Structured Review

Agilent technologies chromatography chromatographic analyses
Chromatography Chromatographic Analyses, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/chromatography chromatographic analyses/product/Agilent technologies
Average 91 stars, based on 1 article reviews
Price from $9.99 to $1999.99
chromatography chromatographic analyses - by Bioz Stars, 2020-08
91/100 stars

Related Products / Commonly Used Together

photodiode array detector

Images

Related Articles

Chromatography:

Article Title: Betulinic acid is a PPARγ antagonist that improves glucose uptake, promotes osteogenesis and inhibits adipogenesis
Article Snippet: .. Chromatography Chromatographic analyses were carried out on a HP 1100 system equipped with a photodiode array detector (Agilent Technologies, Santa Clara, CA, USA); X-Bridge (Waters, MA, USA) C18 column (5 µm, 150 × 4.9 mm i.d.). ..

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 88
    Agilent technologies afs high performance liquid chromatography hplc analysis
    <t>HPLC-ELSD</t> chromatograms of standard saponins ( A ) and <t>AFS</t> ( B ). ( a ) Anhuienoside E. ( b ) Glycoside St-I4a. ( c ) 3- O - α - l -Rhamnopyranosyl (1 → 2)- β - d -glucopyranosyl oleanolic acid 28- O - β - d -glucopyranosyl (1 → 6)- β - d -glucopyranosyl ester. ( d ) Hemsgiganoside B. ( e ) Flaccidoside II. ( f ) Hederasaponin B.
    Afs High Performance Liquid Chromatography Hplc Analysis, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 88/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/afs high performance liquid chromatography hplc analysis/product/Agilent technologies
    Average 88 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    afs high performance liquid chromatography hplc analysis - by Bioz Stars, 2020-08
    88/100 stars
      Buy from Supplier

    91
    Agilent technologies pg b pcl gel permeation chromatography gpc analysis
    Characterization of polymeric micelles: a Fluorescent intensity ratio of pyrene as a function of PG- b <t>-PCL</t> concentrations. Hydrodynamic size distribution b and TEM image c of bMCs. Hydrodynamic size distribution d and TEM image e of bNEs
    Pg B Pcl Gel Permeation Chromatography Gpc Analysis, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/pg b pcl gel permeation chromatography gpc analysis/product/Agilent technologies
    Average 91 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    pg b pcl gel permeation chromatography gpc analysis - by Bioz Stars, 2020-08
    91/100 stars
      Buy from Supplier

    85
    Agilent technologies phase high performance liquid chromatography rp hplc hplc analyses
    Reversed phase-high performance liquid chromatography <t>(RP-HPLC)</t> profile of H3. Performed on an <t>Agilent</t> 1100 HPLC system fitted with a ZORBAX ® 300SB-C8, Agilent column (5 μm, 300 Å, 4.6 × 250 mm).
    Phase High Performance Liquid Chromatography Rp Hplc Hplc Analyses, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 85/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/phase high performance liquid chromatography rp hplc hplc analyses/product/Agilent technologies
    Average 85 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    phase high performance liquid chromatography rp hplc hplc analyses - by Bioz Stars, 2020-08
    85/100 stars
      Buy from Supplier

    91
    Agilent technologies liquid chromatography mass spectrometry lc ms astaxanthin analysis
    Growth of H. pluvialis after re-suspension of green stage culture in <t>astaxanthin</t> production inducting conditions. Mean cell count data ± S.D. ( n = 3). The red stage involved culturing at 20 °C, continuous light at 240 µmol photons m −2 ·s −1 .
    Liquid Chromatography Mass Spectrometry Lc Ms Astaxanthin Analysis, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/liquid chromatography mass spectrometry lc ms astaxanthin analysis/product/Agilent technologies
    Average 91 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    liquid chromatography mass spectrometry lc ms astaxanthin analysis - by Bioz Stars, 2020-08
    91/100 stars
      Buy from Supplier

    Image Search Results


    HPLC-ELSD chromatograms of standard saponins ( A ) and AFS ( B ). ( a ) Anhuienoside E. ( b ) Glycoside St-I4a. ( c ) 3- O - α - l -Rhamnopyranosyl (1 → 2)- β - d -glucopyranosyl oleanolic acid 28- O - β - d -glucopyranosyl (1 → 6)- β - d -glucopyranosyl ester. ( d ) Hemsgiganoside B. ( e ) Flaccidoside II. ( f ) Hederasaponin B.

    Journal: Chinese Medicine

    Article Title: Crude triterpenoid saponins from Anemone flaccida (Di Wu) exert anti-arthritic effects on type II collagen-induced arthritis in rats

    doi: 10.1186/s13020-015-0052-y

    Figure Lengend Snippet: HPLC-ELSD chromatograms of standard saponins ( A ) and AFS ( B ). ( a ) Anhuienoside E. ( b ) Glycoside St-I4a. ( c ) 3- O - α - l -Rhamnopyranosyl (1 → 2)- β - d -glucopyranosyl oleanolic acid 28- O - β - d -glucopyranosyl (1 → 6)- β - d -glucopyranosyl ester. ( d ) Hemsgiganoside B. ( e ) Flaccidoside II. ( f ) Hederasaponin B.

    Article Snippet: HPLC analysis of AFS High performance liquid chromatography (HPLC) analysis was performed using an Agilent 1260 system (Agilent Corp., USA) equipped with a quaternary pump, an auto plate-sampler, a thermostatically controlled column apartment, and an evaporative light scattering detector (ELSD; Alltech Corp., USA).

    Techniques: High Performance Liquid Chromatography

    Characterization of polymeric micelles: a Fluorescent intensity ratio of pyrene as a function of PG- b -PCL concentrations. Hydrodynamic size distribution b and TEM image c of bMCs. Hydrodynamic size distribution d and TEM image e of bNEs

    Journal: Biomaterials Research

    Article Title: Lipiodol nanoemulsions stabilized with polyglycerol-polycaprolactone block copolymers for theranostic applications

    doi: 10.1186/s40824-017-0108-4

    Figure Lengend Snippet: Characterization of polymeric micelles: a Fluorescent intensity ratio of pyrene as a function of PG- b -PCL concentrations. Hydrodynamic size distribution b and TEM image c of bMCs. Hydrodynamic size distribution d and TEM image e of bNEs

    Article Snippet: Characterization of PG-b- PCL Gel permeation chromatography (GPC) analysis was performed using Agilent high performance liquid chromatography (HPLC) 110 series (Agilent Technologies, Palo Alto, CA, USA).

    Techniques: Transmission Electron Microscopy

    Synthesis and characterization of PG- b -PCL: a Synthetic scheme of PG- b -PCL: (i) Synthesis of EEGE, (ii) Polymerization of PEEGE, (iii) Ring-opening polymerization of ɛ-caprolactone to PEEGE- b -PCL, and (iv) De-protection of PEEGE to synthesize PG- b -PCL; b 1 H NMR spectrum of PG 40 - b -PCL 80 with the corresponding functional peaks shown in the chemical structure of PG- b -PCL in ( a ); c DSC diagram of PG- b -PCL in the second heating scan

    Journal: Biomaterials Research

    Article Title: Lipiodol nanoemulsions stabilized with polyglycerol-polycaprolactone block copolymers for theranostic applications

    doi: 10.1186/s40824-017-0108-4

    Figure Lengend Snippet: Synthesis and characterization of PG- b -PCL: a Synthetic scheme of PG- b -PCL: (i) Synthesis of EEGE, (ii) Polymerization of PEEGE, (iii) Ring-opening polymerization of ɛ-caprolactone to PEEGE- b -PCL, and (iv) De-protection of PEEGE to synthesize PG- b -PCL; b 1 H NMR spectrum of PG 40 - b -PCL 80 with the corresponding functional peaks shown in the chemical structure of PG- b -PCL in ( a ); c DSC diagram of PG- b -PCL in the second heating scan

    Article Snippet: Characterization of PG-b- PCL Gel permeation chromatography (GPC) analysis was performed using Agilent high performance liquid chromatography (HPLC) 110 series (Agilent Technologies, Palo Alto, CA, USA).

    Techniques: Nuclear Magnetic Resonance, Functional Assay

    Reversed phase-high performance liquid chromatography (RP-HPLC) profile of H3. Performed on an Agilent 1100 HPLC system fitted with a ZORBAX ® 300SB-C8, Agilent column (5 μm, 300 Å, 4.6 × 250 mm).

    Journal: Marine Drugs

    Article Title: A New Antiproliferative and Antioxidant Peptide Isolated from Arca subcrenata

    doi: 10.3390/md11061800

    Figure Lengend Snippet: Reversed phase-high performance liquid chromatography (RP-HPLC) profile of H3. Performed on an Agilent 1100 HPLC system fitted with a ZORBAX ® 300SB-C8, Agilent column (5 μm, 300 Å, 4.6 × 250 mm).

    Article Snippet: Reversed Phase-High Performance Liquid Chromatography (RP-HPLC) HPLC analyses were performed on an Agilent 1100 HPLC system fitted with a ZORBAX® 300SB-C8, Agilent column (5 μm, 300 Å, 4.6 mm × 250 mm).

    Techniques: High Performance Liquid Chromatography

    Growth of H. pluvialis after re-suspension of green stage culture in astaxanthin production inducting conditions. Mean cell count data ± S.D. ( n = 3). The red stage involved culturing at 20 °C, continuous light at 240 µmol photons m −2 ·s −1 .

    Journal: Biology

    Article Title: Media Screening for Obtaining Haematococcus pluvialis Red Motile Macrozooids Rich in Astaxanthin and Fatty Acids

    doi: 10.3390/biology7010002

    Figure Lengend Snippet: Growth of H. pluvialis after re-suspension of green stage culture in astaxanthin production inducting conditions. Mean cell count data ± S.D. ( n = 3). The red stage involved culturing at 20 °C, continuous light at 240 µmol photons m −2 ·s −1 .

    Article Snippet: Astaxanthin Analysis by Liquid Chromatography-Mass Spectrometry (LC-MS) Astaxanthin analysis was conducted using a 6460 Triple Quad LC/MS (Agilent, Cheadle, UK) with an Agilent G4212B 1260 photodiode array detector (PDAD), G1316A 1260 TCC column oven and a G1329B 1260 auto-sampler.

    Techniques: Cell Counting