Review



automated edge-detection algorithm qangio xa 7.3  (Medis)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Medis automated edge-detection algorithm qangio xa 7.3
    Automated Edge Detection Algorithm Qangio Xa 7.3, supplied by Medis, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+algorithm/computer+assisted++automated+edge+detection+algorithm+qangio+xa/pm40503438-67-3-8
    Average 90 stars, based on 1 article reviews
    automated edge-detection algorithm qangio xa 7.3 - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Multivendor Evaluation of Automated MRI Postprocessing of Biventricular Size and Function for Children With and Without Congenital Heart Defects.
    Article Snippet: See the T erm s and C onditions (https://onlinelibrary.w iley.com /term s-and-conditions) on W iley O nline L ibrary for rules of use; O A articles are governed by the applicable C reative C om m ons L icense volumes and lower wall mass and may improve interobserver variability.32,33 To account for these differences, smoothed manual contours were used for all comparisons with the Medis automated segmentation algorithm (both fully automated and adjusted by human input).

    Article Title: Multivendor Evaluation of Automated MRI Postprocessing of Biventricular Size and Function for Children With and Without Congenital Heart Defects.
    Article Snippet: Automated segmentation may be more likely to fail in complicated cases (i.e. smaller children, reduced image quality, more complex cardiac defects).13 The automated segmentation algorithm of Medis provided smoothed contours only and does not provide an option to trace trabeculae of the endocardial border.

    Article Title: Circulating protein biomarkers and their association with vulnerable plaque characteristics - a PROSPECT II substudy.
    Article Snippet: Using an automated edge-detection algorithm (QAngio XA 7.3, Medis Medical Imaging Systems, Leiden, Netherlands), angiographic analyses were performed on all lesions with ≥30 % diameter stenosis in each epicardial vessel and side branches with a diameter ≥1.5 mm.

    Article Title: Optical Coherence Tomography-Guided Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction: Rationale and Design of the ATLAS-OCT Study.
    Article Snippet: 0002-9149/© 2 license (http:// https://doi.org/ Coronary Intervention for ST-Segment Elevation Myocardial Infarction: Rationale and Design of the ATLAS-OCT Study Taishi Yonetsu, MD, PhD, Kohei Wakabayashi, MD, PhD, Takuya Mizukami, MD, PhD, Myong Hwa Yamamoto, MD, PhD, Sakiko Yasuhara, PhD, Seita Kondo, MD, PhD, Yosuke Oishi, MD, PhD, Toshitaka Okabe, MD, PhD, Tomoyo Sugiyama, MD, PhD, Makoto Araki, MD, PhD, Masamichi Takano, MD, PhD, Nobuaki Kobayashi, MD, PhD, Shigeki Kimura, MD, PhD, Yosuke Yamakami, MD, Satoru Suwa, MD, Sunao Nakamura, MD, PhD, Satoru Mitomo, MD, Tsunekazu Kakuta, MD, PhD, Eisuke Usui, MD, PhD, Takumi Higuma, MD, PhD, Junya Ako, MD, PhD, Yoshiyasu Minami, MD, PhD, Masamichi Iwasaki, MD, Junya Shite, MD, PhD, Amane Kozuki, MD, PhD, Shigeru Saito, MD, Koki Shishido, MD, Hiroyuki Okura, MD, PhD, Genki Naruse, MD, PhD, Shiro Uemura, MD, PhD, Teruyoshi Kume, MD, PhD, Mamoru Nanasato, MD, PhD, Tomotaka Dohi, MD, PhD, Takashi Ashikaga, MD, PhD, Hiromasa Otake, MD, PhD, Hiroyoshi Mori, MD, PhD, Teruo Sekimoto, MD, PhD, Yoichiro Sugizaki, MD, PhD, and Toshiro Shinke, MD, PhD*, on Behalf of the ATLAS-OCT Investigators

    Article Title: Mechanism of Stent Failure in Patients with Eruptive Calcified Nodule Treated with Rotational Atherectomy.
    Article Snippet: Shuro Narui, MD, Myong Hwa Yamamoto, MD, PhD, Hiroyoshi Mori, MD, PhD, Kisaki Amemiya, MD, Toshitaka Okabe, MD, PhD, Yui Koyanagi, MD, Yuki Ito, MD, Yuma Gibo, MD, Takeshi Okura, MD, Tatsuki Fujioka, MD, Shigehiro Ishigaki, MD, Soichiro Usumoto, MD, Taro Kimura, MD, Suguru Shimazu, MD, Jumpei Saito, MD, Yuji Oyama, MD, PhD, Wataru Igawa, MD, PhD, Morio Ono, MD, PhD, Naoei Isomura, MD, PhD, Masahiko Ochiai, MD, PhD

    Imaging:

    Article Title: Prospective investigation of calcium score in optical coherence tomography-guided revascularization to identify lesions with low risk for stent under expansion: the CORAL study.
    Article Snippet: The optical coherence tomography (OCT)-based calcium scoring system was developed to guide optimal lesion preparation strategies for percutaneous coronary intervention (PCI) of calcified lesions.. However, the score was derived retrospectively, and a prospective investigation is lacking.. The CORAL (UMIN000053266) study was a single-arm, prospective, multicenter study that included patients with calcified lesions with OCT-calcium score of 1–2 to investigate whether these lesions could be optimally treated with a balloon-only preparation strategy using a non-compliant/scoring/cutting balloon.

    Article Title: Relationships of hsCRP to High-Risk Vulnerable Plaque After NSTEMI: Insights From the PROSPECT II Trial.
    Article Snippet: ISS Fro Fa D Be Co of Sa dio De BACKGROUND Inflammation is a driver of atherosclerosis and susceptibility to cardiovascular events.. OBJECTIVES The authors sought to evaluate whether high-sensitivity C-reactive protein (hsCRP) levels are associated with the prevalence of high-risk coronary plaques in patients with non–ST-segment elevation myocardial infarction (NSTEMI).. METHODS PROSPECT (Providing Regional Observations to Study Predictors of Events in the Coronary Tree) II was a multicenter, prospective study enrolling patients with recent myocardial infarction.



    Similar Products

    99
    Sartorius AG incucyte automated angiogenesis algorithm
    <t>Angiogenesis</t> induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the <t>IncuCyte</t> live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.
    Incucyte Automated Angiogenesis Algorithm, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+algorithm/Live+Cell+Analysis+Instruments/pmc13115070-94-6-13
    Average 99 stars, based on 1 article reviews
    incucyte automated angiogenesis algorithm - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    86
    Persyst Development Corporation neonatal automated seizure detection algorithm
    <t>Angiogenesis</t> induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the <t>IncuCyte</t> live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.
    Neonatal Automated Seizure Detection Algorithm, supplied by Persyst Development Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+algorithm/algorithm+automated+detection+neonatal+seizure/pmc13172172-88-25-24
    Average 86 stars, based on 1 article reviews
    neonatal automated seizure detection algorithm - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Respironics phillips respironics automated activity based sleep algorithm
    <t>Angiogenesis</t> induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the <t>IncuCyte</t> live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.
    Phillips Respironics Automated Activity Based Sleep Algorithm, supplied by Respironics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+algorithm/activity+algorithm+automated+based+phillips+respironics+sleep/med_rxiv__64898__2026__03__05__26347744-36-28-28
    Average 86 stars, based on 1 article reviews
    phillips respironics automated activity based sleep algorithm - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    97
    Bio-Rad algorithms flowlogic
    <t>Angiogenesis</t> induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the <t>IncuCyte</t> live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.
    Algorithms Flowlogic, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+algorithm/TC20+Automated+Cell+Counter/pm40674218-46-127-137
    Average 97 stars, based on 1 article reviews
    algorithms flowlogic - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    90
    Medis automated edge-detection algorithm qangio xa 7.3
    <t>Angiogenesis</t> induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the <t>IncuCyte</t> live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.
    Automated Edge Detection Algorithm Qangio Xa 7.3, supplied by Medis, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+algorithm/computer+assisted++automated+edge+detection+algorithm+qangio+xa/pm40503438-67-3-8
    Average 90 stars, based on 1 article reviews
    automated edge-detection algorithm qangio xa 7.3 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Applied Neuroscience Inc neuroguide's automated artifact rejection algorithm
    <t>Angiogenesis</t> induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the <t>IncuCyte</t> live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.
    Neuroguide's Automated Artifact Rejection Algorithm, supplied by Applied Neuroscience Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+algorithm/neuroguide+s+automated+artifact+rejection+algorithm/pmc12282553-80-8-5
    Average 90 stars, based on 1 article reviews
    neuroguide's automated artifact rejection algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc automated artifact rejection algorithm
    <t>Angiogenesis</t> induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the <t>IncuCyte</t> live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.
    Automated Artifact Rejection Algorithm, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+algorithm/pmc12152602-401-12-17
    Average 90 stars, based on 1 article reviews
    automated artifact rejection algorithm - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    96
    Danaher Inc algorithms imagexpress micro xl ixm automated imaging system molecular devices
    <t>Angiogenesis</t> induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the <t>IncuCyte</t> live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.
    Algorithms Imagexpress Micro Xl Ixm Automated Imaging System Molecular Devices, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+algorithm/ImageXpress+Micro+Confocal+High-Content+Imaging+System/10__1016_slash_j__isci__2025__112501-239-181-188
    Average 96 stars, based on 1 article reviews
    algorithms imagexpress micro xl ixm automated imaging system molecular devices - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    86
    Medis automated edge detection algorithm
    <t>Angiogenesis</t> induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the <t>IncuCyte</t> live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.
    Automated Edge Detection Algorithm, supplied by Medis, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+algorithm/algorithm+automated+detection+edge/pm40436465-47-24-31
    Average 86 stars, based on 1 article reviews
    automated edge detection algorithm - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    90
    Diabetology automated monitoring and thyroid disease diagnosis algorithms
    <t>Angiogenesis</t> induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the <t>IncuCyte</t> live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.
    Automated Monitoring And Thyroid Disease Diagnosis Algorithms, supplied by Diabetology, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/automated+algorithm/thyroid+diseases/pmc12154553-24-15-10
    Average 90 stars, based on 1 article reviews
    automated monitoring and thyroid disease diagnosis algorithms - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Angiogenesis induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the IncuCyte live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.

    Journal: Cells

    Article Title: Extracellular Vesicles Derived from VEGF mRNA-Engineered Mesenchymal Stem Cells Promote Endothelial Cell Survival

    doi: 10.3390/cells15080717

    Figure Lengend Snippet: Angiogenesis induced by VEGF secreted from VEGF-MSCs. Human umbilical vein endothelial cells labelled by CytoLight Green (GFP-HUVECs) were used for the development of angiogenic networks, and the length of networks was determined by the IncuCyte live-cell analysis system. ( A ) VEGF effectively induced the formation of vascular networks, which was able to be inhibited by suramin, a VEGF signaling inhibitor. Data shown as mean (SD) ( n = 6). ( B ) A concentration-dependent effect was shown in the angiogenesis assay using CCM-VEGF with different VEGF concentrations (1, 2, 4, and 8 ng/mL). Blank control, without any VEGF supplement added; suramin group, 4 ng/mL VEGF and 100 µM suramin added. Data shown as mean (SD) ( n = 4); ns, not significant; **** p < 0.05.

    Article Snippet: Image analysis was performed using the IncuCyte automated angiogenesis algorithm (Incucyte software, v2024B, Sartorius).

    Techniques: Cell Analysis, Concentration Assay, Angiogenesis Assay, Control