patient-based real-time quality control (pbrtqc) (International Federation of Clinical Chemistry and Laboratory Medicine)
Structured Review

Patient Based Real Time Quality Control (Pbrtqc), supplied by International Federation of Clinical Chemistry and Laboratory Medicine, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/time+based+controller/patient+based+real+time+quality+control++pbrtqc+/pmc09459303-68-23-6
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "Assessment of patient based real‐time quality control on comparative assays for common clinical analytes"
Article Title: Assessment of patient based real‐time quality control on comparative assays for common clinical analytes
Journal: Journal of Clinical Laboratory Analysis
doi: 10.1002/jcla.24651
Figure Legend Snippet: Flow chart of (A) PBRTQC procedure and (B) comparative study design. Abbreviation: EWMA, exponentially weighted moving average; LIS, laboratory information system; PBRTQC, patient‐based real‐time quality control
Techniques Used: Control
Figure Legend Snippet: Graphic illustration of the performance of PBRTQC for potassium (K) by introducing positive (regions framed by solid lines) and negative (regions framed by dashed lines) biased data (A‐F) Detected bias data at truncation limits of 3.2–4.9 mmol/L when λ = 0.01 (A) λ = 0.03 (B) and λ = 0.05 (C) and truncation limits of 2.8–6.2 mmol/L when λ = 0.01 (D) λ = 0.03 (E) and λ = 0.05 (F) Regions framed by solid and dashed lines indicate the introduced negative and positive biased data points, respectively. (G and H) Number of test results affected before error detection at truncation limits of 3.2–4.9 mmol/L when λ = 0.03 (G) and λ = 0.05 (H) The black arrows indicate the error introduction data, and red arrows indicate the error detection data. The horizontal black solid line, gray, yellow, and red dashed lines in the graph represent the mean ± 1, 2, and 3 SD of the EWMA results accumulated in the previous 6 months, respectively. The yellow and red curves of the points indicate the alarm and out‐of‐control data points detected, respectively, which are based on the intellectual QC rules in the AI‐MA platform. Abbreviations: EMWA, exponentially weighted moving average; PBRTQC, patient‐based real‐time quality control; QC, quality control; SD, standard deviation
Techniques Used: Control, Standard Deviation
Related Articles
Control:Article Title: Application of Patient‐Based Real‐Time Quality Control Based on Artificial Intelligence Monitoring Platform in Continuously Quality Risk Monitoring of Down Syndrome Serum Screening Article Snippet: In this light, the use of patient samples for the purpose of continuous quality control, also known as patient‐based Article Title: Assessment of patient based real‐time quality control on comparative assays for common clinical analytes Article Snippet: The International Federation of Clinical Chemistry ( Concentration Assay:Article Title: Application of Patient‐Based Real‐Time Quality Control Based on Artificial Intelligence Monitoring Platform in Continuously Quality Risk Monitoring of Down Syndrome Serum Screening Article Snippet: In this light, the use of patient samples for the purpose of continuous quality control, also known as patient‐based Article Title: Assessment of patient based real‐time quality control on comparative assays for common clinical analytes Article Snippet: The International Federation of Clinical Chemistry ( Transformation Assay:Article Title: Application of Patient‐Based Real‐Time Quality Control Based on Artificial Intelligence Monitoring Platform in Continuously Quality Risk Monitoring of Down Syndrome Serum Screening Article Snippet: In this light, the use of patient samples for the purpose of continuous quality control, also known as patient‐based Article Title: Assessment of patient based real‐time quality control on comparative assays for common clinical analytes Article Snippet: The International Federation of Clinical Chemistry ( Standard Deviation:Article Title: Application of Patient‐Based Real‐Time Quality Control Based on Artificial Intelligence Monitoring Platform in Continuously Quality Risk Monitoring of Down Syndrome Serum Screening Article Snippet: In this light, the use of patient samples for the purpose of continuous quality control, also known as patient‐based Article Title: Assessment of patient based real‐time quality control on comparative assays for common clinical analytes Article Snippet: The International Federation of Clinical Chemistry ( |