Review





Similar Products

90
Biosense Webster radiofrequency balloon catheter (rfb) "heliostar
Radiofrequency Balloon Catheter (Rfb) "Heliostar, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/radiofrequency balloon catheter (rfb) "heliostar/product/Biosense Webster
Average 90 stars, based on 1 article reviews
radiofrequency balloon catheter (rfb) "heliostar - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
CMA Microdialysis brain catheter
Brain Catheter, supplied by CMA Microdialysis, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/brain catheter/product/CMA Microdialysis
Average 90 stars, based on 1 article reviews
brain catheter - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Emcision Inc habib eus-rfa catheter
Habib Eus Rfa Catheter, supplied by Emcision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/habib eus-rfa catheter/product/Emcision Inc
Average 90 stars, based on 1 article reviews
habib eus-rfa catheter - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Shockwave Medical Inc shockwave c2 ivl™ catheter
Shockwave C2 Ivl™ Catheter, supplied by Shockwave Medical Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/shockwave c2 ivl™ catheter/product/Shockwave Medical Inc
Average 90 stars, based on 1 article reviews
shockwave c2 ivl™ catheter - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation open-irrigated ablation catheters
Open Irrigated Ablation Catheters, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/open-irrigated ablation catheters/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
open-irrigated ablation catheters - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

86
B. Braun venous catheter
Venous Catheter, supplied by B. Braun, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/venous catheter/product/B. Braun
Average 86 stars, based on 1 article reviews
venous catheter - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Terumo Corp 6 fr balloon catheter
6 Fr Balloon Catheter, supplied by Terumo Corp, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/6 fr balloon catheter/product/Terumo Corp
Average 86 stars, based on 1 article reviews
6 fr balloon catheter - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Inari Medical Inc venacore thrombectomy catheter
Occluded femoral vein with venous drainage predominantly through a patent profunda femoris vein (A) . Balloon angioplasty across the diseased segment was successful in creating a channel however significant elasticity resulted in persistent severe stenosis (B and C) . Following passage of the <t>VenaCore</t> device and repeat angioplasty, good luminal gain was achieved (D) .
Venacore Thrombectomy Catheter, supplied by Inari Medical Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/venacore thrombectomy catheter/product/Inari Medical Inc
Average 86 stars, based on 1 article reviews
venacore thrombectomy catheter - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Inari Medical Inc dedicated thrombectomy catheter
Occluded femoral vein with venous drainage predominantly through a patent profunda femoris vein (A) . Balloon angioplasty across the diseased segment was successful in creating a channel however significant elasticity resulted in persistent severe stenosis (B and C) . Following passage of the <t>VenaCore</t> device and repeat angioplasty, good luminal gain was achieved (D) .
Dedicated Thrombectomy Catheter, supplied by Inari Medical Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/dedicated thrombectomy catheter/product/Inari Medical Inc
Average 86 stars, based on 1 article reviews
dedicated thrombectomy catheter - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Abbott Laboratories catheter angle
Occluded femoral vein with venous drainage predominantly through a patent profunda femoris vein (A) . Balloon angioplasty across the diseased segment was successful in creating a channel however significant elasticity resulted in persistent severe stenosis (B and C) . Following passage of the <t>VenaCore</t> device and repeat angioplasty, good luminal gain was achieved (D) .
Catheter Angle, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/catheter angle/product/Abbott Laboratories
Average 86 stars, based on 1 article reviews
catheter angle - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

Image Search Results


Occluded femoral vein with venous drainage predominantly through a patent profunda femoris vein (A) . Balloon angioplasty across the diseased segment was successful in creating a channel however significant elasticity resulted in persistent severe stenosis (B and C) . Following passage of the VenaCore device and repeat angioplasty, good luminal gain was achieved (D) .

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

Article Title: Percutaneous management of post-thrombotic syndrome: Early experience with a novel thrombectomy catheter designed to address chronic venous occlusions

doi: 10.1016/j.jvscit.2026.102250

Figure Lengend Snippet: Occluded femoral vein with venous drainage predominantly through a patent profunda femoris vein (A) . Balloon angioplasty across the diseased segment was successful in creating a channel however significant elasticity resulted in persistent severe stenosis (B and C) . Following passage of the VenaCore device and repeat angioplasty, good luminal gain was achieved (D) .

Article Snippet: The VenaCore thrombectomy catheter (Inari Medical, Irvine California) has been developed to address chronic venous occlusions without the need for stenting.

Techniques:

Short segment occlusion of the left femoral vein successfully crossed and angioplastied (A and B) . Postangioplasty imaging shows a persistent luminal irregularity with filling of venous collaterals (C) . Following use of the VenaCore catheter, marked improvement in luminal patency and reduction in collateral filling was achieved (D) .

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

Article Title: Percutaneous management of post-thrombotic syndrome: Early experience with a novel thrombectomy catheter designed to address chronic venous occlusions

doi: 10.1016/j.jvscit.2026.102250

Figure Lengend Snippet: Short segment occlusion of the left femoral vein successfully crossed and angioplastied (A and B) . Postangioplasty imaging shows a persistent luminal irregularity with filling of venous collaterals (C) . Following use of the VenaCore catheter, marked improvement in luminal patency and reduction in collateral filling was achieved (D) .

Article Snippet: The VenaCore thrombectomy catheter (Inari Medical, Irvine California) has been developed to address chronic venous occlusions without the need for stenting.

Techniques: Imaging

Following recanalization of the iliofemoral segment with balloon angioplasty, a channel was created through the diseased segment (A) . This was then treated using the VenaCore device and repeat angioplasty with marked improvement in luminal caliber of the diseased segment and reduction in cross pelvic collateral flow (B and C) .

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

Article Title: Percutaneous management of post-thrombotic syndrome: Early experience with a novel thrombectomy catheter designed to address chronic venous occlusions

doi: 10.1016/j.jvscit.2026.102250

Figure Lengend Snippet: Following recanalization of the iliofemoral segment with balloon angioplasty, a channel was created through the diseased segment (A) . This was then treated using the VenaCore device and repeat angioplasty with marked improvement in luminal caliber of the diseased segment and reduction in cross pelvic collateral flow (B and C) .

Article Snippet: The VenaCore thrombectomy catheter (Inari Medical, Irvine California) has been developed to address chronic venous occlusions without the need for stenting.

Techniques:

Occlusion of the femoral vein with collateral drainage via the profunda femoral vein (A) . After crossing of the lesion, balloon angioplasty was performed with creation of a channel however significant luminal irregularity was again noted (B and C) . Following passage of the VenaCore device, an immediate angiogram shows improved patency along the inferior and mid segments of the vein.

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

Article Title: Percutaneous management of post-thrombotic syndrome: Early experience with a novel thrombectomy catheter designed to address chronic venous occlusions

doi: 10.1016/j.jvscit.2026.102250

Figure Lengend Snippet: Occlusion of the femoral vein with collateral drainage via the profunda femoral vein (A) . After crossing of the lesion, balloon angioplasty was performed with creation of a channel however significant luminal irregularity was again noted (B and C) . Following passage of the VenaCore device, an immediate angiogram shows improved patency along the inferior and mid segments of the vein.

Article Snippet: The VenaCore thrombectomy catheter (Inari Medical, Irvine California) has been developed to address chronic venous occlusions without the need for stenting.

Techniques: