|
Agiltron Inc
fiber probe with a gradient refractive index (grin) lens Fiber Probe With A Gradient Refractive Index (Grin) Lens, supplied by Agiltron Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/fiber+probe+gradient+refractive+index++grin++lens/10__1364_slash_boe__6__005021-316-1-10 Average 90 stars, based on 1 article reviews
fiber probe with a gradient refractive index (grin) lens - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Edmund Optics
single-mode optical fiber gradient-index (grin) lens Single Mode Optical Fiber Gradient Index (Grin) Lens, supplied by Edmund Optics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/single+mode+optical+fiber+gradient+index++grin++lens/pmc11561322-100-11-14 Average 90 stars, based on 1 article reviews
single-mode optical fiber gradient-index (grin) lens - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Thorlabs
grin-lens coupled 50 um diameter, long optical fiber Grin Lens Coupled 50 Um Diameter, Long Optical Fiber, supplied by Thorlabs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/grin+lens+coupled+50+um+diameter++long+optical+fiber/pmc03371152-36-46-49 Average 90 stars, based on 1 article reviews
grin-lens coupled 50 um diameter, long optical fiber - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Corning Life Sciences
grin fiber corning clearcurve om4 ![]() Grin Fiber Corning Clearcurve Om4, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/grin+fiber+corning+clearcurve+om4/pmc06907392-188-21-23 Average 90 stars, based on 1 article reviews
grin fiber corning clearcurve om4 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Fujikura Ltd
800 - μ m core grin fiber ![]() 800 μ M Core Grin Fiber, supplied by Fujikura Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/800+++%CE%BC+m+core+grin+fiber/pmc06907392-189-18-13 Average 90 stars, based on 1 article reviews
800 - μ m core grin fiber - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Fujikura Ltd
30-m fujikura 800 / 1000 - μ m grin fiber ![]() 30 M Fujikura 800 / 1000 μ M Grin Fiber, supplied by Fujikura Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/30+m+fujikura+800+++1000+++%CE%BC+m+grin+fiber/pmc06907392-195-21-14 Average 90 stars, based on 1 article reviews
30-m fujikura 800 / 1000 - μ m grin fiber - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
GRINTECH GmbH
grin lens fiber collimator grintech gt-smfp-050-025-50-nc-fc/pc ![]() Grin Lens Fiber Collimator Grintech Gt Smfp 050 025 50 Nc Fc/Pc, supplied by GRINTECH GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/grin+lens+fiber+collimator+grintech+gt+smfp+050+025+50+nc+fc+pc/10__1364_slash_oe__21__020911-302-12-16 Average 90 stars, based on 1 article reviews
grin lens fiber collimator grintech gt-smfp-050-025-50-nc-fc/pc - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Photonics Inc
grin fibers ![]() Grin Fibers, supplied by Photonics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/grin+fibers/pm37157354-147-15-6 Average 90 stars, based on 1 article reviews
grin fibers - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Thorlabs
grin fiber ![]() Grin Fiber, supplied by Thorlabs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/grin+fiber/pmc07782776__41467_2020_20438_MOESM1_ESM-25-13-57 Average 90 stars, based on 1 article reviews
grin fiber - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Corning Life Sciences
om2 graded-index (grin) fibers ![]() Om2 Graded Index (Grin) Fibers, supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/om2+graded+index++grin++fibers/pm40573602-127-6-12 Average 90 stars, based on 1 article reviews
om2 graded-index (grin) fibers - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
GRINTECH GmbH
single-mode optical fiber with a gradient index (grin) focusing lens ![]() Single Mode Optical Fiber With A Gradient Index (Grin) Focusing Lens, supplied by GRINTECH GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/single+mode+optical+fiber+with+a+gradient+index++grin++focusing+lens/pmc11662067-184-16-17 Average 90 stars, based on 1 article reviews
single-mode optical fiber with a gradient index (grin) focusing lens - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Autodesk Inc
adapter between the animal/grin lens and the fiber bundle system autodesk fusion 360 ![]() Adapter Between The Animal/Grin Lens And The Fiber Bundle System Autodesk Fusion 360, supplied by Autodesk Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/grin+fiber/adapter+between+the+animal+grin+lens+and+the+fiber+bundle+system+autodesk+fusion+360/pmc09900928-113-20-30 Average 90 stars, based on 1 article reviews
adapter between the animal/grin lens and the fiber bundle system autodesk fusion 360 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: List of optical fibers used in the spectral lifetime experiment. Some data are unavailable from the manufacturers. Values in italic are measured by authors.
Article Snippet: The impact of fiber diameter and fiber material on spectral separation was also studied (shown in ) with four types of
Techniques: Transmission Assay
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: (a) Estimated lifetime distribution with fiber dispersion for YG:red bead mixture. The averaged estimated lifetime for YG shifts from 2.2 to 2.1 ns and for red shifts from 2.8 to 3.18 ns. These delays ( − 0.1 ns ) and ( + 0.3 ns ) are an effect of the convolved spectral distribution with the real lifetime distribution of the observed photons. The colored curves are separable because of the fiber spectral dispersion. The green dotted line shows the YG beads and red dotted line shows the red beads with the fiber. The noncolored curves show the beads without fiber. (b) The estimated lifetime images in the same color scheme, with the color scale determined by the range of the estimated lifetime with fiber (2100 to 4500 ps). With the fiber, the dynamic range (thus, the contrast) of the image (b-i) increases compared to the (b-ii) nonfiber case. (c) Calibration curve for temporal delay due to fiber chromatic dispersion with respect to the change in the emission wavelength. For this calibration, second harmonic signal was measured for a series of wavelengths with the 30-m 800 - μ m GRIN fiber and used to create spectral LUT for the images. (d) Spectral images (obtained by mapping shift to spectrum) of the same measurements from (b) shown in the same spectral color scale. With the fiber, the red and YG beads can be visually identified in color, but there is no contrast and no meaningful spectral information is displayed.
Article Snippet: The impact of fiber diameter and fiber material on spectral separation was also studied (shown in ) with four types of
Techniques: Dispersion
Table 1 ). The fiber length (in meters) and fiber diameter (in μ m ) are marked below each image. The sample is a mixture of 10 - μ m YG (emission 486 nm) and 2 - μ m red fluorescent microspheres (emission 554 nm) excited at 490 nm. (c) and (d) The difference in averaged shift between two bead groups for 400 - μ m step-index fibers and 62.5 - μ m GRIN fibers of three lengths. Images were taken with a 20 × air objective ( NA = 0.75 ). The acquisition time was 60 s for all the images in this paper unless otherwise specified. " width="100%" height="100%">
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: Spectral separation (represented by relative temporal shift in ns between two bead groups) demonstrated with step-index and GRIN fibers of various lengths. The fibers used are (a) Thorlabs 400 / 425 - μ m step-index fibers and (b) Corning InfiniCor300 OM1 62.5 / 125 - μ m GRIN fibers of 10, 30, and 50 m in length, respectively (refer to
Article Snippet: The impact of fiber diameter and fiber material on spectral separation was also studied (shown in ) with four types of
Techniques:
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: Zemax simulation of the fiber coupling in the proposed system to study the theoretical limits of the transmission. The combination of f = 50 mm (diameter of 1 in.) and f = 20 mm (diameter of 1/2 in.) plano-convex lenses is used to reduce the beam diameter of fluorescent emission light, which is in turn focused to the tip of the fiber which is mounted to Thorlabs CFC-11x-A collimator by a built-in f = 11 mm aspheric lens ( NA = 0.3 ). At ± 0.85 - deg input scan angle to f = 50 mm lens, the FOV at the tip of the fiber is 800 μ m , matching the core diameter of Fujikura G.800/1000 GRIN fiber. Different colors represent different scan angles.
Article Snippet: The impact of fiber diameter and fiber material on spectral separation was also studied (shown in ) with four types of
Techniques: Transmission Assay
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: Spectral separation (translated to relative temporal shift in ns) demonstrated with 30-m-long GRIN fibers of various core diameters and material compositions. (a-i) Corning ClearCurve OM4, (a-ii) Corning InfiniCor300 OM1, (a-iii) Newport F-ML-D-C, and (a-iv) Fujikura G.800/1000. (a) Shift images are plotted with the same look up tables (LUTs) for all the fibers. The sample is a mixture of 10 - μ m YG (emission 486 nm) and 2 - μ m red fluorescent microspheres (emission 554 nm) excited at 490 nm. (b) The difference in shift between two bead groups for different fibers. Images were taken with a Nikon Plan Apo 20 × / 0.75 objective. In this experiment, 8x zoom was used to achieve the same FOV for all the fibers for a fair comparison.
Article Snippet: The impact of fiber diameter and fiber material on spectral separation was also studied (shown in ) with four types of
Techniques: Comparison
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: (a) Estimated lifetime distribution with fiber dispersion for YG:red bead mixture. The averaged estimated lifetime for YG shifts from 2.2 to 2.1 ns and for red shifts from 2.8 to 3.18 ns. These delays ( − 0.1 ns ) and ( + 0.3 ns ) are an effect of the convolved spectral distribution with the real lifetime distribution of the observed photons. The colored curves are separable because of the fiber spectral dispersion. The green dotted line shows the YG beads and red dotted line shows the red beads with the fiber. The noncolored curves show the beads without fiber. (b) The estimated lifetime images in the same color scheme, with the color scale determined by the range of the estimated lifetime with fiber (2100 to 4500 ps). With the fiber, the dynamic range (thus, the contrast) of the image (b-i) increases compared to the (b-ii) nonfiber case. (c) Calibration curve for temporal delay due to fiber chromatic dispersion with respect to the change in the emission wavelength. For this calibration, second harmonic signal was measured for a series of wavelengths with the 30-m 800 - μ m GRIN fiber and used to create spectral LUT for the images. (d) Spectral images (obtained by mapping shift to spectrum) of the same measurements from (b) shown in the same spectral color scale. With the fiber, the red and YG beads can be visually identified in color, but there is no contrast and no meaningful spectral information is displayed.
Article Snippet: From the images of relative temporal delays [the second column in ], clearly
Techniques: Dispersion
Table 1 ). The fiber length (in meters) and fiber diameter (in μ m ) are marked below each image. The sample is a mixture of 10 - μ m YG (emission 486 nm) and 2 - μ m red fluorescent microspheres (emission 554 nm) excited at 490 nm. (c) and (d) The difference in averaged shift between two bead groups for 400 - μ m step-index fibers and 62.5 - μ m GRIN fibers of three lengths. Images were taken with a 20 × air objective ( NA = 0.75 ). The acquisition time was 60 s for all the images in this paper unless otherwise specified. " width="100%" height="100%">
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: Spectral separation (represented by relative temporal shift in ns between two bead groups) demonstrated with step-index and GRIN fibers of various lengths. The fibers used are (a) Thorlabs 400 / 425 - μ m step-index fibers and (b) Corning InfiniCor300 OM1 62.5 / 125 - μ m GRIN fibers of 10, 30, and 50 m in length, respectively (refer to
Article Snippet: From the images of relative temporal delays [the second column in ], clearly
Techniques:
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: Zemax simulation of the fiber coupling in the proposed system to study the theoretical limits of the transmission. The combination of f = 50 mm (diameter of 1 in.) and f = 20 mm (diameter of 1/2 in.) plano-convex lenses is used to reduce the beam diameter of fluorescent emission light, which is in turn focused to the tip of the fiber which is mounted to Thorlabs CFC-11x-A collimator by a built-in f = 11 mm aspheric lens ( NA = 0.3 ). At ± 0.85 - deg input scan angle to f = 50 mm lens, the FOV at the tip of the fiber is 800 μ m , matching the core diameter of Fujikura G.800/1000 GRIN fiber. Different colors represent different scan angles.
Article Snippet: From the images of relative temporal delays [the second column in ], clearly
Techniques: Transmission Assay
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: Spectral separation (translated to relative temporal shift in ns) demonstrated with 30-m-long GRIN fibers of various core diameters and material compositions. (a-i) Corning ClearCurve OM4, (a-ii) Corning InfiniCor300 OM1, (a-iii) Newport F-ML-D-C, and (a-iv) Fujikura G.800/1000. (a) Shift images are plotted with the same look up tables (LUTs) for all the fibers. The sample is a mixture of 10 - μ m YG (emission 486 nm) and 2 - μ m red fluorescent microspheres (emission 554 nm) excited at 490 nm. (b) The difference in shift between two bead groups for different fibers. Images were taken with a Nikon Plan Apo 20 × / 0.75 objective. In this experiment, 8x zoom was used to achieve the same FOV for all the fibers for a fair comparison.
Article Snippet: From the images of relative temporal delays [the second column in ], clearly
Techniques: Comparison
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: (a) Estimated lifetime distribution with fiber dispersion for YG:red bead mixture. The averaged estimated lifetime for YG shifts from 2.2 to 2.1 ns and for red shifts from 2.8 to 3.18 ns. These delays ( − 0.1 ns ) and ( + 0.3 ns ) are an effect of the convolved spectral distribution with the real lifetime distribution of the observed photons. The colored curves are separable because of the fiber spectral dispersion. The green dotted line shows the YG beads and red dotted line shows the red beads with the fiber. The noncolored curves show the beads without fiber. (b) The estimated lifetime images in the same color scheme, with the color scale determined by the range of the estimated lifetime with fiber (2100 to 4500 ps). With the fiber, the dynamic range (thus, the contrast) of the image (b-i) increases compared to the (b-ii) nonfiber case. (c) Calibration curve for temporal delay due to fiber chromatic dispersion with respect to the change in the emission wavelength. For this calibration, second harmonic signal was measured for a series of wavelengths with the 30-m 800 - μ m GRIN fiber and used to create spectral LUT for the images. (d) Spectral images (obtained by mapping shift to spectrum) of the same measurements from (b) shown in the same spectral color scale. With the fiber, the red and YG beads can be visually identified in color, but there is no contrast and no meaningful spectral information is displayed.
Article Snippet: Thus, out of the fibers that we are in possession of , the 30-m
Techniques: Dispersion
Table 1 ). The fiber length (in meters) and fiber diameter (in μ m ) are marked below each image. The sample is a mixture of 10 - μ m YG (emission 486 nm) and 2 - μ m red fluorescent microspheres (emission 554 nm) excited at 490 nm. (c) and (d) The difference in averaged shift between two bead groups for 400 - μ m step-index fibers and 62.5 - μ m GRIN fibers of three lengths. Images were taken with a 20 × air objective ( NA = 0.75 ). The acquisition time was 60 s for all the images in this paper unless otherwise specified. " width="100%" height="100%">
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: Spectral separation (represented by relative temporal shift in ns between two bead groups) demonstrated with step-index and GRIN fibers of various lengths. The fibers used are (a) Thorlabs 400 / 425 - μ m step-index fibers and (b) Corning InfiniCor300 OM1 62.5 / 125 - μ m GRIN fibers of 10, 30, and 50 m in length, respectively (refer to
Article Snippet: Thus, out of the fibers that we are in possession of , the 30-m
Techniques:
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: Zemax simulation of the fiber coupling in the proposed system to study the theoretical limits of the transmission. The combination of f = 50 mm (diameter of 1 in.) and f = 20 mm (diameter of 1/2 in.) plano-convex lenses is used to reduce the beam diameter of fluorescent emission light, which is in turn focused to the tip of the fiber which is mounted to Thorlabs CFC-11x-A collimator by a built-in f = 11 mm aspheric lens ( NA = 0.3 ). At ± 0.85 - deg input scan angle to f = 50 mm lens, the FOV at the tip of the fiber is 800 μ m , matching the core diameter of Fujikura G.800/1000 GRIN fiber. Different colors represent different scan angles.
Article Snippet: Thus, out of the fibers that we are in possession of , the 30-m
Techniques: Transmission Assay
Journal: Journal of Biomedical Optics
Article Title: Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems
doi: 10.1117/1.JBO.25.1.014506
Figure Lengend Snippet: Spectral separation (translated to relative temporal shift in ns) demonstrated with 30-m-long GRIN fibers of various core diameters and material compositions. (a-i) Corning ClearCurve OM4, (a-ii) Corning InfiniCor300 OM1, (a-iii) Newport F-ML-D-C, and (a-iv) Fujikura G.800/1000. (a) Shift images are plotted with the same look up tables (LUTs) for all the fibers. The sample is a mixture of 10 - μ m YG (emission 486 nm) and 2 - μ m red fluorescent microspheres (emission 554 nm) excited at 490 nm. (b) The difference in shift between two bead groups for different fibers. Images were taken with a Nikon Plan Apo 20 × / 0.75 objective. In this experiment, 8x zoom was used to achieve the same FOV for all the fibers for a fair comparison.
Article Snippet: Thus, out of the fibers that we are in possession of , the 30-m
Techniques: Comparison