continuous flow isotope ratio mass spectrometer  (Thermo Fisher)


Bioz Verified Symbol Thermo Fisher is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Thermo Fisher continuous flow isotope ratio mass spectrometer
    Continuous Flow Isotope Ratio Mass Spectrometer, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 47 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/continuous flow isotope ratio mass spectrometer/product/Thermo Fisher
    Average 99 stars, based on 47 article reviews
    Price from $9.99 to $1999.99
    continuous flow isotope ratio mass spectrometer - by Bioz Stars, 2020-03
    99/100 stars

    Images

    Related Articles

    Flow Cytometry:

    Article Title: Dietary Plasticity of Generalist and Specialist Ungulates in the Namibian Desert: A Stable Isotopes Approach
    Article Snippet: .. Samples were combusted and the resultant gases (N2 and CO2 ) were sequentially measured in a CE 1110 elemental analyzer connected via a continuous flow system to a Thermo Finnigan Delta Plus isotope ratio mass spectrometer (Thermo Finnigan, Bremen, Germany). ..

    Gas Chromatography:

    Article Title: Biochar Addition Increases the Rates of Dissimilatory Iron Reduction and Methanogenesis in Ferrihydrite Enrichments
    Article Snippet: Headspace CO2 and CH4 concentrations were measured by using a robotized incubation system with an Agilent 7890 gas chromatography (Santa Clara, CA, US) as previously described ( ). .. For analysis of 13 CO2 and 13 CH4 , 2 mL gas samples were collected by gastight syringes, and then the ratios of 13 C in total CH4 and CO2 were measured by GC-isotope ratio mass spectrometry (Thermo Finnigan Delta V Advantage, Bremen, Germany) ( ).

    Ion Chromatography:

    Article Title: Biochar Addition Increases the Rates of Dissimilatory Iron Reduction and Methanogenesis in Ferrihydrite Enrichments
    Article Snippet: The concentrations of acetate in medium were analyzed by ion chromatography (Dionex ICS-3000 system, Diones, Sunnyvales, CA, USA) with a detection limit of approximately 3.4 nmol L-1 . .. For analysis of 13 CO2 and 13 CH4 , 2 mL gas samples were collected by gastight syringes, and then the ratios of 13 C in total CH4 and CO2 were measured by GC-isotope ratio mass spectrometry (Thermo Finnigan Delta V Advantage, Bremen, Germany) ( ).

    In Vitro:

    Article Title: Overexpression of a pine Dof transcription factor in hybrid poplars: A comparative study in trees growing under controlled and natural conditions
    Article Snippet: 15 N uptake in hydroponic culture In vitro rooted transgenic and control plantlets were acclimatized in transparent plastic pots (500mL volume) containing Hoagland solution [ ] for 2 weeks. .. Later, roots were washed with 0.5 mM CaCl2 to remove any adsorbed 15 N. Roots were oven-dried at 70°C for 2 days and ground into powder for the analysis of 15 N content. δ15 N (‰) values were determined using a Flash EA 1112 elemental analyzer coupled to a Delta V Advantage isotope ratio mass spectrometer (Thermo Scientific, USA).

    Chromatography:

    Article Title: Microbial community composition and carbon cycling within soil microenvironments of conventional, low-input, and organic cropping systems
    Article Snippet: .. After mild alkaline methanolysis to form fatty acid methyl esters (FAMEs), FAMEs were analyzed using a Thermo gas chromatography-combustion-isotope ratio mass spectroscopy (GC-c-IRMS) system, which consisted of a Trace GC Ultra gas chromatograph (Thermo Electron Corp., Milan, Italy) coupled to a Delta Plus Advantage isotope ratio mass spectrometer through a GC/C-III interface (Thermo Electron Corp., Bremen, Germany). .. With He as the carrier gas, FAMEs were injected in splitless mode and resolved in a J & W DB-5 column (30 m × 0.25 μm ID, 0.25 μm film thickness) with an initial temperature of 60 °C for 0.1 min, ramped to 150 °C at 10 °C min-1 and held for 2 min, ramped to 220 °C at 3 °C min-1 , ramped to 280 °C at 2 °C min-1 and held for 5 min, and quantitatively converted to CO2 in an oxidation reactor at 950 °C.

    Article Title: Macroscopic Biofilms in Fracture-Dominated Sediment That Anaerobically Oxidize Methane ▿Macroscopic Biofilms in Fracture-Dominated Sediment That Anaerobically Oxidize Methane ▿ †
    Article Snippet: Methane concentrations were determined by the headspace equilibration technique and gas chromatography-flame ionization detection using a Hewlett-Packard 6890 Plus (GC3) apparatus during EXP 311 and NGHP01 and a Shimadzu GC-14A apparatus during PGC0807. .. Samples for stable carbon isotope analysis of the biofilm were placed in silver cups, acidified with 10% HCl to dissolve all carbonaceous material, dried at 50°C for 24 h, and then combusted with a Fisons EA-1100 elemental analyzer (EA) interfaced to a Thermo Finnigan Delta Plus isotope ratio mass spectrometer.

    Article Title: Isoprenoid Quinones Resolve the Stratification of Redox Processes in a Biogeochemical Continuum from the Photic Zone to Deep Anoxic Sediments of the Black Sea
    Article Snippet: After heating, 100- to 500-μl subsamples were taken from the headspace gas with a gas-tight syringe and analyzed by gas chromatography-flame ionization detection using a Carboxen-1006 PLOT fused-silica capillary column (0.32 mm by 30 m; Supelco, Inc., USA) on a ThermoFinnigan Trace GC. .. The stable carbon isotopic composition of methane was determined from duplicate analyses of the same samples using a Trace GC Ultra coupled to a Delta Plus XP isotope ratio mass spectrometer via a GC Combustion III interface (all ThermoFinnigan), as described previously ( ).

    Transgenic Assay:

    Article Title: Overexpression of a pine Dof transcription factor in hybrid poplars: A comparative study in trees growing under controlled and natural conditions
    Article Snippet: 15 N uptake in hydroponic culture In vitro rooted transgenic and control plantlets were acclimatized in transparent plastic pots (500mL volume) containing Hoagland solution [ ] for 2 weeks. .. Later, roots were washed with 0.5 mM CaCl2 to remove any adsorbed 15 N. Roots were oven-dried at 70°C for 2 days and ground into powder for the analysis of 15 N content. δ15 N (‰) values were determined using a Flash EA 1112 elemental analyzer coupled to a Delta V Advantage isotope ratio mass spectrometer (Thermo Scientific, USA).

    Labeling:

    Article Title: Soil microorganisms can overcome respiration inhibition by coupling intra- and extracellular metabolism: 13C metabolic tracing reveals the mechanisms
    Article Snippet: Dried SrCO3 samples (1–2 mg) were loaded into tin capsules and δ13 C value was measured with a Flash 2000 Elemental analyzer coupled by a ConFlo III interface to a Delta V advantage Isotope Ratio Mass Spectrometer IRMS (all units from Thermo Fisher Scientific, Bremen, Germany). .. 13 C respired from the applied glucose was calculated according to a mixing model (Equations (1) and ( )), where the C content of the background ([C]BG ) in Equation (1) was determined by Equation (2) ( ) where [C]CO2 /BG/appG C content of the sample/background/applied glucose (mg C g−1 soil); r CO2 /BG/appG 13 C atom %-excess of labeled sample/background/applied glucose (at%).

    Sampling:

    Article Title: Organic vs. Conventional Grassland Management: Do 15N and 13C Isotopic Signatures of Hay and Soil Samples Differ?
    Article Snippet: Field work and chemical analyses Soil sampling was conducted in early May 2011. .. Evolved CO2 was analysed using an isotope ratio mass spectrometer (IRMS; Delta C or DELTA+XL, Thermo Finnigan MAT, Bremen, Germany).

    Sedimentation:

    Article Title: Year-Long Monitoring of Physico-Chemical and Biological Variables Provide a Comparative Baseline of Coral Reef Functioning in the Central Red Sea
    Article Snippet: Paragraph title: Sedimentation ... Isotopic ratios (δ13 C and δ15 N) were analyzed relative to Pee Dee Belemnite standard and atmospheric nitrogen using an isotope ratio mass spectrometer (Delta plus XP, Thermo Finnigan, USA).

    Incubation:

    Article Title: Isoprenoid Quinones Resolve the Stratification of Redox Processes in a Biogeochemical Continuum from the Photic Zone to Deep Anoxic Sediments of the Black Sea
    Article Snippet: In brief, 2 to 3 ml of wet sediment was incubated in a gas-tight 22-ml glass vial with a Teflon septum for 20 min at 60°C. .. The stable carbon isotopic composition of methane was determined from duplicate analyses of the same samples using a Trace GC Ultra coupled to a Delta Plus XP isotope ratio mass spectrometer via a GC Combustion III interface (all ThermoFinnigan), as described previously ( ).

    Article Title: Biochar Addition Increases the Rates of Dissimilatory Iron Reduction and Methanogenesis in Ferrihydrite Enrichments
    Article Snippet: Headspace CO2 and CH4 concentrations were measured by using a robotized incubation system with an Agilent 7890 gas chromatography (Santa Clara, CA, US) as previously described ( ). .. For analysis of 13 CO2 and 13 CH4 , 2 mL gas samples were collected by gastight syringes, and then the ratios of 13 C in total CH4 and CO2 were measured by GC-isotope ratio mass spectrometry (Thermo Finnigan Delta V Advantage, Bremen, Germany) ( ).

    Article Title: Diversity and Activity of Diazotrophs in Great Barrier Reef Surface Waters
    Article Snippet: Paragraph title: Dinitrogen Fixation Incubation ... Post-voyage, enriched filters were dried separately from the natural abundance filters at 60°C for 48 h, and isotopic composition along with total particulate N and carbon were determined using an elemental analyzer (Thermo Finnigan MAT Conflo IV) coupled to an isotope ratio mass spectrometer (Thermo Finnigan Delta XP; limit of detection = 15 μg N per filter) (Research Corporation of the University of Hawaii).

    Article Title: Overexpression of a pine Dof transcription factor in hybrid poplars: A comparative study in trees growing under controlled and natural conditions
    Article Snippet: To determine the uptake of nitrogen, plants were incubated for 2 h in the same solution but containing 15 N-label (either as 1 mM K15 NO3 or 1 mM 15 NH4 Cl). .. Later, roots were washed with 0.5 mM CaCl2 to remove any adsorbed 15 N. Roots were oven-dried at 70°C for 2 days and ground into powder for the analysis of 15 N content. δ15 N (‰) values were determined using a Flash EA 1112 elemental analyzer coupled to a Delta V Advantage isotope ratio mass spectrometer (Thermo Scientific, USA).

    Standard Deviation:

    Article Title: Increasing sika deer population density may change resource use by larval dung beetles
    Article Snippet: Each sample was enclosed in a tin cup and combusted in a FlashEA1112 elemental analyzer (Thermo Fisher Scientific, Bremen, Germany) interfaced with a Delta V isotope-ratio mass spectrometer (Thermo Fisher Scientific) to determine the nitrogen isotope ratio. .. The analytical standard deviation (SD) of the stable isotope analysis was ± 0.15‰ for δ 15 N.

    Mass Spectrometry:

    Article Title: Microbial community composition and carbon cycling within soil microenvironments of conventional, low-input, and organic cropping systems
    Article Snippet: .. After mild alkaline methanolysis to form fatty acid methyl esters (FAMEs), FAMEs were analyzed using a Thermo gas chromatography-combustion-isotope ratio mass spectroscopy (GC-c-IRMS) system, which consisted of a Trace GC Ultra gas chromatograph (Thermo Electron Corp., Milan, Italy) coupled to a Delta Plus Advantage isotope ratio mass spectrometer through a GC/C-III interface (Thermo Electron Corp., Bremen, Germany). .. With He as the carrier gas, FAMEs were injected in splitless mode and resolved in a J & W DB-5 column (30 m × 0.25 μm ID, 0.25 μm film thickness) with an initial temperature of 60 °C for 0.1 min, ramped to 150 °C at 10 °C min-1 and held for 2 min, ramped to 220 °C at 3 °C min-1 , ramped to 280 °C at 2 °C min-1 and held for 5 min, and quantitatively converted to CO2 in an oxidation reactor at 950 °C.

    Article Title: Organic vs. Conventional Grassland Management: Do 15N and 13C Isotopic Signatures of Hay and Soil Samples Differ?
    Article Snippet: .. Evolved CO2 was analysed using an isotope ratio mass spectrometer (IRMS; Delta C or DELTA+XL, Thermo Finnigan MAT, Bremen, Germany). .. For biomass sampling, we harvested aboveground community biomass in four quadrates of 0.25 m2 from mid-May to mid-June 2011 in both regions simultaneously.

    Article Title: Macroscopic Biofilms in Fracture-Dominated Sediment That Anaerobically Oxidize Methane ▿Macroscopic Biofilms in Fracture-Dominated Sediment That Anaerobically Oxidize Methane ▿ †
    Article Snippet: .. Samples for stable carbon isotope analysis of the biofilm were placed in silver cups, acidified with 10% HCl to dissolve all carbonaceous material, dried at 50°C for 24 h, and then combusted with a Fisons EA-1100 elemental analyzer (EA) interfaced to a Thermo Finnigan Delta Plus isotope ratio mass spectrometer. ..

    Article Title: Isoprenoid Quinones Resolve the Stratification of Redox Processes in a Biogeochemical Continuum from the Photic Zone to Deep Anoxic Sediments of the Black Sea
    Article Snippet: .. The stable carbon isotopic composition of methane was determined from duplicate analyses of the same samples using a Trace GC Ultra coupled to a Delta Plus XP isotope ratio mass spectrometer via a GC Combustion III interface (all ThermoFinnigan), as described previously ( ). ..

    Article Title: Dietary Plasticity of Generalist and Specialist Ungulates in the Namibian Desert: A Stable Isotopes Approach
    Article Snippet: .. Samples were combusted and the resultant gases (N2 and CO2 ) were sequentially measured in a CE 1110 elemental analyzer connected via a continuous flow system to a Thermo Finnigan Delta Plus isotope ratio mass spectrometer (Thermo Finnigan, Bremen, Germany). ..

    Article Title: Biochar Addition Increases the Rates of Dissimilatory Iron Reduction and Methanogenesis in Ferrihydrite Enrichments
    Article Snippet: .. For analysis of 13 CO2 and 13 CH4 , 2 mL gas samples were collected by gastight syringes, and then the ratios of 13 C in total CH4 and CO2 were measured by GC-isotope ratio mass spectrometry (Thermo Finnigan Delta V Advantage, Bremen, Germany) ( ). ..

    Article Title: Soil microorganisms can overcome respiration inhibition by coupling intra- and extracellular metabolism: 13C metabolic tracing reveals the mechanisms
    Article Snippet: .. Dried SrCO3 samples (1–2 mg) were loaded into tin capsules and δ13 C value was measured with a Flash 2000 Elemental analyzer coupled by a ConFlo III interface to a Delta V advantage Isotope Ratio Mass Spectrometer IRMS (all units from Thermo Fisher Scientific, Bremen, Germany). .. 13 C respired from the applied glucose was calculated according to a mixing model (Equations (1) and ( )), where the C content of the background ([C]BG ) in Equation (1) was determined by Equation (2) ( ) where [C]CO2 /BG/appG C content of the sample/background/applied glucose (mg C g−1 soil); r CO2 /BG/appG 13 C atom %-excess of labeled sample/background/applied glucose (at%).

    Article Title: Year-Long Monitoring of Physico-Chemical and Biological Variables Provide a Comparative Baseline of Coral Reef Functioning in the Central Red Sea
    Article Snippet: .. Isotopic ratios (δ13 C and δ15 N) were analyzed relative to Pee Dee Belemnite standard and atmospheric nitrogen using an isotope ratio mass spectrometer (Delta plus XP, Thermo Finnigan, USA). .. Univariate analyses of physico-chemical variables Univariate 2-factorial permutational MANOVAs (PERMANOVAs, Primer-E V6 [ ]) were used to characterize the differences between the factors “reef” (3 levels: nearshore, midshore, and offshore) and “season” (4 levels: spring, summer, fall, and winter) for each of the 10 physico-chemical variables (current direction, current speed, temperature, salinity, DO, chlorophyll-a, turbidity, sedimentation rate, and OC and C:N ratios of sediments).

    Article Title: Metabolism and foraging strategies of mid‐latitude mesozooplankton during cyanobacterial blooms as revealed by fatty acids, amino acids, and their stable carbon isotopes, et al. Metabolism and foraging strategies of mid‐latitude mesozooplankton during cyanobacterial blooms as revealed by fatty acids, amino acids, and their stable carbon isotopes
    Article Snippet: .. The δ13 C composition in FAMEs was measured for the most abundant FAs in mesozooplankton samples using a Thermo GC‐C‐IRMS system, equipped with a Trace GC Ultra gas chromatograph, a GC IsoLink, and a Delta V Plus isotope ratio mass spectrometer, connected via a Conflo IV interface (Thermo Scientific Corporation). .. The FAMEs, dissolved in hexane, were injected in splitless mode and separated on a 60 m long DB‐FFAP column (0.25 mm I.D., film thickness: 0.25 μm; liquid phase).

    Article Title: Increasing sika deer population density may change resource use by larval dung beetles
    Article Snippet: .. Each sample was enclosed in a tin cup and combusted in a FlashEA1112 elemental analyzer (Thermo Fisher Scientific, Bremen, Germany) interfaced with a Delta V isotope-ratio mass spectrometer (Thermo Fisher Scientific) to determine the nitrogen isotope ratio. ..

    Article Title: Regional patterns of 15N natural abundance in forest ecosystems along a large transect in eastern China
    Article Snippet: .. N concentrations and δ 15 N analysis Nitrogen concentrations and δ 15 N values were determined simultaneously with an automatic, online elemental analyser (Flash EA1112, ThermoFinnigan, Milan, Italy) coupled to an isotope ratio mass spectrometer (IRMS) (Finnigan MAT 253, Thermo Electron, Bremen, Germany). ..

    Article Title: Overexpression of a pine Dof transcription factor in hybrid poplars: A comparative study in trees growing under controlled and natural conditions
    Article Snippet: .. Later, roots were washed with 0.5 mM CaCl2 to remove any adsorbed 15 N. Roots were oven-dried at 70°C for 2 days and ground into powder for the analysis of 15 N content. δ15 N (‰) values were determined using a Flash EA 1112 elemental analyzer coupled to a Delta V Advantage isotope ratio mass spectrometer (Thermo Scientific, USA). ..

    Article Title: Discovery and biogeochemistry of asphalt seeps in the North São Paulo Plateau, Brazilian Margin
    Article Snippet: .. Stable isotopes (δ13 C and δ15 N) were determined by an automatic elemental analyzer (EuroVector EA3000) coupled with an isotope ratio mass spectrometer (IsoPrime, GV Instruments, Manchester, UK) (sediment and asphalt samples taken from dives #1345 and #1346) and an automatic elemental analyzer (Flash EA 1112, Thermo Fisher Scientific, UK) coupled with an isotope ratio mass spectrometer (Delta V Advantage, Thermo Fisher Scientific, UK) (sediment samples taken from dive #1343), respectively. ..

    Article Title: Responses of zooplankton body size and community trophic structure to temperature change in a subtropical reservoir. Responses of zooplankton body size and community trophic structure to temperature change in a subtropical reservoir
    Article Snippet: .. Percentage carbon, percentage nitrogen, and stable isotopic ratios were measured using the Thermo Electron Flash EA 2000 Elemental Analyzer (EA) coupled to a Delta V isotope ratio mass spectrometer (IRMS) (Thermo Fisher Scientific Inc.). ..

    Concentration Assay:

    Article Title: Macroscopic Biofilms in Fracture-Dominated Sediment That Anaerobically Oxidize Methane ▿Macroscopic Biofilms in Fracture-Dominated Sediment That Anaerobically Oxidize Methane ▿ †
    Article Snippet: Samples tested for pore water methane concentration were collected as 3-cm3 sediment plugs from split cores and stored at −20°C in 20-ml serum vials sealed with 1-cm-thick butyl rubber septa. .. Samples for stable carbon isotope analysis of the biofilm were placed in silver cups, acidified with 10% HCl to dissolve all carbonaceous material, dried at 50°C for 24 h, and then combusted with a Fisons EA-1100 elemental analyzer (EA) interfaced to a Thermo Finnigan Delta Plus isotope ratio mass spectrometer.

    Filtration:

    Article Title: Diversity and Activity of Diazotrophs in Great Barrier Reef Surface Waters
    Article Snippet: After ∼24 h, incubations were terminated by filtration onto pre-combusted GF/F (0.7 μm pore size, Whatman) and frozen at -20°C. .. Post-voyage, enriched filters were dried separately from the natural abundance filters at 60°C for 48 h, and isotopic composition along with total particulate N and carbon were determined using an elemental analyzer (Thermo Finnigan MAT Conflo IV) coupled to an isotope ratio mass spectrometer (Thermo Finnigan Delta XP; limit of detection = 15 μg N per filter) (Research Corporation of the University of Hawaii).

    Injection:

    Article Title: Microbial community composition and carbon cycling within soil microenvironments of conventional, low-input, and organic cropping systems
    Article Snippet: After mild alkaline methanolysis to form fatty acid methyl esters (FAMEs), FAMEs were analyzed using a Thermo gas chromatography-combustion-isotope ratio mass spectroscopy (GC-c-IRMS) system, which consisted of a Trace GC Ultra gas chromatograph (Thermo Electron Corp., Milan, Italy) coupled to a Delta Plus Advantage isotope ratio mass spectrometer through a GC/C-III interface (Thermo Electron Corp., Bremen, Germany). .. With He as the carrier gas, FAMEs were injected in splitless mode and resolved in a J & W DB-5 column (30 m × 0.25 μm ID, 0.25 μm film thickness) with an initial temperature of 60 °C for 0.1 min, ramped to 150 °C at 10 °C min-1 and held for 2 min, ramped to 220 °C at 3 °C min-1 , ramped to 280 °C at 2 °C min-1 and held for 5 min, and quantitatively converted to CO2 in an oxidation reactor at 950 °C.

    Article Title: Diversity and Activity of Diazotrophs in Great Barrier Reef Surface Waters
    Article Snippet: Bottles were capped with septa without introducing headspace, then injected with 3 ml 15 N2 gas (98 atom%, Sigma–Aldrich, Australia) and inverted 100 times, leading to a theoretical enrichment of 7–8 atom%, assuming complete dissolution of the 15 N2 gas bubble ( ). .. Post-voyage, enriched filters were dried separately from the natural abundance filters at 60°C for 48 h, and isotopic composition along with total particulate N and carbon were determined using an elemental analyzer (Thermo Finnigan MAT Conflo IV) coupled to an isotope ratio mass spectrometer (Thermo Finnigan Delta XP; limit of detection = 15 μg N per filter) (Research Corporation of the University of Hawaii).

    Article Title: Metabolism and foraging strategies of mid‐latitude mesozooplankton during cyanobacterial blooms as revealed by fatty acids, amino acids, and their stable carbon isotopes, et al. Metabolism and foraging strategies of mid‐latitude mesozooplankton during cyanobacterial blooms as revealed by fatty acids, amino acids, and their stable carbon isotopes
    Article Snippet: The δ13 C composition in FAMEs was measured for the most abundant FAs in mesozooplankton samples using a Thermo GC‐C‐IRMS system, equipped with a Trace GC Ultra gas chromatograph, a GC IsoLink, and a Delta V Plus isotope ratio mass spectrometer, connected via a Conflo IV interface (Thermo Scientific Corporation). .. The FAMEs, dissolved in hexane, were injected in splitless mode and separated on a 60 m long DB‐FFAP column (0.25 mm I.D., film thickness: 0.25 μm; liquid phase).

    Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99
    Thermo Fisher continuous flow isotope ratio mass spectrometry
    Continuous Flow Isotope Ratio Mass Spectrometry, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 35 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/continuous flow isotope ratio mass spectrometry/product/Thermo Fisher
    Average 99 stars, based on 35 article reviews
    Price from $9.99 to $1999.99
    continuous flow isotope ratio mass spectrometry - by Bioz Stars, 2020-03
    99/100 stars
      Buy from Supplier

    Image Search Results