Review



1x sterile physiological solution phosphate buffered saline (pbs)  (Avantor)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Avantor 1x sterile physiological solution phosphate buffered saline (pbs)
    1x Sterile Physiological Solution Phosphate Buffered Saline (Pbs), supplied by Avantor, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/physiological+buffer+solution/na2hpo4/pm37391528-44-46-57
    Average 90 stars, based on 1 article reviews
    1x sterile physiological solution phosphate buffered saline (pbs) - by Bioz Stars, 2026-10
    90/100 stars

    Images

    Related Articles

    Preserving:

    Article Title: Large Quantities of Bacterial DNA and Protein in Common Dietary Protein Source Used in Microbiome Studies.
    Article Snippet: The protocol described by Knudsen et al., which is based on the QIAamp DNA stool mini kit (Qiagen), was used to extract DNA, with minor modifications [20]. .. To remove the preservation solution from the fecal samples, 5 mL of 1X Phosphate Buffered Saline solution (VWR) was added to samples to dilute the preservation solution, followed by centrifugation (17,000 × g, 5 min) to pellet solids and bacterial cells. .. Pellets were lysed by beadbeating (3.1 m/s for 3 cycles of 30 s with 1 min of cooling on ice in between each cycle) in 2 mL bead beating tubes (Lysing Matrix E, MP Biomedicals) using a Bead Ruptor Elite 24 (Omni International).

    Saline:

    Article Title: Large Quantities of Bacterial DNA and Protein in Common Dietary Protein Source Used in Microbiome Studies.
    Article Snippet: The protocol described by Knudsen et al., which is based on the QIAamp DNA stool mini kit (Qiagen), was used to extract DNA, with minor modifications [20]. .. To remove the preservation solution from the fecal samples, 5 mL of 1X Phosphate Buffered Saline solution (VWR) was added to samples to dilute the preservation solution, followed by centrifugation (17,000 × g, 5 min) to pellet solids and bacterial cells. .. Pellets were lysed by beadbeating (3.1 m/s for 3 cycles of 30 s with 1 min of cooling on ice in between each cycle) in 2 mL bead beating tubes (Lysing Matrix E, MP Biomedicals) using a Bead Ruptor Elite 24 (Omni International).

    Centrifugation:

    Article Title: Large Quantities of Bacterial DNA and Protein in Common Dietary Protein Source Used in Microbiome Studies.
    Article Snippet: The protocol described by Knudsen et al., which is based on the QIAamp DNA stool mini kit (Qiagen), was used to extract DNA, with minor modifications [20]. .. To remove the preservation solution from the fecal samples, 5 mL of 1X Phosphate Buffered Saline solution (VWR) was added to samples to dilute the preservation solution, followed by centrifugation (17,000 × g, 5 min) to pellet solids and bacterial cells. .. Pellets were lysed by beadbeating (3.1 m/s for 3 cycles of 30 s with 1 min of cooling on ice in between each cycle) in 2 mL bead beating tubes (Lysing Matrix E, MP Biomedicals) using a Bead Ruptor Elite 24 (Omni International).

    other:

    Article Title: A nanoluciferase complementation-based assay for monitoring β-arrestin2 recruitment to the dopamine D 3 receptor
    Article Snippet: After another 24 h of culture, DMEM was aspirated, and wells were washed twice with 100 μl/well of chilled (4 °C) phosphate-buffered saline (PBS; VWR part of Avantor) containing 0.5 % (w/v) bovine serum albumin (BSA; Sigma-Aldrich).

    Article Title: Switchable ion-induced (bio)degradation of a novel polylactic acid composite including microfibrillated cellulose and calcium alginate
    Article Snippet: Polylactic acid (PLA) is a bio-based and potentially biodegradable polymer.. However, the degradation of this polyester in the natural environment is rather poor.. An improvement in its biodegradation behavior is crucial for common and future applications of PLA.

    Article Title: Estimation of Dopamine D 1 Receptor Agonist Binding Kinetics Using Time-Resolved Functional Assays: Relation to Agonist-Induced Receptor Internalization by Investigational Antiparkinsonian Therapeutics.
    Article Snippet: After 1 h incubation with D1R agonists at 37 °C, wells were washed twice with 100 μL per well of chilled (4 °C) phosphate-buffered saline (PBS; VWR part of Avantor) containing 0.5% (w/v) bovine serum albumin (BSA; SigmaAldrich).

    Article Title: Optimizing gold electrode surface treatments for enhanced dopamine detection: a comparative study
    Article Snippet: Laccase (oxygen oxidoreductase, EC 1.10.3.2, from Trametes versicolor, ≥10 U mg− 1), dopamine hydrochloride (DA), ascorbic acid (AA), tyrosine (Tyr), L-Cysteine, gold nanoparticles (diameter 20 nm, stabilized suspension in citrate buffer), were purchased from Sigma-Aldrich Co (Merck company).

    Article Title: A nanoluciferase complementation-based assay for monitoring β-arrestin2 recruitment to the dopamine D 3 receptor.
    Article Snippet: Luciferase complementation assays have emerged as a simple means of monitoring receptor-effector interactions in living cells in a time-resolved manner.. Here, we describe a nanoluciferase complementation assay capable of reporting on β-arrestin2 recruitment to the human dopamine D3 receptor (D3R) upon its activation in intact HEK293T cells.. Using this assay in time-resolved experiments, we detect differences in arrestin response termination rates between the endogenous agonist dopamine and the synthetic D3R agonist FAUC-73.

    Article Title: Development and characterization of PLA nanocomposites reinforced with bio-ceramic particles for orthognathic implants: Enhanced mechanical and biological properties.
    Article Snippet: The clinical application of osteofixation materials is crucial for maxillofacial reconstruction and orthognathic surgeries.. To overcome the limitations of traditional metallic implants, bioabsorbable materials are gaining popularity due to their ability to avoid secondary removal surgeries and reduce stress shielding.. This study investigates third-generation biomaterials, focusing on polylactic acid (PLA) for its biocompatibility and biodegradability, and hydroxyapatite (HAP) for its bioactive osteoconductive and bioresorbable properties.

    Article Title: Chemical Composition and In Vitro Biological Activity of the Polar and Non-Polar Fractions Obtained from the Roots of Eleutherococcus senticosus (Rupr. et Maxim.) Maxim.
    Article Snippet: The following solvents, used for extraction, were sourced from Avantor Performance Materials (Gliwice, Poland): gradient-grade acetonitrile, trifluoroacetic acid (≥99%), phosphate-buffered saline (PBS), DMEM, and RPMI 1649 Medium, among others.



    Similar Products

    97
    Thermo Fisher physiologic buffer solution
    Physiologic Buffer Solution, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/physiological+buffer+solution/Buffer+solution+pH+7%2C+Phosphate+buffer/pmc13080204-38-34-51
    Average 97 stars, based on 1 article reviews
    physiologic buffer solution - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    86
    Merck & Co physiological buffer solution
    Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
    Physiological Buffer Solution, supplied by Merck & Co, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/physiological+buffer+solution/buffer+solution/pmc12538826-77-15-27
    Average 86 stars, based on 1 article reviews
    physiological buffer solution - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    90
    Beijing Solarbio Science physiological phosphate buffered saline (pbs) solution
    Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
    Physiological Phosphate Buffered Saline (Pbs) Solution, supplied by Beijing Solarbio Science, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/physiological+buffer+solution/phosphate+buffered+saline++pbs+/pm40623971-196-2-15
    Average 90 stars, based on 1 article reviews
    physiological phosphate buffered saline (pbs) solution - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Fisher Bioreagents physiological buffer solution fisher bioreagents bp661-50
    Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
    Physiological Buffer Solution Fisher Bioreagents Bp661 50, supplied by Fisher Bioreagents, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/physiological+buffer+solution/phosphate+buffered+saline/pm37549255-173-12-15
    Average 90 stars, based on 1 article reviews
    physiological buffer solution fisher bioreagents bp661-50 - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Avantor 1x sterile physiological solution phosphate buffered saline (pbs)
    Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
    1x Sterile Physiological Solution Phosphate Buffered Saline (Pbs), supplied by Avantor, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/physiological+buffer+solution/na2hpo4/pm37391528-44-46-57
    Average 90 stars, based on 1 article reviews
    1x sterile physiological solution phosphate buffered saline (pbs) - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Millipore physiological phosphate buffer solution (pbs)
    Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
    Physiological Phosphate Buffer Solution (Pbs), supplied by Millipore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/physiological+buffer+solution/physiological+phosphate+buffer+solution++pbs+/us11577008-1265-17-28
    Average 90 stars, based on 1 article reviews
    physiological phosphate buffer solution (pbs) - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Fisher Scientific bicarbonate-buffered physiological salt solution bbpss
    Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
    Bicarbonate Buffered Physiological Salt Solution Bbpss, supplied by Fisher Scientific, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/physiological+buffer+solution/physiological+salt+solution+pss/pmc09926536-53-7-22
    Average 90 stars, based on 1 article reviews
    bicarbonate-buffered physiological salt solution bbpss - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    99
    Thermo Fisher physiological buffered saline pbs solution
    Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
    Physiological Buffered Saline Pbs Solution, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/physiological+buffer+solution/PHOSPHATE+BUFFERED+SALINE+PBS/pmc09722481-95-0-6
    Average 99 stars, based on 1 article reviews
    physiological buffered saline pbs solution - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    90
    Thermo Fisher physiologic buffered solution a14291dj
    Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
    Physiologic Buffered Solution A14291dj, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/physiological+buffer+solution/live+cell+imaging+solution/10__1158_slash_2159___8290__cd___22___0535-280-9-11
    Average 90 stars, based on 1 article reviews
    physiologic buffered solution a14291dj - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Millipore a shield-on solution is a weak-base physiological buffer solution (ph∼9) to trigger epoxy-based-crosslinking of biomolecules
    Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of <t>physiological</t> buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD
    A Shield On Solution Is A Weak Base Physiological Buffer Solution (Ph∼9) To Trigger Epoxy Based Crosslinking Of Biomolecules, supplied by Millipore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/physiological+buffer+solution/a+shield+on+solution+is+a+weak+base+physiological+buffer+solution++ph+9++to+trigger+epoxy+based+crosslinking+of+biomolecules/bio_rxiv__2022__03__13__484171-339-14-24
    Average 90 stars, based on 1 article reviews
    a shield-on solution is a weak-base physiological buffer solution (ph∼9) to trigger epoxy-based-crosslinking of biomolecules - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results


    Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of physiological buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD

    Journal: Cardio-oncology

    Article Title: Radiation- and age-related vascular dysfunction as an early indicator of cardiovascular risk: a long-term study in the ApoE −/− mouse model of atherosclerosis

    doi: 10.1186/s40959-025-00395-6

    Figure Lengend Snippet: Experimental set-up for irradiation and OCT-imaging of the murine Arteria saphena. A For irradiation in the X-ray device (1), anesthetized animals were positioned on their left side and secured on a Plexiglas holder. The bent right leg and lower abdomen were shielded with lead to protect them from radiation, ensuring that only the inner side of the left lower leg remained within the irradiation field. The exposure area beneath the irradiation window was defined by a collimator plate made of a bismuth-lead-tin alloy (MCP-96) with copper cutouts (2). Up to five animals were irradiated simultaneously on an underlying Plexiglas plate (3). The mesures are given in centimeters. B The OCT system for vascular imaging of the A. saphena operates using near-infrared light emitted by a diode (1), which is transmitted to the scanner head (2) via fiber optic cables (3). Within the scanner head the incoming light is collimated to a beam of 2.4 mm in diameter through a collimator (4) (focal length = 12 mm) and subsequently divided into a reference and probe beam of equal diameter with a beam splitter. To scan the arterial surface, the probe beam is diffracted via two galvanometric scanners (5) (Cambridge Technologies, Planegg) and focused through an achromatic lense (6) (focal length = 25.4 mm, diameter = 15 mm). The light reflected by the arterial surface and the reference beam that has been reflected by a mirror are then recombined by the beam splitter. Fiber optic cables lead the resulting interference signal through a collimator (focal length = 40 mm) and to a spectrometer to be spectrally analyzed with a diffraction grating (1200 lines/mm). The interference spectrum is then focused through an achromatic lense (focal length = 75 mm) and detected with a silicon detector (LIS-1024, pixel size: 7.8 μm × 125 μm × 1024 px, Photon Vision Systems Inc., Homer, USA). A Fast Fourier Transform of the interference signal provides depth-resolved information about the arterial tissue. C Representative recording of the A. saphena (white arrows) and Vena saphena medialis (grey arrows) of a C57BL/6 mouse aged 8 weeks, one day after irradiation with 2 Gy. The upper picture row in the foreground represents 2-D cross sectional OCT-images. The picture row below in the background are video-recordings to orientate on the tissue. Left: Vessel diameter at rest after application of physiological buffer solution. Middle: Arterial vasoconstriction (VC) after application of buffer solution with high potassium concentration (K+). Right: Arterial vasodilation (VD) induced by sodium nitroprusside (SNP). The diameter of the saphenous vein was unaffected. Below: Time course of inner diameter changes of A. saphena with fitted sigmoid function (black line). d0: initial diameter, dVC: minimal diameter during VC. dVD: maximal diameter during VD. t 1/2 : time of half VC or VD

    Article Snippet: To assess the arterial diameter at baseline the exposed A. saphena was moistened with a physiological buffer solution (NaCl: 119 mmol/l, Merck, Darmstadt, Germany; KCl: 4.7 mmol/l, Merck; MgSO 4 : 1.17 mmol/l, Sigma-Aldrich, Taufkirchen, Germany; NaHCO 3 : 25 mmol/l, Merck; KH 2 PO 4 : 1.18 mmol/l, Merck; Glucose: 5.5 mmol/l, Merck; EDTA: 0.027 mmol/l, Prolabo, VWR International, Darmstadt) right before starting OCT. Acquisition of the baseline diameter stopped automatically after 30 initial B-scans (equivalent to a recording time of 7.5 s).

    Techniques: Irradiation, Imaging, Concentration Assay