Agilent technologies situ hybridization kit plus
Situ Hybridization Kit Plus, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/situ hybridization kit plus/product/Agilent technologies
Average 93 stars, based on 1 article reviews
situ hybridization kit plus - by Bioz Stars, 2026-02
93/100 stars
  Buy from Supplier

93
GE Healthcare crna cy3 fluorescence labeling
Crna Cy3 Fluorescence Labeling, supplied by GE Healthcare, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/crna cy3 fluorescence labeling/product/GE Healthcare
Average 93 stars, based on 1 article reviews
crna cy3 fluorescence labeling - by Bioz Stars, 2026-02
93/100 stars
  Buy from Supplier

90
Agilent technologies dna microarray scanner g2565ba
Dna Microarray Scanner G2565ba, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/dna microarray scanner g2565ba/product/Agilent technologies
Average 90 stars, based on 1 article reviews
dna microarray scanner g2565ba - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies microarray scanner
Specificity and sensitivity of used anti-methylcytosine antibody. ( A ) The antibody properties were assessed by an indirect immunofluorescence assay, in which the monoclonal anti-MeC antibody for this study — used at the concentration of 1 μg/ml in combination with a secondary antibody (Cy3-conjugated anti-mouse IgG1 at 5 μg/ml), i.e. at the same concentrations as in the cellular assay — was hybridized to a spotted array with two types of short 24-mer oligonucleotides immobilized onto a glass slide: C-oligo that included two CG dinucleotides and its methylated counterpart, the MeC-oligo printed at various dilutions that correlate with different approximate CpG copy numbers (10 10 –10 4 ) . Each DNA probe was spotted as octuple. The specific antibody, detected with a <t>microarray</t> scanner at 5 microns resolution, shows best signal-to-noise (background and non-specific binding to unmethylated C-oligo) ratio at a copy number of 10 10 . The signal (false-colored in green) decreases in a CpG copy number-dependent manner. ( B ) Similar average intensities were obtained, when a sub-area (magenta box in Figure A) of the same array was subjected to confocal scanning microscopy at 200 nm horizontal resolution. The line scan (magenta) shows the more detailed intensity profile across the four different types of spots and the intermediate gaps (coated glass slide/background).
Microarray Scanner, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/microarray scanner/product/Agilent technologies
Average 90 stars, based on 1 article reviews
microarray scanner - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies dna microarray scanner
Specificity and sensitivity of used anti-methylcytosine antibody. ( A ) The antibody properties were assessed by an indirect immunofluorescence assay, in which the monoclonal anti-MeC antibody for this study — used at the concentration of 1 μg/ml in combination with a secondary antibody (Cy3-conjugated anti-mouse IgG1 at 5 μg/ml), i.e. at the same concentrations as in the cellular assay — was hybridized to a spotted array with two types of short 24-mer oligonucleotides immobilized onto a glass slide: C-oligo that included two CG dinucleotides and its methylated counterpart, the MeC-oligo printed at various dilutions that correlate with different approximate CpG copy numbers (10 10 –10 4 ) . Each DNA probe was spotted as octuple. The specific antibody, detected with a <t>microarray</t> scanner at 5 microns resolution, shows best signal-to-noise (background and non-specific binding to unmethylated C-oligo) ratio at a copy number of 10 10 . The signal (false-colored in green) decreases in a CpG copy number-dependent manner. ( B ) Similar average intensities were obtained, when a sub-area (magenta box in Figure A) of the same array was subjected to confocal scanning microscopy at 200 nm horizontal resolution. The line scan (magenta) shows the more detailed intensity profile across the four different types of spots and the intermediate gaps (coated glass slide/background).
Dna Microarray Scanner, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/dna microarray scanner/product/Agilent technologies
Average 90 stars, based on 1 article reviews
dna microarray scanner - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies laser microarray scanner g2565ba fluorescent scanner
Specificity and sensitivity of used anti-methylcytosine antibody. ( A ) The antibody properties were assessed by an indirect immunofluorescence assay, in which the monoclonal anti-MeC antibody for this study — used at the concentration of 1 μg/ml in combination with a secondary antibody (Cy3-conjugated anti-mouse IgG1 at 5 μg/ml), i.e. at the same concentrations as in the cellular assay — was hybridized to a spotted array with two types of short 24-mer oligonucleotides immobilized onto a glass slide: C-oligo that included two CG dinucleotides and its methylated counterpart, the MeC-oligo printed at various dilutions that correlate with different approximate CpG copy numbers (10 10 –10 4 ) . Each DNA probe was spotted as octuple. The specific antibody, detected with a <t>microarray</t> scanner at 5 microns resolution, shows best signal-to-noise (background and non-specific binding to unmethylated C-oligo) ratio at a copy number of 10 10 . The signal (false-colored in green) decreases in a CpG copy number-dependent manner. ( B ) Similar average intensities were obtained, when a sub-area (magenta box in Figure A) of the same array was subjected to confocal scanning microscopy at 200 nm horizontal resolution. The line scan (magenta) shows the more detailed intensity profile across the four different types of spots and the intermediate gaps (coated glass slide/background).
Laser Microarray Scanner G2565ba Fluorescent Scanner, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/laser microarray scanner g2565ba fluorescent scanner/product/Agilent technologies
Average 90 stars, based on 1 article reviews
laser microarray scanner g2565ba fluorescent scanner - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies laser confocal scanner
Specificity and sensitivity of used anti-methylcytosine antibody. ( A ) The antibody properties were assessed by an indirect immunofluorescence assay, in which the monoclonal anti-MeC antibody for this study — used at the concentration of 1 μg/ml in combination with a secondary antibody (Cy3-conjugated anti-mouse IgG1 at 5 μg/ml), i.e. at the same concentrations as in the cellular assay — was hybridized to a spotted array with two types of short 24-mer oligonucleotides immobilized onto a glass slide: C-oligo that included two CG dinucleotides and its methylated counterpart, the MeC-oligo printed at various dilutions that correlate with different approximate CpG copy numbers (10 10 –10 4 ) . Each DNA probe was spotted as octuple. The specific antibody, detected with a <t>microarray</t> scanner at 5 microns resolution, shows best signal-to-noise (background and non-specific binding to unmethylated C-oligo) ratio at a copy number of 10 10 . The signal (false-colored in green) decreases in a CpG copy number-dependent manner. ( B ) Similar average intensities were obtained, when a sub-area (magenta box in Figure A) of the same array was subjected to confocal scanning microscopy at 200 nm horizontal resolution. The line scan (magenta) shows the more detailed intensity profile across the four different types of spots and the intermediate gaps (coated glass slide/background).
Laser Confocal Scanner, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/laser confocal scanner/product/Agilent technologies
Average 90 stars, based on 1 article reviews
laser confocal scanner - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies hybridization
Specificity and sensitivity of used anti-methylcytosine antibody. ( A ) The antibody properties were assessed by an indirect immunofluorescence assay, in which the monoclonal anti-MeC antibody for this study — used at the concentration of 1 μg/ml in combination with a secondary antibody (Cy3-conjugated anti-mouse IgG1 at 5 μg/ml), i.e. at the same concentrations as in the cellular assay — was hybridized to a spotted array with two types of short 24-mer oligonucleotides immobilized onto a glass slide: C-oligo that included two CG dinucleotides and its methylated counterpart, the MeC-oligo printed at various dilutions that correlate with different approximate CpG copy numbers (10 10 –10 4 ) . Each DNA probe was spotted as octuple. The specific antibody, detected with a <t>microarray</t> scanner at 5 microns resolution, shows best signal-to-noise (background and non-specific binding to unmethylated C-oligo) ratio at a copy number of 10 10 . The signal (false-colored in green) decreases in a CpG copy number-dependent manner. ( B ) Similar average intensities were obtained, when a sub-area (magenta box in Figure A) of the same array was subjected to confocal scanning microscopy at 200 nm horizontal resolution. The line scan (magenta) shows the more detailed intensity profile across the four different types of spots and the intermediate gaps (coated glass slide/background).
Hybridization, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hybridization/product/Agilent technologies
Average 90 stars, based on 1 article reviews
hybridization - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies genechip
Specificity and sensitivity of used anti-methylcytosine antibody. ( A ) The antibody properties were assessed by an indirect immunofluorescence assay, in which the monoclonal anti-MeC antibody for this study — used at the concentration of 1 μg/ml in combination with a secondary antibody (Cy3-conjugated anti-mouse IgG1 at 5 μg/ml), i.e. at the same concentrations as in the cellular assay — was hybridized to a spotted array with two types of short 24-mer oligonucleotides immobilized onto a glass slide: C-oligo that included two CG dinucleotides and its methylated counterpart, the MeC-oligo printed at various dilutions that correlate with different approximate CpG copy numbers (10 10 –10 4 ) . Each DNA probe was spotted as octuple. The specific antibody, detected with a <t>microarray</t> scanner at 5 microns resolution, shows best signal-to-noise (background and non-specific binding to unmethylated C-oligo) ratio at a copy number of 10 10 . The signal (false-colored in green) decreases in a CpG copy number-dependent manner. ( B ) Similar average intensities were obtained, when a sub-area (magenta box in Figure A) of the same array was subjected to confocal scanning microscopy at 200 nm horizontal resolution. The line scan (magenta) shows the more detailed intensity profile across the four different types of spots and the intermediate gaps (coated glass slide/background).
Genechip, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/genechip/product/Agilent technologies
Average 90 stars, based on 1 article reviews
genechip - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies dearray software
Specificity and sensitivity of used anti-methylcytosine antibody. ( A ) The antibody properties were assessed by an indirect immunofluorescence assay, in which the monoclonal anti-MeC antibody for this study — used at the concentration of 1 μg/ml in combination with a secondary antibody (Cy3-conjugated anti-mouse IgG1 at 5 μg/ml), i.e. at the same concentrations as in the cellular assay — was hybridized to a spotted array with two types of short 24-mer oligonucleotides immobilized onto a glass slide: C-oligo that included two CG dinucleotides and its methylated counterpart, the MeC-oligo printed at various dilutions that correlate with different approximate CpG copy numbers (10 10 –10 4 ) . Each DNA probe was spotted as octuple. The specific antibody, detected with a <t>microarray</t> scanner at 5 microns resolution, shows best signal-to-noise (background and non-specific binding to unmethylated C-oligo) ratio at a copy number of 10 10 . The signal (false-colored in green) decreases in a CpG copy number-dependent manner. ( B ) Similar average intensities were obtained, when a sub-area (magenta box in Figure A) of the same array was subjected to confocal scanning microscopy at 200 nm horizontal resolution. The line scan (magenta) shows the more detailed intensity profile across the four different types of spots and the intermediate gaps (coated glass slide/background).
Dearray Software, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/dearray software/product/Agilent technologies
Average 90 stars, based on 1 article reviews
dearray software - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies fluorescent cyanine 3-ctp–labeled crna
Specificity and sensitivity of used anti-methylcytosine antibody. ( A ) The antibody properties were assessed by an indirect immunofluorescence assay, in which the monoclonal anti-MeC antibody for this study — used at the concentration of 1 μg/ml in combination with a secondary antibody (Cy3-conjugated anti-mouse IgG1 at 5 μg/ml), i.e. at the same concentrations as in the cellular assay — was hybridized to a spotted array with two types of short 24-mer oligonucleotides immobilized onto a glass slide: C-oligo that included two CG dinucleotides and its methylated counterpart, the MeC-oligo printed at various dilutions that correlate with different approximate CpG copy numbers (10 10 –10 4 ) . Each DNA probe was spotted as octuple. The specific antibody, detected with a <t>microarray</t> scanner at 5 microns resolution, shows best signal-to-noise (background and non-specific binding to unmethylated C-oligo) ratio at a copy number of 10 10 . The signal (false-colored in green) decreases in a CpG copy number-dependent manner. ( B ) Similar average intensities were obtained, when a sub-area (magenta box in Figure A) of the same array was subjected to confocal scanning microscopy at 200 nm horizontal resolution. The line scan (magenta) shows the more detailed intensity profile across the four different types of spots and the intermediate gaps (coated glass slide/background).
Fluorescent Cyanine 3 Ctp–Labeled Crna, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fluorescent cyanine 3-ctp–labeled crna/product/Agilent technologies
Average 90 stars, based on 1 article reviews
fluorescent cyanine 3-ctp–labeled crna - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

90
Agilent technologies feature extraction software version 11
Specificity and sensitivity of used anti-methylcytosine antibody. ( A ) The antibody properties were assessed by an indirect immunofluorescence assay, in which the monoclonal anti-MeC antibody for this study — used at the concentration of 1 μg/ml in combination with a secondary antibody (Cy3-conjugated anti-mouse IgG1 at 5 μg/ml), i.e. at the same concentrations as in the cellular assay — was hybridized to a spotted array with two types of short 24-mer oligonucleotides immobilized onto a glass slide: C-oligo that included two CG dinucleotides and its methylated counterpart, the MeC-oligo printed at various dilutions that correlate with different approximate CpG copy numbers (10 10 –10 4 ) . Each DNA probe was spotted as octuple. The specific antibody, detected with a <t>microarray</t> scanner at 5 microns resolution, shows best signal-to-noise (background and non-specific binding to unmethylated C-oligo) ratio at a copy number of 10 10 . The signal (false-colored in green) decreases in a CpG copy number-dependent manner. ( B ) Similar average intensities were obtained, when a sub-area (magenta box in Figure A) of the same array was subjected to confocal scanning microscopy at 200 nm horizontal resolution. The line scan (magenta) shows the more detailed intensity profile across the four different types of spots and the intermediate gaps (coated glass slide/background).
Feature Extraction Software Version 11, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/feature extraction software version 11/product/Agilent technologies
Average 90 stars, based on 1 article reviews
feature extraction software version 11 - by Bioz Stars, 2026-02
90/100 stars
  Buy from Supplier

Image Search Results


Specificity and sensitivity of used anti-methylcytosine antibody. ( A ) The antibody properties were assessed by an indirect immunofluorescence assay, in which the monoclonal anti-MeC antibody for this study — used at the concentration of 1 μg/ml in combination with a secondary antibody (Cy3-conjugated anti-mouse IgG1 at 5 μg/ml), i.e. at the same concentrations as in the cellular assay — was hybridized to a spotted array with two types of short 24-mer oligonucleotides immobilized onto a glass slide: C-oligo that included two CG dinucleotides and its methylated counterpart, the MeC-oligo printed at various dilutions that correlate with different approximate CpG copy numbers (10 10 –10 4 ) . Each DNA probe was spotted as octuple. The specific antibody, detected with a microarray scanner at 5 microns resolution, shows best signal-to-noise (background and non-specific binding to unmethylated C-oligo) ratio at a copy number of 10 10 . The signal (false-colored in green) decreases in a CpG copy number-dependent manner. ( B ) Similar average intensities were obtained, when a sub-area (magenta box in Figure A) of the same array was subjected to confocal scanning microscopy at 200 nm horizontal resolution. The line scan (magenta) shows the more detailed intensity profile across the four different types of spots and the intermediate gaps (coated glass slide/background).

Journal: BMC Pharmacology & Toxicology

Article Title: 3-D DNA methylation phenotypes correlate with cytotoxicity levels in prostate and liver cancer cell models

doi: 10.1186/2050-6511-14-11

Figure Lengend Snippet: Specificity and sensitivity of used anti-methylcytosine antibody. ( A ) The antibody properties were assessed by an indirect immunofluorescence assay, in which the monoclonal anti-MeC antibody for this study — used at the concentration of 1 μg/ml in combination with a secondary antibody (Cy3-conjugated anti-mouse IgG1 at 5 μg/ml), i.e. at the same concentrations as in the cellular assay — was hybridized to a spotted array with two types of short 24-mer oligonucleotides immobilized onto a glass slide: C-oligo that included two CG dinucleotides and its methylated counterpart, the MeC-oligo printed at various dilutions that correlate with different approximate CpG copy numbers (10 10 –10 4 ) . Each DNA probe was spotted as octuple. The specific antibody, detected with a microarray scanner at 5 microns resolution, shows best signal-to-noise (background and non-specific binding to unmethylated C-oligo) ratio at a copy number of 10 10 . The signal (false-colored in green) decreases in a CpG copy number-dependent manner. ( B ) Similar average intensities were obtained, when a sub-area (magenta box in Figure A) of the same array was subjected to confocal scanning microscopy at 200 nm horizontal resolution. The line scan (magenta) shows the more detailed intensity profile across the four different types of spots and the intermediate gaps (coated glass slide/background).

Article Snippet: Fluorescence detection was performed comparatively at 5 microns resolution with a microarray scanner (G2565BA, Agilent Technologies) equipped with a helium-neon laser (633 nm) to excite Cy3, and the above-mentioned confocal microscope with a Plan-Apo 10X 0.7 lens.

Techniques: Immunofluorescence, Concentration Assay, Methylation, Microarray, Binding Assay, Microscopy