Journal: bioRxiv
Article Title: Zwitterionic hydrogel designs for conducting polymers enable bioelectronics with suppressed foreign body responses
doi: 10.1101/2025.10.31.683260
Figure Lengend Snippet: a , Total counts of macrophages associated with each type of implant, determined by flow cytometry and 4-week post-implantation. Macrophages were defined as F4/80 + cells. ZIPH-3c is consistently associated with the greatest number of macrophages. b , iNOS + Arg-1 ‒ / iNOS ‒ Arg-1 + macrophage ratios associated with each implant, determined by flow cytometry at 4 weeks post-implantation. iNOS + Arg-1 ‒ macrophages are considered to be M1-like and iNOS ‒ Arg-1 + macrophages are considered to be M2-like. ZIPH-3c is associated with the most M1-like macrophages. c , CD86 + CD206 ‒ / CD86 ‒ CD206 + macrophage ratios associated with each implant, determined by flow cytometry at 4 weeks post-implantation. CD86 + CD206 ‒ macrophages are considered to be M1-like and CD86 ‒ CD206 + macrophages are considered to be M2-like. ZIPH-3c is associated with the most M1-like macrophages. d , Representative immunofluorescence microscopy images of tissues stained with F4/80 (macrophage), CD86 (M1), and CD206 (M2). Locations of implants appear clear and are marked by asterisks. e , Percentage of CD3 + T cells that are T-bet + . T cells associated with ZIPH-3c have a high fraction of T-bet + cells. f , Percentage of CD4 + T helper cells that are FoxP3 + T reg s. CD4+ T helper cells associated with ZIPH-3c have a high fraction of FoxP3 + T reg s. g-h , Key cytokines associated with each implant, determined via LegendPlex assay at 1-week (g-h) and 4-week (i-j) post-implantation. MCP-1 is consistently upregulated for both ZIPH-3c and ZIPH-u. k , Total counts of neutrophils associated with each implant, determined by flow cytometry 1-week post-implantation. Neutrophils were defined as Ly-6G + cells. l , Complement C3a concentration associated with each implant, determined by ELISA 1-week post-implantation. The high number of neutrophils is correlated with the generation of C3a. PSB has a distinctly higher neutrophil number and C3a concentration than the rest of the hydrogels that contain PSS. Error bars, mean ± s.d. N = 5-6 mice per treatment. One-way ANOVA was used for statistical comparison of multiple means. *, P < 0.05; **, P < 0.01; ****, P < 0.0001; ##, P < 0.01 compared to rest; ####, P < 0.0001 compared to rest.
Article Snippet: A C3a ELISA kit (Novus Biologicals), a decorin ELISA kit (R & D Systems), and an endostatin ELISA kit (Abcam) were used following manufacturer’s instructions.
Techniques: Flow Cytometry, Immunofluorescence, Microscopy, Staining, Concentration Assay, Enzyme-linked Immunosorbent Assay, Comparison