|
HEKA Instruments Inc
pico-ampere sensitivity patch clamp amplifier heka epc 10 usb Pico Ampere Sensitivity Patch Clamp Amplifier Heka Epc 10 Usb, supplied by HEKA Instruments Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/pico+patch-clamp+amplifier/epc+10+amplifier/10__1021_slash_acs__jpcc__2c02650____jp2c02650_si_001-20-21-30 Average 90 stars, based on 1 article reviews
pico-ampere sensitivity patch clamp amplifier heka epc 10 usb - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Molecular Devices LLC
axopatch 200b axon instruments patch clamp amplifiers Axopatch 200b Axon Instruments Patch Clamp Amplifiers, supplied by Molecular Devices LLC, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/pico+patch-clamp+amplifier/Axon+Instruments+Patch-Clamp+Amplifiers/pmc04114450-39-14-16 Average 96 stars, based on 1 article reviews
axopatch 200b axon instruments patch clamp amplifiers - by Bioz Stars,
2026-11
96/100 stars
|
Buy from Supplier |
|
Molecular Devices LLC
patch clamp amplifier Patch Clamp Amplifier, supplied by Molecular Devices LLC, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/pico+patch-clamp+amplifier/Axopatch+200B-2+capacitor+feedback+patch+clamp+amplifier/pmc02519144-47-24-26 Average 97 stars, based on 1 article reviews
patch clamp amplifier - by Bioz Stars,
2026-11
97/100 stars
|
Buy from Supplier |
|
AutoMate Scientific Inc
axopatch amplifier Axopatch Amplifier, supplied by AutoMate Scientific Inc, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/pico+patch-clamp+amplifier/Axopatch+Amplifier/custom%40axopatch_200b_2%4042272273 Average 97 stars, based on 1 article reviews
axopatch amplifier - by Bioz Stars,
2026-11
97/100 stars
|
Buy from Supplier |
|
A-M Systems
2400 amplifier 2400 Amplifier, supplied by A-M Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/pico+patch-clamp+amplifier/2400+amplifier/pm25416596-76-6-10 Average 90 stars, based on 1 article reviews
2400 amplifier - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Nanosurf Inc
afm head nanosurf flex-bio Afm Head Nanosurf Flex Bio, supplied by Nanosurf Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/pico+patch-clamp+amplifier/easyscan+2/pm38355286-145-2-4 Average 90 stars, based on 1 article reviews
afm head nanosurf flex-bio - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Cytosurge ag
fluidfm microscope Fluidfm Microscope, supplied by Cytosurge ag, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/pico+patch-clamp+amplifier/fluidfm+microscope/10__1063_slash_1__5053879-49-3-5 Average 90 stars, based on 1 article reviews
fluidfm microscope - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Molecular Devices LLC
dcf ![]() Dcf, supplied by Molecular Devices LLC, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/pico+patch-clamp+amplifier/MultiClamp+Amplifier/pmc07724199-40-11-68 Average 99 stars, based on 1 article reviews
dcf - by Bioz Stars,
2026-11
99/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Redox Biology
Article Title: In situ labeling of non-accommodating interneurons based on metabolic rates
doi: 10.1016/j.redox.2020.101798
Figure Lengend Snippet: Comparison of DCF positive cells and interneurons in the hippocampus (A - C. Green and blue borders outline results from DCF + WT (left) and VGAT-YFP (right) organotypic hippocampal slice cultures.) A. DCF fluorescence pattern in a hippocampal slice culture from a wild type (WT) wistar rat at different magnifications. (Aa.) reconstruction of the whole hippocampus with individual regions delineated (Ab.) CA3 stratum pyramidale and (Ac.) close up of individual cells displaying the morphological characteristics of interneurons. B. Distribution of fluorescent interneurons in slice culture from VGAT-YFP rats. (Ba.) reconstruction of the whole hippocampus (Bb.) CA3 stratum pyramidale (Bc.), close up of individual cells in the CA3. C. Exemplary traces of fast-spiking non-accommodating and accommodating firing patterns upon a 1 s depolarization step from (Ca.) WT DCF positive cells and (Cb.) VGAT-YFP interneurons. D. Exemplary AP traces from DCF + WT (green) and VGAT-YFP (blue) cultures with comparison of non-accomodating (pale red outline, left) and accommodating (grey outline, right) interneurons as classified by binary logistic regression. E. Distribution of the two firing patterns among VGAT-YFP and DCF + cells. While both phenotypes were equally represented in YFP-interneurons, 88% of the DCF + cells were predicted to be fast-spiking, non-accommodating by logistic regression analysis. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Article Snippet: Whole cell recordings were obtained from fluorescent cells in VGAT-YFP or
Techniques: Fluorescence
Journal: Redox Biology
Article Title: In situ labeling of non-accommodating interneurons based on metabolic rates
doi: 10.1016/j.redox.2020.101798
Figure Lengend Snippet: Parvalbumin expression in DCF + cells A. Parvalbumin expression was identified by immunofluorescence (red) in biocytin-filled (green) DCF + neurons following whole cell recordings. (Aa.) DCF + cells in the CA3 region of a slice culture. The recorded Biocytin-filled cell is marked by an asterisk. The image on the left represents the DCF labeling used to select a cell for recording. The picture on the right shows the same slice and region after immunohistochemistry for PV. The Biocytin-filled recorded cell is PV -. Noticeably, its neighbour (yellow arrow, no electrophysiology) is both DCF + and PV +. The electrophysiology traces on the left show a magnification of the first and last 100 ms of an AP trace upon a 1 s depolarizing pulse. Note the absence of accommodation. (Ab.) Another example of immunohistochemistry and firing pattern of a DCF + cell upon a 1 s depolarizing pulse with comparison of the first and last 100 ms showing spike frequency facilitation. While the recorded cell was both PV and DCF +, the surrounding PV + cells also present a faint CM-DCF fluorescence (Ac.) 53% of the recorded DCF + cells were also PV +. While nearly all cells were non-accommodating interneurons, the PV + cells had significantly narrower APs ( p = 0.004), higher maximum firing rates ( p = 0.027), and displayed frequency facilitation ( p = 0.045, Mann-Whitney U test). Ba. Overlay of in situ DCF fluorescence and immunofluorescent PV-labeling of the same slice culture (left) and a close up of the CA3 region (right). (Bb.) Interneuron counting following the full reconstruction of four slice cultures revealed that 96% of the PV + FS interneurons were also DCF +. Ca. DCF staining (green) in acute slices from tdTomato parv-Cre transgenic mice. PV + fast spiking cells (red) were also DCF +, but not all DCF + cells were PV + (the images show excerpts from the DG, hilus and CA3) Cb. In acute slices from young adult Wistar rats, DCF accumulated exclusively in interneurons consisting of fast-spiking non-accommodating and intermediate accommodating neurons. The insert shows the DIC and fluorescent image of the recorded cell, while the traces demonstrate the fast spiking pattern and frequency facilitation between the first and last 100 ms of the depolarization step. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Article Snippet: Whole cell recordings were obtained from fluorescent cells in VGAT-YFP or
Techniques: Expressing, Immunofluorescence, Labeling, Immunohistochemistry, Fluorescence, MANN-WHITNEY, In Situ, Staining, Transgenic Assay