min at room temperature (RT). ..

Article Title: Mutational Portrait of Lung Adenocarcinoma in Brazilian Patients: Past, Present, and Future of Molecular Profiling in the Clinic
Article Snippet: .. Briefly, peripheral blood (4 ml) was collected in BD Vacutainer®/Hemogard™ EDTA K2 Plus tubes or BD Vacutainer® PPT™ tubes (BD Biosciences, NJ, USA) and submitted to centrifugation at 1,600 g for 10 min. .. The plasma was transferred to new tubes and centrifuged again at 1,600 g for 10 min. DNA was extracted from the plasma using the MagMAX Cell-Free DNA Isolation Kit (Thermo Fisher Scientific, MA, USA), according to the manufacturer's instructions.

DNA Extraction:

Article Title: Methylation status and long‐fragment cell‐free DNA are prognostic biomarkers for gastric cancer
Article Snippet: .. Samples were transferred to BD Vacutainer EDTA tubes (Becton Dickinson) and processed within 2 h. Plasma was separated by centrifuging the blood at 3000g for 10 min at 4°C and then stored at −80°C until DNA extraction, as previously reported., , . cfDNA was extracted from 1 ml of plasma using the Maxwell® RSC cfDNA Plasma Kit (Promega) according to blood and fluid protocols recommended by the manufacturer. cfDNA concentrations were measured using the Qubit quantification assay (Thermo Fisher Scientific). .. 2.4 Quantitative polymerase chain reaction (qPCR) of repeat DNA sequencesqPCR was performed to detect LINE‐1 using primers that amplify > 97‐bp fragments (L‐97) and > 169‐bp fragments (L‐169).

Coagulation:

Article Title: Coagulation assays and plasma fibrinogen concentrations in real-world patients with atrial fibrillation treated with dabigatran
Article Snippet: .. At each time point, both plasma dabigatran concentrations (BD Vacutainer® K2 EDTA tubes) and clotting times (BD Vacutainer® citrate tubes) were measured. .. For each patient, a venous blood sample at one time point was collected to measure plasma creatinine concentrations (BD Vacutainer® lithium heparin tubes).

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 86
    Becton Dickinson k3 edta vacutainer tubes
    Workstation setup. a Liquid handling workstation. b Tube rack workstation setup. The P1 rack contains centrifuged PB (Peripheral Blood) in BD <t>vacutainer</t> <t>EDTA</t> tubes. The S1 rack holds 50 mL conical tubes containing density gradient media, DPBS, DPBS + 2% FBS and an empty tube for waste. P3 contains the 15 mL conical tubes where the DPBS-diluted blood will be stratified onto 3 mL of the previously dispensed density gradient media. After centrifugation, the 15 mL conical tubes containing the stratified PB will be relocated to rack P3, and PBMCs will be transferred and diluted in the 15 mL conical tubes located in rack P4 containing 5 mL of DPBS + 2% FBS solution. DiTi disposable tips; LiHa liquid handling arms
    K3 Edta Vacutainer Tubes, supplied by Becton Dickinson, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/k3 edta vacutainer tubes/product/Becton Dickinson
    Average 86 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    k3 edta vacutainer tubes - by Bioz Stars, 2021-05
    86/100 stars
      Buy from Supplier

    86
    Becton Dickinson vacutainer edta tubes
    Effect of storage on different blood collection tubes. Symbols: ●, Vacuette <t>EDTA;</t> ▿, Vacuette NAST; ▪, <t>Vacutainer</t> EDTA.
    Vacutainer Edta Tubes, supplied by Becton Dickinson, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/vacutainer edta tubes/product/Becton Dickinson
    Average 86 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    vacutainer edta tubes - by Bioz Stars, 2021-05
    86/100 stars
      Buy from Supplier

    86
    Becton Dickinson edta vacutainer tubes
    Kinetic analysis of circulating lymphocytes following influenza virus infection. Three ferrets each were inoculated i.n. with 10 6 PFU of virus. Blood was collected on days 3 (A), 7 (B), and 14 to 16 (C) p.i. in <t>EDTA</t> <t>Vacutainer</t> tubes and analyzed with
    Edta Vacutainer Tubes, supplied by Becton Dickinson, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/edta vacutainer tubes/product/Becton Dickinson
    Average 86 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    edta vacutainer tubes - by Bioz Stars, 2021-05
    86/100 stars
      Buy from Supplier

    86
    Becton Dickinson plasma dabigatran concentrations
    Correlation plots for 120 samples of international normalized ratio (INR; A), activated partial thromboplastin time (aPTT; B), thrombin time (TT; C) and Hemoclot® Thrombin Inhibitor (HTI; D) against plasma <t>dabigatran</t> concentrations. For TT, all
    Plasma Dabigatran Concentrations, supplied by Becton Dickinson, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/plasma dabigatran concentrations/product/Becton Dickinson
    Average 86 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    plasma dabigatran concentrations - by Bioz Stars, 2021-05
    86/100 stars
      Buy from Supplier

    Image Search Results


    Workstation setup. a Liquid handling workstation. b Tube rack workstation setup. The P1 rack contains centrifuged PB (Peripheral Blood) in BD vacutainer EDTA tubes. The S1 rack holds 50 mL conical tubes containing density gradient media, DPBS, DPBS + 2% FBS and an empty tube for waste. P3 contains the 15 mL conical tubes where the DPBS-diluted blood will be stratified onto 3 mL of the previously dispensed density gradient media. After centrifugation, the 15 mL conical tubes containing the stratified PB will be relocated to rack P3, and PBMCs will be transferred and diluted in the 15 mL conical tubes located in rack P4 containing 5 mL of DPBS + 2% FBS solution. DiTi disposable tips; LiHa liquid handling arms

    Journal: Journal of Translational Medicine

    Article Title: Purification of viable peripheral blood mononuclear cells for biobanking using a robotized liquid handling workstation

    doi: 10.1186/s12967-019-2125-7

    Figure Lengend Snippet: Workstation setup. a Liquid handling workstation. b Tube rack workstation setup. The P1 rack contains centrifuged PB (Peripheral Blood) in BD vacutainer EDTA tubes. The S1 rack holds 50 mL conical tubes containing density gradient media, DPBS, DPBS + 2% FBS and an empty tube for waste. P3 contains the 15 mL conical tubes where the DPBS-diluted blood will be stratified onto 3 mL of the previously dispensed density gradient media. After centrifugation, the 15 mL conical tubes containing the stratified PB will be relocated to rack P3, and PBMCs will be transferred and diluted in the 15 mL conical tubes located in rack P4 containing 5 mL of DPBS + 2% FBS solution. DiTi disposable tips; LiHa liquid handling arms

    Article Snippet: Samples processing All samples were collected in 3 mL K3-EDTA vacutainer tubes (Becton–Dickinson, Ref. 368860), mixed immediately after the collection by inverting 10 times, and shipped to the lab in less than 30 min.

    Techniques: Centrifugation

    Effect of storage on different blood collection tubes. Symbols: ●, Vacuette EDTA; ▿, Vacuette NAST; ▪, Vacutainer EDTA.

    Journal: Journal of Clinical Microbiology

    Article Title: Effects of Storage and Type of Blood Collection Tubes on Hepatitis C Virus Level in Whole Blood Samples

    doi: 10.1128/JCM.39.5.1788-1790.2001

    Figure Lengend Snippet: Effect of storage on different blood collection tubes. Symbols: ●, Vacuette EDTA; ▿, Vacuette NAST; ▪, Vacutainer EDTA.

    Article Snippet: In addition, whole blood was collected in the following types of collection tubes: 3.0-ml Vacuette EDTA tubes (greiner bio-one GmbH, Kremsmünster, Austria), 3.5-ml Vacuette nucleic acid stabilization tubes (NASTs) (greiner bio-one GmbH), which contain a liquid nucleic acid stabilizer, and 3.0-ml Vacutainer EDTA tubes (BD Vacutainer Systems).

    Techniques:

    Kinetic analysis of circulating lymphocytes following influenza virus infection. Three ferrets each were inoculated i.n. with 10 6 PFU of virus. Blood was collected on days 3 (A), 7 (B), and 14 to 16 (C) p.i. in EDTA Vacutainer tubes and analyzed with

    Journal: Journal of Virology

    Article Title: Pathogenesis and Transmission of Triple-Reassortant Swine H1N1 Influenza Viruses Isolated before the 2009 H1N1 Pandemic ▿

    doi: 10.1128/JVI.02231-10

    Figure Lengend Snippet: Kinetic analysis of circulating lymphocytes following influenza virus infection. Three ferrets each were inoculated i.n. with 10 6 PFU of virus. Blood was collected on days 3 (A), 7 (B), and 14 to 16 (C) p.i. in EDTA Vacutainer tubes and analyzed with

    Article Snippet: Complete blood counts were quantified from blood collected in EDTA Vacutainer tubes (BD, Franklin Lakes, NJ) using a Hemavet HV950FS instrument per the manufacturer's instructions (Drew Scientific, Inc., Oxford, CT).

    Techniques: Infection

    Correlation plots for 120 samples of international normalized ratio (INR; A), activated partial thromboplastin time (aPTT; B), thrombin time (TT; C) and Hemoclot® Thrombin Inhibitor (HTI; D) against plasma dabigatran concentrations. For TT, all

    Journal: British Journal of Clinical Pharmacology

    Article Title: Coagulation assays and plasma fibrinogen concentrations in real-world patients with atrial fibrillation treated with dabigatran

    doi: 10.1111/bcp.12366

    Figure Lengend Snippet: Correlation plots for 120 samples of international normalized ratio (INR; A), activated partial thromboplastin time (aPTT; B), thrombin time (TT; C) and Hemoclot® Thrombin Inhibitor (HTI; D) against plasma dabigatran concentrations. For TT, all

    Article Snippet: At each time point, both plasma dabigatran concentrations (BD Vacutainer® K2 EDTA tubes) and clotting times (BD Vacutainer® citrate tubes) were measured.

    Techniques:

    (A) Correlation plot of plasma fibrinogen concentrations against thrombin time (TT; for 120 samples, TT > 300 s have been set to 300 s). (B) Correlation plot of standardized residuals (from the linear regression of plasma dabigatran concentrations

    Journal: British Journal of Clinical Pharmacology

    Article Title: Coagulation assays and plasma fibrinogen concentrations in real-world patients with atrial fibrillation treated with dabigatran

    doi: 10.1111/bcp.12366

    Figure Lengend Snippet: (A) Correlation plot of plasma fibrinogen concentrations against thrombin time (TT; for 120 samples, TT > 300 s have been set to 300 s). (B) Correlation plot of standardized residuals (from the linear regression of plasma dabigatran concentrations

    Article Snippet: At each time point, both plasma dabigatran concentrations (BD Vacutainer® K2 EDTA tubes) and clotting times (BD Vacutainer® citrate tubes) were measured.

    Techniques: