Review




Structured Review

Smith & Nephew cortical button fixation device
Postoperative anteroposterior (A) and lateral (B) radiographs of the left elbow obtained 7 months after Achilles tendon allograft reconstruction (October 2025), demonstrating stable <t>cortical</t> <t>button</t> <t>fixation</t> at the radial tuberosity without evidence of hardware migration, heterotopic ossification, radioulnar synostosis, or other fixation-related complications.
Cortical Button Fixation Device, supplied by Smith & Nephew, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/button+device/button/pmc13033150-4-19-24
Average 86 stars, based on 1 article reviews
cortical button fixation device - by Bioz Stars, 2026-11
86/100 stars

Images

1) Product Images from "Two-year delayed reconstruction of chronic distal biceps tendon rupture with allograft: a case report"

Article Title: Two-year delayed reconstruction of chronic distal biceps tendon rupture with allograft: a case report

Journal: Journal of Surgical Case Reports

doi: 10.1093/jscr/rjag211

Postoperative anteroposterior (A) and lateral (B) radiographs of the left elbow obtained 7 months after Achilles tendon allograft reconstruction (October 2025), demonstrating stable cortical button fixation at the radial tuberosity without evidence of hardware migration, heterotopic ossification, radioulnar synostosis, or other fixation-related complications.
Figure Legend Snippet: Postoperative anteroposterior (A) and lateral (B) radiographs of the left elbow obtained 7 months after Achilles tendon allograft reconstruction (October 2025), demonstrating stable cortical button fixation at the radial tuberosity without evidence of hardware migration, heterotopic ossification, radioulnar synostosis, or other fixation-related complications.

Techniques Used: Migration

Related Articles

Construct:

Article Title: Lesser tuberosity osteotomy repair in stemless anatomic shoulder arthroplasty: a biomechanical analysis of repair techniques.
Article Snippet: .. 125 126 Tensionable Cortical Button Construct 127 The Button construct included a combination of transosseous compression sutures and a 128 tensionable cortical button (Double Endobutton; Smith & Nephew, Andover, MD). ..

other:

Article Title: Results of arthroscopic suspension fixation for acute posterior cruciate ligament avulsion fractures in adolescents: a retrospective cohort study
Article Snippet: We further used a cortical button (Smith & Nephew, USA) comprising a titanium button and a 60-mm suture loop with a length sufficient to traverse the tibial tunnel.

Article Title: Indirect method of articular tissue repair
Article Snippet: Two #2 Ethibond sutures were looped through the two center holes of a cortical button (Endobutton, Smith & Nephew, Andover, MA).

Article Title: Two-year delayed reconstruction of chronic distal biceps tendon rupture with allograft: a case report
Article Snippet: Surgical reconstruction was performed using an Achilles tendon allograft secured proximally with a Pulvertaft weave and distally with a cortical button fixation device (EndoButtonTM, Smith & Nephew, Memphis, TN, USA) following preparation and tensioning of the graft.

Article Title: Hybrid Fixation for Syndesmotic Stabilisation: A Systematic Review of Clinical and Biomechanical Evidence
Article Snippet: The study by Patel et al. was funded by the American Orthopaedic Foot and Ankle Society, with donated suture-button devices from Smith & Nephew [ ].

Article Title: Clinical and radiographic outcomes of arthroscopic repair versus conservative management for medial meniscus posterior root tears: A comparative cohort study
Article Snippet: Sutures were retrieved through the tibial tunnel and secured using either a cortical button fixation device (EndoButton®; Smith & Nephew Inc., Memphis, TN, USA) or a 4.5-mm titanium cortical screw based on surgeon preference.

Article Title: Two-year delayed reconstruction of chronic distal biceps tendon rupture with allograft: a case report
Article Snippet: Distally, a 4.5-mm tunnel was drilled at the radial tuberosity, and fixation was achieved with a transosseous cortical button fixation device (EndoButtonTM, Smith & Nephew, Memphis, TN, USA) with the elbow held at 90° flexion and 50° supination ( ).



Similar Products

96
Psychology Software Tools 5 button chronos device
5 Button Chronos Device, supplied by Psychology Software Tools, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/button+device/Chronos/pm42251955-102-13-16
Average 96 stars, based on 1 article reviews
5 button chronos device - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

95
Psychology Software Tools celeritas button press device
Celeritas Button Press Device, supplied by Psychology Software Tools, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/button+device/Celeritas/pmc13181006-263-9-13
Average 95 stars, based on 1 article reviews
celeritas button press device - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

86
Smith & Nephew cortical button fixation device
Postoperative anteroposterior (A) and lateral (B) radiographs of the left elbow obtained 7 months after Achilles tendon allograft reconstruction (October 2025), demonstrating stable <t>cortical</t> <t>button</t> <t>fixation</t> at the radial tuberosity without evidence of hardware migration, heterotopic ossification, radioulnar synostosis, or other fixation-related complications.
Cortical Button Fixation Device, supplied by Smith & Nephew, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/button+device/button/pmc13033150-4-19-24
Average 86 stars, based on 1 article reviews
cortical button fixation device - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Smith & Nephew transosseous cortical button fixation device
(A) Intraoperative image showing the Achilles tendon allograft weaved into the retracted biceps muscle belly using a Pulvertaft technique through a single anterior approach. The prepared graft length was approximately 15 cm. (B). Distal fixation of the allograft into the radial tuberosity using a <t>transosseous</t> EndoButton following tensioning with the elbow positioned at 90° flexion and 50° supination.
Transosseous Cortical Button Fixation Device, supplied by Smith & Nephew, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/button+device/button/pmc13033150-47-16-22
Average 86 stars, based on 1 article reviews
transosseous cortical button fixation device - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

96
Psychology Software Tools button chronos device
(A) Intraoperative image showing the Achilles tendon allograft weaved into the retracted biceps muscle belly using a Pulvertaft technique through a single anterior approach. The prepared graft length was approximately 15 cm. (B). Distal fixation of the allograft into the radial tuberosity using a <t>transosseous</t> EndoButton following tensioning with the elbow positioned at 90° flexion and 50° supination.
Button Chronos Device, supplied by Psychology Software Tools, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/button+device/Chronos/10__21203_slash_rs__3__rs___8938459_slash_v1-40-19-23
Average 96 stars, based on 1 article reviews
button chronos device - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

86
Arthrex Inc suture button devices
(A) Intraoperative image showing the Achilles tendon allograft weaved into the retracted biceps muscle belly using a Pulvertaft technique through a single anterior approach. The prepared graft length was approximately 15 cm. (B). Distal fixation of the allograft into the radial tuberosity using a <t>transosseous</t> EndoButton following tensioning with the elbow positioned at 90° flexion and 50° supination.
Suture Button Devices, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/button+device/button+suture/pmc12832051-29-4-11
Average 86 stars, based on 1 article reviews
suture button devices - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Smith & Nephew suture button devices
(A) Intraoperative image showing the Achilles tendon allograft weaved into the retracted biceps muscle belly using a Pulvertaft technique through a single anterior approach. The prepared graft length was approximately 15 cm. (B). Distal fixation of the allograft into the radial tuberosity using a <t>transosseous</t> EndoButton following tensioning with the elbow positioned at 90° flexion and 50° supination.
Suture Button Devices, supplied by Smith & Nephew, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/button+device/button/pmc12786473-271-18-21
Average 86 stars, based on 1 article reviews
suture button devices - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Arthrex Inc suture button device
(A) Intraoperative image showing the Achilles tendon allograft weaved into the retracted biceps muscle belly using a Pulvertaft technique through a single anterior approach. The prepared graft length was approximately 15 cm. (B). Distal fixation of the allograft into the radial tuberosity using a <t>transosseous</t> EndoButton following tensioning with the elbow positioned at 90° flexion and 50° supination.
Suture Button Device, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/button+device/button+suture/pmc12786473-162-6-9
Average 86 stars, based on 1 article reviews
suture button device - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


Postoperative anteroposterior (A) and lateral (B) radiographs of the left elbow obtained 7 months after Achilles tendon allograft reconstruction (October 2025), demonstrating stable cortical button fixation at the radial tuberosity without evidence of hardware migration, heterotopic ossification, radioulnar synostosis, or other fixation-related complications.

Journal: Journal of Surgical Case Reports

Article Title: Two-year delayed reconstruction of chronic distal biceps tendon rupture with allograft: a case report

doi: 10.1093/jscr/rjag211

Figure Lengend Snippet: Postoperative anteroposterior (A) and lateral (B) radiographs of the left elbow obtained 7 months after Achilles tendon allograft reconstruction (October 2025), demonstrating stable cortical button fixation at the radial tuberosity without evidence of hardware migration, heterotopic ossification, radioulnar synostosis, or other fixation-related complications.

Article Snippet: Surgical reconstruction was performed using an Achilles tendon allograft secured proximally with a Pulvertaft weave and distally with a cortical button fixation device (EndoButtonTM, Smith & Nephew, Memphis, TN, USA) following preparation and tensioning of the graft.

Techniques: Migration

(A) Intraoperative image showing the Achilles tendon allograft weaved into the retracted biceps muscle belly using a Pulvertaft technique through a single anterior approach. The prepared graft length was approximately 15 cm. (B). Distal fixation of the allograft into the radial tuberosity using a transosseous EndoButton following tensioning with the elbow positioned at 90° flexion and 50° supination.

Journal: Journal of Surgical Case Reports

Article Title: Two-year delayed reconstruction of chronic distal biceps tendon rupture with allograft: a case report

doi: 10.1093/jscr/rjag211

Figure Lengend Snippet: (A) Intraoperative image showing the Achilles tendon allograft weaved into the retracted biceps muscle belly using a Pulvertaft technique through a single anterior approach. The prepared graft length was approximately 15 cm. (B). Distal fixation of the allograft into the radial tuberosity using a transosseous EndoButton following tensioning with the elbow positioned at 90° flexion and 50° supination.

Article Snippet: Distally, a 4.5-mm tunnel was drilled at the radial tuberosity, and fixation was achieved with a transosseous cortical button fixation device (EndoButtonTM, Smith & Nephew, Memphis, TN, USA) with the elbow held at 90° flexion and 50° supination ( ).

Techniques: