two-photon imaging Search Results


90
TPLSM laboratories two-photon laser-scanning microscopy image stacks
Two Photon Laser Scanning Microscopy Image Stacks, supplied by TPLSM laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/two+photon+laser+scanning+microscopy+image+stacks/pmc07352754-85-6-5
Average 90 stars, based on 1 article reviews
two-photon laser-scanning microscopy image stacks - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Federation of European Neuroscience Societies two-photon imaging
Two Photon Imaging, supplied by Federation of European Neuroscience Societies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/two+photon+imaging/pm20180852-118-33-13
Average 90 stars, based on 1 article reviews
two-photon imaging - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Evident Corporation a custom-made video-rate two-photon imaging system
A Custom Made Video Rate Two Photon Imaging System, supplied by Evident Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/a+custom+made+video+rate+two+photon+imaging+system/pm20665696-82-17-23
Average 90 stars, based on 1 article reviews
a custom-made video-rate two-photon imaging system - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Thorlabs two-photon imaging system
Two Photon Imaging System, supplied by Thorlabs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/two+photon+imaging+system/bio_rxiv__2020__12__11__419887-104-0-3
Average 90 stars, based on 1 article reviews
two-photon imaging system - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Stryker two-photon imaging
Two Photon Imaging, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/two+photon+imaging/pm37279562-29-71-65
Average 90 stars, based on 1 article reviews
two-photon imaging - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
SourceForge net software for controlling the two-photon microscope and pre-processing of the calcium imaging data
Software For Controlling The Two Photon Microscope And Pre Processing Of The Calcium Imaging Data, supplied by SourceForge net, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/software+for+controlling+the+two+photon+microscope+and+pre+processing+of+the+calcium+imaging+data/pmc09803349-252-7-16
Average 90 stars, based on 1 article reviews
software for controlling the two-photon microscope and pre-processing of the calcium imaging data - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
TPLSM laboratories two-photon imaging of gcamp6s-expressing tc axons
Two Photon Imaging Of Gcamp6s Expressing Tc Axons, supplied by TPLSM laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/two+photon+imaging+of+gcamp6s+expressing+tc+axons/pm29844612-120-22-0
Average 90 stars, based on 1 article reviews
two-photon imaging of gcamp6s-expressing tc axons - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Photonics Inc two-dimensional nonlinear hyperspectral imaging
Two Dimensional Nonlinear Hyperspectral Imaging, supplied by Photonics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/two+dimensional+nonlinear+hyperspectral+imaging/10__1103_slash_physrevb__104__l241302-227-18-22
Average 90 stars, based on 1 article reviews
two-dimensional nonlinear hyperspectral imaging - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
SPECTRO Analytical two-photon spectro-temporal lifetime imaging by digitally sculpted excitation (slide) technique
Two Photon Spectro Temporal Lifetime Imaging By Digitally Sculpted Excitation (Slide) Technique, supplied by SPECTRO Analytical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/two+photon+spectro+temporal+lifetime+imaging+by+digitally+sculpted+excitation++slide++technique/us11009459-138-14-15
Average 90 stars, based on 1 article reviews
two-photon spectro-temporal lifetime imaging by digitally sculpted excitation (slide) technique - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
TPLSM laboratories two-photon laser scanning microscopy imaging of nadh fluorescence
(a) Schematic of the cortical surface. Excitation and detection cones are defined by objective NA. (b) Normalized emission spectra of <t>NADH</t> and SR101 (thick solid lines), transmission of emission filters in NADH and SR101 detection channels (dashed lines), and HbO and HbR molar extinction coefficients (thin solid lines).
Two Photon Laser Scanning Microscopy Imaging Of Nadh Fluorescence, supplied by TPLSM laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/two+photon+laser+scanning+microscopy+imaging+of+nadh+fluorescence/pmc03206923-34-40-37
Average 90 stars, based on 1 article reviews
two-photon laser scanning microscopy imaging of nadh fluorescence - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Vascular Dynamics two-photon imaging
(a) Schematic of the cortical surface. Excitation and detection cones are defined by objective NA. (b) Normalized emission spectra of <t>NADH</t> and SR101 (thick solid lines), transmission of emission filters in NADH and SR101 detection channels (dashed lines), and HbO and HbR molar extinction coefficients (thin solid lines).
Two Photon Imaging, supplied by Vascular Dynamics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/two+photon+imaging/pmc09941497__41467_2023_36643_MOESM2_ESM-396-23-33
Average 90 stars, based on 1 article reviews
two-photon imaging - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Scientifica two-photon galvo-resonant scanning imaging system hyperscope
(a) Schematic of the cortical surface. Excitation and detection cones are defined by objective NA. (b) Normalized emission spectra of <t>NADH</t> and SR101 (thick solid lines), transmission of emission filters in NADH and SR101 detection channels (dashed lines), and HbO and HbR molar extinction coefficients (thin solid lines).
Two Photon Galvo Resonant Scanning Imaging System Hyperscope, supplied by Scientifica, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/two-photon+imaging/two+photon+galvo+resonant+scanning+imaging+system+hyperscope/pmc11992252-332-17-23
Average 90 stars, based on 1 article reviews
two-photon galvo-resonant scanning imaging system hyperscope - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


(a) Schematic of the cortical surface. Excitation and detection cones are defined by objective NA. (b) Normalized emission spectra of NADH and SR101 (thick solid lines), transmission of emission filters in NADH and SR101 detection channels (dashed lines), and HbO and HbR molar extinction coefficients (thin solid lines).

Journal: Journal of Biomedical Optics

Article Title: Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response

doi: 10.1117/1.3633339

Figure Lengend Snippet: (a) Schematic of the cortical surface. Excitation and detection cones are defined by objective NA. (b) Normalized emission spectra of NADH and SR101 (thick solid lines), transmission of emission filters in NADH and SR101 detection channels (dashed lines), and HbO and HbR molar extinction coefficients (thin solid lines).

Article Snippet: 2 , 3 In addition to linear excitation of NADH fluorescence, a relatively small but sufficient two-photon absorption cross section exists in the near-infrared spectrum from 700 to 750 nm, 4 which allows two-photon laser scanning microscopy (TPLSM) imaging of NADH fluorescence.

Techniques: Transmission Assay

Comparison of the ray-tracing algorithm with the experimental data. (a) Maximum intensity projection (MIP) of a 400-μm-thick microvascular stack labeled with FITC in rat primary somatosensory cortex. (b) MIP of the 110-μm-thick reconstructed microvasculature obtained from (a) using microvascular graphing. Vessel diameters were presented with different shades of gray. (c, e) TPLSM images of NADH and SR101 fluorescence intensities at a depth of 110 μm. Scale bars are 100 μm. (d, f) Fluorescence intensity profiles (black dots) along the white dotted lines from (c) and (e), respectively. Solid lines represent the results of the full ray-tracing algorithms (fluorescence excitation and emission detection), while dashed lines represent ray-tracing results based on blood absorption of emission detection only.

Journal: Journal of Biomedical Optics

Article Title: Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response

doi: 10.1117/1.3633339

Figure Lengend Snippet: Comparison of the ray-tracing algorithm with the experimental data. (a) Maximum intensity projection (MIP) of a 400-μm-thick microvascular stack labeled with FITC in rat primary somatosensory cortex. (b) MIP of the 110-μm-thick reconstructed microvasculature obtained from (a) using microvascular graphing. Vessel diameters were presented with different shades of gray. (c, e) TPLSM images of NADH and SR101 fluorescence intensities at a depth of 110 μm. Scale bars are 100 μm. (d, f) Fluorescence intensity profiles (black dots) along the white dotted lines from (c) and (e), respectively. Solid lines represent the results of the full ray-tracing algorithms (fluorescence excitation and emission detection), while dashed lines represent ray-tracing results based on blood absorption of emission detection only.

Article Snippet: 2 , 3 In addition to linear excitation of NADH fluorescence, a relatively small but sufficient two-photon absorption cross section exists in the near-infrared spectrum from 700 to 750 nm, 4 which allows two-photon laser scanning microscopy (TPLSM) imaging of NADH fluorescence.

Techniques: Comparison, Labeling, Fluorescence

Dependence of detected relative NADH fluorescence intensity on microvascular structure and imaging parameters. (a–c) Relative NADH fluorescence intensity dependence on vessel diameter (5–80 μm) and lateral distance at imaging depths of 20, 50, and 100 μm, respectively. (d, e) summarize the information presented in (a–c). Contour lines represent 50 and 90% intensity levels. (f) Influence of objective NA on detected relative NADH signal in the presence of the pial vessel with 50-μm diameter at three imaging depths (20, 50, and 100 μm).

Journal: Journal of Biomedical Optics

Article Title: Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response

doi: 10.1117/1.3633339

Figure Lengend Snippet: Dependence of detected relative NADH fluorescence intensity on microvascular structure and imaging parameters. (a–c) Relative NADH fluorescence intensity dependence on vessel diameter (5–80 μm) and lateral distance at imaging depths of 20, 50, and 100 μm, respectively. (d, e) summarize the information presented in (a–c). Contour lines represent 50 and 90% intensity levels. (f) Influence of objective NA on detected relative NADH signal in the presence of the pial vessel with 50-μm diameter at three imaging depths (20, 50, and 100 μm).

Article Snippet: 2 , 3 In addition to linear excitation of NADH fluorescence, a relatively small but sufficient two-photon absorption cross section exists in the near-infrared spectrum from 700 to 750 nm, 4 which allows two-photon laser scanning microscopy (TPLSM) imaging of NADH fluorescence.

Techniques: Fluorescence, Imaging

Influence of blood volume and hemoglobin oxygen saturation changes on the detected NADH fluorescence intensity given no changes in NADH concentration. (a–c) Influence of ±20% changes in HbT on the NADH signal. (d–f) Influence of SO2 changes on the NADH signal. The relative changes in the NADH signal in (d–f) were calculated with respect to SO2 = 75%. Contour lines represent ±0.1, ±1, and ±10% changes in detected NADH fluorescence intensity as a function of lateral distance, relative HbT (rHbT), SO2, pial vessel diameter (10, 20, and 50 μm) and imaging depth (20, 50, and 100 μm).

Journal: Journal of Biomedical Optics

Article Title: Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response

doi: 10.1117/1.3633339

Figure Lengend Snippet: Influence of blood volume and hemoglobin oxygen saturation changes on the detected NADH fluorescence intensity given no changes in NADH concentration. (a–c) Influence of ±20% changes in HbT on the NADH signal. (d–f) Influence of SO2 changes on the NADH signal. The relative changes in the NADH signal in (d–f) were calculated with respect to SO2 = 75%. Contour lines represent ±0.1, ±1, and ±10% changes in detected NADH fluorescence intensity as a function of lateral distance, relative HbT (rHbT), SO2, pial vessel diameter (10, 20, and 50 μm) and imaging depth (20, 50, and 100 μm).

Article Snippet: 2 , 3 In addition to linear excitation of NADH fluorescence, a relatively small but sufficient two-photon absorption cross section exists in the near-infrared spectrum from 700 to 750 nm, 4 which allows two-photon laser scanning microscopy (TPLSM) imaging of NADH fluorescence.

Techniques: Fluorescence, Concentration Assay, Imaging

Influence of blood volume changes on the detected NADH fluorescence intensity assuming a true +2% change in NADH fluorescence. (a–i) show the relative error of the detected change in NADH fluorescence intensity (ΔNADH/NADH0) given a ±20% range of change in HbT, different vessel diameters (10, 20, and 50 μm), and imaging depths (20, 50, and 100 μm) as a function of lateral distance. Contours show the relative NADH error of ±1, ±10, and ±100%. Shaded regions signify the importance of a ⩽−100% detection error, where measurements affected by the HbT changes show the opposite sign from the true NADH fluorescence changes.

Journal: Journal of Biomedical Optics

Article Title: Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response

doi: 10.1117/1.3633339

Figure Lengend Snippet: Influence of blood volume changes on the detected NADH fluorescence intensity assuming a true +2% change in NADH fluorescence. (a–i) show the relative error of the detected change in NADH fluorescence intensity (ΔNADH/NADH0) given a ±20% range of change in HbT, different vessel diameters (10, 20, and 50 μm), and imaging depths (20, 50, and 100 μm) as a function of lateral distance. Contours show the relative NADH error of ±1, ±10, and ±100%. Shaded regions signify the importance of a ⩽−100% detection error, where measurements affected by the HbT changes show the opposite sign from the true NADH fluorescence changes.

Article Snippet: 2 , 3 In addition to linear excitation of NADH fluorescence, a relatively small but sufficient two-photon absorption cross section exists in the near-infrared spectrum from 700 to 750 nm, 4 which allows two-photon laser scanning microscopy (TPLSM) imaging of NADH fluorescence.

Techniques: Fluorescence, Imaging

Correction procedure applied to the detected NADH fluorescence intensity changes during mild hypoxia and hyperoxia. (a–c) Mild hypoxia with FiO2 = 16.8%. (a, b) NADH and SR101 fluorescence intensities, respectively, 55 μm below cortical surface. (c) Temporal profiles of relative noncorrected NADH and SR101 fluorescence intensity changes from the ROIs outlined by white lines in (a) and the corresponding corrected NADH signal obtained by using simple correction procedure with K = 1.15. An initial ∼3 min. of normoxia (FiO2 = 21%) was followed by 7 min. of mild hypoxia (FiO2 = 16.8%). The hypoxic period is marked by the black bar in (c). (d–f) Mild hypoxia with FiO2 = 14.7%, 50 μm below cortical surface. (g–i) Hyperoxia with FiO2 = 100%, 70 μm below cortical surface. Scale bar: 100 μm.

Journal: Journal of Biomedical Optics

Article Title: Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response

doi: 10.1117/1.3633339

Figure Lengend Snippet: Correction procedure applied to the detected NADH fluorescence intensity changes during mild hypoxia and hyperoxia. (a–c) Mild hypoxia with FiO2 = 16.8%. (a, b) NADH and SR101 fluorescence intensities, respectively, 55 μm below cortical surface. (c) Temporal profiles of relative noncorrected NADH and SR101 fluorescence intensity changes from the ROIs outlined by white lines in (a) and the corresponding corrected NADH signal obtained by using simple correction procedure with K = 1.15. An initial ∼3 min. of normoxia (FiO2 = 21%) was followed by 7 min. of mild hypoxia (FiO2 = 16.8%). The hypoxic period is marked by the black bar in (c). (d–f) Mild hypoxia with FiO2 = 14.7%, 50 μm below cortical surface. (g–i) Hyperoxia with FiO2 = 100%, 70 μm below cortical surface. Scale bar: 100 μm.

Article Snippet: 2 , 3 In addition to linear excitation of NADH fluorescence, a relatively small but sufficient two-photon absorption cross section exists in the near-infrared spectrum from 700 to 750 nm, 4 which allows two-photon laser scanning microscopy (TPLSM) imaging of NADH fluorescence.

Techniques: Fluorescence

Influence of blood volume changes on the detected NADH fluorescence intensity using our correction procedure given a +2% true change in NADH fluorescence. (a–i) show the relative error of the corrected change in NADH fluorescence intensity (ΔNADH/NADH0) given a ±20% range of change in HbT, different vessel diameters (10, 20, and 50 μm) and imaging depths (20, 50, and 100 μm) as a function of lateral distance. Contours show the relative NADH error of ±1, ±10, and ±100%. Shaded regions signify the importance of a ⩽−100% detection error, where measurements affected by the HbT changes show the opposite sign from the true NADH fluorescence changes. The value of the correction factor was 1.15.

Journal: Journal of Biomedical Optics

Article Title: Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response

doi: 10.1117/1.3633339

Figure Lengend Snippet: Influence of blood volume changes on the detected NADH fluorescence intensity using our correction procedure given a +2% true change in NADH fluorescence. (a–i) show the relative error of the corrected change in NADH fluorescence intensity (ΔNADH/NADH0) given a ±20% range of change in HbT, different vessel diameters (10, 20, and 50 μm) and imaging depths (20, 50, and 100 μm) as a function of lateral distance. Contours show the relative NADH error of ±1, ±10, and ±100%. Shaded regions signify the importance of a ⩽−100% detection error, where measurements affected by the HbT changes show the opposite sign from the true NADH fluorescence changes. The value of the correction factor was 1.15.

Article Snippet: 2 , 3 In addition to linear excitation of NADH fluorescence, a relatively small but sufficient two-photon absorption cross section exists in the near-infrared spectrum from 700 to 750 nm, 4 which allows two-photon laser scanning microscopy (TPLSM) imaging of NADH fluorescence.

Techniques: Fluorescence, Imaging

NADH fluorescence emission intensity change during respiratory arrest. (a) Maximum intensity projection of a 200-μm-thick microvascular stack labeled with FITC in rat SI cortex. (b) NADH fluorescence intensity map 100 μm below cortical surface. Scale bar: 100 μm. (c) Temporal profile of relative NADH fluorescence intensity changes from the ROI outlined by black line in (b). An initial 95 s of normal breathing (FiO2 = 21%) was followed by 70 s of respiratory arrest and subsequent return to normal breathing. The respiratory arrest period is marked by the black bar in (c).

Journal: Journal of Biomedical Optics

Article Title: Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response

doi: 10.1117/1.3633339

Figure Lengend Snippet: NADH fluorescence emission intensity change during respiratory arrest. (a) Maximum intensity projection of a 200-μm-thick microvascular stack labeled with FITC in rat SI cortex. (b) NADH fluorescence intensity map 100 μm below cortical surface. Scale bar: 100 μm. (c) Temporal profile of relative NADH fluorescence intensity changes from the ROI outlined by black line in (b). An initial 95 s of normal breathing (FiO2 = 21%) was followed by 70 s of respiratory arrest and subsequent return to normal breathing. The respiratory arrest period is marked by the black bar in (c).

Article Snippet: 2 , 3 In addition to linear excitation of NADH fluorescence, a relatively small but sufficient two-photon absorption cross section exists in the near-infrared spectrum from 700 to 750 nm, 4 which allows two-photon laser scanning microscopy (TPLSM) imaging of NADH fluorescence.

Techniques: Fluorescence, Labeling