Structured Review

Agilent technologies dna microarray scanner model g2565aa
Dna Microarray Scanner Model G2565aa, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/dna microarray scanner model g2565aa/product/Agilent technologies
Average 86 stars, based on 1 article reviews
Price from $9.99 to $1999.99
dna microarray scanner model g2565aa - by Bioz Stars, 2020-04
86/100 stars

Related Products / Commonly Used Together

cy3
microarray
ssc buffer
cy5 channels

Images

Related Articles

Amplification:

Article Title: Genome-Wide Expression of Azoospermia Testes Demonstrates a Specific Profile and Implicates ART3 in Genetic Susceptibility
Article Snippet: For fluorescent cRNA synthesis, high-quality total RNA (150 ng) was labeled with the Low RNA Input Fluorescent Linear Amplification Kit (Agilent Technologies) according to the manufacturer's instructions. .. After hybridization, the microarray was washed with SSC buffer, and then scanned in Cy3 and Cy5 channels with the Agilent DNA Microarray Scanner model G2565AA (Agilent Technologies).

Labeling:

Article Title: Genome-Wide Expression of Azoospermia Testes Demonstrates a Specific Profile and Implicates ART3 in Genetic Susceptibility
Article Snippet: Labeled cRNAs (0.75 μg each) from one patient and the common reference were combined and fragmented in a hybridization mixture with the In Situ Hybridization Kit Plus (Agilent Technologies). .. After hybridization, the microarray was washed with SSC buffer, and then scanned in Cy3 and Cy5 channels with the Agilent DNA Microarray Scanner model G2565AA (Agilent Technologies).

Microarray:

Article Title: Genome-Wide Expression of Azoospermia Testes Demonstrates a Specific Profile and Implicates ART3 in Genetic Susceptibility
Article Snippet: .. After hybridization, the microarray was washed with SSC buffer, and then scanned in Cy3 and Cy5 channels with the Agilent DNA Microarray Scanner model G2565AA (Agilent Technologies). .. Signal intensity per spot was generated from the scanned image with Feature Extraction Software ver7.5 (Agilent Technologies) in default setting.

Generated:

Article Title: Genome-Wide Expression of Azoospermia Testes Demonstrates a Specific Profile and Implicates ART3 in Genetic Susceptibility
Article Snippet: After hybridization, the microarray was washed with SSC buffer, and then scanned in Cy3 and Cy5 channels with the Agilent DNA Microarray Scanner model G2565AA (Agilent Technologies). .. Signal intensity per spot was generated from the scanned image with Feature Extraction Software ver7.5 (Agilent Technologies) in default setting.

Hybridization:

Article Title: Genome-Wide Expression of Azoospermia Testes Demonstrates a Specific Profile and Implicates ART3 in Genetic Susceptibility
Article Snippet: .. After hybridization, the microarray was washed with SSC buffer, and then scanned in Cy3 and Cy5 channels with the Agilent DNA Microarray Scanner model G2565AA (Agilent Technologies). .. Signal intensity per spot was generated from the scanned image with Feature Extraction Software ver7.5 (Agilent Technologies) in default setting.

In Situ Hybridization:

Article Title: Genome-Wide Expression of Azoospermia Testes Demonstrates a Specific Profile and Implicates ART3 in Genetic Susceptibility
Article Snippet: Labeled cRNAs (0.75 μg each) from one patient and the common reference were combined and fragmented in a hybridization mixture with the In Situ Hybridization Kit Plus (Agilent Technologies). .. After hybridization, the microarray was washed with SSC buffer, and then scanned in Cy3 and Cy5 channels with the Agilent DNA Microarray Scanner model G2565AA (Agilent Technologies).

Software:

Article Title: Genome-Wide Expression of Azoospermia Testes Demonstrates a Specific Profile and Implicates ART3 in Genetic Susceptibility
Article Snippet: After hybridization, the microarray was washed with SSC buffer, and then scanned in Cy3 and Cy5 channels with the Agilent DNA Microarray Scanner model G2565AA (Agilent Technologies). .. Signal intensity per spot was generated from the scanned image with Feature Extraction Software ver7.5 (Agilent Technologies) in default setting.

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99
    Agilent technologies dna microarray scanner
    Double-round T7 amplification results in reduced technical variation compared to LM-PCR. Histograms of averaged binding ratios of four hybridizations with double-T7 ( A ) or LM-PCR amplified samples ( B ) across all <t>DNA</t> <t>microarray</t> probes. ( C ) Overview plot of chromosome 7 showing locations of array probes (black) and genes (green). Graphs of binding ratios of input versus ChIP show the background and binding signals for double-round T7 amplification (double-T7) (top) and LM-PCR (bottom). ( D ) Enlargement of indicated regions in (C).
    Dna Microarray Scanner, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 99/100, based on 1478 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/dna microarray scanner/product/Agilent technologies
    Average 99 stars, based on 1478 article reviews
    Price from $9.99 to $1999.99
    dna microarray scanner - by Bioz Stars, 2020-04
    99/100 stars
      Buy from Supplier

    85
    Agilent technologies dual laser dna microarray scanner model g2565aa
    Scatter plot of differentially expressed genes and heat map representation of <t>microarray</t> data for proapoptotic and <t>DNA</t> repair of differentially expressed genes. A , scatter plot of differentially expressed genes from colon mucosa from FD β- pol
    Dual Laser Dna Microarray Scanner Model G2565aa, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 85/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/dual laser dna microarray scanner model g2565aa/product/Agilent technologies
    Average 85 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    dual laser dna microarray scanner model g2565aa - by Bioz Stars, 2020-04
    85/100 stars
      Buy from Supplier

    Image Search Results


    Double-round T7 amplification results in reduced technical variation compared to LM-PCR. Histograms of averaged binding ratios of four hybridizations with double-T7 ( A ) or LM-PCR amplified samples ( B ) across all DNA microarray probes. ( C ) Overview plot of chromosome 7 showing locations of array probes (black) and genes (green). Graphs of binding ratios of input versus ChIP show the background and binding signals for double-round T7 amplification (double-T7) (top) and LM-PCR (bottom). ( D ) Enlargement of indicated regions in (C).

    Journal: Nucleic Acids Research

    Article Title: Improved genome-wide localization by ChIP-chip using double-round T7 RNA polymerase-based amplification

    doi: 10.1093/nar/gkm1144

    Figure Lengend Snippet: Double-round T7 amplification results in reduced technical variation compared to LM-PCR. Histograms of averaged binding ratios of four hybridizations with double-T7 ( A ) or LM-PCR amplified samples ( B ) across all DNA microarray probes. ( C ) Overview plot of chromosome 7 showing locations of array probes (black) and genes (green). Graphs of binding ratios of input versus ChIP show the background and binding signals for double-round T7 amplification (double-T7) (top) and LM-PCR (bottom). ( D ) Enlargement of indicated regions in (C).

    Article Snippet: Slides were scanned in an Agilent DNA Microarray Scanner (Model G2565BA, Agilent Technologies) and spot quantification was carried out using Imagene 4.0 (Biodiscovery).

    Techniques: Amplification, Polymerase Chain Reaction, Binding Assay, Microarray, Chromatin Immunoprecipitation

    Genome-wide transcriptomic data comparing Halobacterium sp. NRC-1 grown (A) aerobically ( y axis) versus anaerobically with arginine ( x axis) or (B) anaerobically with TMAO ( y axis) versus arginine ( x axis). DNA microarray data (fluorescence units) were

    Journal: Journal of Bacteriology

    Article Title: Genome-Wide Responses of the Model Archaeon Halobacterium sp. Strain NRC-1 to Oxygen Limitation

    doi: 10.1128/JB.01153-12

    Figure Lengend Snippet: Genome-wide transcriptomic data comparing Halobacterium sp. NRC-1 grown (A) aerobically ( y axis) versus anaerobically with arginine ( x axis) or (B) anaerobically with TMAO ( y axis) versus arginine ( x axis). DNA microarray data (fluorescence units) were

    Article Snippet: The labeled cDNA targets were combined and hybridized in duplicate for 17 h at 65°C in the dark, washed, and scanned for the Cy3 and Cy5 fluorescent signals on an Agilent DNA microarray scanner (model G2565BA).

    Techniques: Genome Wide, Microarray, Fluorescence

    Scatter plot of differentially expressed genes and heat map representation of microarray data for proapoptotic and DNA repair of differentially expressed genes. A , scatter plot of differentially expressed genes from colon mucosa from FD β- pol

    Journal: The Journal of Biological Chemistry

    Article Title: Folate Deficiency Provides Protection against Colon Carcinogenesis in DNA Polymerase ? Haploinsufficient Mice *

    doi: 10.1074/jbc.M109.069807

    Figure Lengend Snippet: Scatter plot of differentially expressed genes and heat map representation of microarray data for proapoptotic and DNA repair of differentially expressed genes. A , scatter plot of differentially expressed genes from colon mucosa from FD β- pol

    Article Snippet: Microarrays were scanned using the Agilent dual laser DNA microarray scanner model G2565AA, with 10-μm resolution.

    Techniques: Microarray