microfluidic bbb Search Results


90
MicroFluidic Systems 3d bbb models
3d Bbb Models, supplied by MicroFluidic Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+bbb/3d+bbb+models/pm37003488-258-5-11
Average 90 stars, based on 1 article reviews
3d bbb models - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
MicroFluidic Systems synthetic microvasculature of the blood–brain barrier (sym-bbb)
Synthetic Microvasculature Of The Blood–Brain Barrier (Sym Bbb), supplied by MicroFluidic Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+bbb/synthetic+microvasculature+of+the+blood+brain+barrier++sym+bbb+/pm37237588-452-21-13
Average 90 stars, based on 1 article reviews
synthetic microvasculature of the blood–brain barrier (sym-bbb) - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
SynVivo Inc bbb microfluidic chip
a Schematic of SynVivo <t>BBB</t> <t>microfluidic</t> chip: ( 1 ) inlet port where media with or without tracer is flowed through the outer compartment to change media for HUVECs. ( 2 ) Outer compartment, containing HUVECs. ( 3 ) 3 μm pores, to allow diffusion of media and tracer between the central and outer compartments. ( 4 ) Central compartment, containing astrocytes or cancer cells. ( 5 ) Outlet port where perfusate from the outer compartment is collected. ( 6 ) Inlet port for central compartment, used to seed and change media for the astrocytes/cancer cells in the central compartment. ( 7 ) Output ports where perfusate from the central compartment is collected. b Morphology of astrocytes in the central compartment and HUVECs in the outer compartment without the addition of flow ( c ) morphology of astrocytes in the central compartment and HUVECs in the outer compartment with the addition of flow. d Representation of where the regions of interest (ROI) measurements are taken for data analysis. White rectangle scale bars 500 μm
Bbb Microfluidic Chip, supplied by SynVivo Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+bbb/bbb+microfluidic+chip/pmc05260004-81-6-5
Average 90 stars, based on 1 article reviews
bbb microfluidic chip - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
SynVivo Inc 3d bbb microfluidic models
a Schematic of SynVivo <t>BBB</t> <t>microfluidic</t> chip: ( 1 ) inlet port where media with or without tracer is flowed through the outer compartment to change media for HUVECs. ( 2 ) Outer compartment, containing HUVECs. ( 3 ) 3 μm pores, to allow diffusion of media and tracer between the central and outer compartments. ( 4 ) Central compartment, containing astrocytes or cancer cells. ( 5 ) Outlet port where perfusate from the outer compartment is collected. ( 6 ) Inlet port for central compartment, used to seed and change media for the astrocytes/cancer cells in the central compartment. ( 7 ) Output ports where perfusate from the central compartment is collected. b Morphology of astrocytes in the central compartment and HUVECs in the outer compartment without the addition of flow ( c ) morphology of astrocytes in the central compartment and HUVECs in the outer compartment with the addition of flow. d Representation of where the regions of interest (ROI) measurements are taken for data analysis. White rectangle scale bars 500 μm
3d Bbb Microfluidic Models, supplied by SynVivo Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+bbb/3d+bbb+microfluidic+models/pm34313388-42-1-9
Average 90 stars, based on 1 article reviews
3d bbb microfluidic models - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
STEMCELL Technologies Inc microfluidic bbb mps model
a Schematic of SynVivo <t>BBB</t> <t>microfluidic</t> chip: ( 1 ) inlet port where media with or without tracer is flowed through the outer compartment to change media for HUVECs. ( 2 ) Outer compartment, containing HUVECs. ( 3 ) 3 μm pores, to allow diffusion of media and tracer between the central and outer compartments. ( 4 ) Central compartment, containing astrocytes or cancer cells. ( 5 ) Outlet port where perfusate from the outer compartment is collected. ( 6 ) Inlet port for central compartment, used to seed and change media for the astrocytes/cancer cells in the central compartment. ( 7 ) Output ports where perfusate from the central compartment is collected. b Morphology of astrocytes in the central compartment and HUVECs in the outer compartment without the addition of flow ( c ) morphology of astrocytes in the central compartment and HUVECs in the outer compartment with the addition of flow. d Representation of where the regions of interest (ROI) measurements are taken for data analysis. White rectangle scale bars 500 μm
Microfluidic Bbb Mps Model, supplied by STEMCELL Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+bbb/microfluidic+bbb+mps+model/pm37068137-35-14-7
Average 90 stars, based on 1 article reviews
microfluidic bbb mps model - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

86
Nanotherapeutics microfluidic human bbb
a Schematic of SynVivo <t>BBB</t> <t>microfluidic</t> chip: ( 1 ) inlet port where media with or without tracer is flowed through the outer compartment to change media for HUVECs. ( 2 ) Outer compartment, containing HUVECs. ( 3 ) 3 μm pores, to allow diffusion of media and tracer between the central and outer compartments. ( 4 ) Central compartment, containing astrocytes or cancer cells. ( 5 ) Outlet port where perfusate from the outer compartment is collected. ( 6 ) Inlet port for central compartment, used to seed and change media for the astrocytes/cancer cells in the central compartment. ( 7 ) Output ports where perfusate from the central compartment is collected. b Morphology of astrocytes in the central compartment and HUVECs in the outer compartment without the addition of flow ( c ) morphology of astrocytes in the central compartment and HUVECs in the outer compartment with the addition of flow. d Representation of where the regions of interest (ROI) measurements are taken for data analysis. White rectangle scale bars 500 μm
Microfluidic Human Bbb, supplied by Nanotherapeutics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+bbb/bbb+chip+human+microfluidic+on/pmc13113825-47-7-18
Average 86 stars, based on 1 article reviews
microfluidic human bbb - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

Image Search Results


a Schematic of SynVivo BBB microfluidic chip: ( 1 ) inlet port where media with or without tracer is flowed through the outer compartment to change media for HUVECs. ( 2 ) Outer compartment, containing HUVECs. ( 3 ) 3 μm pores, to allow diffusion of media and tracer between the central and outer compartments. ( 4 ) Central compartment, containing astrocytes or cancer cells. ( 5 ) Outlet port where perfusate from the outer compartment is collected. ( 6 ) Inlet port for central compartment, used to seed and change media for the astrocytes/cancer cells in the central compartment. ( 7 ) Output ports where perfusate from the central compartment is collected. b Morphology of astrocytes in the central compartment and HUVECs in the outer compartment without the addition of flow ( c ) morphology of astrocytes in the central compartment and HUVECs in the outer compartment with the addition of flow. d Representation of where the regions of interest (ROI) measurements are taken for data analysis. White rectangle scale bars 500 μm

Journal: Fluids and Barriers of the CNS

Article Title: Permeability across a novel microfluidic blood-tumor barrier model

doi: 10.1186/s12987-017-0050-9

Figure Lengend Snippet: a Schematic of SynVivo BBB microfluidic chip: ( 1 ) inlet port where media with or without tracer is flowed through the outer compartment to change media for HUVECs. ( 2 ) Outer compartment, containing HUVECs. ( 3 ) 3 μm pores, to allow diffusion of media and tracer between the central and outer compartments. ( 4 ) Central compartment, containing astrocytes or cancer cells. ( 5 ) Outlet port where perfusate from the outer compartment is collected. ( 6 ) Inlet port for central compartment, used to seed and change media for the astrocytes/cancer cells in the central compartment. ( 7 ) Output ports where perfusate from the central compartment is collected. b Morphology of astrocytes in the central compartment and HUVECs in the outer compartment without the addition of flow ( c ) morphology of astrocytes in the central compartment and HUVECs in the outer compartment with the addition of flow. d Representation of where the regions of interest (ROI) measurements are taken for data analysis. White rectangle scale bars 500 μm

Article Snippet: Fig. 1 a Schematic of SynVivo BBB microfluidic chip: ( ) inlet port where media with or without tracer is flowed through the outer compartment to change media for HUVECs. ( ) Outer compartment, containing HUVECs. ( 3 ) 3 μm pores, to allow diffusion of media and tracer between the central and outer compartments. ( 4 ) Central compartment, containing astrocytes or cancer cells. ( 5 ) Outlet port where perfusate from the outer compartment is collected. ( 6 ) Inlet port for central compartment, used to seed and change media for the astrocytes/cancer cells in the central compartment. ( 7 ) Output ports where perfusate from the central compartment is collected. b Morphology of astrocytes in the central compartment and HUVECs in the outer compartment without the addition of flow ( c ) morphology of astrocytes in the central compartment and HUVECs in the outer compartment with the addition of flow. d Representation of where the regions of interest (ROI) measurements are taken for data analysis.

Techniques: Diffusion-based Assay

The diffusion rates of free MW tracers <1000 Da, 3–5 kDa and >60 kDa in an unrestricted, cell free microfluidic chips are shown. Statistical significance was determined using one-way ANOVA followed by Tukey’s multiple comparison tests, and student’s t test; n = 3–6 chips. All data represent mean ± SEM

Journal: Fluids and Barriers of the CNS

Article Title: Permeability across a novel microfluidic blood-tumor barrier model

doi: 10.1186/s12987-017-0050-9

Figure Lengend Snippet: The diffusion rates of free MW tracers <1000 Da, 3–5 kDa and >60 kDa in an unrestricted, cell free microfluidic chips are shown. Statistical significance was determined using one-way ANOVA followed by Tukey’s multiple comparison tests, and student’s t test; n = 3–6 chips. All data represent mean ± SEM

Article Snippet: Fig. 1 a Schematic of SynVivo BBB microfluidic chip: ( ) inlet port where media with or without tracer is flowed through the outer compartment to change media for HUVECs. ( ) Outer compartment, containing HUVECs. ( 3 ) 3 μm pores, to allow diffusion of media and tracer between the central and outer compartments. ( 4 ) Central compartment, containing astrocytes or cancer cells. ( 5 ) Outlet port where perfusate from the outer compartment is collected. ( 6 ) Inlet port for central compartment, used to seed and change media for the astrocytes/cancer cells in the central compartment. ( 7 ) Output ports where perfusate from the central compartment is collected. b Morphology of astrocytes in the central compartment and HUVECs in the outer compartment without the addition of flow ( c ) morphology of astrocytes in the central compartment and HUVECs in the outer compartment with the addition of flow. d Representation of where the regions of interest (ROI) measurements are taken for data analysis.

Techniques: Diffusion-based Assay