Structured Review

Dr Maisch HPLC c18
C18, supplied by Dr Maisch HPLC, used in various techniques. Bioz Stars score: 92/100, based on 9 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/c18/product/Dr Maisch HPLC
Average 92 stars, based on 9 article reviews
Price from $9.99 to $1999.99
c18 - by Bioz Stars, 2020-09
92/100 stars

Images

Related Articles

Flow Cytometry:

Article Title: Hyaluronan enhances wound repair and increases collagen III in aged dermal wounds
Article Snippet: .. A 75 μm × 30 cm capillary column self-packed with 3 μm C18 (Dr. Maisch GmbH, Ammerbuch-Entringen, Germany) was operated at a flow rate of 250 nL/min with a 2-hour gradient of 0–35% acetonitrile in 0.1% formic acid. .. The column effluent was analyzed using a Thermo TSQ Vantage triple quadrupole mass spectrometer with electrospray ionization (Thermo Scientific, San Jose, CA).

Article Title: Mycobacterium tuberculosis supports protein tyrosine phosphorylation
Article Snippet: .. Peptide separation was performed on C18 (ReproSil-Pur C18-AQ, 120 Å, 3 μm; Dr. Maisch GmbH, Germany) capillary columns packed in house using 0.1% formic acid in water (A) and 0.1% formic acid in acetonitrile (B) with a gradient from 3–25% (vol/vol) B in 90 min at a flow rate of 0.3 µL/min. .. Survey full-scan MS spectra were acquired in the mass range m / z 400–2,000 in the Orbitrap analyzer at a resolution of 60,000.

other:

Article Title: Brain Citrullination Patterns and T Cell Reactivity of Cerebrospinal Fluid-Derived CD4+ T Cells in Multiple Sclerosis
Article Snippet: Column material was ReproSil-Pur, C18, 120 Å, AQ, 1.9 μm (Dr. Maisch GmbH, Ammerbuch Germany) and column dimensions ID 0.075 mm/length 150 mm.

Article Title: Memory B Cells Activate Brain-Homing, Autoreactive CD4+ T Cells in Multiple Sclerosis
Article Snippet: Resulting peptides were dissolved in 3% acetonitrile and 0.1% formic acid before injecting into an Easy-nLC 1000 linked to an Orbitrap Fusion instrument (Thermo Fisher Scientific) on a gradient of 120 min. As column material ReproSil-Pur, C18, 120 Å, AQ, 1.9 μm (Dr. Maisch GmbH) with column dimensions ID 0.075mm/ length 150mm was used.

Article Title: Identification of Sulfenylated Cysteines in Arabidopsis thaliana Proteins Using a Disulfide-Linked Peptide Reporter
Article Snippet: The precolumn was connected to a 12-cm 150-μm-inner diameter microcapillary analytical column packed with C18 (1.9 μm, 120 Å; Dr. Maisch GmbH, Ammerbuch-Entringen, Germany) and equipped with a home-made electrospray emitter tip.

Article Title: Human disposition, metabolism and excretion of etamicastat, a reversible, peripherally selective dopamine β-hydroxylase inhibitor
Article Snippet: Separation was performed on a Reprosil-Pur 100 basic–C18 3.0 μm, 2.0 mm × 50 mm column (Dr Maisch HPLC GmbH, Ammerbuch, Germany) using water containing 5 m m ammonium acetate (solution A) and methanol containing 5 m m ammonium acetate (B), as the mobile phase.

Article Title: Proteomic profiling of human cancer pseudopodia for the identification of anti-metastatic drug candidates
Article Snippet: 360 μm) filled with C18 (particle size 3 μm, 100 Å) resin (Dr. Maisch GmbH, Ammerbuch-Entrigen, Germany).

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90
    Dr Maisch HPLC reprosil gold 120 c18 column
    ( A ) Semi-preparative radio- and UV-HPLC chromatograms of [ 18 F] ICF24027 (conditions: <t>Reprosil-Pur</t> <t>C18-AQ,</t> 250 mm × 10 mm, 62% ACN/20 mM NH 4 OAc aq. , 3.0 mL/min). ( B ) Analytical radio- and UV-HPLC chromatograms of the final product of [ 18 F] ICF24027 spiked with the nonradioactive reference ICF24027 (conditions: Reprosil-Pur C18-AQ, 250 mm × 4.6 mm, gradient with eluent mixture of ACN/20 mM NH 4 OAc aq., 1.0 mL/min).
    Reprosil Gold 120 C18 Column, supplied by Dr Maisch HPLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/reprosil gold 120 c18 column/product/Dr Maisch HPLC
    Average 90 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    reprosil gold 120 c18 column - by Bioz Stars, 2020-09
    90/100 stars
      Buy from Supplier

    88
    Dr Maisch HPLC reprosil pur c18 aq column
    Representative analytical HPLC chromatogram: ( A ) plasma and ( B ) brain samples at 30 min p.i of [ 18 F] BIT1 in a CD-1 mouse; ( C ) sample from incubation of BIT1 with mouse liver microsomes (MLM) in the presence of NADPH for 90 min at 37 °C (UV detection: 228 nm; axis of retention time was adjusted). Conditions: isocratic system, column: <t>Reprosil-Pur</t> <t>C18-AQ,</t> 250 × 4.6 mm; eluent: 42% MeCN in 20 mM NH 4 OAc aq. , flow: 1.0 mL/min.
    Reprosil Pur C18 Aq Column, supplied by Dr Maisch HPLC, used in various techniques. Bioz Stars score: 88/100, based on 16 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/reprosil pur c18 aq column/product/Dr Maisch HPLC
    Average 88 stars, based on 16 article reviews
    Price from $9.99 to $1999.99
    reprosil pur c18 aq column - by Bioz Stars, 2020-09
    88/100 stars
      Buy from Supplier

    91
    Dr Maisch HPLC c18 particles
    A streamlined platform for detection of low-abundant peptides. This figure summarizes the key components in our mass-spectrometry based platform. Human blood or tissue samples are purified using <t>C18</t> materials and subsequently proteins are separated using high-performance liquid chromatography. Different proteases are then added to the 96 wells to initiate protein digestion and formation of peptides. The samples are subsequently purified using C18 materials and subjected to liquid chromatography coupled to mass spectrometry (LC–MS/MS) followed by data analysis using MaxQuant.
    C18 Particles, supplied by Dr Maisch HPLC, used in various techniques. Bioz Stars score: 91/100, based on 19 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/c18 particles/product/Dr Maisch HPLC
    Average 91 stars, based on 19 article reviews
    Price from $9.99 to $1999.99
    c18 particles - by Bioz Stars, 2020-09
    91/100 stars
      Buy from Supplier

    Image Search Results


    ( A ) Semi-preparative radio- and UV-HPLC chromatograms of [ 18 F] ICF24027 (conditions: Reprosil-Pur C18-AQ, 250 mm × 10 mm, 62% ACN/20 mM NH 4 OAc aq. , 3.0 mL/min). ( B ) Analytical radio- and UV-HPLC chromatograms of the final product of [ 18 F] ICF24027 spiked with the nonradioactive reference ICF24027 (conditions: Reprosil-Pur C18-AQ, 250 mm × 4.6 mm, gradient with eluent mixture of ACN/20 mM NH 4 OAc aq., 1.0 mL/min).

    Journal: Pharmaceuticals

    Article Title: Development of a New Radiofluorinated Quinoline Analog for PET Imaging of Phosphodiesterase 5 (PDE5) in Brain

    doi: 10.3390/ph9020022

    Figure Lengend Snippet: ( A ) Semi-preparative radio- and UV-HPLC chromatograms of [ 18 F] ICF24027 (conditions: Reprosil-Pur C18-AQ, 250 mm × 10 mm, 62% ACN/20 mM NH 4 OAc aq. , 3.0 mL/min). ( B ) Analytical radio- and UV-HPLC chromatograms of the final product of [ 18 F] ICF24027 spiked with the nonradioactive reference ICF24027 (conditions: Reprosil-Pur C18-AQ, 250 mm × 4.6 mm, gradient with eluent mixture of ACN/20 mM NH 4 OAc aq., 1.0 mL/min).

    Article Snippet: A Reprosil-Gold 120 C18 column (250 mm × 10 mm; 10 μm; Dr. Maisch HPLC GmbH) with 62% ACN/20 mM NH4 OAcaq . (pH 6.8) as eluent at a flow of 3.0 mL/min were used.

    Techniques: High Performance Liquid Chromatography

    Representative radio chromatograms of a mouse brain sample of [ 18 F] ICF24027 30 min p.i. ( A ) Micellar chromatography (conditions: Reprosil-Pur C18-AQ, 250 mm × 4.6 mm, gradient: 3%–30%–3% 1-PrOH/100 mM SDS aq., 10 mM Na 2 HPO 4 aq.; flow: 0.75 mL/min); ( B ) Reversed phase chromatography (conditions: Reprosil-Pur C18-AQ, 250 mm × 4.6 mm, gradient: 10%–90%–10% ACN/20 mM NH 4 OAc aq.; flow 1.0 mL/min).

    Journal: Pharmaceuticals

    Article Title: Development of a New Radiofluorinated Quinoline Analog for PET Imaging of Phosphodiesterase 5 (PDE5) in Brain

    doi: 10.3390/ph9020022

    Figure Lengend Snippet: Representative radio chromatograms of a mouse brain sample of [ 18 F] ICF24027 30 min p.i. ( A ) Micellar chromatography (conditions: Reprosil-Pur C18-AQ, 250 mm × 4.6 mm, gradient: 3%–30%–3% 1-PrOH/100 mM SDS aq., 10 mM Na 2 HPO 4 aq.; flow: 0.75 mL/min); ( B ) Reversed phase chromatography (conditions: Reprosil-Pur C18-AQ, 250 mm × 4.6 mm, gradient: 10%–90%–10% ACN/20 mM NH 4 OAc aq.; flow 1.0 mL/min).

    Article Snippet: A Reprosil-Gold 120 C18 column (250 mm × 10 mm; 10 μm; Dr. Maisch HPLC GmbH) with 62% ACN/20 mM NH4 OAcaq . (pH 6.8) as eluent at a flow of 3.0 mL/min were used.

    Techniques: Chromatography, Flow Cytometry, Reversed-phase Chromatography

    Representative analytical HPLC chromatogram: ( A ) plasma and ( B ) brain samples at 30 min p.i of [ 18 F] BIT1 in a CD-1 mouse; ( C ) sample from incubation of BIT1 with mouse liver microsomes (MLM) in the presence of NADPH for 90 min at 37 °C (UV detection: 228 nm; axis of retention time was adjusted). Conditions: isocratic system, column: Reprosil-Pur C18-AQ, 250 × 4.6 mm; eluent: 42% MeCN in 20 mM NH 4 OAc aq. , flow: 1.0 mL/min.

    Journal: Molecules

    Article Title: Radiosynthesis and Biological Investigation of a Novel Fluorine-18 Labeled Benzoimidazotriazine-Based Radioligand for the Imaging of Phosphodiesterase 2A with Positron Emission Tomography

    doi: 10.3390/molecules24224149

    Figure Lengend Snippet: Representative analytical HPLC chromatogram: ( A ) plasma and ( B ) brain samples at 30 min p.i of [ 18 F] BIT1 in a CD-1 mouse; ( C ) sample from incubation of BIT1 with mouse liver microsomes (MLM) in the presence of NADPH for 90 min at 37 °C (UV detection: 228 nm; axis of retention time was adjusted). Conditions: isocratic system, column: Reprosil-Pur C18-AQ, 250 × 4.6 mm; eluent: 42% MeCN in 20 mM NH 4 OAc aq. , flow: 1.0 mL/min.

    Article Snippet: A Reprosil-Pur C18-AQ column (250 × 4.6 mm; 5 µm; Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany) with MeCN/20 mM NH4 OAcaq . (pH 6.8) as eluent mixture and a flow of 1.0 mL/min was used (gradient: eluent A 10% MeCN/20 mM NH4 OAcaq .

    Techniques: High Performance Liquid Chromatography, Incubation, Flow Cytometry

    ( A ) Semi-preparative radio- and UV-HPLC chromatograms of [ 18 F] BIT1 (conditions: Reprosil-Pur C18-AQ, 250 × 10 mm, 46% MeCN/20 mM NH 4 OAc aq ., 5.5 mL/min); ( B ) Analytical radio- and UV-HPLC chromatograms of the final product of [ 18 F] BIT1 spiked with the non-radioactive reference BIT1 (conditions: Reprosil-Pur C18-AQ, 250 × 4.6 mm, gradient system with eluent mixture of MeCN/20 mM NH 4 OAc aq ., 1.0 mL/min).

    Journal: Molecules

    Article Title: Radiosynthesis and Biological Investigation of a Novel Fluorine-18 Labeled Benzoimidazotriazine-Based Radioligand for the Imaging of Phosphodiesterase 2A with Positron Emission Tomography

    doi: 10.3390/molecules24224149

    Figure Lengend Snippet: ( A ) Semi-preparative radio- and UV-HPLC chromatograms of [ 18 F] BIT1 (conditions: Reprosil-Pur C18-AQ, 250 × 10 mm, 46% MeCN/20 mM NH 4 OAc aq ., 5.5 mL/min); ( B ) Analytical radio- and UV-HPLC chromatograms of the final product of [ 18 F] BIT1 spiked with the non-radioactive reference BIT1 (conditions: Reprosil-Pur C18-AQ, 250 × 4.6 mm, gradient system with eluent mixture of MeCN/20 mM NH 4 OAc aq ., 1.0 mL/min).

    Article Snippet: A Reprosil-Pur C18-AQ column (250 × 4.6 mm; 5 µm; Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany) with MeCN/20 mM NH4 OAcaq . (pH 6.8) as eluent mixture and a flow of 1.0 mL/min was used (gradient: eluent A 10% MeCN/20 mM NH4 OAcaq .

    Techniques: High Performance Liquid Chromatography

    Scheme of the synthesis module TRACERlab FX2 N for the radiosynthesis of [ 18 F] BIT1 . (1) Chromafix ® 30 PS-HCO 3 −, (2) K 2 CO 3 (1.8 mg in 400 μL water), (3) K 2.2.2. (11 mg, 29 µmol in 1.0 mL MeCN), (4) precursor (0.5 mg of 5 in 1.0 mL DMSO), (5) 1.0 mL H 2 O and 2.0 mL MeCN/H 2 O (1:1), (6) injection vial, (7) Reprosil-Pur C18-AQ column (46% MeCN/20mM NH 4 OAc aq ., flow 5.5 mL/min), (8) 35 mL water, (9) Sep-Pak ® C18 light, (10) 2.0 mL water, (11) 1.2 mL EtOH, (12) product vial.

    Journal: Molecules

    Article Title: Radiosynthesis and Biological Investigation of a Novel Fluorine-18 Labeled Benzoimidazotriazine-Based Radioligand for the Imaging of Phosphodiesterase 2A with Positron Emission Tomography

    doi: 10.3390/molecules24224149

    Figure Lengend Snippet: Scheme of the synthesis module TRACERlab FX2 N for the radiosynthesis of [ 18 F] BIT1 . (1) Chromafix ® 30 PS-HCO 3 −, (2) K 2 CO 3 (1.8 mg in 400 μL water), (3) K 2.2.2. (11 mg, 29 µmol in 1.0 mL MeCN), (4) precursor (0.5 mg of 5 in 1.0 mL DMSO), (5) 1.0 mL H 2 O and 2.0 mL MeCN/H 2 O (1:1), (6) injection vial, (7) Reprosil-Pur C18-AQ column (46% MeCN/20mM NH 4 OAc aq ., flow 5.5 mL/min), (8) 35 mL water, (9) Sep-Pak ® C18 light, (10) 2.0 mL water, (11) 1.2 mL EtOH, (12) product vial.

    Article Snippet: A Reprosil-Pur C18-AQ column (250 × 4.6 mm; 5 µm; Dr. Maisch HPLC GmbH, Ammerbuch-Entringen, Germany) with MeCN/20 mM NH4 OAcaq . (pH 6.8) as eluent mixture and a flow of 1.0 mL/min was used (gradient: eluent A 10% MeCN/20 mM NH4 OAcaq .

    Techniques: Injection, Flow Cytometry

    High-performance liquid chromatography. Isocratic semi-preparative RP-HPLC chromatograms (left) and the analytical HPLC chromatograms (right) of the radiotracers spiked with the respective reference compounds. (A) [ 18 F] 1 ( t R = 35.3 min), eluent: 58% MeCN/10 mM NH 4 OAc aq. on a Reprosil Gold C18, 10 μm, 150 × 4.6 mm; flow rate: 2.5 mL/min. (B) [ 18 F] 2 ( t R = 35.6 min), eluent: 60% MeCN/20 mM NH 4 OAc aq. on a Multospher 120 RP-18 AQ, 5 μm, 150 × 10 mm; flow rate: 2.0 mL/min. The precursors for radiolabelling ( 13 and 15 ) and compound 20 (see ‘Experimental’ section) were also identified by analytical HPLC on a Multospher 120 RP 18 AQ column, 5 μm, 250 × 4.6 mm; solvents: A: 10% MeCN/20 mM NH 4 OAc, B: 90% MeCN/20 mM NH 4 OAc. Gradient elution(A%): 0 to 10 min, 100%; 10 to 40 min, gradient from 100% to 0%; 40 to 45 min, 0%; 45 to 50 min, 100% at a flow rate of 1 mL/min.

    Journal: Organic and Medicinal Chemistry Letters

    Article Title: Radiofluorination and biological evaluation of N-aryl-oxadiazolyl-propionamides as potential radioligands for PET imaging of cannabinoid CB2 receptors

    doi: 10.1186/2191-2858-3-11

    Figure Lengend Snippet: High-performance liquid chromatography. Isocratic semi-preparative RP-HPLC chromatograms (left) and the analytical HPLC chromatograms (right) of the radiotracers spiked with the respective reference compounds. (A) [ 18 F] 1 ( t R = 35.3 min), eluent: 58% MeCN/10 mM NH 4 OAc aq. on a Reprosil Gold C18, 10 μm, 150 × 4.6 mm; flow rate: 2.5 mL/min. (B) [ 18 F] 2 ( t R = 35.6 min), eluent: 60% MeCN/20 mM NH 4 OAc aq. on a Multospher 120 RP-18 AQ, 5 μm, 150 × 10 mm; flow rate: 2.0 mL/min. The precursors for radiolabelling ( 13 and 15 ) and compound 20 (see ‘Experimental’ section) were also identified by analytical HPLC on a Multospher 120 RP 18 AQ column, 5 μm, 250 × 4.6 mm; solvents: A: 10% MeCN/20 mM NH 4 OAc, B: 90% MeCN/20 mM NH 4 OAc. Gradient elution(A%): 0 to 10 min, 100%; 10 to 40 min, gradient from 100% to 0%; 40 to 45 min, 0%; 45 to 50 min, 100% at a flow rate of 1 mL/min.

    Article Snippet: Determination of lipophilicity (logD) and stability The distribution coefficients of [18 F] 1 and [18 F] 2 were also calculated from RP-HPLC retention times in three different systems: (1) isocratic elution (60% MeCN/20 mM NH4 OAc at a flow rate of 1 mL/min) and (2) gradient elution (starting from 10% MeCN/20 mM NH4 OAc aq. for 10 min with a gradient to 90% MeCN/20 mM NH4 OAc aq. over 30 min at a flow rate of 1 mL/min) on a Reprosil-Pur C18-AQ column (5 μm, 250 × 4.6 mm, Dr. Maisch HPLC GmbH, Ammerbruch-Entringen, Germany), and (3) isocratic elution (52.5% MeCN/20 mM NH4 OAc at a flow rate of 1 mL/min) on a Prodigy 5 μm C8 (250 × 4 mm; Phenomenex Ltd, Aschaffenburg, Germany) using the reference compounds following the protocol according to the EU guideline 67/548/EWG [ ].

    Techniques: High Performance Liquid Chromatography, Flow Cytometry

    A streamlined platform for detection of low-abundant peptides. This figure summarizes the key components in our mass-spectrometry based platform. Human blood or tissue samples are purified using C18 materials and subsequently proteins are separated using high-performance liquid chromatography. Different proteases are then added to the 96 wells to initiate protein digestion and formation of peptides. The samples are subsequently purified using C18 materials and subjected to liquid chromatography coupled to mass spectrometry (LC–MS/MS) followed by data analysis using MaxQuant.

    Journal: EBioMedicine

    Article Title: Oxyntomodulin Identified as a Marker of Type 2 Diabetes and Gastric Bypass Surgery by Mass-spectrometry Based Profiling of Human Plasma

    doi: 10.1016/j.ebiom.2016.03.034

    Figure Lengend Snippet: A streamlined platform for detection of low-abundant peptides. This figure summarizes the key components in our mass-spectrometry based platform. Human blood or tissue samples are purified using C18 materials and subsequently proteins are separated using high-performance liquid chromatography. Different proteases are then added to the 96 wells to initiate protein digestion and formation of peptides. The samples are subsequently purified using C18 materials and subjected to liquid chromatography coupled to mass spectrometry (LC–MS/MS) followed by data analysis using MaxQuant.

    Article Snippet: Columns (75 μm inner diameter, 20 cm length) were in-house packed with 1.9 μm C18 particles (Dr. Maisch GmbH, Germany).

    Techniques: Mass Spectrometry, Purification, High Performance Liquid Chromatography, Liquid Chromatography, Liquid Chromatography with Mass Spectroscopy