Structured Review

Agilent technologies gc ms detection
Gc Ms Detection, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 4 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/gc ms detection/product/Agilent technologies
Average 90 stars, based on 4 article reviews
Price from $9.99 to $1999.99
gc ms detection - by Bioz Stars, 2020-08
90/100 stars

Images

Related Articles

Gas Chromatography-Mass Spectrometry:

Article Title: Reducing Quorum Sensing-Mediated Virulence Factor Expression and Biofilm Formation in Hafnia alvei by Using the Potential Quorum Sensing Inhibitor L-Carvone
Article Snippet: .. GC-MS Detection The AHL samples of H. alvei were further analyzed by GC-MS (7890N/5975, Agilent, United States), according to the method described by . .. A HP-5 MS capillary column (30 m length × 0.25 mm internal diameter × 0.25 μm film thickness) was used for the chromatographic separation of the AHLs.

Article Title: PE11, a PE/PPE family protein of Mycobacterium tuberculosis is involved in cell wall remodeling and virulence
Article Snippet: .. The GC/MS detection was performed with Agilent 6890 N gas chromatograph connected to Agilent 5973 mass selective detector at 70 eV (m /z 50–800; source at 230 °C and quadruple at 150 °C) in the EI mode with a HP-1 ms capillary column (30 m × 0.25 mm I.D. .. The carrier gas, helium was used at a flow rate of 1.0 ml/min.

Article Title: Probiotic Mixture of Lactobacillus plantarum Strains Improves Lipid Metabolism and Gut Microbiota Structure in High Fat Diet-Fed Mice
Article Snippet: .. GC-MS detection was performed using an Agilent 7890 gas chromatography mass spectrometer equipped with an Agilent HP-FFAP capillary column (30 m × 250 μm × 0.25 μm, J & W Scientific, Folsom, CA, United States). .. Acetic acid, butyric acid, propionic acid, valeric acid (Sigma, St. Louis, MO, United States) were used as the standards.

Article Title: Malate enhances survival of zebrafish against Vibrio alginolyticus infection in the same manner as taurine
Article Snippet: .. GC-MS detection The derivatized sample of 1 μL was injected into an HP-5 MS column (Agilent Technologies, 30 m × 250 μm × i.d. .. 0.25 μm) using splitless injection and analysis was carried out by Agilent 7890A GC equipped with an Agilent 5975 C VL MSD detector (Agilent Technologies).

Article Title: A bimodular PKS platform that expands the biological design space
Article Snippet: .. GC-MS detection of 4,6-dimethyl heptanone Electron ionization GC/MS analysis was performed on a G3950A-9000 GC (Agilent) using a J & W HP-5ms Ultra Inert Intuvo GC column module (15 m length, 0.25 mm inner diameter, 0.25 μm film thickness). .. The GC was coupled to a mass selective detector (Agilent 5977B MSD) and an autosampler (Model 7693 Agilent).

Article Title: Rapid Accumulation of Total Lipid in Rhizoclonium africanum Kutzing as Biodiesel Feedstock under Nutrient Limitations and the Associated Changes at Cellular Level
Article Snippet: .. Gas Chromatography-Mass Spectrometry (GC-MS) The FAME was subjected to GC-MS detection performed with Agilent 6890N Gas Chromatograph connected to Agilent 5973 Mass Selective Detector at 70 eV (m /z 50–550; source at 230°C and quadruple at 150°C) in the electron impact mode with a HP-5 ms capillary column (30 m × 0.25 mm i.d. .. The carrier gas, helium, was used at a flow rate of 1.0 mL/min.

Injection:

Article Title: Malate enhances survival of zebrafish against Vibrio alginolyticus infection in the same manner as taurine
Article Snippet: .. GC-MS detection The derivatized sample of 1 μL was injected into an HP-5 MS column (Agilent Technologies, 30 m × 250 μm × i.d. .. 0.25 μm) using splitless injection and analysis was carried out by Agilent 7890A GC equipped with an Agilent 5975 C VL MSD detector (Agilent Technologies).

Gas Chromatography:

Article Title: Probiotic Mixture of Lactobacillus plantarum Strains Improves Lipid Metabolism and Gut Microbiota Structure in High Fat Diet-Fed Mice
Article Snippet: .. GC-MS detection was performed using an Agilent 7890 gas chromatography mass spectrometer equipped with an Agilent HP-FFAP capillary column (30 m × 250 μm × 0.25 μm, J & W Scientific, Folsom, CA, United States). .. Acetic acid, butyric acid, propionic acid, valeric acid (Sigma, St. Louis, MO, United States) were used as the standards.

Mass Spectrometry:

Article Title: PE11, a PE/PPE family protein of Mycobacterium tuberculosis is involved in cell wall remodeling and virulence
Article Snippet: .. The GC/MS detection was performed with Agilent 6890 N gas chromatograph connected to Agilent 5973 mass selective detector at 70 eV (m /z 50–800; source at 230 °C and quadruple at 150 °C) in the EI mode with a HP-1 ms capillary column (30 m × 0.25 mm I.D. .. The carrier gas, helium was used at a flow rate of 1.0 ml/min.

Article Title: Probiotic Mixture of Lactobacillus plantarum Strains Improves Lipid Metabolism and Gut Microbiota Structure in High Fat Diet-Fed Mice
Article Snippet: .. GC-MS detection was performed using an Agilent 7890 gas chromatography mass spectrometer equipped with an Agilent HP-FFAP capillary column (30 m × 250 μm × 0.25 μm, J & W Scientific, Folsom, CA, United States). .. Acetic acid, butyric acid, propionic acid, valeric acid (Sigma, St. Louis, MO, United States) were used as the standards.

Article Title: Rapid Accumulation of Total Lipid in Rhizoclonium africanum Kutzing as Biodiesel Feedstock under Nutrient Limitations and the Associated Changes at Cellular Level
Article Snippet: .. Gas Chromatography-Mass Spectrometry (GC-MS) The FAME was subjected to GC-MS detection performed with Agilent 6890N Gas Chromatograph connected to Agilent 5973 Mass Selective Detector at 70 eV (m /z 50–550; source at 230°C and quadruple at 150°C) in the electron impact mode with a HP-5 ms capillary column (30 m × 0.25 mm i.d. .. The carrier gas, helium, was used at a flow rate of 1.0 mL/min.

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 91
    Agilent technologies mass spectrometry detector gc msd
    The <t>GC-MSD</t> and <t>GC-FID</t> (insert) chromatograms of thyme oil.
    Mass Spectrometry Detector Gc Msd, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/mass spectrometry detector gc msd/product/Agilent technologies
    Average 91 stars, based on 1 article reviews
    Price from $9.99 to $1999.99
    mass spectrometry detector gc msd - by Bioz Stars, 2020-08
    91/100 stars
      Buy from Supplier

    89
    Agilent technologies gc ms sim
    ( A ) Salkowski test for indole-3-acetic acid <t>(IAA)</t> determination and the amount of IAA produced by CS51 by <t>GC-MS/SIM</t> spectrometry analysis, ( B ) growth promoting effect of CS51 inoculation on Waito-C (gibberellins (GA) deficient) rice plants and the amount of different GAs produced by CS51 by GC-MS/SIM spectrometry analysis, ( C ) growth pattern of CS51 in 1 mM and 10 mM Zn-supplemented, Cu-supplemented, and Cd-supplemented media, ( D ) phosphate-solubilizing activity of CS51 on national botanical research institute’s phosphate (NBRIP) growth media plates, and incubated for 7 days at 30°C. The clarification halos show P solubilization and the maximum size of the clarification halos was reached after 72 values given are means of three replicates. Error bars indicate standard deviations.
    Gc Ms Sim, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 89/100, based on 187 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/gc ms sim/product/Agilent technologies
    Average 89 stars, based on 187 article reviews
    Price from $9.99 to $1999.99
    gc ms sim - by Bioz Stars, 2020-08
    89/100 stars
      Buy from Supplier

    Image Search Results


    The GC-MSD and GC-FID (insert) chromatograms of thyme oil.

    Journal: Materials

    Article Title: Comparative Analysis of the Composition and Active Property Evaluation of Certain Essential Oils to Assess their Potential Applications in Active Food Packaging

    doi: 10.3390/ma10010045

    Figure Lengend Snippet: The GC-MSD and GC-FID (insert) chromatograms of thyme oil.

    Article Snippet: Gas Chromatography-Mass Spectrometry Detector and Flame-Ionized Detector Analysis (GC-MSD/FID) The essential oils were characterized by gas chromatography coupled with mass spectrometry detector (GC-MSD) for qualitative analysis and, with a flame ionized detector (GC-FID) (Agilent, Santa Clara, CA, USA), quantitative analysis.

    Techniques:

    The GC-MSD and GC-FID (insert) chromatograms of tea tree oil.

    Journal: Materials

    Article Title: Comparative Analysis of the Composition and Active Property Evaluation of Certain Essential Oils to Assess their Potential Applications in Active Food Packaging

    doi: 10.3390/ma10010045

    Figure Lengend Snippet: The GC-MSD and GC-FID (insert) chromatograms of tea tree oil.

    Article Snippet: Gas Chromatography-Mass Spectrometry Detector and Flame-Ionized Detector Analysis (GC-MSD/FID) The essential oils were characterized by gas chromatography coupled with mass spectrometry detector (GC-MSD) for qualitative analysis and, with a flame ionized detector (GC-FID) (Agilent, Santa Clara, CA, USA), quantitative analysis.

    Techniques:

    The GC-MSD and GC-FID (insert) chromatograms of clove oil.

    Journal: Materials

    Article Title: Comparative Analysis of the Composition and Active Property Evaluation of Certain Essential Oils to Assess their Potential Applications in Active Food Packaging

    doi: 10.3390/ma10010045

    Figure Lengend Snippet: The GC-MSD and GC-FID (insert) chromatograms of clove oil.

    Article Snippet: Gas Chromatography-Mass Spectrometry Detector and Flame-Ionized Detector Analysis (GC-MSD/FID) The essential oils were characterized by gas chromatography coupled with mass spectrometry detector (GC-MSD) for qualitative analysis and, with a flame ionized detector (GC-FID) (Agilent, Santa Clara, CA, USA), quantitative analysis.

    Techniques:

    The GC-MSD and GC-FID (insert) chromatograms of rosemary oil.

    Journal: Materials

    Article Title: Comparative Analysis of the Composition and Active Property Evaluation of Certain Essential Oils to Assess their Potential Applications in Active Food Packaging

    doi: 10.3390/ma10010045

    Figure Lengend Snippet: The GC-MSD and GC-FID (insert) chromatograms of rosemary oil.

    Article Snippet: Gas Chromatography-Mass Spectrometry Detector and Flame-Ionized Detector Analysis (GC-MSD/FID) The essential oils were characterized by gas chromatography coupled with mass spectrometry detector (GC-MSD) for qualitative analysis and, with a flame ionized detector (GC-FID) (Agilent, Santa Clara, CA, USA), quantitative analysis.

    Techniques:

    ( A ) Salkowski test for indole-3-acetic acid (IAA) determination and the amount of IAA produced by CS51 by GC-MS/SIM spectrometry analysis, ( B ) growth promoting effect of CS51 inoculation on Waito-C (gibberellins (GA) deficient) rice plants and the amount of different GAs produced by CS51 by GC-MS/SIM spectrometry analysis, ( C ) growth pattern of CS51 in 1 mM and 10 mM Zn-supplemented, Cu-supplemented, and Cd-supplemented media, ( D ) phosphate-solubilizing activity of CS51 on national botanical research institute’s phosphate (NBRIP) growth media plates, and incubated for 7 days at 30°C. The clarification halos show P solubilization and the maximum size of the clarification halos was reached after 72 values given are means of three replicates. Error bars indicate standard deviations.

    Journal: Microorganisms

    Article Title: Complete Genome Sequence of Pseudomonas psychrotolerans CS51, a Plant Growth-Promoting Bacterium, Under Heavy Metal Stress Conditions

    doi: 10.3390/microorganisms8030382

    Figure Lengend Snippet: ( A ) Salkowski test for indole-3-acetic acid (IAA) determination and the amount of IAA produced by CS51 by GC-MS/SIM spectrometry analysis, ( B ) growth promoting effect of CS51 inoculation on Waito-C (gibberellins (GA) deficient) rice plants and the amount of different GAs produced by CS51 by GC-MS/SIM spectrometry analysis, ( C ) growth pattern of CS51 in 1 mM and 10 mM Zn-supplemented, Cu-supplemented, and Cd-supplemented media, ( D ) phosphate-solubilizing activity of CS51 on national botanical research institute’s phosphate (NBRIP) growth media plates, and incubated for 7 days at 30°C. The clarification halos show P solubilization and the maximum size of the clarification halos was reached after 72 values given are means of three replicates. Error bars indicate standard deviations.

    Article Snippet: The IAA in bacterial cell-free cultures (5 mL) was quantified by GC-MS/SIM (6890 N Network GC System and 5973 Network Mass Selective Detector; Agilent Technologies, Palo Alto, CA, USA) as described previously [ ].

    Techniques: Produced, Gas Chromatography-Mass Spectrometry, Activity Assay, Incubation, Clarification Assay