mass cytometry data Search Results


90
Mendeley Ltd time-of-flight (cytof) mass cytometry data
Time Of Flight (Cytof) Mass Cytometry Data, supplied by Mendeley Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mass+cytometry+data/time+of+flight++cytof++mass+cytometry+data/pmc10597634-107-0-9
Average 90 stars, based on 1 article reviews
time-of-flight (cytof) mass cytometry data - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Purdue University Cytometry mass spectral data
Mass Spectral Data, supplied by Purdue University Cytometry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mass+cytometry+data/mass+spectral+data/pmc07511990-374-36-33
Average 90 stars, based on 1 article reviews
mass spectral data - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Mendeley Ltd mass cytometry data
Schematic of method for characterization of primary prostate cancer tissue using mass <t>cytometry</t> (A) The patient cohort consisted of 58 primary prostate cancer cases. For 16 patients, tumor and adjacent benign prostatic tissue (ABPT) samples were available. The remaining samples were from randomly selected regions from a prostatectomy without tumor assessment. Samples were analyzed by mass cytometry, and data were analyzed using Franken. (B) Markers used to categorize prostate epithelial cells as luminal, basal, or transitional, and markers used to identify tumor cells, cells from the microenvironment, and functional features, such as proliferation, apoptosis, or hypoxia.
Mass Cytometry Data, supplied by Mendeley Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mass+cytometry+data/mass+cytometry+data/pmc09044103-75-0-4
Average 90 stars, based on 1 article reviews
mass cytometry data - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Galbraith Laboratories Inc htp mass cytometry data

Htp Mass Cytometry Data, supplied by Galbraith Laboratories Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mass+cytometry+data/htp+mass+cytometry+data/pmc11479675-68-0-5
Average 90 stars, based on 1 article reviews
htp mass cytometry data - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
AllCells LLC mass cytometry data

Mass Cytometry Data, supplied by AllCells LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mass+cytometry+data/mass+cytometry+data/pmc04076922-422-0-14
Average 90 stars, based on 1 article reviews
mass cytometry data - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Purdue University Cytometry atlas of mass spectral data

Atlas Of Mass Spectral Data, supplied by Purdue University Cytometry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mass+cytometry+data/atlas+of+mass+spectral+data/10__1021_slash_ac60269a831-0-0-29
Average 90 stars, based on 1 article reviews
atlas of mass spectral data - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Verity Software House automated data cleanup for mass cytometry house

Automated Data Cleanup For Mass Cytometry House, supplied by Verity Software House, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mass+cytometry+data/automated+data+cleanup+for+mass+cytometry+house/pm31737997-1222-16-14
Average 90 stars, based on 1 article reviews
automated data cleanup for mass cytometry house - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Purdue University Cytometry archives of mass spectra data

Archives Of Mass Spectra Data, supplied by Purdue University Cytometry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mass+cytometry+data/archives+of+mass+spectra+data/10__1021_slash_ac60258a785-20-10-40
Average 90 stars, based on 1 article reviews
archives of mass spectra data - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

86
Purdue University Cytometry high resolution mass spectra

High Resolution Mass Spectra, supplied by Purdue University Cytometry, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/mass+cytometry+data/data+mass+resolution+spectroscopy/pm33998802__nn1c02414_si_001-168-0-7
Average 86 stars, based on 1 article reviews
high resolution mass spectra - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


Schematic of method for characterization of primary prostate cancer tissue using mass cytometry (A) The patient cohort consisted of 58 primary prostate cancer cases. For 16 patients, tumor and adjacent benign prostatic tissue (ABPT) samples were available. The remaining samples were from randomly selected regions from a prostatectomy without tumor assessment. Samples were analyzed by mass cytometry, and data were analyzed using Franken. (B) Markers used to categorize prostate epithelial cells as luminal, basal, or transitional, and markers used to identify tumor cells, cells from the microenvironment, and functional features, such as proliferation, apoptosis, or hypoxia.

Journal: Cell Reports Medicine

Article Title: Single-cell proteomics defines the cellular heterogeneity of localized prostate cancer

doi: 10.1016/j.xcrm.2022.100604

Figure Lengend Snippet: Schematic of method for characterization of primary prostate cancer tissue using mass cytometry (A) The patient cohort consisted of 58 primary prostate cancer cases. For 16 patients, tumor and adjacent benign prostatic tissue (ABPT) samples were available. The remaining samples were from randomly selected regions from a prostatectomy without tumor assessment. Samples were analyzed by mass cytometry, and data were analyzed using Franken. (B) Markers used to categorize prostate epithelial cells as luminal, basal, or transitional, and markers used to identify tumor cells, cells from the microenvironment, and functional features, such as proliferation, apoptosis, or hypoxia.

Article Snippet: Mass cytometry data , Mendeley , https://doi.org/10.17632/5k5xfj 626k.1.

Techniques: Mass Cytometry, Functional Assay

Stratification of samples reveals prostate tissue changes associated with tumor and advanced disease (A) UMAP of 23,200 cells (400 per patient) colored by expression of indicated marker. (B) Representative tissue sample stained for CD3 from a tissue microarray generated from prostate samples from the same cohort analyzed by mass cytometry. (C) Densities of T cells as determined by CD3 staining (p = 0.042). (D) Representative tissue sample stained for CD15 from a tissue microarray generated from prostate samples from the same cohort analyzed by mass cytometry. (E) Densities of granulocytes as determined by CD15 staining (p = 0.058). Scale bar, 50 μm. (F) Proportion of T cell metaclusters in ABPT and tumor samples across patients with paired samples (p = 0.066, 0.169, 0.023, 0.002, and 0.332 for TC01–05, respectively). N = 17. (G) Summary table of clusters that were significant when comparing ABPT and tumor samples (N = 17 for both groups). Metaclusters enriched in ABPT are colored in blue, while those enriched in tumor samples are colored in red. Comparison between intermediate- and high-grade patient samples (for combined tumor/ABPT; intermediate N = 46 and high grade N = 12). Metaclusters enriched in patients with high-grade disease are colored in dark red. Only significant relationships are colored, and remaining comparisons are shown in gray. (H) Proportion of macrophage metaclusters in ABPT and tumor samples across patients with paired samples (p = 0.095, 0.169, 0.515, 0.0004, and 0.014 for MA01–05, respectively). N = 17. In panels (F) and (H), dots are colored by disease severity (intermediate versus high grade). In all boxplots, boxes illustrate the IQR (25th to 75th percentile), the median is shown as the middle band, and the whiskers extend to 1.5 times the IQR from the top (or bottom) of the box to the furthest datum within that distance. Statistical testing between dependent paired tumor and ABPT samples was done using a Wilcoxon signed rank paired-sample statistical tests (two-sided). Independent intermediate- and high-grade samples were tested using a two-sided Wilcoxon rank-sum test. Number of patients in each group is indicated by N.

Journal: Cell Reports Medicine

Article Title: Single-cell proteomics defines the cellular heterogeneity of localized prostate cancer

doi: 10.1016/j.xcrm.2022.100604

Figure Lengend Snippet: Stratification of samples reveals prostate tissue changes associated with tumor and advanced disease (A) UMAP of 23,200 cells (400 per patient) colored by expression of indicated marker. (B) Representative tissue sample stained for CD3 from a tissue microarray generated from prostate samples from the same cohort analyzed by mass cytometry. (C) Densities of T cells as determined by CD3 staining (p = 0.042). (D) Representative tissue sample stained for CD15 from a tissue microarray generated from prostate samples from the same cohort analyzed by mass cytometry. (E) Densities of granulocytes as determined by CD15 staining (p = 0.058). Scale bar, 50 μm. (F) Proportion of T cell metaclusters in ABPT and tumor samples across patients with paired samples (p = 0.066, 0.169, 0.023, 0.002, and 0.332 for TC01–05, respectively). N = 17. (G) Summary table of clusters that were significant when comparing ABPT and tumor samples (N = 17 for both groups). Metaclusters enriched in ABPT are colored in blue, while those enriched in tumor samples are colored in red. Comparison between intermediate- and high-grade patient samples (for combined tumor/ABPT; intermediate N = 46 and high grade N = 12). Metaclusters enriched in patients with high-grade disease are colored in dark red. Only significant relationships are colored, and remaining comparisons are shown in gray. (H) Proportion of macrophage metaclusters in ABPT and tumor samples across patients with paired samples (p = 0.095, 0.169, 0.515, 0.0004, and 0.014 for MA01–05, respectively). N = 17. In panels (F) and (H), dots are colored by disease severity (intermediate versus high grade). In all boxplots, boxes illustrate the IQR (25th to 75th percentile), the median is shown as the middle band, and the whiskers extend to 1.5 times the IQR from the top (or bottom) of the box to the furthest datum within that distance. Statistical testing between dependent paired tumor and ABPT samples was done using a Wilcoxon signed rank paired-sample statistical tests (two-sided). Independent intermediate- and high-grade samples were tested using a two-sided Wilcoxon rank-sum test. Number of patients in each group is indicated by N.

Article Snippet: Mass cytometry data , Mendeley , https://doi.org/10.17632/5k5xfj 626k.1.

Techniques: Expressing, Marker, Staining, Microarray, Generated, Mass Cytometry, Comparison

Journal: Cell Reports Medicine

Article Title: Single-cell proteomics defines the cellular heterogeneity of localized prostate cancer

doi: 10.1016/j.xcrm.2022.100604

Figure Lengend Snippet:

Article Snippet: Mass cytometry data , Mendeley , https://doi.org/10.17632/5k5xfj 626k.1.

Techniques: Recombinant, Blocking Assay, Electron Microscopy, Labeling, Mass Cytometry, Software

Journal: Cell reports

Article Title: Multimodal analysis of dysregulated heme metabolism, hypoxic signaling, and stress erythropoiesis in Down syndrome

doi: 10.1016/j.celrep.2024.114599

Figure Lengend Snippet:

Article Snippet: HTP mass cytometry data , Galbraith et al. , Flow Repository: FR-FCM-Z5GE, Synapse: https://doi.org/10.7303/syn31488783.

Techniques: Binding Assay, Isolation, Biomarker Discovery, Staining, Antibody Labeling, Clinical Proteomics, Mass Cytometry, Software, Sequencing