Magnetic Resonance Imaging:Article Title:
Article Snippet: .. MRI Sequences The pulse sequences on GE and equivalent on Siemens 1.5 T MRI systems were: coronal oblique (perpendicular to the hippocampal axis) T2 weighted imaging, fast spin echo sequence, TR=4500, TE=96–105, ETL=7–8 (echo train length), 20 cm × 15 cm FOV, 3mm slice, 0mm gap, 256×256 matrix and 4 NEX; coronal oblique diffusion weighted imaging (DWI), diffusion weighted echo-planar sequence, TR/TE=6000/76–105, partial Fourier, 22cm FOV, 4mm slice, 1mm gap, 128(frequency)×64(phase) matrix, diffusion sensitizing gradients in AP, SI, LR, b=1000; and T1-weighted imaging 3D coronal fast spoiled gradient-echo sequence, TR/TE/flip = 12/5/20° to 30°, (full echo), 20cm FOV, 1.5 mm slice, 124 slices, 256×192 matrix, 2 NEX. ..
Imaging:Article Title:
Article Snippet: .. MRI Sequences The pulse sequences on GE and equivalent on Siemens 1.5 T MRI systems were: coronal oblique (perpendicular to the hippocampal axis) T2 weighted imaging, fast spin echo sequence, TR=4500, TE=96–105, ETL=7–8 (echo train length), 20 cm × 15 cm FOV, 3mm slice, 0mm gap, 256×256 matrix and 4 NEX; coronal oblique diffusion weighted imaging (DWI), diffusion weighted echo-planar sequence, TR/TE=6000/76–105, partial Fourier, 22cm FOV, 4mm slice, 1mm gap, 128(frequency)×64(phase) matrix, diffusion sensitizing gradients in AP, SI, LR, b=1000; and T1-weighted imaging 3D coronal fast spoiled gradient-echo sequence, TR/TE/flip = 12/5/20° to 30°, (full echo), 20cm FOV, 1.5 mm slice, 124 slices, 256×192 matrix, 2 NEX. ..
Sequencing:Article Title:
Article Snippet: .. MRI Sequences The pulse sequences on GE and equivalent on Siemens 1.5 T MRI systems were: coronal oblique (perpendicular to the hippocampal axis) T2 weighted imaging, fast spin echo sequence, TR=4500, TE=96–105, ETL=7–8 (echo train length), 20 cm × 15 cm FOV, 3mm slice, 0mm gap, 256×256 matrix and 4 NEX; coronal oblique diffusion weighted imaging (DWI), diffusion weighted echo-planar sequence, TR/TE=6000/76–105, partial Fourier, 22cm FOV, 4mm slice, 1mm gap, 128(frequency)×64(phase) matrix, diffusion sensitizing gradients in AP, SI, LR, b=1000; and T1-weighted imaging 3D coronal fast spoiled gradient-echo sequence, TR/TE/flip = 12/5/20° to 30°, (full echo), 20cm FOV, 1.5 mm slice, 124 slices, 256×192 matrix, 2 NEX. ..
Diffusion-based Assay:Article Title:
Article Snippet: .. MRI Sequences The pulse sequences on GE and equivalent on Siemens 1.5 T MRI systems were: coronal oblique (perpendicular to the hippocampal axis) T2 weighted imaging, fast spin echo sequence, TR=4500, TE=96–105, ETL=7–8 (echo train length), 20 cm × 15 cm FOV, 3mm slice, 0mm gap, 256×256 matrix and 4 NEX; coronal oblique diffusion weighted imaging (DWI), diffusion weighted echo-planar sequence, TR/TE=6000/76–105, partial Fourier, 22cm FOV, 4mm slice, 1mm gap, 128(frequency)×64(phase) matrix, diffusion sensitizing gradients in AP, SI, LR, b=1000; and T1-weighted imaging 3D coronal fast spoiled gradient-echo sequence, TR/TE/flip = 12/5/20° to 30°, (full echo), 20cm FOV, 1.5 mm slice, 124 slices, 256×192 matrix, 2 NEX. ..
|