accela modular hplc system  (Thermo Fisher)


Bioz Verified Symbol Thermo Fisher is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 94

    Structured Review

    Thermo Fisher accela modular hplc system
    Accela Modular Hplc System, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 94/100, based on 2 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/accela modular hplc system/product/Thermo Fisher
    Average 94 stars, based on 2 article reviews
    Price from $9.99 to $1999.99
    accela modular hplc system - by Bioz Stars, 2021-01
    94/100 stars

    Images

    Related Articles

    High Performance Liquid Chromatography:

    Article Title: No Relevant Relationship between Glucose Variability and Oxidative Stress in Well-Regulated Type 2 Diabetes Patients
    Article Snippet: .. Chromatographic separation was achieved on a modular HPLC system (Surveyor® , Thermo Finnigan, San Jose, CA) consisting of a cooled autosampler ( t = 12 °C) and a low-flow quaternary MS pump and analytical HPLC column: Alltima C8, 2.1 × 150 mm, 5 μm (Alltech, Lexington, KY). .. Samples were eluted with a flow rate of 200 μl/min and a programmed linear gradient between A (0.01% HCOOH in H2 O, v/v) and B (CH3 CN): from t = 0 min 45% A, 55% B toward t = 3 min 30% A, 70% B toward t = 3.1 min100% A until t = 6 min. MS/MS analyses were performed on a TSQ Quantum AM (Thermo Finnigan, San Jose, CA) operated in the negative ion electrospray ionization mode.

    Article Title: RodZ and PgsA Play Intertwined Roles in Membrane Homeostasis of Bacillus subtilis and Resistance to Weak Organic Acid Stress
    Article Snippet: .. The liquid-chromatographic separation was achieved on a modular HPLC system (Surveyor; Thermo Finnigan) consisting of a cooled autosampler set at 12°C, a low-flow quaternary MS pump, and an analytical HPLC column: 2.1 × 250 mm silica column, 5 μm particle diameter (Merck). ..

    Article Title: Transcriptional analysis of adipose tissue during development reveals depot-specific responsiveness to maternal dietary supplementation
    Article Snippet: .. A ThermoScientific Accela modular HPLC system (Hemel Hempstead, UK) was used at a flow rate of 0.45 mL/min. .. Ions in the range m/z 100 to 1900 were detected using an Exactive series mass spectrometer (ThermoScientific Hemel Hempstead, UK) in electrospray mode with +/−ve switching at a resolution setting of 25000.

    Clone Assay:

    Article Title: Optimizing the Design of Diatom Biosilica-Targeted Fusion Proteins in Biosensor Construction for Bacillus anthracis Detection
    Article Snippet: .. Further, the Gateway (Invitrogen) modular cloning system leaves substantial scars between units. ..

    Flow Cytometry:

    Article Title: Transcriptional analysis of adipose tissue during development reveals depot-specific responsiveness to maternal dietary supplementation
    Article Snippet: .. A ThermoScientific Accela modular HPLC system (Hemel Hempstead, UK) was used at a flow rate of 0.45 mL/min. .. Ions in the range m/z 100 to 1900 were detected using an Exactive series mass spectrometer (ThermoScientific Hemel Hempstead, UK) in electrospray mode with +/−ve switching at a resolution setting of 25000.

    Cell Counting:

    Article Title: Galectin 3 expression in primary oral squamous cell carcinomas
    Article Snippet: .. Micrographs of the selected areas were imported into the Biomas analysis software (modular systems of applied biology, Erlangen, Germany) for cell counting. .. Two regions of interest were defined in the visual fields using the Biomas software: the epithelial tumor compartment and the stromal compartment.

    Article Title: Macrophage polarisation changes within the time between diagnostic biopsy and tumour resection in oral squamous cell carcinomas—an immunohistochemical study
    Article Snippet: .. The images showing the visual fields were imported into Biomas (modular systems of applied biology, MSAB, Erlangen, Germany) for cell counting. .. Two regions of interest were defined in the visual fields using the Biomas software (Erlangen, Germany): the epithelial tumour fraction and the tumour stroma.

    Mass Spectrometry:

    Article Title: No Relevant Relationship between Glucose Variability and Oxidative Stress in Well-Regulated Type 2 Diabetes Patients
    Article Snippet: .. Chromatographic separation was achieved on a modular HPLC system (Surveyor® , Thermo Finnigan, San Jose, CA) consisting of a cooled autosampler ( t = 12 °C) and a low-flow quaternary MS pump and analytical HPLC column: Alltima C8, 2.1 × 150 mm, 5 μm (Alltech, Lexington, KY). .. Samples were eluted with a flow rate of 200 μl/min and a programmed linear gradient between A (0.01% HCOOH in H2 O, v/v) and B (CH3 CN): from t = 0 min 45% A, 55% B toward t = 3 min 30% A, 70% B toward t = 3.1 min100% A until t = 6 min. MS/MS analyses were performed on a TSQ Quantum AM (Thermo Finnigan, San Jose, CA) operated in the negative ion electrospray ionization mode.

    Article Title: RodZ and PgsA Play Intertwined Roles in Membrane Homeostasis of Bacillus subtilis and Resistance to Weak Organic Acid Stress
    Article Snippet: .. The liquid-chromatographic separation was achieved on a modular HPLC system (Surveyor; Thermo Finnigan) consisting of a cooled autosampler set at 12°C, a low-flow quaternary MS pump, and an analytical HPLC column: 2.1 × 250 mm silica column, 5 μm particle diameter (Merck). ..

    Software:

    Article Title: Galectin 3 expression in primary oral squamous cell carcinomas
    Article Snippet: .. Micrographs of the selected areas were imported into the Biomas analysis software (modular systems of applied biology, Erlangen, Germany) for cell counting. .. Two regions of interest were defined in the visual fields using the Biomas software: the epithelial tumor compartment and the stromal compartment.

    Similar Products

  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 94
    Thermo Fisher accela modular hplc system
    Accela Modular Hplc System, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 94/100, based on 2 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/accela modular hplc system/product/Thermo Fisher
    Average 94 stars, based on 2 article reviews
    Price from $9.99 to $1999.99
    accela modular hplc system - by Bioz Stars, 2021-01
    94/100 stars
      Buy from Supplier

    Image Search Results