Structured Review

Roche cobas integra 800 analyzer
Cobas Integra 800 Analyzer, supplied by Roche, used in various techniques. Bioz Stars score: 91/100, based on 43 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cobas integra 800 analyzer/product/Roche
Average 91 stars, based on 43 article reviews
Price from $9.99 to $1999.99
cobas integra 800 analyzer - by Bioz Stars, 2020-08
91/100 stars

Images

Related Articles

Inter Assay:

Article Title: Estimated GFR and Risk of Hip Fracture in Older Men: Comparison of Associations Using Cystatin C and Creatinine
Article Snippet: .. Serum cystatin C concentrations were determined using a BN100 nephelometer (Dade Behring Inc., Deerfield, IL) using a particle-enhanced immunonephelometric assay (assay range, 0.23–8.00 mg/L; inter-assay coefficients of variation [CV] of 4.0% and 3.1% at levels of 0.71 mg/L and 1.75 mg/L, respectively [mean, 3.7%]) and then converted to standardized values traceable to a certified reference material. eGFRcys was computed using the CKD Epidemiology Collaboration (CKD-EPI) 2012 equation expressed for standardized cystatin C. Serum creatinine concentrations were measured using a Roche COBAS Integra 800 analyzer (Roche Diagnostic Corporation, Indianapolis, IN) at the Portland VA (Veterans Affairs) Medical Center using an enzymatic method calibrated with materials assayed by isotope-dilution mass spectrometry (IDMS). .. Inter-assay CV is 5.3%. eGFRcr was calculated using the CKD-EPI 2009 equation which includes variables for standardized creatinine, age, gender and race. eGFRcr-cys was calculated using the CKD-EPI 2012 creatinine-cystatin C equation.

Inhibition:

Article Title: Influence of HbA1c and BMI on Lipid Trajectories in Youths and Young Adults With Type 1 Diabetes
Article Snippet: .. Beginning in November 2010, a turbidimetric inhibition immunoassay using the Roche Cobas Integra 800 Analyzer was used. ..

AST Assay:

Article Title: A cross-sectional study of hepatitis C among people living with HIV in Cambodia: Prevalence, risk factors, and potential for targeted screening
Article Snippet: .. ALT and AST were determined on the Cobas Integra 800 analyzer (Roche Diagnostics Ltd., Mannheim, Germany). .. Normal values were ALT < 41 IU/L and AST < 40 IU/L for males, and ALT < 33 IU/L and AST < 32 IU/L for females.

Isotope Dilution:

Article Title: Estimated GFR and Risk of Hip Fracture in Older Men: Comparison of Associations Using Cystatin C and Creatinine
Article Snippet: .. Serum cystatin C concentrations were determined using a BN100 nephelometer (Dade Behring Inc., Deerfield, IL) using a particle-enhanced immunonephelometric assay (assay range, 0.23–8.00 mg/L; inter-assay coefficients of variation [CV] of 4.0% and 3.1% at levels of 0.71 mg/L and 1.75 mg/L, respectively [mean, 3.7%]) and then converted to standardized values traceable to a certified reference material. eGFRcys was computed using the CKD Epidemiology Collaboration (CKD-EPI) 2012 equation expressed for standardized cystatin C. Serum creatinine concentrations were measured using a Roche COBAS Integra 800 analyzer (Roche Diagnostic Corporation, Indianapolis, IN) at the Portland VA (Veterans Affairs) Medical Center using an enzymatic method calibrated with materials assayed by isotope-dilution mass spectrometry (IDMS). .. Inter-assay CV is 5.3%. eGFRcr was calculated using the CKD-EPI 2009 equation which includes variables for standardized creatinine, age, gender and race. eGFRcr-cys was calculated using the CKD-EPI 2012 creatinine-cystatin C equation.

Article Title: Association of Serum Uric Acid and Incident Nonspine Fractures in Elderly Men: The Osteoporotic Fractures in Men (MrOS) Study
Article Snippet: .. Serum cystatin C levels were determined using a BN100 nephelometer (Dade Behring Inc., Deerfield, IL, USA) using a particle-enhanced immunonepholometric assay. Serum creatinine, calcium, and phosphate concentrations were measured using a Roche COBAS Integra 800 analyzer (Roche Diagnostic Corporation, Indianapolis, IN, USA) at the Portland VA Medical Center using an enzymatic method calibrated with materials assayed by isotope-dilution mass spectrometry (IDMS). .. A combined formula using standardized cystatin C and creatinine-based estimated glomerular filtration rate (eGFRcysC ) was computed using a CKD-EPI creatinine-cystatin C equation given that this was shown to be the most accurate estimate of renal function in a recent publication. ( - )

Mass Spectrometry:

Article Title: Estimated GFR and Risk of Hip Fracture in Older Men: Comparison of Associations Using Cystatin C and Creatinine
Article Snippet: .. Serum cystatin C concentrations were determined using a BN100 nephelometer (Dade Behring Inc., Deerfield, IL) using a particle-enhanced immunonephelometric assay (assay range, 0.23–8.00 mg/L; inter-assay coefficients of variation [CV] of 4.0% and 3.1% at levels of 0.71 mg/L and 1.75 mg/L, respectively [mean, 3.7%]) and then converted to standardized values traceable to a certified reference material. eGFRcys was computed using the CKD Epidemiology Collaboration (CKD-EPI) 2012 equation expressed for standardized cystatin C. Serum creatinine concentrations were measured using a Roche COBAS Integra 800 analyzer (Roche Diagnostic Corporation, Indianapolis, IN) at the Portland VA (Veterans Affairs) Medical Center using an enzymatic method calibrated with materials assayed by isotope-dilution mass spectrometry (IDMS). .. Inter-assay CV is 5.3%. eGFRcr was calculated using the CKD-EPI 2009 equation which includes variables for standardized creatinine, age, gender and race. eGFRcr-cys was calculated using the CKD-EPI 2012 creatinine-cystatin C equation.

Article Title: Association of Serum Uric Acid and Incident Nonspine Fractures in Elderly Men: The Osteoporotic Fractures in Men (MrOS) Study
Article Snippet: .. Serum cystatin C levels were determined using a BN100 nephelometer (Dade Behring Inc., Deerfield, IL, USA) using a particle-enhanced immunonepholometric assay. Serum creatinine, calcium, and phosphate concentrations were measured using a Roche COBAS Integra 800 analyzer (Roche Diagnostic Corporation, Indianapolis, IN, USA) at the Portland VA Medical Center using an enzymatic method calibrated with materials assayed by isotope-dilution mass spectrometry (IDMS). .. A combined formula using standardized cystatin C and creatinine-based estimated glomerular filtration rate (eGFRcysC ) was computed using a CKD-EPI creatinine-cystatin C equation given that this was shown to be the most accurate estimate of renal function in a recent publication. ( - )

Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 91
    Roche cobas integra 800 analyzer
    Cobas Integra 800 Analyzer, supplied by Roche, used in various techniques. Bioz Stars score: 91/100, based on 43 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/cobas integra 800 analyzer/product/Roche
    Average 91 stars, based on 43 article reviews
    Price from $9.99 to $1999.99
    cobas integra 800 analyzer - by Bioz Stars, 2020-08
    91/100 stars
      Buy from Supplier

    Image Search Results