Review



ml-based ct texture analysis software  (Canon inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Canon inc ml-based ct texture analysis software
    Ml Based Ct Texture Analysis Software, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/texture+analysis+software/ml+based+ct+texture+analysis+software/pm34636644-87-9-51
    Average 90 stars, based on 1 article reviews
    ml-based ct texture analysis software - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    Software:

    Article Title: Machine learning for lung texture analysis on thin-section CT: Capability for assessments of disease severity and therapeutic effect for connective tissue disease patients in comparison with expert panel evaluations.
    Article Snippet: Background: The need for quantitative assessment of interstitial lung involvement on thin-section computed tomography (CT) has arisen in interstitial lung diseases including connective tissue disease (CTD).. Purpose: To evaluate the capability of machine learning (ML)-based CT texture analysis for disease severity and treatment response assessments in comparison with qualitatively assessed thin-section CT for patients with CTD.. Material and Methods: A total of 149 patients with CTD-related ILD (CTD-ILD) underwent initial and follow-up CT scans (total 364 paired serial CTexaminations), pulmonary function tests, and serum KL-6 level tests.



    Similar Products

    90
    MathWorks Inc texture analysis software mtex
    Texture Analysis Software Mtex, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/texture+analysis+software/10__1016_slash_j__jeurceramsoc__2025__117583-103-8-13
    Average 90 stars, based on 1 article reviews
    texture analysis software mtex - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Imbio LLC software for lung texture analysis
    Software For Lung Texture Analysis, supplied by Imbio LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/texture+analysis+software/lung+texture+analysis/pm40197088-58-4-9
    Average 90 stars, based on 1 article reviews
    software for lung texture analysis - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Inserm Transfert texture analysis software lifex version 5.10
    Texture Analysis Software Lifex Version 5.10, supplied by Inserm Transfert, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/texture+analysis+software/texture+analysis+software+lifex+version+5+10/pm40218151-80-19-25
    Average 90 stars, based on 1 article reviews
    texture analysis software lifex version 5.10 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Bruker Corporation diffrac texture analysis software
    Diffrac Texture Analysis Software, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/texture+analysis+software/diffracplus+topas+software/10__1063_slash_5__0243499-81-7-6
    Average 90 stars, based on 1 article reviews
    diffrac texture analysis software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Imbio LLC lung texture analysis software
    Exemplary results of the <t>multi-texture</t> <t>lung</t> <t>analysis</t> tool and the opacity-based lung analysis tool. CT in coronal view of a 62 year old patient with idiopathic pulmonary fibrosis ( A ), analyzed by the opacity-based Pneumonia tool (Siemens Healthineers), the red lines represent the segmented fibrotic areas ( B ) with additional 3D reconstruction ( C ). ( D ) Analysis with the multi-texture lung analysis tool (CALIPER, Biomedical imaging resource laboratory, Mayo Clinic) with the yellow areas representing fibrotic altered tissue.
    Lung Texture Analysis Software, supplied by Imbio LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/texture+analysis+software/lung+texture+analysis/pmc11718064-66-16-20
    Average 90 stars, based on 1 article reviews
    lung texture analysis software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Imbio LLC ai-based quantitative lung texture analysis software
    <t>Lung</t> <t>texture</t> <t>analysis</t> report: The Dicom representative image of each category of pattern. These were chosen based on the predominance of lung parenchymal patterns including hyperlucent, ground glass [GG], reticular, and honeycombing. Imbio LTA provided their regional distribution within three different lung zones [upper, middle, lower] in each lung. The platform provided an image in which each lung pattern was colored differently, allowing the evaluation of disease extent, composition, and location at a glance. Specific images were chosen because of the predominance of one of the patterns in each of them; at the same time, they had other patterns, also showing that all pathologies could coexist in a single case of bronchiectasis, yet have a predominance of a single pattern that may have a bearing on their clinical symptoms.
    Ai Based Quantitative Lung Texture Analysis Software, supplied by Imbio LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/texture+analysis+software/lung+texture+analysis/pmc11675828-87-22-26
    Average 90 stars, based on 1 article reviews
    ai-based quantitative lung texture analysis software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Nexigen GmbH texture analysis software
    <t>Lung</t> <t>texture</t> <t>analysis</t> report: The Dicom representative image of each category of pattern. These were chosen based on the predominance of lung parenchymal patterns including hyperlucent, ground glass [GG], reticular, and honeycombing. Imbio LTA provided their regional distribution within three different lung zones [upper, middle, lower] in each lung. The platform provided an image in which each lung pattern was colored differently, allowing the evaluation of disease extent, composition, and location at a glance. Specific images were chosen because of the predominance of one of the patterns in each of them; at the same time, they had other patterns, also showing that all pathologies could coexist in a single case of bronchiectasis, yet have a predominance of a single pattern that may have a bearing on their clinical symptoms.
    Texture Analysis Software, supplied by Nexigen GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/texture+analysis+software/texture+analysis+software/pmc11667725-103-0-0
    Average 90 stars, based on 1 article reviews
    texture analysis software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Stable Micro Systems Ltd texture analysis software exponent
    <t>Lung</t> <t>texture</t> <t>analysis</t> report: The Dicom representative image of each category of pattern. These were chosen based on the predominance of lung parenchymal patterns including hyperlucent, ground glass [GG], reticular, and honeycombing. Imbio LTA provided their regional distribution within three different lung zones [upper, middle, lower] in each lung. The platform provided an image in which each lung pattern was colored differently, allowing the evaluation of disease extent, composition, and location at a glance. Specific images were chosen because of the predominance of one of the patterns in each of them; at the same time, they had other patterns, also showing that all pathologies could coexist in a single case of bronchiectasis, yet have a predominance of a single pattern that may have a bearing on their clinical symptoms.
    Texture Analysis Software Exponent, supplied by Stable Micro Systems Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/texture+analysis+software/exponent+software/10__1016_slash_j__aquaculture__2024__741163-113-1-6
    Average 90 stars, based on 1 article reviews
    texture analysis software exponent - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Imbio LLC lung texture analysis software imbio version 22.0
    <t>Lung</t> <t>texture</t> <t>analysis</t> report: The Dicom representative image of each category of pattern. These were chosen based on the predominance of lung parenchymal patterns including hyperlucent, ground glass [GG], reticular, and honeycombing. Imbio LTA provided their regional distribution within three different lung zones [upper, middle, lower] in each lung. The platform provided an image in which each lung pattern was colored differently, allowing the evaluation of disease extent, composition, and location at a glance. Specific images were chosen because of the predominance of one of the patterns in each of them; at the same time, they had other patterns, also showing that all pathologies could coexist in a single case of bronchiectasis, yet have a predominance of a single pattern that may have a bearing on their clinical symptoms.
    Lung Texture Analysis Software Imbio Version 22.0, supplied by Imbio LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/texture+analysis+software/lung+texture+analysis/pmc11432915-127-10-10
    Average 90 stars, based on 1 article reviews
    lung texture analysis software imbio version 22.0 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Exemplary results of the multi-texture lung analysis tool and the opacity-based lung analysis tool. CT in coronal view of a 62 year old patient with idiopathic pulmonary fibrosis ( A ), analyzed by the opacity-based Pneumonia tool (Siemens Healthineers), the red lines represent the segmented fibrotic areas ( B ) with additional 3D reconstruction ( C ). ( D ) Analysis with the multi-texture lung analysis tool (CALIPER, Biomedical imaging resource laboratory, Mayo Clinic) with the yellow areas representing fibrotic altered tissue.

    Journal: Scientific Reports

    Article Title: Comparing multi-texture fibrosis analysis versus binary opacity-based abnormality detection for quantitative assessment of idiopathic pulmonary fibrosis

    doi: 10.1038/s41598-025-85135-7

    Figure Lengend Snippet: Exemplary results of the multi-texture lung analysis tool and the opacity-based lung analysis tool. CT in coronal view of a 62 year old patient with idiopathic pulmonary fibrosis ( A ), analyzed by the opacity-based Pneumonia tool (Siemens Healthineers), the red lines represent the segmented fibrotic areas ( B ) with additional 3D reconstruction ( C ). ( D ) Analysis with the multi-texture lung analysis tool (CALIPER, Biomedical imaging resource laboratory, Mayo Clinic) with the yellow areas representing fibrotic altered tissue.

    Article Snippet: The computer-aided lung informatics for pathology evaluation and ratings (CALIPER) tool is part of the Imbio lung texture analysis software (Imbio) and was created by the Biomedical Imaging Resource Laboratory of the Mayo Clinic, Minnesota.

    Techniques: Imaging

    Linear regression analyses. Illustration of regression analysis between the opacity-based fibrotic lung (OFL) and the multi-texture fibrotic lung (MTFL) quantification, as well as regression analysis of OFL and MTFL with spirometry parameters with Pearson correlation coefficient (r) bigger than 0.25. 95% confidence intervals are indicated by light-colored areas. TLC percent predicted total lung capacity, VC percent predicted vital capacity and DL CO diffusing capacity of the lungs for carbon monoxide.

    Journal: Scientific Reports

    Article Title: Comparing multi-texture fibrosis analysis versus binary opacity-based abnormality detection for quantitative assessment of idiopathic pulmonary fibrosis

    doi: 10.1038/s41598-025-85135-7

    Figure Lengend Snippet: Linear regression analyses. Illustration of regression analysis between the opacity-based fibrotic lung (OFL) and the multi-texture fibrotic lung (MTFL) quantification, as well as regression analysis of OFL and MTFL with spirometry parameters with Pearson correlation coefficient (r) bigger than 0.25. 95% confidence intervals are indicated by light-colored areas. TLC percent predicted total lung capacity, VC percent predicted vital capacity and DL CO diffusing capacity of the lungs for carbon monoxide.

    Article Snippet: The computer-aided lung informatics for pathology evaluation and ratings (CALIPER) tool is part of the Imbio lung texture analysis software (Imbio) and was created by the Biomedical Imaging Resource Laboratory of the Mayo Clinic, Minnesota.

    Techniques:

    Bland-Altman analysis. The opacity-based fibrotic lung (OFL) quantifications was compared to the multi-texture fibrotic lung (MTFL) measurements.

    Journal: Scientific Reports

    Article Title: Comparing multi-texture fibrosis analysis versus binary opacity-based abnormality detection for quantitative assessment of idiopathic pulmonary fibrosis

    doi: 10.1038/s41598-025-85135-7

    Figure Lengend Snippet: Bland-Altman analysis. The opacity-based fibrotic lung (OFL) quantifications was compared to the multi-texture fibrotic lung (MTFL) measurements.

    Article Snippet: The computer-aided lung informatics for pathology evaluation and ratings (CALIPER) tool is part of the Imbio lung texture analysis software (Imbio) and was created by the Biomedical Imaging Resource Laboratory of the Mayo Clinic, Minnesota.

    Techniques:

    Lung texture analysis report: The Dicom representative image of each category of pattern. These were chosen based on the predominance of lung parenchymal patterns including hyperlucent, ground glass [GG], reticular, and honeycombing. Imbio LTA provided their regional distribution within three different lung zones [upper, middle, lower] in each lung. The platform provided an image in which each lung pattern was colored differently, allowing the evaluation of disease extent, composition, and location at a glance. Specific images were chosen because of the predominance of one of the patterns in each of them; at the same time, they had other patterns, also showing that all pathologies could coexist in a single case of bronchiectasis, yet have a predominance of a single pattern that may have a bearing on their clinical symptoms.

    Journal: Diagnostics

    Article Title: Artificial Intelligence Unveils the Unseen: Mapping Novel Lung Patterns in Bronchiectasis via Texture Analysis

    doi: 10.3390/diagnostics14242883

    Figure Lengend Snippet: Lung texture analysis report: The Dicom representative image of each category of pattern. These were chosen based on the predominance of lung parenchymal patterns including hyperlucent, ground glass [GG], reticular, and honeycombing. Imbio LTA provided their regional distribution within three different lung zones [upper, middle, lower] in each lung. The platform provided an image in which each lung pattern was colored differently, allowing the evaluation of disease extent, composition, and location at a glance. Specific images were chosen because of the predominance of one of the patterns in each of them; at the same time, they had other patterns, also showing that all pathologies could coexist in a single case of bronchiectasis, yet have a predominance of a single pattern that may have a bearing on their clinical symptoms.

    Article Snippet: This study aimed to assess lung involvement in patients with bronchiectasis using the Bronchiectasis Radiologically Indexed CT Score (BRICS) and AI-based quantitative lung texture analysis software (IMBIO, Version 2.2.0).

    Techniques: