computer-assisted quantitative coronary arteriographic edge detection algorithm (Siemens AG)
90
Structured Review
Siemens AG
computer-assisted quantitative coronary arteriographic edge detection algorithm
Computer Assisted Quantitative Coronary Arteriographic Edge Detection Algorithm, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/edge+detection+algorithm/computer+assisted+quantitative+coronary+arteriographic+edge+detection+algorithm+acompc/us11167065-95-30-36
Average 90 stars, based on 1 article reviews
Computer Assisted Quantitative Coronary Arteriographic Edge Detection Algorithm, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/edge+detection+algorithm/computer+assisted+quantitative+coronary+arteriographic+edge+detection+algorithm+acompc/us11167065-95-30-36
Average 90 stars, based on 1 article reviews
computer-assisted quantitative coronary arteriographic edge detection algorithm - by Bioz Stars,
2026-09
90/100 stars
Images
Related Articles
other:Article Title: Inhomogeneous vasomotor effects of moderate selective and non-selective endothelin-receptor blockade in stable coronary artery disease. Article Snippet: Accepted 7 April 2009 Published Online First 3 May 2009 ABSTRACT Objective: To explore the morphological and functional effect of selective and non-selective endothelin (ET)receptor blockade in coronary artery disease (CAD).. Design: Prospective randomised controlled trial.. Setting: University hospital. Article Title: Peri-interventional Triple Therapy With Dabigatran Improves Vasomotion and Promotes Endothelialization in Porcine Coronary Stenting Model Article Snippet: Post-stent and follow-up quantitative coronary angiography (QCA) parameters were measured by means of a computer-assisted quantitative Article Title: Human recombinant activated protein C-coated stent for the prevention of restenosis in porcine coronary arteries Article Snippet: Pre-stent, post-stent, and follow-up quantitative angiographic parameters were measured with a computer-assisted quantitative Article Title: Peri-Interventional Triple Therapy with Dabigatran Modifies Vasomotion after Bare-Metal Stent Implantation in a Pig Coronary Artery Model Article Snippet: For quantitative coronary angiography after stent placement and at follow-up, we used a computer-assisted quantitative Article Title: Shellac and paclitaxel coated catheter balloons Article Snippet: Quantitative Coronary Angiography in the Efficacy Study: Pre- and post balloon dilatation, and at the 2 weeks follow up, quantitative angiographic parameters were measured by means of a computer-assisted quantitative Article Title: Shellac and paclitaxel coated catheter balloons Article Snippet: Quantitative Coronary Angiography in the Efficacy Study: Pre- and post balloon dilatation, and at the 2 weeks follow up, quantitative angiographic parameters were measured by means of a computer-assisted quantitative Article Title: Comparison of intravascular ultrasound, quantitative coronary angiography, and dual-source 64-slice computed tomography in the preprocedural assessment of significant saphenous vein graft lesions. Article Snippet: The correlation between cardiac computed tomographic (CT) and intravascular ultrasound (IVUS) assessment of saphenous vein graft (SVG) lesions has not been studied.. The aim of this study was to evaluate the accuracy of dual-source computed tomography in quantitative assessment of significant SVG lesions scheduled for percutaneous coronary intervention (PCI).. Preintervention dual-source CT (DSCT) scans were performed in consecutive patients before PCI of the SVG lesion. Article Title: Comparison of short- and long-term results of drug-eluting vs. bare metal stenting in the porcine internal carotid artery. Article Snippet: Purpose: To evaluate the development of neointimal hyperplasia after implantation of drug-eluting stents (paclitaxel) compared to bare metal stents in porcine internal carotid arteries (ICAs).. Methods: While drug-eluting stents have effectively reduced neointimal proliferation in porcine external carotid arteries, the porcine internal carotid artery (ICA) is more sensitive to shear stress and altered flow conditions.. Thus, a study was conducted to evaluate bare vs. drug-eluting stents in porcine ICAs. |