    Name:
    GeneAmp PCR System 9700 Extended Warranty
    Description:
    A 1 year Extended Warranty for your GeneAmp PCR System 9700 will add 1 year of warranty coverage to your existing manufacturer s warranty With this extended warranty your GeneAmp PCR System 9700 is covered by our Rapid Exchange Service protection should you encounter a problem with your instrument you call technical support and talk to one of our Certified Senior Technical Specialists There you will get the assistance you need to resolve many types of technical problems But if the instrument needs service we will send out a factory certified refurbished replacement instrument within 24 hours You should receive your replacement within 3 business days All you need to do is repackage the problem instrument and return it to us and we pay for shipping The service also includes full access to our Applications and Instrument Technical Support teams Applied Biosystems will ship a factory certified refurbished unit of the same instrument model covered by this service plan within 24 hours from the time that Applied Biosystems determines that a replacement instrument is required On site Planned maintenance PM remedial repairs and parts and computer hardware are not covered under this plan Your GeneAmp PCR System 9700 must be 5 years old or newer to qualify for this service and be in good working order at time of service plan purchase
    Catalog Number:
    zgexsc9700384w
    Price:
    None
    Applications:
    PCR|PCR & Real-Time PCR|Thermal Cyclers
    Category:
    Instruments and Equipment
    Buy from Supplier


    Structured Review

    Thermo Fisher geneamp pcr system 9700 384
    A 1 year Extended Warranty for your GeneAmp PCR System 9700 will add 1 year of warranty coverage to your existing manufacturer s warranty With this extended warranty your GeneAmp PCR System 9700 is covered by our Rapid Exchange Service protection should you encounter a problem with your instrument you call technical support and talk to one of our Certified Senior Technical Specialists There you will get the assistance you need to resolve many types of technical problems But if the instrument needs service we will send out a factory certified refurbished replacement instrument within 24 hours You should receive your replacement within 3 business days All you need to do is repackage the problem instrument and return it to us and we pay for shipping The service also includes full access to our Applications and Instrument Technical Support teams Applied Biosystems will ship a factory certified refurbished unit of the same instrument model covered by this service plan within 24 hours from the time that Applied Biosystems determines that a replacement instrument is required On site Planned maintenance PM remedial repairs and parts and computer hardware are not covered under this plan Your GeneAmp PCR System 9700 must be 5 years old or newer to qualify for this service and be in good working order at time of service plan purchase
    https://www.bioz.com/result/geneamp pcr system 9700 384/product/Thermo Fisher
    Average 99 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    geneamp pcr system 9700 384 - by Bioz Stars, 2020-07
    99/100 stars

    Related Products / Commonly Used Together

    cdna library

    Images

    Related Articles

    Amplification:

    Article Title: Assessment of MagNA Pure LC Extraction System for Detection of Human Papillomavirus (HPV) DNA in PreservCyt Samples by the Roche AMPLICOR and LINEAR ARRAY HPV Tests
    Article Snippet: .. Amplification was performed in a GeneAmp PCR System 9700 with gold block (Applied Biosystems, Foster City, CA) using the following parameters: 2 min at 50°C and 9 min at 95°C; followed by 40 cycles of: 95°C for 30 s, 54°C for 45 s, and 72°C for 30 s; followed by a final hold at 72°C. .. PCR amplicons were immediately denatured by the addition of 100 μl of AMPLICOR denaturation solution (Roche Molecular Systems) and incubation at room temperature for 10 min. A dual 96-microwell plate system for the simultaneous detection of β-globin and HPV was used for amplicon-to-probe hybridization.

    Fluorescence:

    Article Title: The Impact of Genetic Variations in ADORA2A in the Association between Caffeine Consumption and Sleep
    Article Snippet: .. PCR was performed on GeneAmp PCR System 9700, and a 7900HT system with SDS software version 2.4 (Applied Biosystems, Foster City, USA) was used for fluorescence detection and allelic discrimination. .. A check by Sanger sequencing of PCR products was carried out for rs5751876 because the ADORA2A gene includes many SNPs in this region.

    Blocking Assay:

    Article Title: Study on the association between IL-1β, IL-8 and IL-10 gene polymorphisms and risk of coronary artery disease
    Article Snippet: .. Briefly PCR was performed in a final volume of 5 μL reaction solution with 50 ng genomic DNA template using, GeneAmp® PCR System 9700 with Dual 384-Well Sample Block Module (Applied Biosystems, Carlsbad, USA). .. The MassARRAY Analyzer Compact with ACQUAIRE Module (Sequenom) acquired spectra from the SpectroCHIP, and spectral data were automatically processed and saved to the MassARRAY database ( ).

    Article Title: Assessment of MagNA Pure LC Extraction System for Detection of Human Papillomavirus (HPV) DNA in PreservCyt Samples by the Roche AMPLICOR and LINEAR ARRAY HPV Tests
    Article Snippet: .. Amplification was performed in a GeneAmp PCR System 9700 with gold block (Applied Biosystems, Foster City, CA) using the following parameters: 2 min at 50°C and 9 min at 95°C; followed by 40 cycles of: 95°C for 30 s, 54°C for 45 s, and 72°C for 30 s; followed by a final hold at 72°C. .. PCR amplicons were immediately denatured by the addition of 100 μl of AMPLICOR denaturation solution (Roche Molecular Systems) and incubation at room temperature for 10 min. A dual 96-microwell plate system for the simultaneous detection of β-globin and HPV was used for amplicon-to-probe hybridization.

    Real-time Polymerase Chain Reaction:

    Article Title: The Role of TLR4 Activation in Photoreceptor Mitochondrial Oxidative Stress
    Article Snippet: .. Quantitative PCR (qPCR) was performed (GeneAmp PCR system 9700 with the GeneAmp XL PCR kit; Applied Biosystems, Foster City, CA). ..

    Polymerase Chain Reaction:

    Article Title: Study on the association between IL-1β, IL-8 and IL-10 gene polymorphisms and risk of coronary artery disease
    Article Snippet: .. Briefly PCR was performed in a final volume of 5 μL reaction solution with 50 ng genomic DNA template using, GeneAmp® PCR System 9700 with Dual 384-Well Sample Block Module (Applied Biosystems, Carlsbad, USA). .. The MassARRAY Analyzer Compact with ACQUAIRE Module (Sequenom) acquired spectra from the SpectroCHIP, and spectral data were automatically processed and saved to the MassARRAY database ( ).

    Article Title: A high-throughput Sanger strategy for human mitochondrial genome sequencing
    Article Snippet: .. Thermal cycling steps in this protocol have been performed with equal success on a variety of 96-well machines in our laboratory, including GeneAmp® PCR System 9700 and Veriti® instruments (Life Technologies, Applied Biosystems), TRobot thermal cyclers (Biometra GmbH, Goettingen, Germany), and PTC-0200 DNA Engine instruments (MJ Research, Inc., Waltham, MA). ..

    Article Title: The Role of TLR4 Activation in Photoreceptor Mitochondrial Oxidative Stress
    Article Snippet: .. Quantitative PCR (qPCR) was performed (GeneAmp PCR system 9700 with the GeneAmp XL PCR kit; Applied Biosystems, Foster City, CA). ..

    Article Title: Photothermal effects of NaYF4:Yb,Er@PE3@Fe3O4 superparamagnetic nanoprobes in the treatment of melanoma
    Article Snippet: .. Benchtop PCR was performed on a GeneAmp PCR System 9700 machine in a 50 µl reaction volume: 1× PCR buffer (+Mg2+ ), 0.2 mM dNTP, 0.2 µM primers, 50 ng of template cDNA, and 0.5 µL of Platinum TaqDNA polymerase (Invitrogen). ..

    Article Title: Assessment of MagNA Pure LC Extraction System for Detection of Human Papillomavirus (HPV) DNA in PreservCyt Samples by the Roche AMPLICOR and LINEAR ARRAY HPV Tests
    Article Snippet: .. Amplification was performed in a GeneAmp PCR System 9700 with gold block (Applied Biosystems, Foster City, CA) using the following parameters: 2 min at 50°C and 9 min at 95°C; followed by 40 cycles of: 95°C for 30 s, 54°C for 45 s, and 72°C for 30 s; followed by a final hold at 72°C. .. PCR amplicons were immediately denatured by the addition of 100 μl of AMPLICOR denaturation solution (Roche Molecular Systems) and incubation at room temperature for 10 min. A dual 96-microwell plate system for the simultaneous detection of β-globin and HPV was used for amplicon-to-probe hybridization.

    Article Title: SOCS-3 is frequently silenced by hypermethylation and suppresses cell growth in human lung cancer
    Article Snippet: .. RT-PCR was performed in the GeneAmp PCR system 9700 by using the One-Step RT-PCR Kit from Life Technologies, according to the manufacturer's protocol. .. Primers for RT-PCR were obtained from Operon Technologies (Alameda, CA).

    Article Title: Analytical validation of real-time quantitative PCR assays for optimum diagnosis of vivax malaria
    Article Snippet: .. To this end, the same sample and protocol described for LoD were used., Repeatability was analysed among triplicates of an assay (within-run), whereas reproducibility was determined in three repeated day assays (between-runs), between operators in a single-day assay and between two GeneAmp™ 9700 PCR Systems and one Veriti™ fast Thermal Cycler (both from Applied Biosystems). ..

    Article Title: The Impact of Genetic Variations in ADORA2A in the Association between Caffeine Consumption and Sleep
    Article Snippet: .. PCR was performed on GeneAmp PCR System 9700, and a 7900HT system with SDS software version 2.4 (Applied Biosystems, Foster City, USA) was used for fluorescence detection and allelic discrimination. .. A check by Sanger sequencing of PCR products was carried out for rs5751876 because the ADORA2A gene includes many SNPs in this region.

    Reverse Transcription Polymerase Chain Reaction:

    Article Title: SOCS-3 is frequently silenced by hypermethylation and suppresses cell growth in human lung cancer
    Article Snippet: .. RT-PCR was performed in the GeneAmp PCR system 9700 by using the One-Step RT-PCR Kit from Life Technologies, according to the manufacturer's protocol. .. Primers for RT-PCR were obtained from Operon Technologies (Alameda, CA).

    Software:

    Article Title: The Impact of Genetic Variations in ADORA2A in the Association between Caffeine Consumption and Sleep
    Article Snippet: .. PCR was performed on GeneAmp PCR System 9700, and a 7900HT system with SDS software version 2.4 (Applied Biosystems, Foster City, USA) was used for fluorescence detection and allelic discrimination. .. A check by Sanger sequencing of PCR products was carried out for rs5751876 because the ADORA2A gene includes many SNPs in this region.