Structured Review

Phenomenex kinetex hilic
Kinetex Hilic, supplied by Phenomenex, used in various techniques. Bioz Stars score: 88/100, based on 5 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/kinetex hilic/product/Phenomenex
Average 88 stars, based on 5 article reviews
Price from $9.99 to $1999.99
kinetex hilic - by Bioz Stars, 2020-07
88/100 stars

Images

Related Articles

Hydrophilic Interaction Liquid Chromatography:

Article Title: Pharmacokinetics of the evogliptin/metformin extended-release (5/1,000 mg) fixed-dose combination formulation compared to the corresponding loose combination, and food effect in healthy subjects
Article Snippet: .. Chromatographic separation was performed under gradient conditions using a Venusil ASB C8 column (50.0×2.1 mm, 3 μm; Agela, Wilmington, DE, USA) for evogliptin and using a Kinetex HILIC 100 Å column (hydrophilic interaction liquid chromatography column; 100.0×2.1 mm, 2.6 μm; Phenomenex, Torrance, CA, USA) for metformin. ..

Article Title: Transcriptome analysis of Brachypodium during fungal pathogen infection reveals both shared and distinct defense responses with wheat
Article Snippet: .. For detection of benzoxazalin-2-one, 6-methoxy-benzoxazalinone and secologanin, samples were passed through a Kinetex C18 1.7 µm column (Phenomenex 2.1 mm × 100 mm) with parameters given in Powell et al . while for detection of gramine, serotonin and tryptamine, samples were passed through a Kinetex HILIC 2.6 µm column (Phenomenex 2.1 mm × 100 mm) at 0.4 mL/min over 15 minutes at 40 °C with the following gradient: 100% solvent B for two minutes, a linear gradient from 100–60% solvent B over six minutes, a linear gradient from 60–5% over two minutes, followed by two minutes at 5% solvent B and an equilibration at 100% B. ..

Article Title: Assessment of l-Asparaginase Pharmacodynamics in Mouse Models of Cancer
Article Snippet: .. A Kinetex HILIC (100 × 2.1 mm, 1.7 µm particle size) analytical column from Phenomenex (Torrance, CA, USA) was used for chromatographic separation of ASNase PD markers. .. Chromatographic data were acquired using a 1290 Infinity Binary UHPLC system coupled to a 6460 tandem-mass spectrometer produced by Agilent Technologies (Santa Clara, CA, USA).

Article Title: A small molecule inhibitor of Nicotinamide N-methyltransferase for the treatment of metabolic disorders
Article Snippet: .. Samples (5 µL) were injected onto Kinetex HILIC (50 × 4.6 mm, 2.6 µm; Phenomenex, Torrance, CA, USA) column connected to Shimadzu VP (Shimadzu, Japan) LC system. .. The gradient mobile phase mixture of 0.2% formic acid and acetonitrile was delivered at a flow rate of 0.45 ml min-1 into the mass spectrometer electrospray ionization (ESI) chamber.

Article Title: Simultaneous Quantification of Free Cholesterol, Cholesteryl Esters, and Triglycerides without Ester Hydrolysis by UHPLC Separation and In-Source Collision Induced Dissociation Coupled MS/MS
Article Snippet: .. The column was a Kinetex HILIC 1.7 μm, 2.1 × 50 mm (Phenomenex, Torrance, CA, USA). ..

Article Title: Pleiotropic effects of apolipoprotein C3 on HDL functionality and adipose tissue metabolic activity [S]
Article Snippet: .. Briefly, lipids were separated on a Kinetex HILIC 150 × 2.1 mm, 2.6 μm column (Phenomenex, Torrance, CA) using a Prominence HPLC (Shimadzu). ..

Article Title: Apoptosis Induced by the Curcumin Analogue EF-24 Is Neither Mediated by Oxidative Stress-Related Mechanisms nor Affected by Expression of Main Drug Transporters ABCB1 and ABCG2 in Human Leukemia Cells
Article Snippet: .. A Kinetex HILIC, 2.6 μm, 150 × 2.1 mm column (Phenomenex, Torrance, CA, USA) and a guard Kinetex HILIC, 4.0 × 2.0 mm precolumn (Phenomenex, Torrance, CA, USA) were installed. ..

High Performance Liquid Chromatography:

Article Title: Pleiotropic effects of apolipoprotein C3 on HDL functionality and adipose tissue metabolic activity [S]
Article Snippet: .. Briefly, lipids were separated on a Kinetex HILIC 150 × 2.1 mm, 2.6 μm column (Phenomenex, Torrance, CA) using a Prominence HPLC (Shimadzu). ..

Injection:

Article Title: A small molecule inhibitor of Nicotinamide N-methyltransferase for the treatment of metabolic disorders
Article Snippet: .. Samples (5 µL) were injected onto Kinetex HILIC (50 × 4.6 mm, 2.6 µm; Phenomenex, Torrance, CA, USA) column connected to Shimadzu VP (Shimadzu, Japan) LC system. .. The gradient mobile phase mixture of 0.2% formic acid and acetonitrile was delivered at a flow rate of 0.45 ml min-1 into the mass spectrometer electrospray ionization (ESI) chamber.

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90
    Phenomenex kinetex hilic column
    Kinetex Hilic Column, supplied by Phenomenex, used in various techniques. Bioz Stars score: 90/100, based on 68 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/kinetex hilic column/product/Phenomenex
    Average 90 stars, based on 68 article reviews
    Price from $9.99 to $1999.99
    kinetex hilic column - by Bioz Stars, 2020-07
    90/100 stars
      Buy from Supplier

    Image Search Results