Structured Review

Phenomenex hilic
Hilic, supplied by Phenomenex, used in various techniques. Bioz Stars score: 92/100, based on 37 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hilic/product/Phenomenex
Average 92 stars, based on 37 article reviews
Price from $9.99 to $1999.99
hilic - by Bioz Stars, 2020-07
92/100 stars

Images

Related Articles

Hydrophilic Interaction Liquid Chromatography:

Article Title: Targeting Modified Lipids during Routine Lipidomics Analysis using HILIC and C30 Reverse Phase Liquid Chromatography coupled to Mass Spectrometry
Article Snippet: .. Analysis of the lipid mixture using HILIC or C30-RPLC The HILIC column (Luna 3 µm, 100 × 2 mm I.D., particle size: 3 µm, pore diameter: 200 Å) was purchased from Phenomenex (Torrance, CA, USA). ..

Article Title: Assays for determining heparan sulfate and heparin O-sulfotransferase activity and specificity
Article Snippet: .. The products were analyzed by HILIC using a 2.0 × 50 mm (Torrance, CA) The products were analyzed by HILIC using a 2.0 × 50 mm Luna HILIC column (Phenomenex, Torrance, CA) coupled to an electrospray ionization LTQ-Orbitrap XL FTMS (Thermo Fisher Scientific, San-Jose, CA). .. The mobile phase A was 5 mM ammonium acetate prepared with HPLC grade water.

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90
    Phenomenex luna hilic column
    ( A ) Total ion chromatography of <t>HILIC-FTMS</t> profiling of fully digested KS domain structure. ( B ) Composition analysis of <t>KSO</t> calculated by GlycResoft. The analytical error for each GAG was
    Luna Hilic Column, supplied by Phenomenex, used in various techniques. Bioz Stars score: 90/100, based on 62 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/luna hilic column/product/Phenomenex
    Average 90 stars, based on 62 article reviews
    Price from $9.99 to $1999.99
    luna hilic column - by Bioz Stars, 2020-07
    90/100 stars
      Buy from Supplier

    85
    Phenomenex hilic lc ms
    PCA-DA plots of the ccRCC <t>HILIC-LC–ESI–MS</t> after genetic algorithms (GA) feature selection.
    Hilic Lc Ms, supplied by Phenomenex, used in various techniques. Bioz Stars score: 85/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/hilic lc ms/product/Phenomenex
    Average 85 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    hilic lc ms - by Bioz Stars, 2020-07
    85/100 stars
      Buy from Supplier

    91
    Phenomenex hilic column
    Extracted ion chromatogram (XIC) of acylPG in corn roots obtained from ( a ) <t>HILIC</t> and ( b ) <t>C30-RPLC,</t> ( c ) HILIC-MS of total acylPG. Corresponding HRMS/MS spectrum of m/z 1029.76 obtained from ( d ) HILIC and ( e , f ) C30-RPLC. Structures of acylPG are inserted in the MS/MS spectra.
    Hilic Column, supplied by Phenomenex, used in various techniques. Bioz Stars score: 91/100, based on 21 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/hilic column/product/Phenomenex
    Average 91 stars, based on 21 article reviews
    Price from $9.99 to $1999.99
    hilic column - by Bioz Stars, 2020-07
    91/100 stars
      Buy from Supplier

    89
    Phenomenex hydrophilic interaction chromatography hilic
    Detection of arginine metabolites by LC/MS Extracted ion chromatograms of ADMA (A), D 7 ADMA(B), SDMA (C), D 6 SDMA (D), NMMA (E), arginine (F), 13 C 6 - arginine (G), citrulline (H) and 13 C 5 citrulline (I) are shown. <t>Hydrophilic</t> interaction chromatography (HILIC) of authentic compounds and their internal standards was performed using <t>Phenomenex</t> HILIC column with solvent 10mM ammonium acetate and 100% acetonitrile with 0.1% formic acid. The column was equilibrated with 95% solvent B and 5% solvent A initially. The gradient was: 95–15% solvent B over 8 min, 15% solvent B for 6 min, 15–95% solvent B for 1 min and then finally 95% solvent B for 10 min. The eluent was subjected electrospray ionization mass spectrometry (ESI/MS) and the analytes were detected in the multiple reaction monitoring mode (MRM). X axis is denotes time of elution during chromatographic run and the Y axis represents the ion intensity of the extracted ion chromatogram of the daughter ion following ESI of the analyte in the MRM mode. The MRM transitions that are followed for the individual analyte are depicted with each parent molecular ion to daughter fragment that was monitored.
    Hydrophilic Interaction Chromatography Hilic, supplied by Phenomenex, used in various techniques. Bioz Stars score: 89/100, based on 3 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/hydrophilic interaction chromatography hilic/product/Phenomenex
    Average 89 stars, based on 3 article reviews
    Price from $9.99 to $1999.99
    hydrophilic interaction chromatography hilic - by Bioz Stars, 2020-07
    89/100 stars
      Buy from Supplier

    Image Search Results


    ( A ) Total ion chromatography of HILIC-FTMS profiling of fully digested KS domain structure. ( B ) Composition analysis of KSO calculated by GlycResoft. The analytical error for each GAG was

    Journal: Marine Drugs

    Article Title: Structural Characterization and Interaction with RCA120 of a Highly Sulfated Keratan Sulfate from Blue Shark (Prionace glauca) Cartilage

    doi: 10.3390/md16040128

    Figure Lengend Snippet: ( A ) Total ion chromatography of HILIC-FTMS profiling of fully digested KS domain structure. ( B ) Composition analysis of KSO calculated by GlycResoft. The analytical error for each GAG was

    Article Snippet: The KSO were separated by a Luna HILIC column (150 × 2.00 mm, 3 μm, Phenomenex) at 25 °C.

    Techniques: Ion Chromatography, Hydrophilic Interaction Liquid Chromatography

    PCA-DA plots of the ccRCC HILIC-LC–ESI–MS after genetic algorithms (GA) feature selection.

    Journal: Metabolites

    Article Title: A Comprehensive Workflow of Mass Spectrometry-Based Untargeted Metabolomics in Cancer Metabolic Biomarker Discovery Using Human Plasma and Urine

    doi: 10.3390/metabo3030787

    Figure Lengend Snippet: PCA-DA plots of the ccRCC HILIC-LC–ESI–MS after genetic algorithms (GA) feature selection.

    Article Snippet: HILIC ESI-LC-MS For human blood plasma samples, HILIC-LC-MS was performed on a Luna HILIC Diol HPLC column (150 × 3 mM, 3 µM particle size, Phenomenex, Torrance, CA, USA).

    Techniques: Hydrophilic Interaction Liquid Chromatography, Mass Spectrometry, Selection

    A 3D PCA plot of results using HILIC-LC-ESI-MS.

    Journal: Metabolites

    Article Title: A Comprehensive Workflow of Mass Spectrometry-Based Untargeted Metabolomics in Cancer Metabolic Biomarker Discovery Using Human Plasma and Urine

    doi: 10.3390/metabo3030787

    Figure Lengend Snippet: A 3D PCA plot of results using HILIC-LC-ESI-MS.

    Article Snippet: HILIC ESI-LC-MS For human blood plasma samples, HILIC-LC-MS was performed on a Luna HILIC Diol HPLC column (150 × 3 mM, 3 µM particle size, Phenomenex, Torrance, CA, USA).

    Techniques: Hydrophilic Interaction Liquid Chromatography, Mass Spectrometry

    Extracted ion chromatogram (XIC) of acylPG in corn roots obtained from ( a ) HILIC and ( b ) C30-RPLC, ( c ) HILIC-MS of total acylPG. Corresponding HRMS/MS spectrum of m/z 1029.76 obtained from ( d ) HILIC and ( e , f ) C30-RPLC. Structures of acylPG are inserted in the MS/MS spectra.

    Journal: Scientific Reports

    Article Title: Targeting Modified Lipids during Routine Lipidomics Analysis using HILIC and C30 Reverse Phase Liquid Chromatography coupled to Mass Spectrometry

    doi: 10.1038/s41598-019-41556-9

    Figure Lengend Snippet: Extracted ion chromatogram (XIC) of acylPG in corn roots obtained from ( a ) HILIC and ( b ) C30-RPLC, ( c ) HILIC-MS of total acylPG. Corresponding HRMS/MS spectrum of m/z 1029.76 obtained from ( d ) HILIC and ( e , f ) C30-RPLC. Structures of acylPG are inserted in the MS/MS spectra.

    Article Snippet: Analysis of the lipid mixture using HILIC or C30-RPLC The HILIC column (Luna 3 µm, 100 × 2 mm I.D., particle size: 3 µm, pore diameter: 200 Å) was purchased from Phenomenex (Torrance, CA, USA).

    Techniques: Hydrophilic Interaction Liquid Chromatography, Mass Spectrometry

    UHPLC-MS chromatogram in negative ion mode of the standard lipid mixture obtained after ( a ) HILIC and ( b ) C30-RPLC. ( c ) HILIC-MS spectrum of PI eluted at 22.54 min, ( d ) C30-RPLC-MS spectrum showing PI, PG and DMPE eluted at 19.85 min. ( e , f ) MS/MS spectra of PI 18:0/20:4 from HILIC and C30RPLC, respectively.

    Journal: Scientific Reports

    Article Title: Targeting Modified Lipids during Routine Lipidomics Analysis using HILIC and C30 Reverse Phase Liquid Chromatography coupled to Mass Spectrometry

    doi: 10.1038/s41598-019-41556-9

    Figure Lengend Snippet: UHPLC-MS chromatogram in negative ion mode of the standard lipid mixture obtained after ( a ) HILIC and ( b ) C30-RPLC. ( c ) HILIC-MS spectrum of PI eluted at 22.54 min, ( d ) C30-RPLC-MS spectrum showing PI, PG and DMPE eluted at 19.85 min. ( e , f ) MS/MS spectra of PI 18:0/20:4 from HILIC and C30RPLC, respectively.

    Article Snippet: Analysis of the lipid mixture using HILIC or C30-RPLC The HILIC column (Luna 3 µm, 100 × 2 mm I.D., particle size: 3 µm, pore diameter: 200 Å) was purchased from Phenomenex (Torrance, CA, USA).

    Techniques: Mass Spectrometry, Hydrophilic Interaction Liquid Chromatography

    Detection of arginine metabolites by LC/MS Extracted ion chromatograms of ADMA (A), D 7 ADMA(B), SDMA (C), D 6 SDMA (D), NMMA (E), arginine (F), 13 C 6 - arginine (G), citrulline (H) and 13 C 5 citrulline (I) are shown. Hydrophilic interaction chromatography (HILIC) of authentic compounds and their internal standards was performed using Phenomenex HILIC column with solvent 10mM ammonium acetate and 100% acetonitrile with 0.1% formic acid. The column was equilibrated with 95% solvent B and 5% solvent A initially. The gradient was: 95–15% solvent B over 8 min, 15% solvent B for 6 min, 15–95% solvent B for 1 min and then finally 95% solvent B for 10 min. The eluent was subjected electrospray ionization mass spectrometry (ESI/MS) and the analytes were detected in the multiple reaction monitoring mode (MRM). X axis is denotes time of elution during chromatographic run and the Y axis represents the ion intensity of the extracted ion chromatogram of the daughter ion following ESI of the analyte in the MRM mode. The MRM transitions that are followed for the individual analyte are depicted with each parent molecular ion to daughter fragment that was monitored.

    Journal: Journal of proteomics & bioinformatics

    Article Title: Metabolomic Profiling of Arginine Metabolome Links Altered Methylation to Chronic Kidney Disease Accelerated Atherosclerosis

    doi: 10.4172/jpb.S14-001

    Figure Lengend Snippet: Detection of arginine metabolites by LC/MS Extracted ion chromatograms of ADMA (A), D 7 ADMA(B), SDMA (C), D 6 SDMA (D), NMMA (E), arginine (F), 13 C 6 - arginine (G), citrulline (H) and 13 C 5 citrulline (I) are shown. Hydrophilic interaction chromatography (HILIC) of authentic compounds and their internal standards was performed using Phenomenex HILIC column with solvent 10mM ammonium acetate and 100% acetonitrile with 0.1% formic acid. The column was equilibrated with 95% solvent B and 5% solvent A initially. The gradient was: 95–15% solvent B over 8 min, 15% solvent B for 6 min, 15–95% solvent B for 1 min and then finally 95% solvent B for 10 min. The eluent was subjected electrospray ionization mass spectrometry (ESI/MS) and the analytes were detected in the multiple reaction monitoring mode (MRM). X axis is denotes time of elution during chromatographic run and the Y axis represents the ion intensity of the extracted ion chromatogram of the daughter ion following ESI of the analyte in the MRM mode. The MRM transitions that are followed for the individual analyte are depicted with each parent molecular ion to daughter fragment that was monitored.

    Article Snippet: A hydrophilic interaction chromatography (HILIC) was performed utilizing Luna Phenomenex column (2.1 × 150mm, 3μm; Torrance, CA)) with an isocratic gradient of 85% acetonitrile with 20 mM ammonium acetate for 5 min at flow rate of 0.3 mL/min.

    Techniques: Liquid Chromatography with Mass Spectroscopy, Hydrophilic Interaction Liquid Chromatography, Mass Spectrometry