2d array matrixx evolution (Matrixx Initiatives)
Structured Review

2d Array Matrixx Evolution, supplied by Matrixx Initiatives, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mapcheck+2d+diode+array/2d+matrixx/pmc05689906-153-7-9
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "Practical implications for the quality assurance of modulated radiation therapy techniques using point detector arrays"
Article Title: Practical implications for the quality assurance of modulated radiation therapy techniques using point detector arrays
Journal: Journal of Applied Clinical Medical Physics
doi: 10.1002/acm2.12157
Figure Legend Snippet: Characteristics of the used 2D arrays
Techniques Used:
Related Articles
other:Article Title: Quality assurance of carbon ion and proton beams: A feasibility study for using the 2D MatriXX detector. Article Snippet: Repeating the vertical scan, the spots would now be located at different relative positions between adjacent columns of chambers. carbon ion and proton beams: A feasibility study for using the Article Title: Practical implications for the quality assurance of modulated radiation therapy techniques using point detector arrays Article Snippet: Including three of the most often used Article Title: FRoG: An independent dose and LET d prediction tool for proton therapy at ProBeam® facilities. Article Snippet: Dose distributions were measured with a Article Title: 2024 Annual Meeting Abstracts - General Poster Discussion. Article Snippet: Purpose: The application of artificial intelligence (AI) for an efficient IMRT quality assurance (QA) —which uses AI to identify IMRT plans for selective measurement — has demonstrated promising results in properly triaging plans for QA and potentially reducing the workload for measurement-based QA.. Yet its clinical implementation requires a comprehensive risk assessment to ensure patient safety.. This work evaluated our AI-assisted hybrid quality assurance (AIHQA) workflow using failure mode and effect analysis (FMEA). Article Title: Practical implications for the quality assurance of modulated radiation therapy techniques using point detector arrays Article Snippet: Using three commercially available Article Title: Effect of fluence smoothing on the quality of intensity-modulated radiation treatment plans. Article Snippet: A fluence-smoothing function applied for reducing the complexity of a treatment plan is an optional requirement in the inverse planning optimization algorithm of intensity-modulated radiation therapy (IMRT).. In this study, we investigated the consequences of fluence smoothing on the quality of highly complex and inhomogeneous plans in a treatment-planning system, Eclipse.. The smoothing function was applied both in the direction of leaf travel (X) and perpendicular to leaf travel (Y). Article Title: Evaluation of the ability of three commercially available dosimeters to detect systematic delivery errors in step-and-shoot IMRT plans Article Snippet: This was followed by the I’mRT Irradiation:Article Title: Quality assurance of carbon ion and proton beams: A feasibility study for using the 2D MatriXX detector. Article Snippet: .. The center of gravity coordinates (Xcog, Ycog) of the spots were calculated using the following formulae: carbon ion and proton beams: A feasibility study for using the |

