Structured Review

Agilent technologies db 5 capillary column
Db 5 Capillary Column, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/db 5 capillary column/product/Agilent technologies
Average 86 stars, based on 1 article reviews
Price from $9.99 to $1999.99
db 5 capillary column - by Bioz Stars, 2021-03
86/100 stars

Images

Related Articles

Gas Chromatography-Mass Spectrometry:

Article Title: The effect of sterol structure upon clathrin-mediated and clathrin-independent endocytosis
Article Snippet: .. The samples were then analyzed by using a 30 m (0.25 µm) DB5-MS column on an Agilent 7890 GC-MS. ..

Article Title: Catalysis by framework zinc in silica-based molecular sieves by framework zinc in silica-based molecular sieves †Electronic supplementary information (ESI) available. See DOI: 10.1039/c5sc03889h
Article Snippet: Quantitative GC-FID analysis of MPVO and DA cycloaddition dehydration reactions was performed on an Agilent 7890B GC system equipped with a flame ionization detector and an Agilent HP-5 column. .. Qualitative GC-MS analysis of products was performed on an Agilent 5890 GC system with an Agilent 5970 mass spectrometer and an Agilent DB-5 column. ..

Article Title: Metabolite Profiling of the Gut Microbiome in Mice with Dietary Administration of Black Raspberries
Article Snippet: After sonication, the propyl formate derivatives were extracted using hexane and then transferred to an autosampler vial for injection. .. An Agilent 7820A GC-5977B MS system (Santa Clara, CA) coupled with an Agilent DB-5 column (30 m × 0.25 mm × 0.25 μm) was used for the GC/MS analysis. ..

Article Title: Identification and Quantification of Six-Ring C26H16Cata-Condensed Polycyclic Aromatic Hydrocarbons in a Complex Mixture of Polycyclic Aromatic Hydrocarbons from Coal Tar
Article Snippet: NPLC/UV-Vis was performed using a Varian 9012 Solvent Delivery System (Agilent, Santa Clara, CA) coupled to Jasco UV-1570 Intelligent UV/Vis Detector (Jasco, Easton, MD) using a Waters Spherisorb 5 μm NH2 10 × 250 mm semi-prep LC column (Waters, Milford, MA). .. GC/MS analyses were performed on an Agilent 6890N Network Gas Chromatograph coupled to Agilent 5973 Inert Mass Selective Detector (Agilent, Santa Clara, CA) using a Restek Rxi-PAH GC Column (Restek, Bellefonte, PA), 60 m length, 0.25 mm id, 0.10 μm film thickness, maximum programmable temperature 360 °C, and minimum bleed at 350 °C, and using an Agilent DB-5 GC Column (Agilent, Santa Clara, CA), 5% phenylmethylpolysiloxane stationary phase, 60 m length, 0.25 mm id, 0.25 μm film thickness, maximum programmable temperature 350 °C, and minimum bleed at 325 °C. .. For the NPLC fractionation, 1 mL of the original sample of SRM 1597a was concentrated by evaporation to 0.5 mL and solvent-exchanged from toluene (the original solvent in SRM 1597a) to the solvent mixture hexane/dichloromethane (90/10 vol/vol).

Article Title: Systems Genomics of Metabolic Phenotypes in Wild-Type Drosophila melanogaster
Article Snippet: .. Samples were run in daily sets in a randomized order into a Thermo Scientific DSQ II Series single quadrupole GC-MS with an electron impact source and an Agilent DB-5 column run in splitless mode with a 30-min temperature ramp. ..

Mass Spectrometry:

Article Title: Catalysis by framework zinc in silica-based molecular sieves by framework zinc in silica-based molecular sieves †Electronic supplementary information (ESI) available. See DOI: 10.1039/c5sc03889h
Article Snippet: Quantitative GC-FID analysis of MPVO and DA cycloaddition dehydration reactions was performed on an Agilent 7890B GC system equipped with a flame ionization detector and an Agilent HP-5 column. .. Qualitative GC-MS analysis of products was performed on an Agilent 5890 GC system with an Agilent 5970 mass spectrometer and an Agilent DB-5 column. ..

Injection:

Article Title: Non‐acidic activation of pain‐related Acid‐Sensing Ion Channel 3 by lipids
Article Snippet: .. Dry methylesters of fatty acids were resuspended in 100 μl of cyclohexane, and 2 μl of cyclohexane was injected for gas chromatography (GC) analysis on a DB5 column (Agilent Technologies, France). ..

Gas Chromatography:

Article Title: Non‐acidic activation of pain‐related Acid‐Sensing Ion Channel 3 by lipids
Article Snippet: .. Dry methylesters of fatty acids were resuspended in 100 μl of cyclohexane, and 2 μl of cyclohexane was injected for gas chromatography (GC) analysis on a DB5 column (Agilent Technologies, France). ..

Article Title: In vitro effect of seven essential oils on the reproduction of the cattle tick Rhipicephalus microplus
Article Snippet: .. Gas chromatography-flame ionization detector (GC-FID) of essential oils The gas chromatography (GC) analyses were carried out using an 6890N GC-FID system equipped with DB-5 capillary column (30 m × 0.25 mm; film thickness of 0.25 mm) (Agilent Technologies, Santa Clara, United States) connected to an FID detector. ..

Chromatography:

Article Title: In vitro effect of seven essential oils on the reproduction of the cattle tick Rhipicephalus microplus
Article Snippet: .. Gas chromatography-flame ionization detector (GC-FID) of essential oils The gas chromatography (GC) analyses were carried out using an 6890N GC-FID system equipped with DB-5 capillary column (30 m × 0.25 mm; film thickness of 0.25 mm) (Agilent Technologies, Santa Clara, United States) connected to an FID detector. ..

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 93
    Agilent technologies db 1701 capillary column
    GC/MS/MS chromatograms of PCBs 47, 51, and 68 on (i) Supelco SPB-Octyl capillary column (ii) Agilent Technologies DB-5 capillary column and (iii) Agilent Technologies <t>DB-1701</t> capillary column.
    Db 1701 Capillary Column, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/db 1701 capillary column/product/Agilent technologies
    Average 93 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    db 1701 capillary column - by Bioz Stars, 2021-03
    93/100 stars
      Buy from Supplier

    97
    Agilent technologies fused silica capillary column
    GC/MS/MS chromatograms of PCBs 47, 51, and 68 on (i) Supelco SPB-Octyl capillary column (ii) Agilent Technologies DB-5 capillary column and (iii) Agilent Technologies <t>DB-1701</t> capillary column.
    Fused Silica Capillary Column, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/fused silica capillary column/product/Agilent technologies
    Average 97 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    fused silica capillary column - by Bioz Stars, 2021-03
    97/100 stars
      Buy from Supplier

    Image Search Results


    GC/MS/MS chromatograms of PCBs 47, 51, and 68 on (i) Supelco SPB-Octyl capillary column (ii) Agilent Technologies DB-5 capillary column and (iii) Agilent Technologies DB-1701 capillary column.

    Journal: Environmental science & technology

    Article Title: Emissions of Tetrachlorobiphenyls (PCBs 47, 51 and 68) from Polymer Resin on Kitchen Cabinets as a Non-Aroclor Source to Residential Air

    doi: 10.1021/acs.est.8b00966

    Figure Lengend Snippet: GC/MS/MS chromatograms of PCBs 47, 51, and 68 on (i) Supelco SPB-Octyl capillary column (ii) Agilent Technologies DB-5 capillary column and (iii) Agilent Technologies DB-1701 capillary column.

    Article Snippet: In specific instances of unexpectedly high congener results, specifically PCBs 44/47/65, 51, and 68, peak identification was confirmed by running the individual PCB standards and the sample on both a DB-5 and DB-1701 capillary column (Agilent Technologies). shows the MRM results for five tetrachlorobiphenyls (PCBs 44, 47, 65, 51, and 68) on all three capillary columns.

    Techniques: Gas Chromatography-Mass Spectrometry, Mass Spectrometry