customized petri dish Search Results


90
Dow Chemical custom-made black sylgard 184-coated petri dish
Setup of an ex vivo system for an isolated zebrafish heart. (A) Equipment needed, including a dissecting microscope (1), with a camera (2), pump (3) and stimulator (4). (B) Two-line 34G catheters (5) are placed on a <t>Sylgard-coated</t> Petri dish with the use of insect pins; 2 hearts are tied on the ends of the catheters (inset depicts the position of a cannula in the heart; arrowhead points to the place of the tie by the atrioventricular junction), which are put in front of a mirror (6); platinum electrodes (7) are used for electrical field stimulation. A pool (8) was made to control the solution level. (C) Diagram of <t>the</t> <t>perfusion</t> system.
Custom Made Black Sylgard 184 Coated Petri Dish, supplied by Dow Chemical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/customized+petri+dish/custom+made+black+sylgard+184+coated+petri+dish/pmc06177000-209-27-30
Average 90 stars, based on 1 article reviews
custom-made black sylgard 184-coated petri dish - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Setup of an ex vivo system for an isolated zebrafish heart. (A) Equipment needed, including a dissecting microscope (1), with a camera (2), pump (3) and stimulator (4). (B) Two-line 34G catheters (5) are placed on a Sylgard-coated Petri dish with the use of insect pins; 2 hearts are tied on the ends of the catheters (inset depicts the position of a cannula in the heart; arrowhead points to the place of the tie by the atrioventricular junction), which are put in front of a mirror (6); platinum electrodes (7) are used for electrical field stimulation. A pool (8) was made to control the solution level. (C) Diagram of the perfusion system.

Journal: Disease Models & Mechanisms

Article Title: A Langendorff-like system to quantify cardiac pump function in adult zebrafish

doi: 10.1242/dmm.034819

Figure Lengend Snippet: Setup of an ex vivo system for an isolated zebrafish heart. (A) Equipment needed, including a dissecting microscope (1), with a camera (2), pump (3) and stimulator (4). (B) Two-line 34G catheters (5) are placed on a Sylgard-coated Petri dish with the use of insect pins; 2 hearts are tied on the ends of the catheters (inset depicts the position of a cannula in the heart; arrowhead points to the place of the tie by the atrioventricular junction), which are put in front of a mirror (6); platinum electrodes (7) are used for electrical field stimulation. A pool (8) was made to control the solution level. (C) Diagram of the perfusion system.

Article Snippet: An explanted ventricle is sutured onto the tip of a 34G catheter placed onto the perfusion plate, and the perfusion plate is set onto a custom-made black Sylgard (Sylgard 184; Dow Chemical Company)-coated Petri dish ( B).

Techniques: Ex Vivo, Isolation, Microscopy, Control