Review




Structured Review

Sensovation ag microplate reader clair
Overview of the design, fabrication and use of the AgroDiag porcine enteric coronavirus (PEC) multiplex planar immunoassay. (A) Manufacturing steps include functionalization of the wells of a <t>microplate</t> with a dextran layer before printing of the protein array in triplicate. (B) The assay protocol and working principle is similar to the solid-phase standard indirect ELISA. After the three typical incubation steps (serum sample, conjugate, and substrate), followed by microplate reading. The reaction was visualized as brown spots which intensity correlated with antibody levels to specific viral antigen target in the array. Four results are obtainable depending on incubation with a negative control, or samples from PDCoV, PEDV, TGEV inoculation groups. Scale bar corresponds to 1 mm. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
Microplate Reader Clair, supplied by Sensovation ag, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+readers/fluorescence+microarray+reader/pmc07298477-72-15-18
Average 90 stars, based on 1 article reviews
microplate reader clair - by Bioz Stars, 2026-09
90/100 stars

Images

1) Product Images from "Agrodiag PorCoV: A multiplex immunoassay for the differential diagnosis of porcine enteric coronaviruses"

Article Title: Agrodiag PorCoV: A multiplex immunoassay for the differential diagnosis of porcine enteric coronaviruses

Journal: Journal of Immunological Methods

doi: 10.1016/j.jim.2020.112808

Overview of the design, fabrication and use of the AgroDiag porcine enteric coronavirus (PEC) multiplex planar immunoassay. (A) Manufacturing steps include functionalization of the wells of a microplate with a dextran layer before printing of the protein array in triplicate. (B) The assay protocol and working principle is similar to the solid-phase standard indirect ELISA. After the three typical incubation steps (serum sample, conjugate, and substrate), followed by microplate reading. The reaction was visualized as brown spots which intensity correlated with antibody levels to specific viral antigen target in the array. Four results are obtainable depending on incubation with a negative control, or samples from PDCoV, PEDV, TGEV inoculation groups. Scale bar corresponds to 1 mm. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)
Figure Legend Snippet: Overview of the design, fabrication and use of the AgroDiag porcine enteric coronavirus (PEC) multiplex planar immunoassay. (A) Manufacturing steps include functionalization of the wells of a microplate with a dextran layer before printing of the protein array in triplicate. (B) The assay protocol and working principle is similar to the solid-phase standard indirect ELISA. After the three typical incubation steps (serum sample, conjugate, and substrate), followed by microplate reading. The reaction was visualized as brown spots which intensity correlated with antibody levels to specific viral antigen target in the array. Four results are obtainable depending on incubation with a negative control, or samples from PDCoV, PEDV, TGEV inoculation groups. Scale bar corresponds to 1 mm. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)

Techniques Used: Multiplex Assay, Protein Array, Indirect ELISA, Incubation, Negative Control

Related Articles

Fluorescence:

Article Title: Clinical Studies of Ci-5, Sol-gel Encapsulated Multiplex Antibody Microarray for Quantitative Fluorometric Detection of Simultaneous Five Different Tumor Antigens
Article Snippet: Here, we developed Sol-gel based antibody microarray platform for quantitative detection of five different cancer biomarkers in clinical sample simultaneously.. This kit called Ci-5, Multiplex Tumor Marker Quantitative Kit, is developed based on proprietary SG CapTM technology.. The Ci-5 has 3×5 format of microarray that contains five different antibodies for capturing multi-targets cancer biomarkers, AFP (Liver cancer), CEA (Colon cancer), PSA (Prostate cancer), CA125 (Ovarian cancer) and CA19-9 (Pancreatic cancer), which are approved by CE (Registration No. HL 60135402 0001).

Article Title: Single cell separation in microplates through micro patterning of “clickable” hydrogels
Article Snippet: .. The fluorescence images were obtained either from a fluorescence reader (FLAIR, Sensovation AG, Radolfzell, Germany) or a fluorescence microscope (inverted microscope (Nikon TS 100, #203537, Nikon GmbH, Germany)). .. In the fluorescence microscope, a metal halide (Intensilight C-HGFI, #684409, Nikon GmbH, Germany) light source and G-2 A (G-2 A, MBE45500, Nikon GmbH, Germany) fluorescence filters were used.

Article Title: Controlling Fluorescent Readout in Paper-based Analytical Devices.
Article Snippet: Paper is an ideal candidate for the development of new disposable diagnostic devices because it is a low-cost material, allows transport of the liquid on the device by capillary action, and is environmentally friendly.. Today, colorimetric analysis is most often used as a detection method for rapid tests (test strips or lateral flow devices) but usually gives only qualitative results and is limited by a relatively high detection threshold.. Here, we describe studies using fluorescence as a readout tool for paper-based diagnostics.

Article Title: Three-dimensional polymer networks and their use
Article Snippet: .. The plate was scanned in a Sensovation Fluorescence scanner to visually assess the spot morphology. ..

Article Title: Linear Cryogel Arrays: On the Fast Track for Borreliosis Detection.
Article Snippet: The detection of IgG/IgM antibodies is a crucial tool for the diagnosis of infectious diseases as they give specific information such as the stage of infection or when it approximately occurred.. In this work, a linear cryogel array (LCA) technology is described for the detection of IgG and IgM antibodies, indicative of a borreliosis infection in human sera.. The LCA consists of a transparent capillary filled with functionalized cryogel compartments.

Microscopy:

Article Title: Single cell separation in microplates through micro patterning of “clickable” hydrogels
Article Snippet: .. The fluorescence images were obtained either from a fluorescence reader (FLAIR, Sensovation AG, Radolfzell, Germany) or a fluorescence microscope (inverted microscope (Nikon TS 100, #203537, Nikon GmbH, Germany)). .. In the fluorescence microscope, a metal halide (Intensilight C-HGFI, #684409, Nikon GmbH, Germany) light source and G-2 A (G-2 A, MBE45500, Nikon GmbH, Germany) fluorescence filters were used.

Inverted Microscopy:

Article Title: Single cell separation in microplates through micro patterning of “clickable” hydrogels
Article Snippet: .. The fluorescence images were obtained either from a fluorescence reader (FLAIR, Sensovation AG, Radolfzell, Germany) or a fluorescence microscope (inverted microscope (Nikon TS 100, #203537, Nikon GmbH, Germany)). .. In the fluorescence microscope, a metal halide (Intensilight C-HGFI, #684409, Nikon GmbH, Germany) light source and G-2 A (G-2 A, MBE45500, Nikon GmbH, Germany) fluorescence filters were used.

Microarray:

Article Title: Controlling Fluorescent Readout in Paper-based Analytical Devices.
Article Snippet: Paper is an ideal candidate for the development of new disposable diagnostic devices because it is a low-cost material, allows transport of the liquid on the device by capillary action, and is environmentally friendly.. Today, colorimetric analysis is most often used as a detection method for rapid tests (test strips or lateral flow devices) but usually gives only qualitative results and is limited by a relatively high detection threshold.. Here, we describe studies using fluorescence as a readout tool for paper-based diagnostics.

other:

Article Title: Single-Color Barcoding for Multiplexed Hydrogel Bead-Based Immunoassays
Article Snippet: The fluorescent labels were read out on a fluorescence plate reader (Sensovation, SensoSpot Microarray Analyzer) in the green channel at an exposure time of 50 ms.

Software:

Article Title: Agrodiag PorCoV: A multiplex immunoassay for the differential diagnosis of porcine enteric coronaviruses
Article Snippet: .. Images of individual wells were captured by a microplate reader (Clair®, Sensovation AG) operated by the software Sensospot® (Sensovation AG). ..

Multiplex Assay:

Article Title: Agrodiag PorCoV: A multiplex immunoassay for the differential diagnosis of porcine enteric coronaviruses
Article Snippet: .. Supplementary Fig. S1 Supplementary Fig. S2 AgroDiag PEC multiplex immunoassay raw data obtained with the microplate reader (CLAIR Sensovation®) on serum samples, tested in duplicate, collected at day post-inoculation −7, 0, 7, 14, 21, 28, 35, and 42 from pigs ( n = 12, per group) experimentally inoculated with: (A) culture media (NEG); (B) porcine deltacoronavirus (PDCoV); (C) porcine epidemic diarrhea virus (PEDV); (D) transmissible gastroenteritis virus (TGEV) Purdue; (E) TGEV Miller. ..

Virus:

Article Title: Agrodiag PorCoV: A multiplex immunoassay for the differential diagnosis of porcine enteric coronaviruses
Article Snippet: .. Supplementary Fig. S1 Supplementary Fig. S2 AgroDiag PEC multiplex immunoassay raw data obtained with the microplate reader (CLAIR Sensovation®) on serum samples, tested in duplicate, collected at day post-inoculation −7, 0, 7, 14, 21, 28, 35, and 42 from pigs ( n = 12, per group) experimentally inoculated with: (A) culture media (NEG); (B) porcine deltacoronavirus (PDCoV); (C) porcine epidemic diarrhea virus (PEDV); (D) transmissible gastroenteritis virus (TGEV) Purdue; (E) TGEV Miller. ..



Similar Products

90
Agilent technologies surescan microarray scanner laser reader
Surescan Microarray Scanner Laser Reader, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+readers/pm38801463-54-16-22
Average 90 stars, based on 1 article reviews
surescan microarray scanner laser reader - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

97
Illumina Inc microarray reader iscan system
Microarray Reader Iscan System, supplied by Illumina Inc, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+readers/iScan+System/pm41037856-66-5-9
Average 97 stars, based on 1 article reviews
microarray reader iscan system - by Bioz Stars, 2026-09
97/100 stars
  Buy from Supplier

90
Sensovation ag flair microarray reader
Flair Microarray Reader, supplied by Sensovation ag, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+readers/flair+microarray+reader/pmc11893856__DataSheet1-31-19-19
Average 90 stars, based on 1 article reviews
flair microarray reader - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Fzmb GmbH microarray reader
Flowchart of the steps of the DNA <t>microarray</t> assay (created using biorender.com).
Microarray Reader, supplied by Fzmb GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+readers/inter+array/pmc11759823-250-24-28
Average 90 stars, based on 1 article reviews
microarray reader - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
SICASYS Software GmbH plate reader & microarray image analysis
Flowchart of the steps of the DNA <t>microarray</t> assay (created using biorender.com).
Plate Reader & Microarray Image Analysis, supplied by SICASYS Software GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+readers/plate+reader+++microarray+image+analysis/pm39601688-57-0-18
Average 90 stars, based on 1 article reviews
plate reader & microarray image analysis - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Illumina Inc bead array reader microarray scanner
Flowchart of the steps of the DNA <t>microarray</t> assay (created using biorender.com).
Bead Array Reader Microarray Scanner, supplied by Illumina Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+readers/microarray+scanner/pm38671330-85-25-24
Average 90 stars, based on 1 article reviews
bead array reader microarray scanner - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
GlycoTechnica Ltd lectin microarray glycostationtm reader 1200
Flowchart of the steps of the DNA <t>microarray</t> assay (created using biorender.com).
Lectin Microarray Glycostationtm Reader 1200, supplied by GlycoTechnica Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+readers/lectin+microarray+chip+lecchiptm/pm39251588-374-58-61
Average 90 stars, based on 1 article reviews
lectin microarray glycostationtm reader 1200 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Hidex 96-well microarray hidex absorbance plate reader
Flowchart of the steps of the DNA <t>microarray</t> assay (created using biorender.com).
96 Well Microarray Hidex Absorbance Plate Reader, supplied by Hidex, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microarray+readers/96+well+optiplate/pm38556634-364-12-13
Average 90 stars, based on 1 article reviews
96-well microarray hidex absorbance plate reader - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Flowchart of the steps of the DNA microarray assay (created using biorender.com).

Journal: Antibiotics

Article Title: Methicillin-Resistant Staphylococcus aureus : The Shifting Landscape in the United Arab Emirates

doi: 10.3390/antibiotics14010024

Figure Lengend Snippet: Flowchart of the steps of the DNA microarray assay (created using biorender.com).

Article Snippet: Amplification and labeling of extracted DNA were carried out, with the resulting amplicons used for DNA hybridization, and array images were taken by a microarray reader (Inter-Array by Fzmb GmbH, Bad Langensalza, Germany). shows the flowchart of the DNA microarray-based analysis [ ].

Techniques: Microarray