two-photon microscope Search Results


96
Carl Zeiss two photon microscope
Two Photon Microscope, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/two photon microscope/product/Carl Zeiss
Average 96 stars, based on 1 article reviews
two photon microscope - by Bioz Stars, 2026-05
96/100 stars
  Buy from Supplier

86
Thorlabs twophoton microscope
Twophoton Microscope, supplied by Thorlabs, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/twophoton microscope/product/Thorlabs
Average 86 stars, based on 1 article reviews
twophoton microscope - by Bioz Stars, 2026-05
86/100 stars
  Buy from Supplier

90
Carl Zeiss twophoton microscope
Twophoton Microscope, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/twophoton microscope/product/Carl Zeiss
Average 90 stars, based on 1 article reviews
twophoton microscope - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Femtonics inc femtosmart-dual microscope
Femtosmart Dual Microscope, supplied by Femtonics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/femtosmart-dual microscope/product/Femtonics inc
Average 90 stars, based on 1 article reviews
femtosmart-dual microscope - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Sutter Instrument Company 2-photon microscope mom scope
2 Photon Microscope Mom Scope, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/2-photon microscope mom scope/product/Sutter Instrument Company
Average 90 stars, based on 1 article reviews
2-photon microscope mom scope - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Sutter Instrument Company movable objective microscope two-photon setup sutter instruments
Movable Objective Microscope Two Photon Setup Sutter Instruments, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/movable objective microscope two-photon setup sutter instruments/product/Sutter Instrument Company
Average 90 stars, based on 1 article reviews
movable objective microscope two-photon setup sutter instruments - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
JenLab GmbH modified two-photon microscope dermainspect
Modified Two Photon Microscope Dermainspect, supplied by JenLab GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/modified two-photon microscope dermainspect/product/JenLab GmbH
Average 90 stars, based on 1 article reviews
modified two-photon microscope dermainspect - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
T.I.L.L Photonics two-photon microscope
Two Photon Microscope, supplied by T.I.L.L Photonics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/two-photon microscope/product/T.I.L.L Photonics
Average 90 stars, based on 1 article reviews
two-photon microscope - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Femtonics inc two-photon microscope (femtosmart series
a: The implantable biohybrid nerve model with a PDMS based nerve channel. b: Magnification of the biohybrid axon guidance structure that is implanted on the cortex. The flexible PDMS nerve channel can be implanted into the brain to target the visual thalamus. c: Biohybrid implant in which the PDMS channel has been replaced with a GelSH-GelNB hydrogel conduit. d: Schematic of the biohybrid implant. The microfluidic axon guidance structure is aligned on top of the Pt-based microelectrode array and seeded with neural spheroids. The implantable nerve channel is made of PDMS with an axon outlet at the end or consists of a GelSH-GelNB based hydrogel conduit vertically fabricated on top of the axon outlet. Neural spheroids are seeded into each of the 16 seeding wells to grow axons towards the nerve channel. e: The biohybrid implant is flipped around and implanted onto the cortical surface of a craniotomized mouse brain. The PDMS or hydrogel nerve channel is directed towards the lateral geniculate nucleus (LGN). f: The implant is fixed onto the mouse head using a glass window and dental cement. A headbar enables subsequent mounting on a 2-Photon <t>microscope</t> for imaging. During stimulation experiments the implant is connected through an omnetics connector.
Two Photon Microscope (Femtosmart Series, supplied by Femtonics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/two-photon microscope (femtosmart series/product/Femtonics inc
Average 90 stars, based on 1 article reviews
two-photon microscope (femtosmart series - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Femtonics inc femto 2d high sensitivity galvanoscanner-based two-photon microscope system
a: The implantable biohybrid nerve model with a PDMS based nerve channel. b: Magnification of the biohybrid axon guidance structure that is implanted on the cortex. The flexible PDMS nerve channel can be implanted into the brain to target the visual thalamus. c: Biohybrid implant in which the PDMS channel has been replaced with a GelSH-GelNB hydrogel conduit. d: Schematic of the biohybrid implant. The microfluidic axon guidance structure is aligned on top of the Pt-based microelectrode array and seeded with neural spheroids. The implantable nerve channel is made of PDMS with an axon outlet at the end or consists of a GelSH-GelNB based hydrogel conduit vertically fabricated on top of the axon outlet. Neural spheroids are seeded into each of the 16 seeding wells to grow axons towards the nerve channel. e: The biohybrid implant is flipped around and implanted onto the cortical surface of a craniotomized mouse brain. The PDMS or hydrogel nerve channel is directed towards the lateral geniculate nucleus (LGN). f: The implant is fixed onto the mouse head using a glass window and dental cement. A headbar enables subsequent mounting on a 2-Photon <t>microscope</t> for imaging. During stimulation experiments the implant is connected through an omnetics connector.
Femto 2d High Sensitivity Galvanoscanner Based Two Photon Microscope System, supplied by Femtonics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/femto 2d high sensitivity galvanoscanner-based two-photon microscope system/product/Femtonics inc
Average 90 stars, based on 1 article reviews
femto 2d high sensitivity galvanoscanner-based two-photon microscope system - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Sutter Instrument Company two-photon microscopy movable objective microscope
a: The implantable biohybrid nerve model with a PDMS based nerve channel. b: Magnification of the biohybrid axon guidance structure that is implanted on the cortex. The flexible PDMS nerve channel can be implanted into the brain to target the visual thalamus. c: Biohybrid implant in which the PDMS channel has been replaced with a GelSH-GelNB hydrogel conduit. d: Schematic of the biohybrid implant. The microfluidic axon guidance structure is aligned on top of the Pt-based microelectrode array and seeded with neural spheroids. The implantable nerve channel is made of PDMS with an axon outlet at the end or consists of a GelSH-GelNB based hydrogel conduit vertically fabricated on top of the axon outlet. Neural spheroids are seeded into each of the 16 seeding wells to grow axons towards the nerve channel. e: The biohybrid implant is flipped around and implanted onto the cortical surface of a craniotomized mouse brain. The PDMS or hydrogel nerve channel is directed towards the lateral geniculate nucleus (LGN). f: The implant is fixed onto the mouse head using a glass window and dental cement. A headbar enables subsequent mounting on a 2-Photon <t>microscope</t> for imaging. During stimulation experiments the implant is connected through an omnetics connector.
Two Photon Microscopy Movable Objective Microscope, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/two-photon microscopy movable objective microscope/product/Sutter Instrument Company
Average 90 stars, based on 1 article reviews
two-photon microscopy movable objective microscope - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Sutter Instrument two-photon laser-scanning microscope
a: The implantable biohybrid nerve model with a PDMS based nerve channel. b: Magnification of the biohybrid axon guidance structure that is implanted on the cortex. The flexible PDMS nerve channel can be implanted into the brain to target the visual thalamus. c: Biohybrid implant in which the PDMS channel has been replaced with a GelSH-GelNB hydrogel conduit. d: Schematic of the biohybrid implant. The microfluidic axon guidance structure is aligned on top of the Pt-based microelectrode array and seeded with neural spheroids. The implantable nerve channel is made of PDMS with an axon outlet at the end or consists of a GelSH-GelNB based hydrogel conduit vertically fabricated on top of the axon outlet. Neural spheroids are seeded into each of the 16 seeding wells to grow axons towards the nerve channel. e: The biohybrid implant is flipped around and implanted onto the cortical surface of a craniotomized mouse brain. The PDMS or hydrogel nerve channel is directed towards the lateral geniculate nucleus (LGN). f: The implant is fixed onto the mouse head using a glass window and dental cement. A headbar enables subsequent mounting on a 2-Photon <t>microscope</t> for imaging. During stimulation experiments the implant is connected through an omnetics connector.
Two Photon Laser Scanning Microscope, supplied by Sutter Instrument, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/two-photon laser-scanning microscope/product/Sutter Instrument
Average 90 stars, based on 1 article reviews
two-photon laser-scanning microscope - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


a: The implantable biohybrid nerve model with a PDMS based nerve channel. b: Magnification of the biohybrid axon guidance structure that is implanted on the cortex. The flexible PDMS nerve channel can be implanted into the brain to target the visual thalamus. c: Biohybrid implant in which the PDMS channel has been replaced with a GelSH-GelNB hydrogel conduit. d: Schematic of the biohybrid implant. The microfluidic axon guidance structure is aligned on top of the Pt-based microelectrode array and seeded with neural spheroids. The implantable nerve channel is made of PDMS with an axon outlet at the end or consists of a GelSH-GelNB based hydrogel conduit vertically fabricated on top of the axon outlet. Neural spheroids are seeded into each of the 16 seeding wells to grow axons towards the nerve channel. e: The biohybrid implant is flipped around and implanted onto the cortical surface of a craniotomized mouse brain. The PDMS or hydrogel nerve channel is directed towards the lateral geniculate nucleus (LGN). f: The implant is fixed onto the mouse head using a glass window and dental cement. A headbar enables subsequent mounting on a 2-Photon microscope for imaging. During stimulation experiments the implant is connected through an omnetics connector.

Journal: bioRxiv

Article Title: An implantable biohybrid nerve model towards synaptic deep brain stimulation

doi: 10.1101/2024.05.31.596665

Figure Lengend Snippet: a: The implantable biohybrid nerve model with a PDMS based nerve channel. b: Magnification of the biohybrid axon guidance structure that is implanted on the cortex. The flexible PDMS nerve channel can be implanted into the brain to target the visual thalamus. c: Biohybrid implant in which the PDMS channel has been replaced with a GelSH-GelNB hydrogel conduit. d: Schematic of the biohybrid implant. The microfluidic axon guidance structure is aligned on top of the Pt-based microelectrode array and seeded with neural spheroids. The implantable nerve channel is made of PDMS with an axon outlet at the end or consists of a GelSH-GelNB based hydrogel conduit vertically fabricated on top of the axon outlet. Neural spheroids are seeded into each of the 16 seeding wells to grow axons towards the nerve channel. e: The biohybrid implant is flipped around and implanted onto the cortical surface of a craniotomized mouse brain. The PDMS or hydrogel nerve channel is directed towards the lateral geniculate nucleus (LGN). f: The implant is fixed onto the mouse head using a glass window and dental cement. A headbar enables subsequent mounting on a 2-Photon microscope for imaging. During stimulation experiments the implant is connected through an omnetics connector.

Article Snippet: Axon growth in the biohybrid implant was assessed in vivo using a two-photon microscope (FEMTOSmart series, Femtonics).

Techniques: Microelectrode Array, Microscopy, Imaging