Review




Structured Review

Ashland Inc detector arrays
Detector Arrays, supplied by Ashland Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+detector/arrays+detector/pmc13202586-72-42-76
Average 86 stars, based on 1 article reviews
detector arrays - by Bioz Stars, 2026-11
86/100 stars

Images

Related Articles

Software:

Article Title: A survey of practice patterns for patient-specific quality assurance on behalf of the ESTRO dosimetry & quality assurance focus group
Article Snippet: .. They can include verification of the planned dose calculation using independent software tools (for example Mobius3D (Varian, USA), DoseCheck TM (Sun Nuclear, USA) or SciMoCa TM (IBA, Germany)), measurement-based approaches for the verification of the delivered dose in specialised phantoms with embedded detector arrays (like Octavius (PTW, Germany), ArcCHECK (Sun Nuclear, USA), Delta4 (Scandidos, Sweden) or MatriXX (IBA, Germany)), or in geometric and/or anthropomorphic phantoms with point detectors and/or radiochromic films (such as Gafchromic TM EBT4 (Ashland, USA) or OrthoChromic (Oncology Imaging Systems, UK)), or verification of the fluence or dose delivered on the electronic portal imager (for example by using the solutions of Portal Dosimetry (Varian, USA), Epiqa TM (Epidos, Slovak Republic), PerFRACTION − Fraction 0 (Sun Nuclear, USA)). .. Software tools which analyse and/or compute dose using the information from treatment log files (for example myQA iON (IBA, Germany) or LINACwatch (Qualiformed, France)) and or transmission fluence captured on the EPID, namely transit in-vivo dosimetry approaches (e.g PerFRACTION TM (Sun Nuclear, USA) or VeriQA (PTW, Germany)) can also be included.

Imaging:

Article Title: A survey of practice patterns for patient-specific quality assurance on behalf of the ESTRO dosimetry & quality assurance focus group
Article Snippet: .. They can include verification of the planned dose calculation using independent software tools (for example Mobius3D (Varian, USA), DoseCheck TM (Sun Nuclear, USA) or SciMoCa TM (IBA, Germany)), measurement-based approaches for the verification of the delivered dose in specialised phantoms with embedded detector arrays (like Octavius (PTW, Germany), ArcCHECK (Sun Nuclear, USA), Delta4 (Scandidos, Sweden) or MatriXX (IBA, Germany)), or in geometric and/or anthropomorphic phantoms with point detectors and/or radiochromic films (such as Gafchromic TM EBT4 (Ashland, USA) or OrthoChromic (Oncology Imaging Systems, UK)), or verification of the fluence or dose delivered on the electronic portal imager (for example by using the solutions of Portal Dosimetry (Varian, USA), Epiqa TM (Epidos, Slovak Republic), PerFRACTION − Fraction 0 (Sun Nuclear, USA)). .. Software tools which analyse and/or compute dose using the information from treatment log files (for example myQA iON (IBA, Germany) or LINACwatch (Qualiformed, France)) and or transmission fluence captured on the EPID, namely transit in-vivo dosimetry approaches (e.g PerFRACTION TM (Sun Nuclear, USA) or VeriQA (PTW, Germany)) can also be included.



Similar Products

98
Dectris AG eiger2 r cdte 1m hybrid pixel array detector
Eiger2 R Cdte 1m Hybrid Pixel Array Detector, supplied by Dectris AG, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+detector/eiger2/pm42929618-201-32-31
Average 98 stars, based on 1 article reviews
eiger2 r cdte 1m hybrid pixel array detector - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

98
Dectris AG pixel array detector
Pixel Array Detector, supplied by Dectris AG, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+detector/eiger2/pmc13672795-135-15-20
Average 98 stars, based on 1 article reviews
pixel array detector - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

95
Agilent technologies diode array matrix detector
Diode Array Matrix Detector, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+detector/Bio+LC/10__1016_slash_j__jfca__2026__109492-73-13-18
Average 95 stars, based on 1 article reviews
diode array matrix detector - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

99
Hitachi Ltd primaide hplcdad diode array detector
Primaide Hplcdad Diode Array Detector, supplied by Hitachi Ltd, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+detector/Primaide/10__1038_slash_s41598___026___66444___x-247-13-12
Average 99 stars, based on 1 article reviews
primaide hplcdad diode array detector - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

98
JASCO Inc photodiode array detector
Photodiode Array Detector, supplied by JASCO Inc, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+detector/JASCO+UV+Visible+PDA+Detectors/10__1016_slash_j__electacta__2026__149651-101-29-16
Average 98 stars, based on 1 article reviews
photodiode array detector - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

98
JASCO Inc photo diode array detector
Photo Diode Array Detector, supplied by JASCO Inc, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+detector/JASCO+UV+Visible+PDA+Detectors/pm42476277-84-2-6
Average 98 stars, based on 1 article reviews
photo diode array detector - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

98
JASCO Inc diode array detector
Diode Array Detector, supplied by JASCO Inc, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+detector/JASCO+UV+Visible+PDA+Detectors/pmc13362923-207-13-17
Average 98 stars, based on 1 article reviews
diode array detector - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

98
Oxford Instruments idus ingaas 491 array nir detector
Idus Ingaas 491 Array Nir Detector, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+detector/iDus+InGaAs/pm42271052-449-8-7
Average 98 stars, based on 1 article reviews
idus ingaas 491 array nir detector - by Bioz Stars, 2026-11
98/100 stars
  Buy from Supplier

86
Liverage Biomedical Inc crossmini 2d strip ionization chamber detector array
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
Crossmini 2d Strip Ionization Chamber Detector Array, supplied by Liverage Biomedical Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/array+detector/pmc13138202-56-7-14
Average 86 stars, based on 1 article reviews
crossmini 2d strip ionization chamber detector array - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


Signal amplitude from the CROSSmini detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).

Journal: International Journal of Particle Therapy

Article Title: Phenomenological Study of Intra-Spill Break Spots in Dose-Driven Continuous Scanning Proton Therapy

doi: 10.1016/j.ijpt.2026.101315

Figure Lengend Snippet: Signal amplitude from the CROSSmini detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).

Article Snippet: The beam current was measured using a CROSSmini 2D strip ionization chamber detector array (Liverage Biomedical Inc, Taiwan) positioned at the isocenter plane.

Techniques:

Signal amplitude from the CROSSmini detector with signal fitting. shows the signal amplitude as a function of time measured by the CROSSmini detector and the piecewise fittings. Figures A, B, and C are measurements for energy level 70.2 MeV with nominal beam current 8, 14, and 20 MU/s, respectively. Figures D, E, and F are the measurements for energy level 228.7 MeV with nominal beam current 8, 14, and 20 MU/s, respectively.

Journal: International Journal of Particle Therapy

Article Title: Phenomenological Study of Intra-Spill Break Spots in Dose-Driven Continuous Scanning Proton Therapy

doi: 10.1016/j.ijpt.2026.101315

Figure Lengend Snippet: Signal amplitude from the CROSSmini detector with signal fitting. shows the signal amplitude as a function of time measured by the CROSSmini detector and the piecewise fittings. Figures A, B, and C are measurements for energy level 70.2 MeV with nominal beam current 8, 14, and 20 MU/s, respectively. Figures D, E, and F are the measurements for energy level 228.7 MeV with nominal beam current 8, 14, and 20 MU/s, respectively.

Article Snippet: The beam current was measured using a CROSSmini 2D strip ionization chamber detector array (Liverage Biomedical Inc, Taiwan) positioned at the isocenter plane.

Techniques:

t rise comparison between analytical and measured. The blue and red plots represent the analytically derived t rise and CROSSmini measured t rise , respectively, across the various nominal beam current settings.

Journal: International Journal of Particle Therapy

Article Title: Phenomenological Study of Intra-Spill Break Spots in Dose-Driven Continuous Scanning Proton Therapy

doi: 10.1016/j.ijpt.2026.101315

Figure Lengend Snippet: t rise comparison between analytical and measured. The blue and red plots represent the analytically derived t rise and CROSSmini measured t rise , respectively, across the various nominal beam current settings.

Article Snippet: The beam current was measured using a CROSSmini 2D strip ionization chamber detector array (Liverage Biomedical Inc, Taiwan) positioned at the isocenter plane.

Techniques: Comparison, Derivative Assay