|
Revvity
ivis optical imaging platform Ivis Optical Imaging Platform, supplied by Revvity, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/custom%40cls158738%4041377661?v=Revvity Average 96 stars, based on 1 article reviews
ivis optical imaging platform - by Bioz Stars,
2026-08
96/100 stars
|
Buy from Supplier |
|
Canon inc
ivim, asl, and dsc mri images Ivim, Asl, And Dsc Mri Images, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/pm31656295-43-0-12?v=Canon+inc Average 90 stars, based on 1 article reviews
ivim, asl, and dsc mri images - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Siemens AG
1.5t siemens mri ![]() 1.5t Siemens Mri, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/pmc10360195-10-9-7?v=Siemens+AG Average 90 stars, based on 1 article reviews
1.5t siemens mri - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Siemens AG
mp2rage sequence ![]() Mp2rage Sequence, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/pm38263061-227-11-16?v=Siemens+AG Average 90 stars, based on 1 article reviews
mp2rage sequence - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
FUJIFILM
ivim application ![]() Ivim Application, supplied by FUJIFILM, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/pm36639789-1483-23-29?v=FUJIFILM Average 90 stars, based on 1 article reviews
ivim application - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Siemens AG
pcasl sequence ![]() Pcasl Sequence, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/pmc10804658-348-10-15?v=Siemens+AG Average 90 stars, based on 1 article reviews
pcasl sequence - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
FUJIFILM
ivim map ![]() Ivim Map, supplied by FUJIFILM, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/pmc11270171-93-16-18?v=FUJIFILM Average 90 stars, based on 1 article reviews
ivim map - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Siemens AG
ivim work-in-progress package (mr body diffusion toolbox version 1.3.0) ![]() Ivim Work In Progress Package (Mr Body Diffusion Toolbox Version 1.3.0), supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/pmc08924456-151-23-23?v=Siemens+AG Average 90 stars, based on 1 article reviews
ivim work-in-progress package (mr body diffusion toolbox version 1.3.0) - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Siemens AG
ivim parametric maps ![]() Ivim Parametric Maps, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/pmc11891049__DataSheet1-13-3-35?v=Siemens+AG Average 90 stars, based on 1 article reviews
ivim parametric maps - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Philips Healthcare
ivim dwi tool ![]() Ivim Dwi Tool, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/pmc10649527-40-23-26?v=Philips+Healthcare Average 86 stars, based on 1 article reviews
ivim dwi tool - by Bioz Stars,
2026-08
86/100 stars
|
Buy from Supplier |
|
Siemens AG
attenuation curve fitting ![]() Attenuation Curve Fitting, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/pm23633178-159-8-5?v=Siemens+AG Average 90 stars, based on 1 article reviews
attenuation curve fitting - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
IVIM Technology
zoomit ivim ![]() Zoomit Ivim, supplied by IVIM Technology, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/function+for+bayesian+ivim+model+fitting/pmc08961020-162-23-24?v=IVIM+Technology Average 90 stars, based on 1 article reviews
zoomit ivim - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Frontiers in Endocrinology
Article Title: The value of functional magnetic resonance imaging in the evaluation of diabetic kidney disease: a systematic review and meta-analysis
doi: 10.3389/fendo.2023.1226830
Figure Lengend Snippet: Characteristics of the included studies.
Article Snippet: Deng 2018 ( ) , 1.5T ,
Techniques:
Journal: Neurology International
Article Title: A Case of Idiopathic Intracranial Hypertension Complicated with both Infratentorial and Supratentorial Cortical Superficial Siderosis: Novel Imaging Findings on Intravoxel Incoherent Motion Magnetic Resonance Imaging Offering Clues to Pathophysiology
doi: 10.3390/neurolint16040053
Figure Lengend Snippet: IVIM MRI findings showing the intracranial hypertension state and intracranial pressure reduction with acetazolamide administration. ( a ). IVIM MRI in the intracranial hypertension state before oral acetazolamide treatment, ( b ). IVIM MRI showing decreased intracranial pressure after oral acetazolamide treatment. IVIM MRI: intravoxel incoherent motion magnetic resonance imaging.
Article Snippet: Intravoxel incoherent motion (IVIM) MRI, which was used to visualize CSF movement [ ], using the
Techniques: Magnetic Resonance Imaging
Journal: Neurology International
Article Title: A Case of Idiopathic Intracranial Hypertension Complicated with both Infratentorial and Supratentorial Cortical Superficial Siderosis: Novel Imaging Findings on Intravoxel Incoherent Motion Magnetic Resonance Imaging Offering Clues to Pathophysiology
doi: 10.3390/neurolint16040053
Figure Lengend Snippet: Mean f values (%) in IVIM MRI in the IICP state before treatment and decreased ICP state after treatment.
Article Snippet: Intravoxel incoherent motion (IVIM) MRI, which was used to visualize CSF movement [ ], using the
Techniques:
Journal: Frontiers in Neuroscience
Article Title: Intravoxel Incoherent Motion Magnetic Resonance Imaging Used in Preoperative Screening of High-Risk Patients With Moyamoya Disease Who May Develop Postoperative Cerebral Hyperperfusion Syndrome
doi: 10.3389/fnins.2022.826021
Figure Lengend Snippet: MRI scanning sequences and parameters.
Article Snippet: Four parameters, including apparent diffusion coefficient (ADC), diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f), were calculated and derived using a
Techniques:
Journal: Frontiers in Neuroscience
Article Title: Intravoxel Incoherent Motion Magnetic Resonance Imaging Used in Preoperative Screening of High-Risk Patients With Moyamoya Disease Who May Develop Postoperative Cerebral Hyperperfusion Syndrome
doi: 10.3389/fnins.2022.826021
Figure Lengend Snippet: Intravoxel incoherent motion MRI imaging obtained after post-processing (the columns show three different levels, peripheral white matter level, basal ganglia level, cerebellar hemisphere level; the line shows four different IVIM parameters, ADC, D, f, D*value). (A–C) Image of ADC value; (D–F) image of D -value; (G–I) image of f value; (J–L) image of D* value.
Article Snippet: Four parameters, including apparent diffusion coefficient (ADC), diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f), were calculated and derived using a
Techniques: Imaging
Journal: Frontiers in Neuroscience
Article Title: Intravoxel Incoherent Motion Magnetic Resonance Imaging Used in Preoperative Screening of High-Risk Patients With Moyamoya Disease Who May Develop Postoperative Cerebral Hyperperfusion Syndrome
doi: 10.3389/fnins.2022.826021
Figure Lengend Snippet: The placement of ROIs on IVIM images in three different level. (A) peripheral white matter level; (B) basal ganglia level; (C) cerebellar hemisphere level. A total of 22 ROIs were placed symmetrically on the three transverse images.
Article Snippet: Four parameters, including apparent diffusion coefficient (ADC), diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f), were calculated and derived using a
Techniques:
Journal: Frontiers in Neuroscience
Article Title: Intravoxel Incoherent Motion Magnetic Resonance Imaging Used in Preoperative Screening of High-Risk Patients With Moyamoya Disease Who May Develop Postoperative Cerebral Hyperperfusion Syndrome
doi: 10.3389/fnins.2022.826021
Figure Lengend Snippet: Examination results of the MMD and control groups.
Article Snippet: Four parameters, including apparent diffusion coefficient (ADC), diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f), were calculated and derived using a
Techniques: Control
Journal: Korean Journal of Radiology
Article Title: Comparative Study between ZOOMit and Conventional Intravoxel Incoherent Motion MRI for Assessing Parotid Gland Abnormalities in Patients with Early- or Mid-Stage Sjögren’s Syndrome
doi: 10.3348/kjr.2021.0695
Figure Lengend Snippet: MRI Protocols for ZOOMit and Conventional Imaging
Article Snippet: Especially for patients with mild parotid gland symptoms and normal morphology, the subtle changes in the parotid glands can be detected earlier with
Techniques:
Journal: Korean Journal of Radiology
Article Title: Comparative Study between ZOOMit and Conventional Intravoxel Incoherent Motion MRI for Assessing Parotid Gland Abnormalities in Patients with Early- or Mid-Stage Sjögren’s Syndrome
doi: 10.3348/kjr.2021.0695
Figure Lengend Snippet: A. Maximum overlap of the IVIM curve and the fitting line of ZOOMit IVIM images. B1-3. The generated D, f, and D * maps of ZOOMit IVIM images. C. The ROI was placed at least 2 mm from the left parotid margin on the ZOOMit DWI scan (b = 0 s/mm 2 ). D1-3. The same ROI was placed on the D, f, and D * maps of ZOOMit IVIM images to obtain the corresponding Z-D, Z-f, and Z-D * values, respectively. E. Maximum overlap of the IVIM curve and the fitting line of conventional IVIM images. F1-3. The generated D, f, and D * maps of conventional IVIM images. G. The ROI was placed at least 2 mm from the left parotid margin on a conventional DWI image (b = 0 s/mm 2 ). H1-3. The same ROI was placed on the D, f, and D * maps of conventional IVIM images to obtain the corresponding C-D, C-f, and C-D * values, respectively. C-D = conventional diffusion coefficient, C-D * = conventional pseudodiffusion coefficient, C-f = conventional perfusion fraction, DWI = diffusion-weighted imaging, IVIM = intravoxel incoherent motion, ROI = region of interest, Z-D = ZOOMit diffusion coefficient, Z-D * = ZOOMit pseudodiffusion coefficient, Z-f = ZOOMit perfusion fraction
Article Snippet: Especially for patients with mild parotid gland symptoms and normal morphology, the subtle changes in the parotid glands can be detected earlier with
Techniques: Generated, Diffusion-based Assay, Imaging
Journal: Korean Journal of Radiology
Article Title: Comparative Study between ZOOMit and Conventional Intravoxel Incoherent Motion MRI for Assessing Parotid Gland Abnormalities in Patients with Early- or Mid-Stage Sjögren’s Syndrome
doi: 10.3348/kjr.2021.0695
Figure Lengend Snippet: Intra- and Interobserver ICCs for the Measurements Derived from Conventional and ZOOMit IVIM Images of Parotid Glands
Article Snippet: Especially for patients with mild parotid gland symptoms and normal morphology, the subtle changes in the parotid glands can be detected earlier with
Techniques: Derivative Assay
Journal: Korean Journal of Radiology
Article Title: Comparative Study between ZOOMit and Conventional Intravoxel Incoherent Motion MRI for Assessing Parotid Gland Abnormalities in Patients with Early- or Mid-Stage Sjögren’s Syndrome
doi: 10.3348/kjr.2021.0695
Figure Lengend Snippet: Comparison of ZOOMit and Conventional Intravoxel Incoherent Motion Parameters between the Left and Right Parotid Glands
Article Snippet: Especially for patients with mild parotid gland symptoms and normal morphology, the subtle changes in the parotid glands can be detected earlier with
Techniques: Comparison
Journal: Korean Journal of Radiology
Article Title: Comparative Study between ZOOMit and Conventional Intravoxel Incoherent Motion MRI for Assessing Parotid Gland Abnormalities in Patients with Early- or Mid-Stage Sjögren’s Syndrome
doi: 10.3348/kjr.2021.0695
Figure Lengend Snippet: Comparison of ZOOMit and Conventional IVIM Parameters between SS and HC Groups
Article Snippet: Especially for patients with mild parotid gland symptoms and normal morphology, the subtle changes in the parotid glands can be detected earlier with
Techniques: Comparison
Journal: Korean Journal of Radiology
Article Title: Comparative Study between ZOOMit and Conventional Intravoxel Incoherent Motion MRI for Assessing Parotid Gland Abnormalities in Patients with Early- or Mid-Stage Sjögren’s Syndrome
doi: 10.3348/kjr.2021.0695
Figure Lengend Snippet: Z-D, Z-f, and Z-D * maps (A1-C1) and C-D, C-f, and C-D * maps (A2-C2) of a 52-year-old female SS patient. Z-D, Z-f, and Z-D * maps (D1-F1) and C-D, C-f, and C-D * maps (D2-F2) of a 57-year-old male HC. The Z-f value of the SS patient was higher than that of the HC, and SS can be correctly diagnosed with a Z-f value greater than 0.120 in both the left and right parotid glands (B1) . The Z-D * value of the SS patient was higher than that of the HC, and SS can be correctly diagnosed with a Z-D * value greater than 51.25 mm 2 /s in both the left and right parotid glands (C1) . The C-D * value was high in both the SS patient and HC, and the right normal parotid gland was misdiagnosed as SS. C-D = conventional diffusion coefficient, C-D * = conventional pseudodiffusion coefficient, C-f = conventional perfusion fraction, D = diffusion coefficient, D * = pseudodiffusion coefficient, f = perfusion fraction, HC = healthy control, SS = Sjögren’s syndrome, Z-D = ZOOMit diffusion coefficient, Z-D * = ZOOMit pseudodiffusion coefficient, Z-f = ZOOMit perfusion fraction
Article Snippet: Especially for patients with mild parotid gland symptoms and normal morphology, the subtle changes in the parotid glands can be detected earlier with
Techniques: Diffusion-based Assay, Control
Journal: Korean Journal of Radiology
Article Title: Comparative Study between ZOOMit and Conventional Intravoxel Incoherent Motion MRI for Assessing Parotid Gland Abnormalities in Patients with Early- or Mid-Stage Sjögren’s Syndrome
doi: 10.3348/kjr.2021.0695
Figure Lengend Snippet: The Delong test demonstrated that the diagnostic efficiency of the combined indicators was greater than that of any single diagnostic indicator (all p < 0.01). AUC = area under the curve, C-D * = conventional pseudodiffusion coefficient, MRG = MR gland nodular grade, Z-D * = ZOOMit pseudodiffusion coefficient, Z-f = ZOOMit perfusion fraction
Article Snippet: Especially for patients with mild parotid gland symptoms and normal morphology, the subtle changes in the parotid glands can be detected earlier with
Techniques: Diagnostic Assay