u3000 rslc hplc  (Thermo Fisher)


Bioz Verified Symbol Thermo Fisher is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 88

    Structured Review

    Thermo Fisher u3000 rslc hplc
    U3000 Rslc Hplc, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 88/100, based on 10 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/u3000 rslc hplc/product/Thermo Fisher
    Average 88 stars, based on 10 article reviews
    Price from $9.99 to $1999.99
    u3000 rslc hplc - by Bioz Stars, 2020-09
    88/100 stars

    Images

    Related Articles

    High Performance Liquid Chromatography:

    Article Title: The threonine degradation pathway of the Trypanosoma brucei procyclic form: the main carbon source for lipid biosynthesis is under metabolic control
    Article Snippet: .. Samples were analysed on an Exactive Orbitrap mass spectrometer (Thermo Fisher) in both positive and negative modes (rapid switching), coupled to a U3000 RSLC HPLC (Dionex) with a ZIC-HILIC column (Sequant) as has previously been described (Vincent et al ., ). .. All samples from an individual experiment were analysed in the same analytical batch and the quality of chromatography and signal reproducibility were checked by analysis of quality control samples, internal standards and total ion chromatograms.

    Article Title: Characterisation of the biochemical and cellular roles of native and pathogenic amelogenesis imperfecta mutants of FAM83H
    Article Snippet: .. Peptides were then analysed by mass spectrometry using Liquid Chromatography-tandem Mass spectrometry (LC-MS/MS) on a Linear ion trap-orbitrap hybrid mass spectrometer (Orbitrap-VelosPro, Thermo) coupled to a U3000 RSLC HPLC (Rapid Separation/High Performance Liquid Chromatography; Thermo). ..

    Article Title: Optimized Method for Untargeted Metabolomics Analysis of MDA-MB-231 Breast Cancer Cells
    Article Snippet: .. This was done using a ZIC-pHILIC 150 mm × 4.6 mm, 5 µm column (Merck Sequant, Darmstadt, Germany), which was coupled to a U3000 RSLC HPLC (Dionex, Thermo Fisher Scientific, Germering, Germany) The mobile phase (A) consisted of 20 mM ammonium carbonate in Milli-Q water and mobile phase (B) was comprised of 100% acetonitrile. ..

    Article Title: Untargeted Metabolomics Reveals a Lack Of Synergy between Nifurtimox and Eflornithine against Trypanosoma brucei
    Article Snippet: .. Mass spectrometry Samples were analysed on an Exactive Orbitrap mass spectrometer (Thermo Fisher) in both positive and negative modes (rapid switching), coupled to a U3000 RSLC HPLC (Dionex) with a ZIC-HILIC column (Sequant) as has previously been described . .. All samples from an individual experiment were analysed in the same analytical batch and the quality of chromatography and signal reproducibility were checked by analysis of quality control samples, internal standards and total ion chromatograms.

    Article Title: FAM83F regulates canonical Wnt signalling through an interaction with CK1α
    Article Snippet: .. Mass spectrometry analysis of the peptides was performed by LC-MS/MS on the Linear Ion Trap-Orbitrap Hybris Mass Spectrometer (Orbitrap Velos Pro, Thermo Fisher Scientific) coupled to a U3000 RSLC Hplc (Thermo Fisher Scientific). .. Peptides were trapped on a nanoViper Trap column and (2 cm x 100 μm, C18, 5 μm, 100 Å; Thermo Fisher Scientific) and then separated on a 15 cm EASY-spray column (ES800, Thermo Fisher Scientific) equilibrated with a flow of 300 nl/ml of 3% solvent B[80% acetonitrile, 0.08% formic acis, 3% DMSO in H2O].

    Article Title: Specificity for deubiquitination of monoubiquitinated FANCD2 is driven by the N-terminus of USP1
    Article Snippet: .. The peptides were subjected to mass spectrometric analysis performed by LC-MS-MS on a linear ion trap-Orbitrap hybrid mass spectrometer (Orbitrap-VelosPro; Thermo Fisher Scientific) coupled to a U3000 RSLC HPLC (Thermo Fisher Scientific). .. Data files were analysed by Proteome Discoverer 2.0 ( www.ThermoScientific.com ), using Mascot 2.4.1 protein identification software ( www.matrixscience.com ) by searching against an in-house protein database.

    Article Title: Characterisation of the Cullin-3 mutation that causes a severe form of familial hypertension and hyperkalaemia
    Article Snippet: .. Mass spectrometric analysis was performed by LC-MS-MS on a linear ion trap–orbitrap hybrid mass spectrometer (Orbitrap-VelosPro; Thermo) coupled to a U3000 RSLC HPLC (Thermo). .. Peptides were trapped on a NanoViper trap column, 2 cm × 100 mm C18 5 mm 100 Å (Thermo, 164564) and then separated on a 15-cm Thermo EasySpray column (ES800) equilibrated with a flow of 300 nl/min of 3% solvent B [solvent A: 2% acetonitrile, 0.1% formic acid and 3% DMSO in H2 O; solvent B: 80% acetonitrile, 0.08% formic acid and 3% DMSO in H2 O].

    Article Title: Macromolecular biosynthetic parameters and metabolic profile in different life stages of Leishmania braziliensis: Amastigotes as a functionally less active stage
    Article Snippet: .. Samples were analyzed by Liquid Chromatography and Mass Spectrometry on an Exactive Orbitrap mass spectrometer (Thermo Fisher) at the Scottish Metabolomics Facility (Glasgow Polyomics, University of Glasgow) in both positive and negative modes (rapid switching), coupled to a U3000 RSLC HPLC (Dionex) with a 2.1 mm ZIC-HILIC column (Sequant) as described previously [ ]. ..

    Mass Spectrometry:

    Article Title: The threonine degradation pathway of the Trypanosoma brucei procyclic form: the main carbon source for lipid biosynthesis is under metabolic control
    Article Snippet: .. Samples were analysed on an Exactive Orbitrap mass spectrometer (Thermo Fisher) in both positive and negative modes (rapid switching), coupled to a U3000 RSLC HPLC (Dionex) with a ZIC-HILIC column (Sequant) as has previously been described (Vincent et al ., ). .. All samples from an individual experiment were analysed in the same analytical batch and the quality of chromatography and signal reproducibility were checked by analysis of quality control samples, internal standards and total ion chromatograms.

    Article Title: Characterisation of the biochemical and cellular roles of native and pathogenic amelogenesis imperfecta mutants of FAM83H
    Article Snippet: .. Peptides were then analysed by mass spectrometry using Liquid Chromatography-tandem Mass spectrometry (LC-MS/MS) on a Linear ion trap-orbitrap hybrid mass spectrometer (Orbitrap-VelosPro, Thermo) coupled to a U3000 RSLC HPLC (Rapid Separation/High Performance Liquid Chromatography; Thermo). ..

    Article Title: Untargeted Metabolomics Reveals a Lack Of Synergy between Nifurtimox and Eflornithine against Trypanosoma brucei
    Article Snippet: .. Mass spectrometry Samples were analysed on an Exactive Orbitrap mass spectrometer (Thermo Fisher) in both positive and negative modes (rapid switching), coupled to a U3000 RSLC HPLC (Dionex) with a ZIC-HILIC column (Sequant) as has previously been described . .. All samples from an individual experiment were analysed in the same analytical batch and the quality of chromatography and signal reproducibility were checked by analysis of quality control samples, internal standards and total ion chromatograms.

    Article Title: FAM83F regulates canonical Wnt signalling through an interaction with CK1α
    Article Snippet: .. Mass spectrometry analysis of the peptides was performed by LC-MS/MS on the Linear Ion Trap-Orbitrap Hybris Mass Spectrometer (Orbitrap Velos Pro, Thermo Fisher Scientific) coupled to a U3000 RSLC Hplc (Thermo Fisher Scientific). .. Peptides were trapped on a nanoViper Trap column and (2 cm x 100 μm, C18, 5 μm, 100 Å; Thermo Fisher Scientific) and then separated on a 15 cm EASY-spray column (ES800, Thermo Fisher Scientific) equilibrated with a flow of 300 nl/ml of 3% solvent B[80% acetonitrile, 0.08% formic acis, 3% DMSO in H2O].

    Article Title: Specificity for deubiquitination of monoubiquitinated FANCD2 is driven by the N-terminus of USP1
    Article Snippet: .. The peptides were subjected to mass spectrometric analysis performed by LC-MS-MS on a linear ion trap-Orbitrap hybrid mass spectrometer (Orbitrap-VelosPro; Thermo Fisher Scientific) coupled to a U3000 RSLC HPLC (Thermo Fisher Scientific). .. Data files were analysed by Proteome Discoverer 2.0 ( www.ThermoScientific.com ), using Mascot 2.4.1 protein identification software ( www.matrixscience.com ) by searching against an in-house protein database.

    Article Title: Characterisation of the Cullin-3 mutation that causes a severe form of familial hypertension and hyperkalaemia
    Article Snippet: .. Mass spectrometric analysis was performed by LC-MS-MS on a linear ion trap–orbitrap hybrid mass spectrometer (Orbitrap-VelosPro; Thermo) coupled to a U3000 RSLC HPLC (Thermo). .. Peptides were trapped on a NanoViper trap column, 2 cm × 100 mm C18 5 mm 100 Å (Thermo, 164564) and then separated on a 15-cm Thermo EasySpray column (ES800) equilibrated with a flow of 300 nl/min of 3% solvent B [solvent A: 2% acetonitrile, 0.1% formic acid and 3% DMSO in H2 O; solvent B: 80% acetonitrile, 0.08% formic acid and 3% DMSO in H2 O].

    Article Title: Macromolecular biosynthetic parameters and metabolic profile in different life stages of Leishmania braziliensis: Amastigotes as a functionally less active stage
    Article Snippet: .. Samples were analyzed by Liquid Chromatography and Mass Spectrometry on an Exactive Orbitrap mass spectrometer (Thermo Fisher) at the Scottish Metabolomics Facility (Glasgow Polyomics, University of Glasgow) in both positive and negative modes (rapid switching), coupled to a U3000 RSLC HPLC (Dionex) with a 2.1 mm ZIC-HILIC column (Sequant) as described previously [ ]. ..

    Chromatography:

    Article Title: Characterisation of the biochemical and cellular roles of native and pathogenic amelogenesis imperfecta mutants of FAM83H
    Article Snippet: .. Peptides were then analysed by mass spectrometry using Liquid Chromatography-tandem Mass spectrometry (LC-MS/MS) on a Linear ion trap-orbitrap hybrid mass spectrometer (Orbitrap-VelosPro, Thermo) coupled to a U3000 RSLC HPLC (Rapid Separation/High Performance Liquid Chromatography; Thermo). ..

    Liquid Chromatography:

    Article Title: Characterisation of the biochemical and cellular roles of native and pathogenic amelogenesis imperfecta mutants of FAM83H
    Article Snippet: .. Peptides were then analysed by mass spectrometry using Liquid Chromatography-tandem Mass spectrometry (LC-MS/MS) on a Linear ion trap-orbitrap hybrid mass spectrometer (Orbitrap-VelosPro, Thermo) coupled to a U3000 RSLC HPLC (Rapid Separation/High Performance Liquid Chromatography; Thermo). ..

    Article Title: Macromolecular biosynthetic parameters and metabolic profile in different life stages of Leishmania braziliensis: Amastigotes as a functionally less active stage
    Article Snippet: .. Samples were analyzed by Liquid Chromatography and Mass Spectrometry on an Exactive Orbitrap mass spectrometer (Thermo Fisher) at the Scottish Metabolomics Facility (Glasgow Polyomics, University of Glasgow) in both positive and negative modes (rapid switching), coupled to a U3000 RSLC HPLC (Dionex) with a 2.1 mm ZIC-HILIC column (Sequant) as described previously [ ]. ..

    Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 88
    Thermo Fisher nanoflow hplc instrument
    Nanoflow Hplc Instrument, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 88/100, based on 6 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/nanoflow hplc instrument/product/Thermo Fisher
    Average 88 stars, based on 6 article reviews
    Price from $9.99 to $1999.99
    nanoflow hplc instrument - by Bioz Stars, 2020-09
    88/100 stars
      Buy from Supplier

    88
    Thermo Fisher u3000 rslc hplc
    U3000 Rslc Hplc, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 88/100, based on 10 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/u3000 rslc hplc/product/Thermo Fisher
    Average 88 stars, based on 10 article reviews
    Price from $9.99 to $1999.99
    u3000 rslc hplc - by Bioz Stars, 2020-09
    88/100 stars
      Buy from Supplier

    Image Search Results