Review



noise gold ecg probe  (World Precision Instruments)


Bioz Verified Symbol World Precision Instruments is a verified supplier
Bioz Manufacturer Symbol World Precision Instruments manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 94

    Structured Review

    World Precision Instruments noise gold ecg probe

    Noise Gold Ecg Probe, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ecg-probe/ECG+Probe/bio_rxiv__2024__04__17__589909-281-17-11
    Average 94 stars, based on 1 article reviews
    noise gold ecg probe - by Bioz Stars, 2026-11
    94/100 stars

    Images

    1) Product Images from "Loss of developmentally derived Irf8+ macrophages promotes hyperinnervation and arrhythmia in the adult zebrafish heart"

    Article Title: Loss of developmentally derived Irf8+ macrophages promotes hyperinnervation and arrhythmia in the adult zebrafish heart

    Journal: bioRxiv

    doi: 10.1101/2024.04.17.589909


    Figure Legend Snippet:

    Techniques Used:

    (A) Cartoon depiction of the rack-compatible swim tunnel with metered flow. Following a 5-minute acclimation period within the tunnel, 12 mpf zebrafish were subjected to increasing flow rate intervals for a total of 1 hour. (B) Cartoon depiction of an ECG recording and a representative ECG trace from an anesthetized fish placed ventral-side up in a sponge surrounded by anesthesia solution. (C) Representative ECG traces for wild type and irf8 mutant zebrafish following the swim assay. Black arrows indicate unique electrical disturbances occurring above any baseline noise. (D) Percentage of fish with an abnormal electrical event during the ECG recording. Male n = 7 per genotype, ****p < 0.0001. Female n = 4-8 per genotype, ****p < 0.0001. Fisher’s exact test. (E) Categorization of ECG abnormalities observed throughout all wild type and irf8 mutant fish.
    Figure Legend Snippet: (A) Cartoon depiction of the rack-compatible swim tunnel with metered flow. Following a 5-minute acclimation period within the tunnel, 12 mpf zebrafish were subjected to increasing flow rate intervals for a total of 1 hour. (B) Cartoon depiction of an ECG recording and a representative ECG trace from an anesthetized fish placed ventral-side up in a sponge surrounded by anesthesia solution. (C) Representative ECG traces for wild type and irf8 mutant zebrafish following the swim assay. Black arrows indicate unique electrical disturbances occurring above any baseline noise. (D) Percentage of fish with an abnormal electrical event during the ECG recording. Male n = 7 per genotype, ****p < 0.0001. Female n = 4-8 per genotype, ****p < 0.0001. Fisher’s exact test. (E) Categorization of ECG abnormalities observed throughout all wild type and irf8 mutant fish.

    Techniques Used: Mutagenesis


    Figure Legend Snippet:

    Techniques Used:

    (A) Cartoon depiction of an adult zebrafish undergoing an echocardiogram with the transducer in the long-axis (LAX) position. Echocardiograms were performed on unchallenged fish. (B) Cartoon of an adult zebrafish heart from the perspective of the echocardiography recording, denoting the atrium (A), atrioventricular (AV) valve, ventriculobulbar (VB) valve, and bulbus arteriosus (BA). The boxes around the AV valve and VB valve depict the gating strategies to determine inward flow and outward flow of blood from the ventricle. (C) Still image from an adult zebrafish echocardiography recording with the ventricle and bulbus arteriosus outlined in red. (D) Representative echocardiogram trace gating on the AV valve with the early filling (E) wave, late filling (A) wave, diastasis time, isovolumic contraction time (IVCT), aortic ejection time (AET), and isovolumic relaxation time (IVRT) labeled. (E-G) Quantifications of IVRT (E), AET (F), and pressure within the VB valve (G) in male and female wild type and irf8 mutant fish at 6 and 12 mpf. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Each point represents individual beats per fish. 8-10 beats were analyzed per fish. *p < 0.05; **p < 0.01; ***p < 0.001; ****p < 0.0001. (H) Quantification of heart in male and female wild type and irf8 mutants. (I) Representative echocardiogram traces from a wild type and irf8 mutant recording. (J-M) Quantification of diastasis time in wild type males (J) and females (K) at 6 mpf and 12 mpf, as well as diastasis time in irf8 mutant males (L) and females (M) at 6 mpf and 12 mpf. A Gaussian distribution was created by analyzing 8 beats per sample and grouping diastasis duration in defined increments. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Horizontal bars represent the range of diastasis duration. (N-O) 95% confidence interval of the average diastasis time durations in wild type (gray) and irf8 mutant (blue) males (N) and females (O).
    Figure Legend Snippet: (A) Cartoon depiction of an adult zebrafish undergoing an echocardiogram with the transducer in the long-axis (LAX) position. Echocardiograms were performed on unchallenged fish. (B) Cartoon of an adult zebrafish heart from the perspective of the echocardiography recording, denoting the atrium (A), atrioventricular (AV) valve, ventriculobulbar (VB) valve, and bulbus arteriosus (BA). The boxes around the AV valve and VB valve depict the gating strategies to determine inward flow and outward flow of blood from the ventricle. (C) Still image from an adult zebrafish echocardiography recording with the ventricle and bulbus arteriosus outlined in red. (D) Representative echocardiogram trace gating on the AV valve with the early filling (E) wave, late filling (A) wave, diastasis time, isovolumic contraction time (IVCT), aortic ejection time (AET), and isovolumic relaxation time (IVRT) labeled. (E-G) Quantifications of IVRT (E), AET (F), and pressure within the VB valve (G) in male and female wild type and irf8 mutant fish at 6 and 12 mpf. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Each point represents individual beats per fish. 8-10 beats were analyzed per fish. *p < 0.05; **p < 0.01; ***p < 0.001; ****p < 0.0001. (H) Quantification of heart in male and female wild type and irf8 mutants. (I) Representative echocardiogram traces from a wild type and irf8 mutant recording. (J-M) Quantification of diastasis time in wild type males (J) and females (K) at 6 mpf and 12 mpf, as well as diastasis time in irf8 mutant males (L) and females (M) at 6 mpf and 12 mpf. A Gaussian distribution was created by analyzing 8 beats per sample and grouping diastasis duration in defined increments. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Horizontal bars represent the range of diastasis duration. (N-O) 95% confidence interval of the average diastasis time durations in wild type (gray) and irf8 mutant (blue) males (N) and females (O).

    Techniques Used: Labeling, Mutagenesis

    Related Articles

    Amplification:

    Article Title: Vagus nerve stimulation to treat inflammatory bowel disease: a chronic, preclinical safety study in sheep
    Article Snippet: Sophie C Payne1,2, Owen Burns1, Martin Stebbing2,3, Ross Thomas1, Angel de Silva1, Alicia Sedo3, Frank Weissenborn3, Tomoko Hyakumura1, Mario Huynh1, Clive N May2,3, Richard A Williams2,4, John B Furness2,3, James B Fallon1,2 & Robert K Shepherd*,1,2 1Bionics Institute, Melbourne, Australia 2Department of Medical Bionics, The University of Melbourne, Melbourne, Australia 3Florey Institute of Neuroscience & Mental Health, Melbourne, Australia 4Department of Anatomical Pathology, St. Vincent’s Hospital, Melbourne, Australia *Author for correspondence: [email protected]

    Software:

    Article Title: Vagus nerve stimulation to treat inflammatory bowel disease: a chronic, preclinical safety study in sheep
    Article Snippet: Sophie C Payne1,2, Owen Burns1, Martin Stebbing2,3, Ross Thomas1, Angel de Silva1, Alicia Sedo3, Frank Weissenborn3, Tomoko Hyakumura1, Mario Huynh1, Clive N May2,3, Richard A Williams2,4, John B Furness2,3, James B Fallon1,2 & Robert K Shepherd*,1,2 1Bionics Institute, Melbourne, Australia 2Department of Medical Bionics, The University of Melbourne, Melbourne, Australia 3Florey Institute of Neuroscience & Mental Health, Melbourne, Australia 4Department of Anatomical Pathology, St. Vincent’s Hospital, Melbourne, Australia *Author for correspondence: [email protected]



    Similar Products

    94
    World Precision Instruments noise gold ecg probe

    Noise Gold Ecg Probe, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ecg-probe/ECG+Probe/bio_rxiv__2024__04__17__589909-281-17-11
    Average 94 stars, based on 1 article reviews
    noise gold ecg probe - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    90
    Philips Healthcare 2.3-3.5 mhz transducer probe with simultaneous ecg recording

    2.3 3.5 Mhz Transducer Probe With Simultaneous Ecg Recording, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ecg-probe/2+3+3+5+mhz+transducer+probe+with+simultaneous+ecg+recording/pm37671520-55-21-13
    Average 90 stars, based on 1 article reviews
    2.3-3.5 mhz transducer probe with simultaneous ecg recording - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    ADInstruments needle probe three-lead ecg

    Needle Probe Three Lead Ecg, supplied by ADInstruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ecg-probe/needle+probe+three+lead+ecg/pm37055107-67-3-7
    Average 90 stars, based on 1 article reviews
    needle probe three-lead ecg - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Canon inc ultrasonographic machine equipped with a 3–6 mhz sector probe and simultaneous ecg recording

    Ultrasonographic Machine Equipped With A 3–6 Mhz Sector Probe And Simultaneous Ecg Recording, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ecg-probe/ultrasonographic+machine+equipped+with+a+3+6+mhz+sector+probe+and+simultaneous+ecg+recording/pmc08692204-128-25-29
    Average 90 stars, based on 1 article reviews
    ultrasonographic machine equipped with a 3–6 mhz sector probe and simultaneous ecg recording - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    CamNtech Ltd ecg probe and amplifier interface actiheart 4

    Ecg Probe And Amplifier Interface Actiheart 4, supplied by CamNtech Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ecg-probe/ecg+probe+and+amplifier+interface+actiheart+4/pmc08476579-98-17-19
    Average 90 stars, based on 1 article reviews
    ecg probe and amplifier interface actiheart 4 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    SA Instruments rectal probe, respiration rate and ecg evaluation via the sa instruments platform

    Rectal Probe, Respiration Rate And Ecg Evaluation Via The Sa Instruments Platform, supplied by SA Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ecg-probe/rectal+probe++respiration+rate+and+ecg+evaluation+via+the+sa+instruments+platform/pmc08405807-364-8-16
    Average 90 stars, based on 1 article reviews
    rectal probe, respiration rate and ecg evaluation via the sa instruments platform - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    ADInstruments needle probe electrocardiography (ecg; animal bio amp)

    Needle Probe Electrocardiography (Ecg; Animal Bio Amp), supplied by ADInstruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ecg-probe/needle+probe+electrocardiography++ecg++animal+bio+amp+/ppr0311589-76-0-7
    Average 90 stars, based on 1 article reviews
    needle probe electrocardiography (ecg; animal bio amp) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Canon inc ultrasonographic machine with a 3 to 6 mhz sector probe and simultaneous ecg recording artida

    Ultrasonographic Machine With A 3 To 6 Mhz Sector Probe And Simultaneous Ecg Recording Artida, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ecg-probe/ultrasonographic+machine+with+a+3+to+6+mhz+sector+probe+and+simultaneous+ecg+recording+artida/pmc07848320-73-12-27
    Average 90 stars, based on 1 article reviews
    ultrasonographic machine with a 3 to 6 mhz sector probe and simultaneous ecg recording artida - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    ADInstruments power lab with ecg probe

    Power Lab With Ecg Probe, supplied by ADInstruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ecg-probe/power+lab+with+ecg+probe/pm31207272-46-16-18
    Average 90 stars, based on 1 article reviews
    power lab with ecg probe - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Philips Healthcare ecg-gated echocardiograph ie33 with x7-2t probe

    Ecg Gated Echocardiograph Ie33 With X7 2t Probe, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ecg-probe/ie33/10__1080_slash_24748706__2019__1686555-37-42-47
    Average 90 stars, based on 1 article reviews
    ecg-gated echocardiograph ie33 with x7-2t probe - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Journal: bioRxiv

    Article Title: Loss of developmentally derived Irf8+ macrophages promotes hyperinnervation and arrhythmia in the adult zebrafish heart

    doi: 10.1101/2024.04.17.589909

    Figure Lengend Snippet:

    Article Snippet: To record electrical impulses, we used the CardioPhys TM ECG system (World Precision Instruments), which included a low-noise gold ECG probe, micromanipulator, bio-amplifier and ground electrode, in combination with the PowerLab 2/26 data acquisition unit (ADInstruments, PL2602).

    Techniques:

    (A) Cartoon depiction of the rack-compatible swim tunnel with metered flow. Following a 5-minute acclimation period within the tunnel, 12 mpf zebrafish were subjected to increasing flow rate intervals for a total of 1 hour. (B) Cartoon depiction of an ECG recording and a representative ECG trace from an anesthetized fish placed ventral-side up in a sponge surrounded by anesthesia solution. (C) Representative ECG traces for wild type and irf8 mutant zebrafish following the swim assay. Black arrows indicate unique electrical disturbances occurring above any baseline noise. (D) Percentage of fish with an abnormal electrical event during the ECG recording. Male n = 7 per genotype, ****p < 0.0001. Female n = 4-8 per genotype, ****p < 0.0001. Fisher’s exact test. (E) Categorization of ECG abnormalities observed throughout all wild type and irf8 mutant fish.

    Journal: bioRxiv

    Article Title: Loss of developmentally derived Irf8+ macrophages promotes hyperinnervation and arrhythmia in the adult zebrafish heart

    doi: 10.1101/2024.04.17.589909

    Figure Lengend Snippet: (A) Cartoon depiction of the rack-compatible swim tunnel with metered flow. Following a 5-minute acclimation period within the tunnel, 12 mpf zebrafish were subjected to increasing flow rate intervals for a total of 1 hour. (B) Cartoon depiction of an ECG recording and a representative ECG trace from an anesthetized fish placed ventral-side up in a sponge surrounded by anesthesia solution. (C) Representative ECG traces for wild type and irf8 mutant zebrafish following the swim assay. Black arrows indicate unique electrical disturbances occurring above any baseline noise. (D) Percentage of fish with an abnormal electrical event during the ECG recording. Male n = 7 per genotype, ****p < 0.0001. Female n = 4-8 per genotype, ****p < 0.0001. Fisher’s exact test. (E) Categorization of ECG abnormalities observed throughout all wild type and irf8 mutant fish.

    Article Snippet: To record electrical impulses, we used the CardioPhys TM ECG system (World Precision Instruments), which included a low-noise gold ECG probe, micromanipulator, bio-amplifier and ground electrode, in combination with the PowerLab 2/26 data acquisition unit (ADInstruments, PL2602).

    Techniques: Mutagenesis

    (A) Cartoon depiction of an adult zebrafish undergoing an echocardiogram with the transducer in the long-axis (LAX) position. Echocardiograms were performed on unchallenged fish. (B) Cartoon of an adult zebrafish heart from the perspective of the echocardiography recording, denoting the atrium (A), atrioventricular (AV) valve, ventriculobulbar (VB) valve, and bulbus arteriosus (BA). The boxes around the AV valve and VB valve depict the gating strategies to determine inward flow and outward flow of blood from the ventricle. (C) Still image from an adult zebrafish echocardiography recording with the ventricle and bulbus arteriosus outlined in red. (D) Representative echocardiogram trace gating on the AV valve with the early filling (E) wave, late filling (A) wave, diastasis time, isovolumic contraction time (IVCT), aortic ejection time (AET), and isovolumic relaxation time (IVRT) labeled. (E-G) Quantifications of IVRT (E), AET (F), and pressure within the VB valve (G) in male and female wild type and irf8 mutant fish at 6 and 12 mpf. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Each point represents individual beats per fish. 8-10 beats were analyzed per fish. *p < 0.05; **p < 0.01; ***p < 0.001; ****p < 0.0001. (H) Quantification of heart in male and female wild type and irf8 mutants. (I) Representative echocardiogram traces from a wild type and irf8 mutant recording. (J-M) Quantification of diastasis time in wild type males (J) and females (K) at 6 mpf and 12 mpf, as well as diastasis time in irf8 mutant males (L) and females (M) at 6 mpf and 12 mpf. A Gaussian distribution was created by analyzing 8 beats per sample and grouping diastasis duration in defined increments. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Horizontal bars represent the range of diastasis duration. (N-O) 95% confidence interval of the average diastasis time durations in wild type (gray) and irf8 mutant (blue) males (N) and females (O).

    Journal: bioRxiv

    Article Title: Loss of developmentally derived Irf8+ macrophages promotes hyperinnervation and arrhythmia in the adult zebrafish heart

    doi: 10.1101/2024.04.17.589909

    Figure Lengend Snippet: (A) Cartoon depiction of an adult zebrafish undergoing an echocardiogram with the transducer in the long-axis (LAX) position. Echocardiograms were performed on unchallenged fish. (B) Cartoon of an adult zebrafish heart from the perspective of the echocardiography recording, denoting the atrium (A), atrioventricular (AV) valve, ventriculobulbar (VB) valve, and bulbus arteriosus (BA). The boxes around the AV valve and VB valve depict the gating strategies to determine inward flow and outward flow of blood from the ventricle. (C) Still image from an adult zebrafish echocardiography recording with the ventricle and bulbus arteriosus outlined in red. (D) Representative echocardiogram trace gating on the AV valve with the early filling (E) wave, late filling (A) wave, diastasis time, isovolumic contraction time (IVCT), aortic ejection time (AET), and isovolumic relaxation time (IVRT) labeled. (E-G) Quantifications of IVRT (E), AET (F), and pressure within the VB valve (G) in male and female wild type and irf8 mutant fish at 6 and 12 mpf. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Each point represents individual beats per fish. 8-10 beats were analyzed per fish. *p < 0.05; **p < 0.01; ***p < 0.001; ****p < 0.0001. (H) Quantification of heart in male and female wild type and irf8 mutants. (I) Representative echocardiogram traces from a wild type and irf8 mutant recording. (J-M) Quantification of diastasis time in wild type males (J) and females (K) at 6 mpf and 12 mpf, as well as diastasis time in irf8 mutant males (L) and females (M) at 6 mpf and 12 mpf. A Gaussian distribution was created by analyzing 8 beats per sample and grouping diastasis duration in defined increments. Male n = 10-21 per genotype and timepoint. Female n = 9-14 per genotype and timepoint. Horizontal bars represent the range of diastasis duration. (N-O) 95% confidence interval of the average diastasis time durations in wild type (gray) and irf8 mutant (blue) males (N) and females (O).

    Article Snippet: To record electrical impulses, we used the CardioPhys TM ECG system (World Precision Instruments), which included a low-noise gold ECG probe, micromanipulator, bio-amplifier and ground electrode, in combination with the PowerLab 2/26 data acquisition unit (ADInstruments, PL2602).

    Techniques: Labeling, Mutagenesis