Review




Structured Review

MathWorks Inc simscape
Electrical configuration of whole-cell and microchamber voltage clamp. A, Whole-cell clamp speed is limited by τ ≈ Rs * Cm. Stray capacitance (amplifier, pipette holder, and pipette) is typically modeled in a position that does not interfere with voltage-clamp speed, but can influence measured high-frequency currents if not compensated. B, The microchamber partitions the cell partway within the orifice of the macropipette. Stray Cs1 is as with whole-cell mode. The frequency response of voltage clamp also depends on Rs and Cm, since stray Cs2, if it contributes at all, is dominated by Cm. The configuration in the figure is for a cell midway in the microchamber, membrane Cm equally divided. At high frequencies, the input capacitance will be the series combination of Cm/2 and Cm/2, giving a value of Cm/4. Thus, τ ≈ Rs * Cm/4 provides a faster clamp than whole cell, but the configuration suffers from lack of DC voltage-clamp control across the membranes. With partitioning of the cell more or less within the chamber, the series combination of the nonequal partitioned cell Cm will provide an input Cm less than the smaller of the two partitioned capacitances, regardless of its location inside or outside the microchamber. Thus, clamp τ for both inserted and extruded membranes will have the same U-shaped speed function, being slowest at the half-inserted condition, as depicted. C, Displayed are two current traces (ta and tb) generated by a Matlab <t>Simscape</t> microchamber model using a voltage protocol similar to our DC off-set AC voltage protocol (Fig. 10B, inset). The red trace (also marked with a downward red triangle) is at zero offset, and the blue trace (also marked with an upward blue triangle) is at an offset of −65 mV. Black lines are single exponential fits. Under voltage clamp, the time course of capacitive currents mirrors the time course of the voltage delivered to the cell membrane, as shown in D and E. See text for more details.
Simscape, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 988 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simulink+implementation/Simscape/pmc06001036-137-7-5
Average 96 stars, based on 988 article reviews
simscape - by Bioz Stars, 2026-11
96/100 stars

Images

1) Product Images from "The Frequency Response of Outer Hair Cell Voltage-Dependent Motility Is Limited by Kinetics of Prestin"

Article Title: The Frequency Response of Outer Hair Cell Voltage-Dependent Motility Is Limited by Kinetics of Prestin

Journal: The Journal of Neuroscience

doi: 10.1523/JNEUROSCI.0425-18.2018

Electrical configuration of whole-cell and microchamber voltage clamp. A, Whole-cell clamp speed is limited by τ ≈ Rs * Cm. Stray capacitance (amplifier, pipette holder, and pipette) is typically modeled in a position that does not interfere with voltage-clamp speed, but can influence measured high-frequency currents if not compensated. B, The microchamber partitions the cell partway within the orifice of the macropipette. Stray Cs1 is as with whole-cell mode. The frequency response of voltage clamp also depends on Rs and Cm, since stray Cs2, if it contributes at all, is dominated by Cm. The configuration in the figure is for a cell midway in the microchamber, membrane Cm equally divided. At high frequencies, the input capacitance will be the series combination of Cm/2 and Cm/2, giving a value of Cm/4. Thus, τ ≈ Rs * Cm/4 provides a faster clamp than whole cell, but the configuration suffers from lack of DC voltage-clamp control across the membranes. With partitioning of the cell more or less within the chamber, the series combination of the nonequal partitioned cell Cm will provide an input Cm less than the smaller of the two partitioned capacitances, regardless of its location inside or outside the microchamber. Thus, clamp τ for both inserted and extruded membranes will have the same U-shaped speed function, being slowest at the half-inserted condition, as depicted. C, Displayed are two current traces (ta and tb) generated by a Matlab Simscape microchamber model using a voltage protocol similar to our DC off-set AC voltage protocol (Fig. 10B, inset). The red trace (also marked with a downward red triangle) is at zero offset, and the blue trace (also marked with an upward blue triangle) is at an offset of −65 mV. Black lines are single exponential fits. Under voltage clamp, the time course of capacitive currents mirrors the time course of the voltage delivered to the cell membrane, as shown in D and E. See text for more details.
Figure Legend Snippet: Electrical configuration of whole-cell and microchamber voltage clamp. A, Whole-cell clamp speed is limited by τ ≈ Rs * Cm. Stray capacitance (amplifier, pipette holder, and pipette) is typically modeled in a position that does not interfere with voltage-clamp speed, but can influence measured high-frequency currents if not compensated. B, The microchamber partitions the cell partway within the orifice of the macropipette. Stray Cs1 is as with whole-cell mode. The frequency response of voltage clamp also depends on Rs and Cm, since stray Cs2, if it contributes at all, is dominated by Cm. The configuration in the figure is for a cell midway in the microchamber, membrane Cm equally divided. At high frequencies, the input capacitance will be the series combination of Cm/2 and Cm/2, giving a value of Cm/4. Thus, τ ≈ Rs * Cm/4 provides a faster clamp than whole cell, but the configuration suffers from lack of DC voltage-clamp control across the membranes. With partitioning of the cell more or less within the chamber, the series combination of the nonequal partitioned cell Cm will provide an input Cm less than the smaller of the two partitioned capacitances, regardless of its location inside or outside the microchamber. Thus, clamp τ for both inserted and extruded membranes will have the same U-shaped speed function, being slowest at the half-inserted condition, as depicted. C, Displayed are two current traces (ta and tb) generated by a Matlab Simscape microchamber model using a voltage protocol similar to our DC off-set AC voltage protocol (Fig. 10B, inset). The red trace (also marked with a downward red triangle) is at zero offset, and the blue trace (also marked with an upward blue triangle) is at an offset of −65 mV. Black lines are single exponential fits. Under voltage clamp, the time course of capacitive currents mirrors the time course of the voltage delivered to the cell membrane, as shown in D and E. See text for more details.

Techniques Used: Transferring, Generated

Related Articles

other:

Article Title: A simulation-based dataset for anomaly detection in hydrogen blend transport networks
Article Snippet: The data acquisition files include: • 12 pressure sensors (PS1–PS12) • 4 mass flow sensors (MFS1–MFS4) • Local restrictions (G1–G6) and compressors (C1–C3), which are also used to generate controlled anomalies The hydrogen transport network was modeled in MATLAB Simscape, initially developed in R2024b using Simscape Fluids.

Article Title: A simulation-based dataset for anomaly detection in hydrogen blend transport networks
Article Snippet: MATLAB_SIMSCAPE_Simulation/ , Original MATLAB Simscape files.

Article Title: A simulation-based dataset for anomaly detection in hydrogen blend transport networks
Article Snippet: The hydrogen transport network was modeled in MATLAB/Simscape (R2025a) using components from the Simscape Gas Fluids library.

Article Title: A simulation-based dataset for anomaly detection in hydrogen blend transport networks
Article Snippet: The model files can also be opened in earlier compatible MATLAB/Simscape versions (e.g., R2024a/b) and can be exported in a backward-compatible format.

Article Title: Dual-Unit ECG Acquisition System Without Shared Ground: Design and Implementation.
Article Snippet: The manufacturer-provided SPICE subcircuit description was automatically converted into a custom Simscape component using the subcircuit2ssc MATLAB function.

Article Title: Enhanced terminal sliding mode control for gait exoskeleton device: experimental investigation and validation.
Article Snippet: Furthermore, the models are validated in MATLAB/Simulink and Simscape, and extended with dynamic interaction assessments to suggest the device’s potential to support standard gait patterns, thereby addressing the relative underdevelopment of pediatric exoskeletons20.

Generated:

Article Title: A simulation-based dataset for anomaly detection in hydrogen blend transport networks
Article Snippet: .. Data collection , Data were generated using a MATLAB Simscape model simulating a hydrogen pipeline segment. The dataset includes 12 distributed virtual pressure sensors and 4 mass flow rate sensors, capturing both normal operating conditions and anomalous scenarios such as leaks, compressor failures, and delayed component responses. The simulation reproduces both transient and steady-state dynamics typical of industrial hydrogen transport networks.. ..

Control:

Article Title: A data-driven reinforcement learning framework for optimal balance control and stabilization of a rotary inverted pendulum
Article Snippet: .. The practical significance of TD3 for RIP control was demonstrated by the agent, which was trained in MATLAB Simscape and verified using a hardware model. For the Rotary Inverted Pendulum, a two-degree-offreedom underactuated nonlinear system, an adaptive neural network-based robust control technique was presented in Zabihifar et al. (2020). ..



Similar Products

96
MathWorks Inc vehicle implementation
Vehicle Implementation, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simulink+implementation/Simulink+Real-Time/pm41796153-44-40-43
Average 96 stars, based on 1 article reviews
vehicle implementation - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

96
MathWorks Inc matlab simulink implementation
Matlab Simulink Implementation, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simulink+implementation/Simulink+Real-Time/pmc12722242-44-26-26
Average 96 stars, based on 1 article reviews
matlab simulink implementation - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

96
MathWorks Inc simulink implementation
Simulink Implementation, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simulink+implementation/Simulink+Real-Time/pm41315655-411-1-1
Average 96 stars, based on 1 article reviews
simulink implementation - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

96
MathWorks Inc real time control implementation platform
Real Time Control Implementation Platform, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simulink+implementation/Simulink+Real-Time/10__1007_slash_s42417___025___02191___z-258-10-9
Average 96 stars, based on 1 article reviews
real time control implementation platform - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

96
MathWorks Inc time implementation
Time Implementation, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simulink+implementation/Simulink+Real-Time/10__1016_slash_j__rineng__2025__104384-161-4-13
Average 96 stars, based on 1 article reviews
time implementation - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

90
MathWorks Inc third-order model implemented in matlab/simulink
Third Order Model Implemented In Matlab/Simulink, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/simulink+implementation/10__1016_slash_j__applthermaleng__2024__124193-53-24-28
Average 90 stars, based on 1 article reviews
third-order model implemented in matlab/simulink - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results