dionex ultimate 3000 pump  (Thermo Fisher)


Bioz Verified Symbol Thermo Fisher is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99
    Name:
    Dionex UltiMate 3000 Series Pump Accessories
    Description:
    Choose Thermo Scientific Dionex UltiMate 3000 Series Pump Accessories that include maintenance kits manual injection valves mounting kits and syringe
    Catalog Number:
    6035.1950
    Price:
    None
    Applications:
    Industrial & Applied Science|Industrial Chromatography
    Category:
    Instruments and Equipment
    Buy from Supplier


    Structured Review

    Thermo Fisher dionex ultimate 3000 pump
    Choose Thermo Scientific Dionex UltiMate 3000 Series Pump Accessories that include maintenance kits manual injection valves mounting kits and syringe
    https://www.bioz.com/result/dionex ultimate 3000 pump/product/Thermo Fisher
    Average 99 stars, based on 6 article reviews
    Price from $9.99 to $1999.99
    dionex ultimate 3000 pump - by Bioz Stars, 2020-09
    99/100 stars

    Images

    Related Articles

    High Performance Liquid Chromatography:

    Article Title: Process relevant screening of cellulolytic organisms for consolidated bioprocessing
    Article Snippet: .. After centrifugation of the reaction mixture (16,900g ; 10 min.; 4 °C) and a second centrifugation step of the resulting supernatant (3000g ; 10 min.), glucose, cellobiose, and xylose concentration in the supernatant were analyzed by HPLC (Dionex HPLC UltiMate 3000, Thermo Scientific, Waltham, USA) at 65 °C using the following setup: Column: AMINEX Ion Exclusion HPX-87H, 300 × 7.8 mm (Bio-Rad Laboratories GmbH, Munich, Germany); detectors: Dionex™ Ultimate 3000 UV/VIS detector (Thermo Scientific, Waltham, USA) at 210 nm and RI-101 refractory index detector (Shodex, Munich, Germany); mobile phase: 5 mM sulfuric acid; flow rate: 0.7 mL min−1 . ..

    Centrifugation:

    Article Title: Process relevant screening of cellulolytic organisms for consolidated bioprocessing
    Article Snippet: .. After centrifugation of the reaction mixture (16,900g ; 10 min.; 4 °C) and a second centrifugation step of the resulting supernatant (3000g ; 10 min.), glucose, cellobiose, and xylose concentration in the supernatant were analyzed by HPLC (Dionex HPLC UltiMate 3000, Thermo Scientific, Waltham, USA) at 65 °C using the following setup: Column: AMINEX Ion Exclusion HPX-87H, 300 × 7.8 mm (Bio-Rad Laboratories GmbH, Munich, Germany); detectors: Dionex™ Ultimate 3000 UV/VIS detector (Thermo Scientific, Waltham, USA) at 210 nm and RI-101 refractory index detector (Shodex, Munich, Germany); mobile phase: 5 mM sulfuric acid; flow rate: 0.7 mL min−1 . ..

    Article Title: A Radical Clock Probe Uncouples H Atom Abstraction from Thioether Cross-Link Formation by the Radical S-Adenosyl-l-methionine Enzyme SkfB
    Article Snippet: .. Insoluble material was removed by centrifugation, and an aliquot (25 μL) was analyzed using a Hypersil GOLD C18 column (2.1 mm × 150 mm, 1.9 μm particle size; Thermo Fisher) attached to a Thermo Scientific Dionex UltiMate 3000 UHPLC instrument. ..

    Mass Spectrometry:

    Article Title: Restricted Proteolysis and LC-MS/MS To Evaluate the Orientation of Surface-Immobilized Antibodies
    Article Snippet: .. For the analysis of digest samples, a Thermo Scientific Dionex Ultimate 3000 UHPLC system was interfaced to either a SCIEX QSTAR Elite quadrupole time-of-flight mass spectrometer (Q-TOF, for peptide identification) or a Thermo Scientific TSQ Quantiva triple quadruple mass spectrometer (QqQ, for peptide quantitation). .. Peptide separation was done on a Jupiter C18 column (150 × 0.50 mm, 5 μ m, Phenomenex) with gradient elution ( ).

    Article Title: Identification and distribution of gene clusters required for synthesis of sphingolipid metabolism inhibitors in diverse species of the filamentous fungus Fusarium
    Article Snippet: .. Detection and quantification of AOD was done with a liquid chromatography-mass spectrometry (LC-MS) system, consisting of a Thermo Dionex Ultimate 3000 chromatography system coupled to a Thermo QExactive high resolution tandem mass spectrometer (ThermoScientific). .. The LC system employed a 50 mm × 2 mm Luna C18 column (Phenomenex) and a solvent system consisting of 40 to 95% aqueous methanol gradient over 5 min with a flow rate of 0.6 mL/min.

    Chromatography:

    Article Title: Identification and distribution of gene clusters required for synthesis of sphingolipid metabolism inhibitors in diverse species of the filamentous fungus Fusarium
    Article Snippet: .. Detection and quantification of AOD was done with a liquid chromatography-mass spectrometry (LC-MS) system, consisting of a Thermo Dionex Ultimate 3000 chromatography system coupled to a Thermo QExactive high resolution tandem mass spectrometer (ThermoScientific). .. The LC system employed a 50 mm × 2 mm Luna C18 column (Phenomenex) and a solvent system consisting of 40 to 95% aqueous methanol gradient over 5 min with a flow rate of 0.6 mL/min.

    Flow Cytometry:

    Article Title: Process relevant screening of cellulolytic organisms for consolidated bioprocessing
    Article Snippet: .. After centrifugation of the reaction mixture (16,900g ; 10 min.; 4 °C) and a second centrifugation step of the resulting supernatant (3000g ; 10 min.), glucose, cellobiose, and xylose concentration in the supernatant were analyzed by HPLC (Dionex HPLC UltiMate 3000, Thermo Scientific, Waltham, USA) at 65 °C using the following setup: Column: AMINEX Ion Exclusion HPX-87H, 300 × 7.8 mm (Bio-Rad Laboratories GmbH, Munich, Germany); detectors: Dionex™ Ultimate 3000 UV/VIS detector (Thermo Scientific, Waltham, USA) at 210 nm and RI-101 refractory index detector (Shodex, Munich, Germany); mobile phase: 5 mM sulfuric acid; flow rate: 0.7 mL min−1 . ..

    Concentration Assay:

    Article Title: Process relevant screening of cellulolytic organisms for consolidated bioprocessing
    Article Snippet: .. After centrifugation of the reaction mixture (16,900g ; 10 min.; 4 °C) and a second centrifugation step of the resulting supernatant (3000g ; 10 min.), glucose, cellobiose, and xylose concentration in the supernatant were analyzed by HPLC (Dionex HPLC UltiMate 3000, Thermo Scientific, Waltham, USA) at 65 °C using the following setup: Column: AMINEX Ion Exclusion HPX-87H, 300 × 7.8 mm (Bio-Rad Laboratories GmbH, Munich, Germany); detectors: Dionex™ Ultimate 3000 UV/VIS detector (Thermo Scientific, Waltham, USA) at 210 nm and RI-101 refractory index detector (Shodex, Munich, Germany); mobile phase: 5 mM sulfuric acid; flow rate: 0.7 mL min−1 . ..

    Quantitation Assay:

    Article Title: Restricted Proteolysis and LC-MS/MS To Evaluate the Orientation of Surface-Immobilized Antibodies
    Article Snippet: .. For the analysis of digest samples, a Thermo Scientific Dionex Ultimate 3000 UHPLC system was interfaced to either a SCIEX QSTAR Elite quadrupole time-of-flight mass spectrometer (Q-TOF, for peptide identification) or a Thermo Scientific TSQ Quantiva triple quadruple mass spectrometer (QqQ, for peptide quantitation). .. Peptide separation was done on a Jupiter C18 column (150 × 0.50 mm, 5 μ m, Phenomenex) with gradient elution ( ).

    Liquid Chromatography with Mass Spectroscopy:

    Article Title: Identification and distribution of gene clusters required for synthesis of sphingolipid metabolism inhibitors in diverse species of the filamentous fungus Fusarium
    Article Snippet: .. Detection and quantification of AOD was done with a liquid chromatography-mass spectrometry (LC-MS) system, consisting of a Thermo Dionex Ultimate 3000 chromatography system coupled to a Thermo QExactive high resolution tandem mass spectrometer (ThermoScientific). .. The LC system employed a 50 mm × 2 mm Luna C18 column (Phenomenex) and a solvent system consisting of 40 to 95% aqueous methanol gradient over 5 min with a flow rate of 0.6 mL/min.

    Liquid Chromatography:

    Article Title: Opportunities for Successful Stabilization of Poor Glass-Forming Drugs: A Stability-Based Comparison of Mesoporous Silica Versus Hot Melt Extrusion Technologies
    Article Snippet: .. Ultra-High Performance Liquid Chromatography (UHPLC) UHPLC analysis was performed using a Thermo Dionex Ultimate 3000 (Thermo Fisher, Waltham, MA, USA) equipped with a diode array detector at 282 nm for carbamazepine and 247 nm for haloperidol (Thermo Fisher, Waltham, MA, USA). .. The separation was achieved on an Acquity UPLC BEH column C8 (2.1 × 50 mm, 1.7 µm, Waters, Milford, MA, USA).

    Article Title: Transcriptomic and proteomic regulation through abundant, dynamic, and independent arginine methylation by Type I and Type II PRMTs
    Article Snippet: .. Input samples were loaded into a Dionex UltiMate 3000 (Thermo Fisher Scientific) liquid chromatography system, coupled with an Q-Exactive HF instrument (Thermo Fisher Scientific). ..

    Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99
    Thermo Fisher ultimate 3000 rs pump
    Ultimate 3000 Rs Pump, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 35 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/ultimate 3000 rs pump/product/Thermo Fisher
    Average 99 stars, based on 35 article reviews
    Price from $9.99 to $1999.99
    ultimate 3000 rs pump - by Bioz Stars, 2020-09
    99/100 stars
      Buy from Supplier

    Image Search Results