Structured Review

Chiral Technologies Europe chiralpak agp
Typical CD traces recorded during the enantioselective HPLC of OME, IMP-B and IMP-E. Columns: <t>Chiralpak</t> ID-3 (100 mm×4.6 mm, 3μm) (left side) and <t>AGP</t> (100 mm×4.0 mm, 5μm) (right side); detection: CD at 280 nm; flow rate: 1.0 (left side) and 0.6 (right side) mL/min; column temperature: 40 °C (left side) and 25 °C (right side).
Chiralpak Agp, supplied by Chiral Technologies Europe, used in various techniques. Bioz Stars score: 85/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/chiralpak agp/product/Chiral Technologies Europe
Average 85 stars, based on 1 article reviews
Price from $9.99 to $1999.99
chiralpak agp - by Bioz Stars, 2022-10
85/100 stars

Images

1) Product Images from "Comparison of reversed-phase enantioselective HPLC methods for determining the enantiomeric purity of (S)-omeprazole in the presence of its related substances"

Article Title: Comparison of reversed-phase enantioselective HPLC methods for determining the enantiomeric purity of (S)-omeprazole in the presence of its related substances

Journal: Journal of Pharmaceutical Analysis

doi: 10.1016/j.jpha.2015.11.001

Typical CD traces recorded during the enantioselective HPLC of OME, IMP-B and IMP-E. Columns: Chiralpak ID-3 (100 mm×4.6 mm, 3μm) (left side) and AGP (100 mm×4.0 mm, 5μm) (right side); detection: CD at 280 nm; flow rate: 1.0 (left side) and 0.6 (right side) mL/min; column temperature: 40 °C (left side) and 25 °C (right side).
Figure Legend Snippet: Typical CD traces recorded during the enantioselective HPLC of OME, IMP-B and IMP-E. Columns: Chiralpak ID-3 (100 mm×4.6 mm, 3μm) (left side) and AGP (100 mm×4.0 mm, 5μm) (right side); detection: CD at 280 nm; flow rate: 1.0 (left side) and 0.6 (right side) mL/min; column temperature: 40 °C (left side) and 25 °C (right side).

Techniques Used: High Performance Liquid Chromatography, Flow Cytometry

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90
    Chiral Technologies Europe chiralpak agp hplc columns
    The chromatograms of CQ (a) and HCQ (b) on <t>ChiralPak</t> HSA column using 0 % IPA in the mobile phase in isocratic mode.
    Chiralpak Agp Hplc Columns, supplied by Chiral Technologies Europe, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/chiralpak agp hplc columns/product/Chiral Technologies Europe
    Average 90 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    chiralpak agp hplc columns - by Bioz Stars, 2022-10
    90/100 stars
      Buy from Supplier

    85
    Chiral Technologies Europe chiralpak agp
    Typical CD traces recorded during the enantioselective HPLC of OME, IMP-B and IMP-E. Columns: <t>Chiralpak</t> ID-3 (100 mm×4.6 mm, 3μm) (left side) and <t>AGP</t> (100 mm×4.0 mm, 5μm) (right side); detection: CD at 280 nm; flow rate: 1.0 (left side) and 0.6 (right side) mL/min; column temperature: 40 °C (left side) and 25 °C (right side).
    Chiralpak Agp, supplied by Chiral Technologies Europe, used in various techniques. Bioz Stars score: 85/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/chiralpak agp/product/Chiral Technologies Europe
    Average 85 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    chiralpak agp - by Bioz Stars, 2022-10
    85/100 stars
      Buy from Supplier

    90
    Chiral Technologies Europe chiralpak agp 2 0 ×
    Typical CD traces recorded during the enantioselective HPLC of OME, IMP-B and IMP-E. Columns: <t>Chiralpak</t> ID-3 (100 mm×4.6 mm, 3μm) (left side) and <t>AGP</t> (100 mm×4.0 mm, 5μm) (right side); detection: CD at 280 nm; flow rate: 1.0 (left side) and 0.6 (right side) mL/min; column temperature: 40 °C (left side) and 25 °C (right side).
    Chiralpak Agp 2 0 ×, supplied by Chiral Technologies Europe, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/chiralpak agp 2 0 ×/product/Chiral Technologies Europe
    Average 90 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    chiralpak agp 2 0 × - by Bioz Stars, 2022-10
    90/100 stars
      Buy from Supplier

    Image Search Results


    The chromatograms of CQ (a) and HCQ (b) on ChiralPak HSA column using 0 % IPA in the mobile phase in isocratic mode.

    Journal: ADMET & DMPK

    Article Title: Biomimetic properties and estimated in vivo distribution of chloroquine and hydroxy-chloroquine enantiomers

    doi: 10.5599/admet.929

    Figure Lengend Snippet: The chromatograms of CQ (a) and HCQ (b) on ChiralPak HSA column using 0 % IPA in the mobile phase in isocratic mode.

    Article Snippet: The HSA and AGP binding can be measured using Chiralpak HSA and Chiralpak AGP HPLC columns (Chiral Technologies Europe, France).

    Techniques: Indirect Immunoperoxidase Assay

    The chromatogram of racemic Chloroquine (CQ) (a) and hydroxychloroquine (HCQ) (b) obtained using the shallower gradient method (“slow gradient”) with 0 to 15 % IPA over 4.0 min and then maintained at 15 % for 1 min before returning to 0 % IPA on a Chiralpak AGP column (50 x 3 mm) with a 1.2 ml/min flow rate. The enantiomers are identified based on ref [ 51 ] that reported CQ (R) and HCQ (S) as the stronger binders to AGP.

    Journal: ADMET & DMPK

    Article Title: Biomimetic properties and estimated in vivo distribution of chloroquine and hydroxy-chloroquine enantiomers

    doi: 10.5599/admet.929

    Figure Lengend Snippet: The chromatogram of racemic Chloroquine (CQ) (a) and hydroxychloroquine (HCQ) (b) obtained using the shallower gradient method (“slow gradient”) with 0 to 15 % IPA over 4.0 min and then maintained at 15 % for 1 min before returning to 0 % IPA on a Chiralpak AGP column (50 x 3 mm) with a 1.2 ml/min flow rate. The enantiomers are identified based on ref [ 51 ] that reported CQ (R) and HCQ (S) as the stronger binders to AGP.

    Article Snippet: The HSA and AGP binding can be measured using Chiralpak HSA and Chiralpak AGP HPLC columns (Chiral Technologies Europe, France).

    Techniques: Indirect Immunoperoxidase Assay

    The calibration line obtained on the Chiralpak HSA (a) and Chiralpak AGP (b) columns by plotting the logarithmic value of the obtained retention times and the log k values derived from the literature % binding data [ 30 , 31 ]

    Journal: ADMET & DMPK

    Article Title: Biomimetic properties and estimated in vivo distribution of chloroquine and hydroxy-chloroquine enantiomers

    doi: 10.5599/admet.929

    Figure Lengend Snippet: The calibration line obtained on the Chiralpak HSA (a) and Chiralpak AGP (b) columns by plotting the logarithmic value of the obtained retention times and the log k values derived from the literature % binding data [ 30 , 31 ]

    Article Snippet: The HSA and AGP binding can be measured using Chiralpak HSA and Chiralpak AGP HPLC columns (Chiral Technologies Europe, France).

    Techniques: Derivative Assay, Binding Assay

    Typical CD traces recorded during the enantioselective HPLC of OME, IMP-B and IMP-E. Columns: Chiralpak ID-3 (100 mm×4.6 mm, 3μm) (left side) and AGP (100 mm×4.0 mm, 5μm) (right side); detection: CD at 280 nm; flow rate: 1.0 (left side) and 0.6 (right side) mL/min; column temperature: 40 °C (left side) and 25 °C (right side).

    Journal: Journal of Pharmaceutical Analysis

    Article Title: Comparison of reversed-phase enantioselective HPLC methods for determining the enantiomeric purity of (S)-omeprazole in the presence of its related substances

    doi: 10.1016/j.jpha.2015.11.001

    Figure Lengend Snippet: Typical CD traces recorded during the enantioselective HPLC of OME, IMP-B and IMP-E. Columns: Chiralpak ID-3 (100 mm×4.6 mm, 3μm) (left side) and AGP (100 mm×4.0 mm, 5μm) (right side); detection: CD at 280 nm; flow rate: 1.0 (left side) and 0.6 (right side) mL/min; column temperature: 40 °C (left side) and 25 °C (right side).

    Article Snippet: HPLC enantioseparations were performed using stainless-steel Chiralpak ID-3 (100 mm×4.6 mm, 3 µm) and Chiralpak AGP (100 mm×4.0 mm, 5 µm) columns (Chiral Technologies Europe, Illkirch, France).

    Techniques: High Performance Liquid Chromatography, Flow Cytometry